Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 153 PKT 21 SECTOR 24 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 2 | Admitted-Finance RZ 104A GROUND FLOOR VISHWAS PARK UTTAM NAGAR WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹18,800
Closing Date
21 Dec 2021, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEEANDMWSCN/M-5
EEEANDMWSCN/M-5 NEAR KANHIYA NAGAR METRO STATION DELHI -35
Improvement of submersibleS sub panel installed at Pahadi Dheeraj Old Pumphouse
2021_DJB_212756_9
NIT NO. 13 (2021-2022)
Open Tender
Miscellaneous Services
Item Rate
30 days
EEEANDMWSCN/M-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹18,800
Yes
29 Dec 2021
15 Dec 2021
21 Dec 2021
15 Dec 2021
21 Dec 2021
15 Dec 2021
120 days
Dismantling of old sub panel including removing of all electric connections while taking all safety precautions and cutting of old rusted nuts and MS bar with help of electric cutter/ manual labour including making the surface even with minor civil work for laying foundation for new panel as per site requirement.
For submersible sub panel. Supply / Fabrication of LT Panel Board cubical type, floor mounting, dust & vermin proof construction, of the minimum size 1000 mm X 1000 mm X 375 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), having chambers suitable to switch gears to be fitted as below with provisions for cable entry from bottom. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 250 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and all the switchgears as below (S. No 27 to 41)duly fitted / installed properly as per requirement.
S/o Moulded Case Circuit Breaker (MCCB) of rating 125 Amp, Four Pole, 415 V, AC of breaking capacity of 36 kA or more with Spreader Link. Make: Havells/Selec/ L&T/ Schneider/ DJB approved make
S/o Moulded Case Circuit Breaker (MCCB) of rating 100 Amp, Triple Pole, 415 V, AC of breaking capacity of 36 kA or more with Spreader Link. Make: Havells/Selec/ L&T/ Schneider/ DJB approved make
TP Air Break Contactor 70 Amps Coil Voltage 240 Make Make: - Havells/Selec/ L&T/ Schneider/ DJB approved make
TP Air Break Contactor 60 Amps Coil Voltage 240 Make Make: - Havells/Selec/ L&T/ Schneider/ DJB approved make
Star Delta Timer 0-20 Sec,240 Voltage Make: - Selec/ L&T/ Schneider/ DJB approved make
Microprocessor based Motor Protection Device having following protection Over Voltage/Under voltage/Single phase /Phase reversal/over current/under current Protection. Make:-L&T/ Schneider/ DJB approved make
TP thermal overload Relay Range 3- Make: - L&T/ Schneider/ DJB approved make
S/o PVC insulated copper flexible cable single core 16 sqmm. Make: Havells / Fort Gloster / ICC /DJB approved make
S/o Ampere Meter 100/5 Amp. Digital type. Make: -AE/ L&T/ DJB approved make
S/o Voltmeter Digital type Make: - AE/ L&T/ DJB approved make
S/o Current Transformer 100/5 Amp. Digital type. .Make: - AE/ L&T/ DJB approved make
SP MCB. 6A. Make L&T/ Schneider/ DJB approved make.
On/Off Push Button 22.5 Make: - Warner/ Selec/ DJB approved make
S/o Indicating Lamp, Led type Make: - IEC/ L&T/ DJB approved make
Packing and transportation charges of the main incomer distribution panel of dimensions 3000 X 2000 X 375 mm and submersible sub panel of dimension 1000X1000X375 mm. This includes shifting of the complete big panels from workshop to site and transportation and loading unloading cost done with the help of crane and manual labour.
Supply of PVC 3.5 core, 50 sq. mm copper cable round and sheathed. Make: Fort Gloster, ICC, Grandlay, DJB approved make.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness. E&M DSR (2018).4.1.8
Laying and fixing of above 50 sq. Mm 3.5 core copper cable between the two panel along the laid cable tray between the two panels
S/o of 70 sq. Mm copper single core flexible PVC cable. Make: Fort Gloster, ICC, Grandlay, DJB approved make
Installation of the new L.T. Panel at site including providing of the all material required for fixing the panel in the newly laid foundation including grouting and minor civil work as per satisfaction of engineer in charge.
Making the Required incoming power supply connections between main supply and new incomer panel by connecting the cable after relaying of cable and re thimbling of cable ends as per requirement.
Testing & commissioning of the new starter panels including testing for their manual/ automatic operations for the pumps as after making required configurations for the automatic operations in the starters. Testing of Starters at No Load and then at on Load. Testing of tripping system of starters as per requirement
BHANU AND CO
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .