Loading…
Loading…
Tender ID
Tender Value
₹10.4 Cr
EMD Value
₹10.4 L
Closing Date
28 Apr 2026, 6:00 pmClosed
executive Engineer,GSPHCL,Ahmedabad
CONSTRUCTION OF MADHUPURA URBAN and L TRAFFIC POLICE STATION (B+G+4) AT MADHUPURA, Dist.- AHMEDABAD(INCLUDING ELECTRIFICATION WORK) (First attempt) (SBD)
295448
15 (2025-2026)
Open
Civil - All
Works
Ahmedabad
18 documents required · 16 mandatory · 2 optional
₹18,000
GUJARAT STATE POLICE HOU.CORPORATION LTD.Ahmedabad
₹10.4 L
8 Apr 2026
8 Apr 2026
8 Apr 2026
28 Apr 2026
8 Apr 2026
SCHEDULE -B WITH RATE
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Excavation for foundation in loose or soft soil upto 1.5 m. depth including sorting out and stacking of useful materials and disposing of the excavated stuff upto any Lead RS: One Hundred Fifteen and Paise Ninty
and lift. Two only
Excavation for foundation indense or hard soil 1.5 m. to 3.0 m depth including sorting out and stacking of useful materials and disposing of the excavated stuff upto any RS: One Hundred Sixty and Paise Seventy
Lead and lift. Seven only
Excavation for foundation in dense or hard soil 3.0 m. to 5.0 m depth including sorting out and stacking of useful materials and disposing of the excavated stuff upto any RS: One Hundred Seventy Two and Paise Fifty
Lead and lift. only
Excavation for foundation indense or hard soil MORE THAN 5.0 m depth including sorting out and stacking of useful materials and disposing of the excavated stuff upto RS: One Hundred Ninty Three and Paise Forty
any Lead and lift. One only
Providing and laying cement concrete 1:3:6(1- cement : 3- coarse sand : 6- hand broken stone aggregates 20 mm. nominal size) and curing complete excluding cost of RS: Two Thousand Nine Hundred Seventy Six
from work in : (a) Foundation and plinth. only
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of RS: Two Thousand Six Hundred Fifty Three and
formwork in (A) Foundation and Plinth Paise Sixty Seven only
Provinding and Laying controlled cement concrete M-300 including finising smooth with curing complete including the cost of form work of plywood only with fairfinish and
RS: Four Thousand Seven Hundred Fifty Seven
7 proping must be of steel only to as to give fair finish but excluding the cost of reinforced concrete work in foundation FOOTING and Mass Concrete.rates are inclusive of 1146.00 CMT 4757.89
and Paise Eighty Nine only
providing and mixing plasticizer of approved make in proportion as per mix design.
Providing and laying Controlled Cement Concrete M-300 and finishing smooth with curing etc. complete including cost of formwork of plywood only with fairfinish and
RS: Nine Thousand One Hundred Seventy Six
8 proping must be of steel only to as to give fair finish but excluding the cost of reinforcement for R.C.C.work in Column upto Plinth for any cross sectional area of column. 102.00 CMT 9176.50
and Paise Fifty only
rates are inclusive of providing and mixing plasticizer of approved make in proportion as per mix design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing complete including cost of formwork of plywood only with fairfinish and
RS: Nine Thousand Seven Hundred Seventeen
9 proping must be of steel only to as to give fair finish but excluding the cost of reinforcement in RETAINING WALL.For any cross sectional area of WALL .Rates Are 94.00 CMT 9717.79
and Paise Seventy Nine only
Inclusive Of Providing & Mixing Plastisizer Of Approved Make & In Proportion As Per Mix Design
Filling avaliable excavate earth ( excluding rock). In trenches, plinth sides of foundations etc. in layers NOt exceeding 20 cms. In depth consolidation each deposited layer RS: One Hundred Twenty Nine and Paise Ten
by ramming and watering. only
Applying general insecticide pest control treatment to floors, cupboards etc including labour material etc. complete. Using Imidacloprid 30.5 SCas as Per 6313part -II
11 796.00 SMT 88.40 RS: Eighty Eight and Paise Forty only
(0.075 % concentration by mass) is recommended 10.5 ml chemical diluted with 5 litres of water application 0.5 litre chemical/Sqm if surface is recommended as per I.S.
RS: Four Hundred Fifty Five and Paise Sixty
12 FILLING in plinth with SAND under floors including watering, raming consolidating and dressing etc. complete. 80.00 CMT 455.63
Providing and laying Controlled cement concrete M-300 and finishing smooth with curing etc.. complete Including the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Two Hundred Fifteen and
13 Proping must be of steel only so as to give a fair finish. but exculding the cost of reinforcement for PLINTH BEAMS/TIE BEAM . Rates are Inclusive of Providing and 36.00 CMT 7215.32
Paise Thirty Two only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Provinding and Laying controlled cement concrete M-250 including finising smooth of plywood only with fairfinish and proping must be of steel only to as to give fair finish
RS: Four Thousand Two Hundred Thirty Eight
14 with curing complete including the cost of form workbut excluding the cost of reinforced concrete work in foundation FOOTING and Mass Concrete...(GRID SLAB @ 120.00 CMT 4238.04
and Paise Four only
Brick work using common burnt clay building bricks having crushing strength Nost less than 35 Kg/Sq.cm.below plinth level conventional bricksin cement mortar 1:6(1- RS: Three Thousand Nine Hundred Eighty One
cement;6-fine sand) in foundation and plinth. and Paise Twenty One only
Provinding 10 mm thick cement PLASTER in single coat of interior plastering and finished even and smooth in cement mortar 1:3 ( 1 cement : 3 sand ) and finishing with
RS: One Hundred Eighty Three and Paise
16 floating coat of neat cement slurry including providing and mixing WATER PROFFING material in C.M in proportion recomended by the manufacturer including finishing 1123.00 SMT 183.13
with a floatingcoat of neat cement slurry AT BASEMENT FLOOR LEVEL (UPTO PLINTH)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Integral Crystalline Waterproofing admixture cementitious dry powder consisting of hydrophilic chemicals, when added directly to the plastic mix will permanently create
impermeable hardened concrete by developing insoluble hydration needle like crystals when comes in contact with unhydrated cement and moisture to seal the pores,
intercises, micro cracks in the concrete by reacting with the un-hydrated cement particles . It will self-seal the cracks upto 0.5 – 0.6mm .Chloride content shall be within the
permissible limit as stated in IS 9103/ IS 6925-73 (Guideline). It shall confirm to ASTM C 494-Type D standards and certified by the International Code Council Evaluation
Service (ICC-ES). It shall be compatible to any other concrete admixture confirming to ASTM C 494 and IS 9103. The material shall be ISI Marked. The crystalline treated
concrete will with stand high hydrostatic pressure.When tested Krystol Internal Membrane (KIM) treated concrete passed the Permeability test as per US Army Corps of
Engineers CRD C-48-92 (For 140 M water head) and DIN 1048-Part 5 (For 163.19 M water head).It does not contain oils, stearates, sodium, any silicates or talc and should
not be hydrophobic. It should be able to grow crystals year after year to bridge micro cracks (not live/moving cracks) that may occur from time to time. In order to produce
crystals to fill up the pores the crystalline product will not be dependent on the presence of free lime in hardened concrete. It will minimize shrinkage cracks and help in
internal curing.It will be ne nontoxic and confirming to NSF (USA) certification for use of structure holding potable water, based on testing in accordance with NSF 61 & US
RS: Nine Hundred Forty and Paise Seventy
17 Environmental Protection Agency. Dosage will be recommended by the manufacturer and shoul be in between 0.8 % by weight of cement. Considering cement content as 1262.00 CMT 940.74
410 Kg per Cum of concret for M30 grade concrete.
Providing and laying Thermo mechanically treated (TMT -500D) steel einforcement of approved brand only for R.C.C. work including cutting, bending binding and placing
18 392326.00 KG. 76.72 RS: Seventy Six and Paise Seventy Two only
in position etc. complete for all floors.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Five Hundred Sixty Six and
19 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for GROUND FLOOR. Rates are Inclusive of Providing and 44.00 CMT 10566.60
Paise Sixty only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Six Hundred Six and Paise
20 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for FIRST FLOOR. Rates are Inclusive of Providing and Mixing 44.00 CMT 10606.45
Forty Five only
Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Six Hundred Forty Six and
21 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for SECOND FLOOR. Rates are Inclusive of Providing and 44.00 CMT 10646.30
Paise Thirty only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Six Hundred Eighty Six and
22 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for THIRD FLOOR. Rates are Inclusive of Providing and 44.00 CMT 10686.15
Paise Fifteen only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Seven Hundred Twenty Six
23 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for FOUR FLOOR. Rates are Inclusive of Providing and Mixing 44.00 CMT 10726.00
Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Seven Hundred Sixty Five
24 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for FIFTH FLOOR. Rates are Inclusive of Providing and Mixing 5.00 CMT 10765.85
and Paise Eighty Five only
Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Ten Thousand Eight Hundred Five and
25 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in COLUMN for SIX FLOOR. Rates are Inclusive of Providing and Mixing 4.00 CMT 10805.70
Paise Seventy only
Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand One Hundred Ninty Four
26 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for GROUND FLOOR. Rates are Inclusive of Providing 65.00 CMT 8194.90
and Paise Ninty only
and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Two Hundred Thirty Four
27 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for FIRST FLOOR. Rates are Inclusive of Providing and 24.00 CMT 8234.75
and Paise Seventy Five only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Two Hundred Seventy Four
28 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for SECOND FLOOR. Rates are Inclusive of Providing 24.00 CMT 8274.60
and Paise Sixty only
and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Three Hundred Fourteen
29 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for THIRD FLOOR. Rates are Inclusive of Providing and 24.00 CMT 8314.45
and Paise Forty Five only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Three Hundred Fifty Four
30 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for FOUR FLOOR. Rates are Inclusive of Providing and 24.00 CMT 8354.30
and Paise Thirty only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Three Hundred Ninty Four
31 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for FIFTH FLOOR. Rates are Inclusive of Providing and 9.00 CMT 8394.15
and Paise Fifteen only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Four Hundred Thirty Four
32 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SHEAR WALL for SIX FLOOR. Rates are Inclusive of Providing and 7.00 CMT 8434.00
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Nine Hundred Twenty One
33 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 89.00 CMT 8921.69
and Paise Sixty Nine only
Approved Make & In Proportion As Per Mix Design.FOR GROUND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Nine Hundred Sixty One
34 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 42.00 CMT 8961.54
and Paise Fifty Four only
Approved Make & In Proportion As Per Mix Design.FOR 1ST FLOOR
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Nine Thousand One and Paise Thirty
35 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 42.00 CMT 9001.39
Approved Make & In Proportion As Per Mix Design.FOR 2ND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Nine Thousand Forty One and Paise
36 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 44.00 CMT 9041.24
Twenty Four only
Approved Make & In Proportion As Per Mix Design.FOR 3RD FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Nine Thousand Eighty One and Paise
37 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 44.00 CMT 9081.09
Approved Make & In Proportion As Per Mix Design.FOR 4TH FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Nine Thousand One Hundred Twenty and
38 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 9120.94
Paise Ninty Four only
Approved Make & In Proportion As Per Mix Design.FOR 5TH FLOOR
Providing & laying controlled cement concrete M -250 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Nine Thousand One Hundred Sixty and
39 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in BEAM . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 9160.79
Paise Seventy Nine only
Approved Make & In Proportion As Per Mix Design.FOR 6TH FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Two Hundred Eighty Eight
40 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 61.00 CMT 8288.89
and Paise Eighty Nine only
Approved Make & In Proportion As Per Mix Design 10cm upto 13cm. FOR GROUND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Eight Hundred Sixty Four
41 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 70.00 CMT 7864.99
and Paise Ninty Nine only
Approved Make & In Proportion As Per Mix Design .FOYER SLAB 13 to 15 cm thick GROUND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Six Hundred Forty Five
42 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 6.00 CMT 7645.80
and Paise Eighty only
Approved Make & In Proportion As Per Mix Design.LANDING SLAB 23 to 25 cm thick GROUND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Three Hundred Twenty
43 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 61.00 CMT 8328.74
Eight and Paise Seventy Four only
Approved Make & In Proportion As Per Mix Design 10cm upto 13cm. FOR FIRST FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Nine Hundred Four and
44 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 7904.84
Paise Eighty Four only
Approved Make & In Proportion As Per Mix Design. FOYER SLAB 13 to 15 cm thick FIRST FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Six Hundred Eighty Five
45 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 3.00 CMT 7685.65
and Paise Sixty Five only
Approved Make & In Proportion As Per Mix Design.LANDING SLAB 23 to 25 cm thick FIRST FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Three Hundred Sixty Eight
46 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 61.00 CMT 8368.59
and Paise Fifty Nine only
Approved Make & In Proportion As Per Mix Design 10cm upto 13cm. FOR SECOND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Nine Hundred Forty Four
47 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 7944.69
and Paise Sixty Nine only
Approved Make & In Proportion As Per Mix Design.FOYER SLAB 13 to 15 cm thick SECOND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Seven Hundred Twenty
48 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 3.00 CMT 7725.50
Five and Paise Fifty only
Approved Make & In Proportion As Per Mix Design.LANDING SLAB 23 to 25 cm thick SECOND FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Four Hundred Eight and
49 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 61.00 CMT 8408.44
Paise Forty Four only
Approved Make & In Proportion As Per Mix Design 10cm upto 13cm. FOR THIRD FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Nine Hundred Eighty Four
50 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 7984.54
and Paise Fifty Four only
Approved Make & In Proportion As Per Mix Design.FOYER SLAB 13 to 15 cm thick THIRD FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Seven Hundred Sixty Five
51 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 3.00 CMT 7765.35
and Paise Thirty Five only
Approved Make & In Proportion As Per Mix Design. LANDING SLAB 23 to 25 cm thick THIRD FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Four Hundred Forty Eight
52 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 61.00 CMT 8448.29
and Paise Twenty Nine only
Approved Make & In Proportion As Per Mix Design 10cm upto 13cm.FOR FOURTH FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Twenty Four and Paise
53 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 8024.39
Thirty Nine only
Approved Make & In Proportion As Per Mix Design .FOYER SLAB 13 to 15 cm thick FOURTH FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Seven Thousand Eight Hundred Five and
54 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 3.00 CMT 7805.20
Paise Twenty only
Approved Make & In Proportion As Per Mix Design.LANDING SLAB 23 to 25 cm thick FOURTH FLOOR.
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand Sixty Four and Paise
55 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 8064.24
Twenty Four only
Approved Make & In Proportion As Per Mix Design .FOYER SLAB 13 to 15 cm thick FOR FIFTH FLOOR.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing & laying controlled cement concrete M-300 including finishing smooth with curing completeIncluding the cost of form work of Plywood only with fair finish &
RS: Eight Thousand One Hundred Four and
56 Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement in SLAB . Rates are Inclusive of Providing and Mixing Plasticiser of 4.00 CMT 8104.09
Paise Nine only
Approved Make & In Proportion As Per Mix Design.FOYER SLAB 13 to 15 cm thick SIXTH FLOOR.
Providing and laying controlled cement concrete M-300 for reinforcement concrete Chajjas.NOt exceeding 10cm thickness upto floor two level including finishing the
RS: Nine Thousand Six Hundred Seventy Eight
57 expased surface with cement mortar 1:3 ( 1 cement : 3 fine sand) to give a smooth surface. including formwork & curing etc. complete excluding cost of reinforcement.Rate 17.00 CMT 9678.18
and Paise Eighteen only
are also inclusive of providing and mixing Plasticizer of approved make in proportion as Per Mix Design. FOR ALL FLOOR.
Providing and laying controlled cement concrete M-300 including finishing smooth with curing complete including cost of formwork but excluding cost of reinforcement in RS: Eight Thousand Three Hundred Sixty Five
stair case for all floor.RRate are also inclusive of providing and mixing Plasticizer of approved make in proportion as Per Mix Design.in STAIRCASE FOR All Floors. and Paise Eleven only
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Including the cost of form work of Plywood only with
RS: Eight Thousand Six Hundred Eleven and
59 fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for GROUND FLOOR. Rates are Inclusive of Providing and 3.00 CMT 8611.26
Paise Twenty Six only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete Including the cost of form work of Plywood
RS: Eight Thousand Six Hundred Fifty One and
60 only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for FIRST FLOOR. Rates are Inclusive of Providing 8.00 CMT 8651.11
Paise Eleven only
and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete iIncluding the cost of form work of
RS: Eight Thousand Six Hundred Ninty and
61 Plywood only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for SECOND FLOOR Rates are Inclusive of 7.00 CMT 8690.96
Paise Ninty Six only
Providing and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete Including the cost of form work of Plywood
RS: Eight Thousand Seven Hundred Thirty and
62 only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for THIRD FLOOR. Rates are Inclusive of Providing 8.00 CMT 8730.81
Paise Eighty One only
and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete iIncluding the cost of form work of
RS: Eight Thousand Seven Hundred Seventy
63 Plywood only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for FOURTH FLOOR Rates are Inclusive of 8.00 CMT 8770.66
and Paise Sixty Six only
Providing and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete Including the cost of form work of Plywood
RS: Eight Thousand Eight Hundred Ten and
64 only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for FIFTH FLOOR. Rates are Inclusive of Providing 1.00 CMT 8810.51
Paise Fifty One only
and Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying Controlled cement concrete M-300 for R.C.C. LINTEL including finishing smooth with curing etc. Complete Including the cost of form work of Plywood
RS: Eight Thousand Eight Hundred Fifty and
65 only with fair finish & Proping must be of steel only so as to give a fair finish. but excluding the cost of reinforcement for SIX FLOOR. Rates are Inclusive of Providing and 1.00 CMT 8850.36
Paise Thirty Six only
Mixing Plasticiser of Approved Make & In Proportion As Per Mix Design.
Providing and laying controlled cement concrete M-300 including finishing smooth with curing complete including cost of formwork but excluding cost of reinforcement in
RS: Fourteen Thousand Six Hundred Fifty One
66 vertical & horizontal fins for all floor.Rate are also inclusive of providing and mixing Plasticizer of approved make in proportion as Per Mix Design. VERTICAL AND 32.00 CMT 14651.72
and Paise Seventy Two only
HORIZONTAL FINS / PADADI FOR ALL FLOORS.
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Two Hundred Fifty Three
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for GROUND FLOOR. and Paise Forty Six only
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Two Hundred Ninty Three
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for FIRST FLOOR. and Paise Twenty Five only
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Three Hundred Thirty Three
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for SECOND FLOOR. and Paise Four only
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Three Hundred Seventy
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for THIRD FLOOR. Two and Paise Eighty Three only
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Four Hundred Twelve and
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for FOURTH FLOOR. Paise Sixty Two only
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Four Hundred Fifty Two and
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for FIFTH FLOOR Paise Forty One only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
BRICK WORK using common burnt clay building bricks having crushing strength not less than 35 Kgs. / Sq. cm. In Super structure above plinth level upto floor two level. RS: Four Thousand Four Hundred Ninty Two
Conventional bricks in Cement Mortar (1:6) (1 Cement : 6 coarse sand) for SIXTH FLOOR and Paise Twenty only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Forty Six and Paise Seventy
(conventional bricks for GROUND FLOOR) only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Fifty Two and Paise Sixty
(conventional bricks for 1ST FLOOR) Four only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Fifty Eight and Paise Fifty
(conventional bricks for 2 ND FLOOR) Eight only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Sixty Four and Paise Fifty
(conventional bricks for 3RD FLOOR) Two only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Seventy and Paise Forty Six
(conventional bricks for 4TH FLOOR) only
HALF BRICK masonary in common brunt clay building bricks having crusing strength NOt less than 35 kg./sq.cm.in cement mortar 1:4 (1 cement : 4 coarse sand ) RS: Six Hundred Seventy Six and Paise Forty
(conventional bricks for 5TH FLOOR) only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: One Hundred Ninty Nine and Paise Eighty
finishing with floating coat of neat cement at Ground Floor. Eight only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: Two Hundred Twenty Five and Paise Sixty
finishing with floating coat of neat cement at FIRST Floor. Nine only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 coarse sand ) RS: Two Hundred Fifty One and Paise Fifty
including finishing with floating coat of neat cement at SECOND Floor. only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: Two Hundred Seventy Seven and Paise
finishing with floating coat of neat cement at THIRD Floor. Thirty One only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: Three Hundred Three and Paise Twelve
finishing with floating coat of neat cement at FORTH Floor. only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: Three Hundred Twenty Eight and Paise
finishing with floating coat of neat cement at FIFTH Floor. Ninty Three only
Provinding 10 mm thick cement PLASTER in single coat on CEILING for interior plastering and finished even and smooth in C.M. 1:3 ( 1 cement : 3 sand ) including RS: Three Hundred Fifty Four and Paise
finishing with floating coat of neat cement at SIXTH Floor. Seventy Four only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Two Hundred Three and Paise Thirty
sand ) including finishing with floating coat of neat cement slurry at GROUND FLOOR. Four only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Two Hundred Thirty One and Paise
sand ) including finishing with floating coat of neat cement slurry at FIRST FLOOR. Twenty only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Two Hundred Fifty Nine and Paise Six
coarse sand ) including finishing with floating coat of neat cement slurry at SECOND FLOOR. only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Two Hundred Eighty Six and Paise Ninty
coarse sand ) including finishing with floating coat of neat cement slurry at THIRD FLOOR . Two only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Three Hundred Fourteen and Paise
sand ) including finishing with floating coat of neat cement slurry at FORTH FLOOR. Seventy Eight only
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Three Hundred Forty Two and Paise Sixty
sand ) including finishing with floating coat of neat cement slurry at FIFTH FLOOR. Four only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Provinding 15 mm thick cement PLASTER in single coat on BRICK or CONCRETE wall for interior plastering and finished even and smooth in C.M. 1:4 ( 1 cement : 4 RS: Three Hundred Seventy and Paise Fifty
coarse sand ) including finishing with floating coat of neat cement slurry at SIXTH FLOOR. only
Synthetic Texture Plaster with Double Coat Smooth plaster : Providing 20mm thick cement plaster in single coat plastering upto for Outside and finished even and smooth
in (i) Cement mortar 1:3 (1-cement : 3-sand) as Base Coat and providing 2-3 mm thick synthetic texture plaster of approved texture including cost of all rate are materials, RS: Five Hundred Nine and Paise Fifty Eight
labour, conveyance, loading and unloading, taxes, royalties, scaffolding, watering etc.complete for any Height as per Drawing and instructions of Engineer -in - only
Charge.(Material Shall be Used as Approved By GSPHCL Only )
Provinding 10 mm thick cement PLASTER in single coat of interior plastering and finished even and smooth in cement mortar 1:3 ( 1 cement : 3 sand ) and finishing with
RS: Two Hundred Thirty Eight and Paise
95 floating coat of neat cement slurry including providing and mixing WATER PROFFING material in C.M in proportion recomended by the manufacturer including finishing 207.00 SMT 238.85
Eighty Five only
with a floatingcoat of neat cement slurry. FOR ALL FLOOR
Providing & laying acrylic based modified cementitious composite coating system in two coats.1st coat shall be acrylic polymer & cement & second coat shall be of acrylic RS: One Hundred Ten and Paise Seventy
polymer ,cement & silica sand.The application of both the coats shall be as per manufacturer's manual. only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
RS: Seven Hundred Ninty One and Paise Sixty
97 Providing and filling light weight filling material (CINDER) an approved in sunk slabs or as may be directed at all floors including watering, consolidation etc.. Complete. 42.00 CMT 791.68
Providing, Supplying and Fixing of 32mm (Total) Thick Double Flush Door Shutter with 1mm Thick Laminates on Both Side of Shutter. Making / Construction of Flush Door
is with Pine or southern Yellow Pine Filler and 2.5mm core veneer Both Side and 0.4mm Face Veneer on Both Side with Lock rail on Center. Flush Door Provide with Teak
wood beading patti (32mm X 12mm) on Peripheries of Flush Door with Door Frame of Non Teak Solid Wood of size 150mm x 70mm with Chemically Treated and
RS: Twelve Thousand Eight Hundred Seventy
98 Seasoned Including Paint Matching with Laminates. Frame & Flush door shutter having 5 year warranty against attack of biological agent like termite, borers, decay, fungi 29.00 SMT 12870.01
and Paise One only
and harmful insects also warranty against seasoning related issues like crack, bending, twisting, warping. Laminates on shutter shall be press by cold press method. Shutter
shall be brought to site in packed PVC bags & pvc coating shall be removed on completion of work in such a way that shutter & Frame is free from nail mark & any
Rates are also Inclusive of all Labors & Proviging 15cm. Long 8 No of Hold Fast (25mm X 5mm) & 8 No of 6 Inch S.S. but Hinges, 100mm x 75 mm x 3mm thick, required
Screw & Nails per Frame and Fixing 6mm thick Glass on Top of Door Frame with Battens Patti, following S.S. Fixtures And Fastening.
(1) Aldrops 2 No, 250mm x 16mm, (2) Door Stopper 2 No, 100mm Long, (3) Double Leg Heavy Push Door Stopper 2 No & (4) Handle 4 No, 150mm Long X 10mm thick.
Door with Glass are Fixing as per Details Drawing & Instruction of Engineer in charge. All Materials Used Shall be as Per approved Material Make List of G.S.P.H.C. The
Required Frame is to be Obtained from Vanil Udhyog Maked Only.
Providing, Supplying and Fixing of 32mm (Total) Thick Single Flush Door Shutter with 1mm Thick Laminates on Both Side of Shutter. Making / Construction of Flush Door
is with Pine or southern Yellow Pine Filler and 2.5mm core veneer Both Side and 0.4mm Face Veneer on Both Side with Lock rail on Center. Flush Door Provide with Teak
wood beading patti (32mm X 12mm) on Peripheries of Flush Door with Door Frame of Non Teak Solid Wood of size 100mm x 60mm with Chemically Treated and
RS: Eight Thousand Three Hundred Ninty Nine
99 Seasoned Including Paint Matching with Laminates. Frame & Flush door shutter having 5 year warranty against attack of biological agent like termite, borers, decay, fungi 123.00 SMT 8399.74
and Paise Seventy Four only
and harmful insects also warranty against seasoning related issues like crack, bending, twisting, warping. Laminates on shutter shall be press by cold press method. Shutter
shall be brought to site in packed PVC bags & pvc coating shall be removed on completion of work in such a way that shutter & Frame is free from nail mark & any
Rates are also Inclusive of all Labors & Proviging 15cm. Long 8 No of Hold Fast (25mm X 5mm) & 4 No of 6 Inch S.S. but Hinges, 100mm x 75 mm x 3mm thick, required
Screw & Nails per Frame and Fixing following S.S. Fixtures And Fastening. (1) Aldrops 1 No, 250mm x 16mm & Tadi 1 No, (2) Door Stopper 1 No, 100mm Long, (3)
Double Leg Heavy Push Door Stopper 1 No & (4) Handle 2 No, 150mm Long X 10mm thick. Door are Fixing as per Details Drawing & Instruction of Engineer in charge. All
Materials Used Shall be as Per approved Material Make List of G.S.P.H.C. The Required Frame is to be Obtained from Vanil Udhyog Maked Only.
Providing and fixing solid PVC Flush Door shutter 24mm thick,made from Co-extruded three layer rigid PVC foam sheet(single Extruded) with density not less than
600kg/cbm outer layer (0.8-1mm)thick should be rigid PVC with density of not less than 1400kg/cbm. Door should be water proof,Termite proof ,fire retardant&having good RS: Four Thousand Five Hundred Thirteen
screw holding capacity.proviidng and fixing 100% Solid Wood Plastic composite(WPC) Door Frame 90mmx45mm made from wood plastic composite(single Extruded only
Process)material with density 780kg/cbm .all as per specifications drawing as directed by the engineer in charge.
Providing and fixing standard extruded of alluminium section of size 63 * 38.10 * 1.2 mm,@Wt 0.643 Kg/RMT )with colour aNOdized alluminium frame for ventilation with RS: One Thousand One Hundred Sixty Three
5 mm thick frosted glass as details etc complete FOR VENTILATION and Paise Ninty Two only
Providing & Laying integrated cement based proprietary water proofing treatment of required thickness over the roof including 10mm thick cement mortar 1:3 and CHINA
MOSAIC fitting and finally finishing the surface with white cement slurry and sloping out terrace slabs withFollowing specification laid to required slope not flatter than 1:80 (
the thickness of water proofing treatment near rainwater outlet or the lowest point of the finished slope shell not to be less than 45 mm. Including treating the vertical
surface of the parapet wall up to 20 cm. height above finished level of terracing including finishing top with joint less water proofing plaster curing testing etc, completed.
Rate is Including 10 years performance of guarantee bond to be given on stamp paper ( no extra shall be paid for increase in thickness for proper slope ). (A) Applying &
grounting a slurry coat of neat cement using 2.75 kg/smt. of cement admixed with proprietary water proofing compound confirming to IS 2645 and 10mm. Thick water
RS: Eight Hundred Fifty Five and Paise Eleven
102 proofing cement plaster in cement mortar in 1:3.over the RCC slab including cleaning the surface before treatments. (B) Laying cement concrete using broken brick bat 626.00 SMT 855.11
using 25 mm to 40 mm size with 50% of cement mortar 1:4 ( 1 cement : 4 corse sand )over 10mm. thick water proofing cement plaster in cement mortar in 1:3 admixed
with proprietary water proofing compound conforming to IS 2645 required slope and treating similarly the adjoining walls up to 200 mm height including rounding of
junction of walls.(C) After two days of proper curing applying a second coat of cement slurry .(D) Finishing the surface with china mosaic peices laid on 10 mm thick joint
less cement mortar of mix 1:3 ( 1 cement : 3 sand) admixed with proprietary water proofing compound confirming to IS 2645 and finally finishing the surface with trowel
with neat cement slurry .(E) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing for final test. All above operation to be
done in order and as directed and specified by the engineer in charge.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and laying 24" x 24" Double Charge vitrified 8 to 10 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new
RS: One Thousand Four Hundred Forty and
103 surface orfixing on existing flooring by adhesive including dismentaling of existing flooring and material jointed with color cement slurry including finised with flush pointing 1909.00 SMT 1440.20
Paise Twenty only
& cleaning the surface etc. complete for light shade
Providing and laying 24" x 24" Double Charge vitrified 8 to 10 mm thick tile for skirting,risers of steps and dedo over 20 mm (average) base of cement mortar 1:6 (
RS: One Thousand Three Hundred Ninty Two
104 cement: 6 coarse sand) on new surface orfixing on existing flooring by adhesive including dismentaling of existing flooring and material jointed with color cement slurry 123.00 SMT 1392.20
and Paise Twenty only
including finised with flush pointing & cleaning the surface etc. complete for light shade
Providing and laying Anti skid Ceramic tiles (Non Skiding) 8 mm to 10mm thick in Floorings, treads of steps and landing laid on a bed of 20 mm thick cement mortar 1:3 (1 -
RS: Nine Hundred Sixty and Paise Forty
105 cement: 3- coarse sand) finished with flush pointing in the colour as specified etc. complete in white cement for All Floors. Size and shade shall be as per the instruction of 207.00 SMT 960.47
Engineer - In - Charge.
Providing and laying Ceramic tiles 8 mm to 10mm thick in skirting, risers of steps and DADO on 10mm thick cement mortar 1:3 (1-cement: 3 coarse sand) finished with
RS: One Thousand Ten Hundred Twenty Eight
106 flush pointing in the colour as specified etc. complete in white cement for All Floors. Size and shade shall be as per the instruction of Engineer - In - Charge. The Tile size 789.00 SMT 1028.11
and Paise Eleven only
shall be 600mm x 300mm.
Finishing Wall with Plastic Emulsion Paint on Wall Surface (two coats) to give an required shap even shade after throughly brushing the surface to remove all dirt and
remains of loose poweder material etc. complete. Rate are inclusive of applying two coat of lapy (Putty) and one coat of primer on new wall surface to give and even shade RS: One Hundred Seventy Six and Paise
including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. putty , primer and paint make as per the approved Thirty Three only
list of GSPHCL.
Providing & Fixing 15mm One way Bib Tap with Wall Flange. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, RS: Nine Hundred Ninty and Paise Sixty One
Specifications and as per the Instruction of Engineer In charge. The Model & Make of Bib Tap Shall be as per the Approved Make List of GSPHCL. only
Providing & Fixing Two way Bib Tap with Wall Flange. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, RS: One Thousand Three Hundred Nine and
Specifications and as per the Instruction of Engineer In charge. The Model & Make of Two way Bib Tap Shall be as per the Approved Make List of GSPHCL. Paise Thirty Nine only
Providing & Fixing Health Faucets (ABS Body). Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and RS: Five Hundred Sixty Five and Paise Fifty
as per the Instruction of Engineer In charge. The Model & Make of Health Faucets Shall be as per the Approved Make List of GSPHCL. One only
111 Providing and laying G.I.RAIN WATER SPOUT of 50 mm dia and 0.30 m length. 40.00 NO. 100.90 RS: One Hundred and Paise Ninty only
Providing & Fixing Single Hole Wash Basin with C.I or M.S. brackete & M. I. fisher union, P.V.C water pipe with Connection from Stop Cock to Pillar Tap, PVC Bottle Trap
with Connection 32mm dia. C.P. brassa waste coupling etc. Complete. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed RS: Three Thousand Nine Hundred Thirty Five
Drawings, Specifications and as per the Instruction of Engineer In charge. The Model & Make of Wash Basin Shall be as per the Approved Make List of GSPHCL. including and Paise Thirty Three only
pillar cock, angel cock, bottale trap
Constructing of COUNTER BASIN PLATE FORM (SAND WITCH TYPE) 60cm width and 80cm high resting on thick sandwiched polish kota stone in C.M 1:3 with providing
and fixing 25 mm thick rough kota stone at bottom and 18mm thick GRANITE stone/ granite stone (single piece) 18mm thick on top with 15mm high machine cut granite RS: Four Thousand Five Hundred Forty Six and
round moulded facia patty including moulding & polishing etc. complete as per drawing and specification without wash basin including necessary cutting for wash basin. If Paise Ninty only
need the vertical support/ partition either single or sandwich type of polished kota stone (Polished on exposed sides) shall be provided as per detailed drawing.
Provinding and fixing 600mm x 450mm bevelled edge MIRROR or superior glass mounted on 6mm thick A.C. sheet of plywood sheet fixed to wooden plugs with C.P. RS: Eight Hundred Twenty Five and Paise
brass screws & washers. Forty Eight only
Providing & Fixing Towel Ring. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the
115 38.00 NO. 909.08 RS: Nine Hundred Nine and Paise Eight only
Instruction of Engineer In charge. The Model & Make of Towel Ring Shall be as per the Approved Make List of GSPHCL
Providing & Fixing Towel Rod. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the RS: One Thousand Seventy Eight and Paise
Instruction of Engineer In charge. The Model & Make of Towel Rod Shall be as per the Approved Make List of GSPHCL. Seventy only
providing and fixing SS cloth HANGER (5 hook ) as per detailed drawing and as directed by engineering incharge. Rate are inclusive of all material,labour, taxes. As per RS: Two Hundred Forty Nine and Paise Eighty
approved list of GSHPHCL Five only
118 Painting Numbers or name on Acrylic plate as Directed by Engineer in Charge. 94.00 NO. 100.00 RS: One Hundred only
RS: Two Hundred Eleven and Paise Eighty
119 Providing a I.S.I. mark 7 lavers three keys brass pad lock of NAVTRAL (godrej) make 65mm dia on completion of porject. 75.00 NO. 211.86
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing,fabrication and fixing M.S. Grill / GATE of approved pattern fabricated from M.S. flats,square bars,round bars,C channel ,square/round box pipe as per detail
drawings.Rate is inclusive of welding with griding and applying of mild steel putty with hardener into groove to have smooth surface,two coats of oil paint and one coat of
120 yellow zinc chromate primer coat of approved brand only.oil paint shall be luxol enamel paint of berger paint india limited or asian paint apcolite premium gloss enamel of 84299.75 KG. 74.92 RS: Seventy Four and Paise Ninty Two only
asian paint or dulux premium gloss enamel of dulux paint and nerolac sythetics enamel of nerolac paint for all foor and at any height only.M.S Grill/Gate material should
be ISI mark only.
Providing and fixing chicken wire mesh jali of 20 guage with necessary screws and nails at joints or crackes of brick work or RCC work, as per drawing, spicification and
121 789.00 SMT 64.06 RS: Sixty Four and Paise Six only
direction of Engineer in charge.wire-mesh jali shall confirm to relevant IS specification.
Providing and Fixing Granite Telephonic Black Colour 15 to 18 mm thick for jambs and sills of doors & windows using neat cement slurry laid over 20 mm average base of
RS: Two Thousand Four Hundred Twenty Eight
122 cement mortar 1:1(1 cement:1 Coarse Sand) and jointed with grey cement slurry including racking(Tancha Work) rubbing and polishing,scaffoldings,tools and 414.00 smt 2428.00
tackles,scaffolding etc. complete(with base of neat cement) as per direction of Engineer in charge including rounding the exposed edges as directed.
Provinding and Laying 18 mm thick Granite Stone Slab Flooring over 20mm thick average base of C.M. 1:6 (1cement : 6 coarse sand) laid and jointed with grey cement RS: Two Thousand One Hundred Thirty One
slury including Rubbing and Polishing etc. Complete for All Floors. and Paise Ninty Eight only
Providing and fixing both side polished machine cut Granite Shelves / Partitions 18mm thick embaded in to wall at support including racking and finishing smooth the RS: Two Thousand One Hundred Fifteen and
surface including cutting the stone as and where required etc. complete including rounding of exposed edges etc. complete. Paise Forty only
Providing & Fixing Wall Hung with PVC Flush Tank, Soft Seat Cover & intergal "P" or "S" Trap including Jointing the Trap with Pan and Soil pipe. Wall hung shall be fixed
on S.S heavy duty rack bolt having 16mm dia, 165mm length using Plastic sleeve Make by Using Drill Bitt Only. Rate are inclusive of all materials, Labour & Necessary RS: Five Thousand Four Hundred Seventy and
Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The Model & Make of Wall Hung & Flush Tank Shall be as Paise Ninty only
per the Approved Make List of GSPHCL.
Providing & Fixing Shower with Arm. Rate are inclusive of all materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the RS: Nine Hundred Thirty One and Paise
Instruction of Engineer In charge. The Model & Make of Shower with Arm Shall be as per the Approved Make List of GSPHCL. Seventy Nine only
127 Providing , carving & Fixing of a Granite takti of size 0.30mtr x0.30mtr as per instruction of Engineer Incharge. 1.00 Nos 1000.00 RS: One Thousand only
S.S. Railing Providing and fixing of stainless steel 304 grade pipe railing 0.90m height. Top round pipe (Baluster) of 2" dia. Vertical balustrade 1.5" x 1.5" at every max.
0.90m c/c and intermediate 3 nos. runners pipe midrail of 1" dia and SS base plate of 100 x 8mm. The railing system shall be floor mounted with anchor fastener and base RS: Three Thousand One Hundred Forty Three
plate of 100mm size having 8mm thickness completed as per detailed drawing & as directed by engineer in charge. Rate are inclusive of all material, labour, taxes & and Paise Forty Three only
Providing and Fixing of stainless steel 304 grade pipe railing.0.9 mtr. Height top pipe of 2" dia , vertical balustrade 1.0 " x1.0" at every max. 0.9 mt c/c, fixed with RS: Nine Hundred Eleven and Paise Three
stone/concrete or brickwork, Balustrade as directed by engineer in charge. Rate are inclusive of all material,labour,taxes &polishing. only
providing and fixing 6 mm thick lexan polycarbonate multi wall roofing sheet fixed with hilti screw and rubber silicon sealer and alluminium strip of 50x3 mm etc complete RS: One Thousand Four Hundred Twenty Seven
as directed by engineering in charge and Paise Sixty Two only
RS: Six Hundred Sixty Five and Paise Fifty
131 Providing & Fixing Heavy duty stopcock/ ANGLE COCK 15mm dia. with Wall Flange oF All Neccery Fittings. 56.00 NO 665.51
Providing & Fixing 15mm Concealed Heavy Duty Stop Cock with Exposed Part & Other Accessories (Sleeve, Lever, Wall Flange). Rate are inclusive of all materials,
RS: Nine Hundred Forty Two and Paise Fifty
132 Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The Model & Make of Concealed 17.00 NO 942.54
Heavy Stop Cock Shall be as per the Approved Make List of GSPHCL.
Providing and Fixing concealed centre point to wall ceiling and floor CPVC ( SDR 13.5) poipe having National sanitation foundation ( NSF) seal for potable water of
RS: Two Hundred Two and Paise Ninty Seven
133 following dia. Nominal bore tube fittings and clamps including, making good the wall,ceiling and floor etc complete.Pipe shall be concealed or open as per mentioned in 192.00 RMT 202.97
tender description.Pipe shall be approved make of GSPHCL list (20 mm inside dia).
Providing and Fixing concealed centre point to wall ceiling and floor CPVC ( SDR 13.5) poipe having National sanitation foundation ( NSF) seal for potable water of
RS: Two Hundred Forty Seven and Paise
134 following dia. Nominal bore tube fittings and clamps including, making good the wall,ceiling and floor etc complete.Pipe shall be concealed or open as per mentioned in 320.00 RMT 247.25
Twenty Five only
tender description.Pipe shall be approved make of GSPHCL list (25 mm inside dia).
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
RS: Three Hundred Thirty and Paise Thirty
135 following dia. nominal bore tube fittingswith Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply pipe. Pipe shall be concealed or 192.00 RMT 330.36
open as mention in tender description. Pipe shall be as per approved make of GSPHCL make list (32 mm inside dia).
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
RS: Four Hundred Thirty Seven and Paise
136 following dia. nominal bore tube fittingswith Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply pipe. Pipe shall be concealed or 254.00 RMT 437.66
open as mention in tender description. Pipe shall be as per approved make of GSPHCL make list (40 mm inside dia).
Providing and fixing concealed or open center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
RS: Six Hundred Forty Seven and Paise Thirty
137 following dia. nominal bore tube fittingswith Z patti (Minimum 1.6mm thick) with 6mm Dia U Clamp with washer for Vertical water supply pipe. Pipe shall be concealed or 122.00 RMT 647.30
open as mention in tender description. Pipe shall be as per approved make of GSPHCL make list (50mm inside dia).
Providing and fixing to wall, ceiling and floor SWR/UPVC soil waste pipe 75 mm dia. Of ISI13592/92 . Rate inclusive of all fittings like single or double 'Y' with door,
RS: Two Hundred Sixty Four and Paise Ninty
138 reducer, coupler single T with door bend, pipe clip on z patti etc. complete and making good the wall, ceiling and Floor. Including Z-patti G.I Sloated Min 1.6 Mm Thick 331.00 RMT 264.97
Providing and fixing to wall, ceiling and floor SWR/UPVC soil waste pipe 110 mm dia. Of ISI13592/92 . Rate inclusive of all fittings like single or double 'Y' with door,
RS: Four Hundred Ninty Five and Paise Ninty
139 reducer, coupler single T with door bend, pipe clip on z patti etc. complete and making good the wall, ceiling and Floor. Including Z-patti G.I Sloated Min 1.6 Mm Thick 310.00 RMT 495.91
140 Providing and fixing in position UPVC/SWR cowel vent to pipe 75mm dia as directed. 11.00 NO 16.47 RS: Sixteen and Paise Forty Seven only
141 Providing and fixing in position UPVC/SWR cowel vent to pipe 110mm dia as directed. 10.00 NO 28.16 RS: Twenty Eight and Paise Sixteen only
Provinding and fixing gun metal check or non return full way WHEEL / HANDLE VALVE 50 mm dia. Rate are inclusive of all materials, Labour & Necessary Fittings etc. RS: Two Thousand Three Hundred Two and
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. All material used as per approved make list by GSPHCL. 50 mm dia. Paise Thirty Three only
Provinding and fixing gun metal check or non return full way WHEEL / HANDLE VALVE 40 mm dia. Rate are inclusive of all materials, Labour & Necessary Fittings etc. RS: Six Hundred Fifty Six and Paise Eighty Six
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. All material used as per approved make list by GSPHCL. 40 mm dia. only
Provinding and fixing gun metal check or non return full way WHEEL / HANDLE VALVE 25 mm dia. Rate are inclusive of all materials, Labour & Necessary Fittings etc. RS: Four Hundred Sixteen and Paise Forty
Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. All material used as per approved make list by GSPHCL 25 mm dia. Seven only
Constructing of cooking platform ( sandwich type ) 60cm width and 80cm high resting on thick sandwiched polish Granite Slab in C.M 1:3 with providing and fixing 25 mm
thick rough kota stone at bottom and 20 to 25 mm thick Polish Granite stone ( single piece/ telephonic Black ) top and polished granite stone (single piece/ telephonic Black RS: Three Thousand Seven Hundred Fifty Seven
) 20 to 25mm thick on top with 15mm high machine cut polished granite round moulded facia patty including polishing etc . complete as per drawing and specification and Paise Fifty Seven only
without stainless steel sink including necessary cutting for sink & making hole for gas pipe and fixing P.V.C bend of 25mm dia.
Providing and Fixing Stainless Steel ( 304 Grade ) 1mm thick Matt / Satin Finish Kitchen sink of over all Minimum size 533mmx 457mm X 203mm deep having bowl
RS: Four Thousand Two Hundred Sixty Nine
146 Minimum size 470mm x 395mm x 203mm with cement mortar 1:3 etc.complete.Rate including of 32mm dia.C.P.brass waste coupling and 32mm dia. rigid PVC waste pipe 4.00 NO 4269.00
upto N.T. approved GSPHC make list.
Providing & fixing PVC SWR MULTY NANHI TRAP IS:14735 for drain -100mm dia. With jali of following nominal dia. of self cleansing design with C.I. Screwed down or
Hinged grating including the cost of cutting and making good the walls. Providing & Fixing Floor drain jali (Glossy Finish) (on N.T.) of 6" X 6"size made of Stainless Steel RS: One Thousand One Hundred Twenty Two
Grade 304 Floor Drain 3 Piece (Cover/Jali/Grating) With Anti Cockroach Bowl on N.T. Rate are inclusive of all necessary fittings, material, labour etc.complete as per and Paise Twenty Six only
direction of Engineer In charge.
RS: Eight Hundred Eighty Five and Paise Fifty
148 Providing, supplying & fixing stainless steel letters 30cm height & 4.5cm wide etc. complete as directed. 60.00 NO 885.50
Providing & Fixing Urinal with P.V.C water pipe, 32mm dia. C.P. brassa waste coupling with Connection 32mm dia waste Pipe etc. Complete. Rate are inclusive of all
RS: Two Thousand Ninty Eight and Paise Ninty
149 materials, Labour & Necessary Fittings etc. Complete as per Detailed Drawings, Specifications and as per the Instruction of Engineer In charge. The Model & Make of 13.00 NO 2098.98
Urinal Shall be as per the Approved Make List of GSPHCL.
Providing and fixing in position PVC water tank of approved quality and size on terrace including making inlet and outlet, over flow and washout arrangement with G.I.
150 Connection including using necessary material and labour for connection etc. complete with closed cover as per drawing and specification. Rate inclusive of Providing & 20000.00 LTR. 3.91 RS: Three and Paise Ninty One only
applying two coats of oil paint on outside of water tank Joint shall be sealted by Pipe sealent.
Providing and laying R shaped baffle galvanised steel 55 R Panel with 25mm clear gap between two panel plain exterior claddding system with super coat powder coat RS: One Thousand Six Hundred Forty Seven
onvisible surface of panels and structure black coated syastem and Paise Forty only
supplying j and installation of GRC jali thickness 25mm , grade M-40 ,Flexural M8 , Backside double coated frame fabrication at site including installation at site, RS: Seven Thousand Three Hundred Seventy
transportation loading , unloading all with both sides weather proof emulsion paint etc complete as directed by EIC (For NRB Elevation Only) Nine and Paise Ten only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter locked to gether their entire length and jointed together at the end locks
RS: Four Thousand Four Hundred Fifty and
153 mounted on specially designed pipe shaft with bracket plates,guide channels and outside locking with push-pull operation including the cost of Hood cover and spring etc 24.00 SMT 4450.51
Paise Fifty One only
comp.(B)Shutters having width 3.5 met and above
Providing and fixing Rubber Speed Breaker 500*350*50 mm(2 piece in 1 meter) (1 no. yellow & 1 no.black)Installation With 4 Inch Zink Plated 12 mm Bolt With Epoxy RS: Six Hundred Ninty Five and Paise Ninty
Hardner.etc complete as per direction of Engineer incharge. Three only
RS: Five Hundred Forty Four and Paise Ninty
155 Demolition of brick work & stone masonary incl. stacking of servicable material and disposal of unservicable material with disposing all lead and lift. (iii)In cement mortar 66.00 CMT 544.95
RS: One Thousand Forty Seven and Paise
156 Demolition including stacking of serviceable materials and disposal of unserviceable material with all lead and lift (i)R.C.C. work 66.00 CMT 1047.38
Thirty Eight only
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Four Thousand Five Hundred Ninty Five
157 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in Foundation Footing and Mass concrete. for any cross 28.00 CMT 4595.51
and Paise Fifty One only
sectional area of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Nine Thousand Fourteen and Paise
158 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in COLUMN upto PLINTH for any cross sectional area of 8.00 CMT 9014.12
column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Seven Thousand Fifty Two and Paise
159 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in plinth Beam.for any cross sectional area of column. Rate are 9.00 CMT 7052.93
Ninty Three only
also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-200 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Five Thousand Nine Hundred Eleven and
160 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in Copping.for any cross sectional area of column. Rate are also 10.00 CMT 5911.20
Paise Twenty only
inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-200 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Eight Thousand Nine Hundred Seventy Four
161 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in Columns for Ground Floor.for any cross sectional area of 13.00 CMT 8974.83
and Paise Eighty Three only
column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding 20 mm thick SAND FACED cement PLASTER on walls above ground level consisting 12 mm thick backing coat of C.M. 1: 3 ( 1 cement : 3 sand ) and 8mm RS: Two Hundred Ninty Seven and Paise Sixty
thock finishing coat of C.M. 1:1 ( 1 cement : 1 sand ) etc. Complete for any height.) Eight only
Providing & Fixing 600mm dia. loop hot dip galvenised iron concertina coil made out of 2.5mm dia wire 22mm long razor sharp barbs at 35mm center fitted on 40mm x
40mm x 5mm M.S. Angle post of required shape & size at 3.00 mt. center distance. concertina coil shall be fixed on M.S. Angle stand with the help of 4 Nos. RBT wire
163 161.00 RMT 632.00 RS: Six Hundred Thirty Two only
M.S. Angle stand shall be fixed on top of Compound wall with 0.20mt x 0.31mt x 0.40mt. deep block in controlled cement concrete M-250. Rate is including of applying one
coat of primer and three coats oil painting on M.S. Angle stand shall be made as per the drawing supplied or as directed by engineer in charge.
Providing and filling the expansion joint by Thioflex 600 polymer or equivalnt confirm to BS 4254-1983 as per required shade and manufactured specification by making
RS: Five Hundred Ten and Paise Twenty Nine
164 groove of 50 mm X 12.5 mm lather by cutting or by repairing groove and removing mortar drop or any other foreign materials including applying primer and filling required 5.00 SMT 510.29
size ( over size) of joint PU foam etc. complete
RS: Two Hundred Eighty Six and Paise
165 Filling In Foundation & Plinth With Murrum Or Selected Soil In Layers Of 20Cms Th. Inclu.. Watering , Ramming & Consolidating Etc.. Complete 314.00 CMT 286.20
166 Providing & Laying lawn for Land Scaping including watering & all labours 150.00 SMT 150.00 RS: One Hundred Fifty only
Providing & Laying tree plantation rate are also inclusive of maintaing the tree plant in live condition at the time of completion of work at the time of Excavation of the
167 78.00 No. 600.00 RS: Six Hundred only
building i.e. initial starting time (the tree shall be minimum 1.50mt height).
Provding and fixing pre-cast Rubber Dye/ steel Dye inter locking concrete block 60 mm thick with grade of concrete M-300 pnumatic compressed / Vibrated mechanically
168 pressed and as per approved design and IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per guidlines of 245.00 SMT 680.10 RS: Six Hundred Eighty and Paise Ten only
IRC : SP 63-2018 etc. complete.
Providing and fixing Precast Concrete Kerb Stone of Grey Cement Based Concrete Block size of 30 cm Length, 30 cm Height and 15 cm thick of M-250 Grade Concrete
RS: Three Hundred Fifty Eight and Paise Six
169 as per approved design in required colour (Red, White, and Yellow) and Including Excavation For Fixing In proper Line And Level, Filling The Joint C:M 1:3 (1 Cement : 3 108.00 Rmt 358.06
Fine Sand) etc. Complete.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and Corrugated JSW pre coated sheet roofing fixed with galvanized iron J or L hooks,bolts and nuts 8mm diameter with bitumen and G.I limpet washer or G.I RS: Nine Hundred Seventy Seven and Paise
limpet washer with white lead complete excluding the cost of purlins,rafters and trusses. (0.60mm thick) Thirty Eight only
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Seven Thousand Seven Hundred Two and
171 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in SLAB having thickness of 13cm upto 15cm. FOR GROUND 11.00 CMT 7702.61
Paise Sixty One only
FLOOR..for any cross sectional area of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Drilling and reaming of 400/450mm bore hole in alluvials starta by given 300mm dia pilot bore hole including assembling lowering hoising casing pipes stainer pipe with
172 50.00 Rmt 870.00 RS: Eight Hundred Seventy only
gravel packing etc complete.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, RS: Six Hundred Fifty Four and Paise Twelve
including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. pipe size : 150 mm only
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including RS: Six Hundred Sixty Five and Paise Eighty
hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. Pipe size : 150 mm Five only
RS: Two Thousand Eight Hundred Three and
175 Material charge for the bore inclding labor & materials PVC bore plug/ Cap plug, clamp having lenth of 0.45 mt as per IS for 150 mm dia pipe 1.00 No 2803.62
Paise Sixty Two only
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm
RS: One Thousand One Hundred Fifty Four and
176 dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with 1.00 No 1154.40
Paise Forty only
M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt RS: Two Hundred Forty Six and Paise Twenty
ends prepared for collar joints including testing of joints complete.(B) 150mm One only
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt RS: Three Hundred Forty Four and Paise Fifty
ends prepared for collar joints including testing of joints complete..(C) 250mm Nine only
Construction of BRICK MASONRY CHAMBER for under Ground C.I. inspection chamber and bends with bricks having crushing strength not less than 35 Kg / Cm2 in
Cement Mortar (1:5) with RCC top slab with CC (1:2:4) mix ( 1 cement : 2 corse sand : 4 gradded aggregate 20 mm nominal size) with 8mm. dia. TMT steel at 15 cm. c/c
both ways & providing and fixing precast r.c.c cover size .60 x .45 x .07 mt. with angle frame fixed with C.C (1:2:4) Foundation concrete 1:5:10, inside plaster 15 mm thick RS: Three Thousand Seven Hundred Ninty
with C:M (1:3) finished smooth with a floating coat of neat cement slurry on walls & bedconcrete etc, complete. Inside dimension of chamber 455 mm x 610 mm x 450 mm Three and Paise Eighteen only
deep for match proposed pipe line. Rate are also inclusive of out side plaster 15mm. th. in c:m 1:3 from top of the chamber & all side up to 15 mm. deep below ground
Construction of BRICK MASONRY CHAMBER for under Ground C.I. inspection chamber and bends with bricks having crushing strength not less than 35 Kg / Cm2 in
Cement Mortar (1:5) with RCC top slab with CC (1:2:4) mix ( 1 cement : 2 corse sand : 4 gradded aggregate 20 mm nominal size) with 8mm. dia. TMT steel at 15 cm. c/c
both ways & providing and fixing precast r.c.c cover size .60 x .45 x .07 mt. with angle frame fixed with C.C (1:2:4) Foundation concrete 1:5:10, inside plaster 15 mm thick RS: Five Thousand Four Hundred Seventy Six
with C:M (1:3) finished smooth with a floating coat of neat cement slurry on walls & bedconcrete etc, complete. Inside dimension of chamber 610 mm x850 MMX 450 mm and Paise Ninty Three only
deep for match proposed pipe line. Rate are also inclusive of out side plaster 15mm. th. in c:m 1:3 from top of the chamber & all side up to 15 mm. deep below ground
RS: One Thousand Four Hundred Forty and
181 Supplying and filling in foundation and plinth with RUBBLE including filling voids with sand and watering etc.complete. 22.00 CMT 1440.63
Paise Sixty Three only
Provinding and laying Controlled cement concrete M-300 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Eight Thousand One Hundred Forty Five
182 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in WALLS HAVING ANY CROSS SECTION ARE OF WALL . 26.00 CMT 8145.57
and Paise Fifty Seven only
FINS FOR SUMP for any cross sectional area of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Ten Thousand Four Hundred Four and
183 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in Columns for Ground Floor.for any cross sectional area of 5.00 CMT 10404.22
Paise Twenty Two only
column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Eight Thousand Seven Hundred Fifty Nine
184 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in BEAM. FOR GROUND FLOOR..for any cross sectional area 7.00 CMT 8759.31
and Paise Thirty One only
of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Eight Thousand One Hundred Twenty Six
185 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in SLAB having thickness of 10cm upto 13cm. FOR GROUND 10.00 CMT 8126.50
and Paise Fifty only
FLOOR..for any cross sectional area of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Provinding and laying Controlled cement concrete M-250 and finishing smooth with curing etc. complete including the cost of formwork of Plywood only with fair finish &
RS: Eight Thousand Four Hundred Forty Eight
186 Proping must be of steel only so as to give fair finish but excluding the cost of reinforcement for RCC work in R.C.C LINTELS FOR GROUND FLOOR..for any cross 1.00 CMT 8448.87
and Paise Eighty Seven only
sectional area of column. Rate are also inclusive of providing and mixing Plasticiser of approved make in proportion as per mix design.
Providing and laying controlled cement concrete M-250 for reinforcement concrete CHAJJAS.not exceeding 10cm thickness up to floor two level including finishing the
exposed surface with cement mortar 1:3 ( 1 cement : 3 fine sand) to give a smooth surface. Including the cost of form work of Plywood only with fair finish & Proping must RS: Nine Thousand Four Hundred Thirty Six
be of steel only so as to give a fair finish. complete excluding cost of reinforcement Rates Are Inclusive Of Providing & Mixing Plasticizer Of Approved Make & In and Paise Nine only
Proportion As Prescribed By The Manufacturer FOR ALL FLOOR
188 Provinding CEMENT VATA ( 10cm x 10cm )size quarter round in cement mortar 1 : 1 including neat cement finishing, watering etc. Complete. 760.00 RMT 23.45 RS: Twenty Three and Paise Forty Five only
Providing and Laying Mirror Polished 25 mm thick Double Diamond Polished Kota Stone Flooring over 20mm thick base of cement mortar 1 : 6 (1-Cement : 6-Coarse
RS: One Thousand Eighty One and Paise Ninty
189 Sand) laid over and jointed with grey cement slurry including Rubbing and Polishing etc. Complete. (A) 25mm Thick. In Green Colour. Rate Are Inclusive of Single Piece & 584.00 SMT 1081.90
Making 3 Line Groove and Moulding Of Outer edge as Directed By Engineer In Charge.
Providing and Laying Mirror Polished 25 mm thick Double Diamond Polished SLAB in RISERS of steps, dedo , skirting and pilllars laid to 10 mm thick cement mortar 1:3 RS: One Thousand Two Hundred Seventy Five
( 1 cement : 3 coarse sand) & jointed with grey cement slurry including rubbing & polishing etc and Paise Ten only
Provinding and Laying 25mm thick Machine Cut Rough Kota Stone Flooring over 20mm thick base of C.M. 1 : 5 (1-cement : 5- coarse sand ) including pointing with C.M. 1 RS: Seven Hundred Five and Paise Thirty
: 2 (1-cement : 2- stone dust ) etc. Complete. (A) 25mm thick. Nine only
Finishing Ceilling/Slop Surface with Plastic Emulsion Paint on Ceilling/Slop Surface (two coats) to give an required shap even shade after throughly brushing the surface to
remove all dirt and remains of loose poweder material etc. complete. Rate are inclusive of applying two coat of lapy (Putty) and one coat of primer on new Ceilling/Slop RS: One Hundred Eighty Six and Paise
Surface to give and even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.putty,primer & Seventy Three only
paint shall be as per approved list of GSPHCL
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) over and above applying One Coat Of Primer to give an required shape even shade RS: One Hundred Forty Seven and Paise Sixty
after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete. primer and paint make as per the approved list of GSPHCL Eight only
Providing & Fixing to Wall Ceilling and Floor SWR (Type B) Rain Water pipe as Per IS-13592 of 90mm Dia. Complete with Special Flings, vent cowl, Compressor type
Fittings like G.I. Slotted Z patti of 16 Gauge (minimum1.60mm thick) and minimum 6mm dia. U Clamp with Washer Nut at every 1.50mt. vertical distance including All RS: Three Hundred Twenty Three and Paise
Labour Charges etc. complete including making good the Ceilings, Floors and on terrace. Rain water pipe shall be 90 mm Dia. SWR horizontal pipe and vertical pipe and Fifteen only
90mm bend at the end near by Ground level. Rate are Inclusive of all Necessary Fittings required for ALL FLOORS.
Providing and fixing main outer size 95mm*24mm*1.17mm@ wt of 0.738 kg/rmt Aluminum Colour anodized section frame, horizontal Three track member size 92mm x
31.75mm x 1.30mm,@ Wt. 1.07 Kg/mt), vertical member of size 92mm x 31.75mm x 1.50mm ,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size 40 RS: One Thousand Five Hundred Sixty Eight
mmx18mm x1.29mm ,@ wtof 0.456 Kg/mt), vertical member of size 40mm x 18mm x 1.29 mm ,@ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze colour tinted float and Paise Twenty Seven only
glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details Both Side Locking Arrangment.
RS: One Hundred Sixty Two and Paise Twenty
196 Providing & fixing cast iron steps of size 500 x 150 x 22.5 mm & painting with two coats of anticorrosive paint etc. complete. 36.00 NO 162.23
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm nominal size) laid in one layer and finished with a floating RS: Three Hundred Forty Eight and Paise
coat of neat cement. (B)50mm thick Eight only
Providing and fixing S.W. Gully trap with C.I. grating brick masonry chamber & water-tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight. [I] RS: One Thousand One Hundred Seventy Six
Square mouth trap (B) 150mm x 100mm size P or R type. and Paise Ninty Four only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Constructing manhole with R.C.C. top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. Nominal size) foundation concrete 1:3:6 mix (1 cement
: 3 coarse sand : 6 Brick bats 40 to 50 mm. size) inside plastering 15mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm. nominal size) finished smooth complete including curing and RS: Ten Thousand One Hundred Sixty Seven
testing.(I) Inside size 900 mm. X 1200 mm. and 1:5 mt. Deep including C.I. Cover with frame size 560 mm. Total weight of cover and frame to be not less than 128 Kgs. and Paise Seventy Six only
(Wt. Of cover 64 Kgs and Wt. Of frame 64 Kgs)(A) With 230 mm. Thick walls of brick masonry using brick having crushing strength not less than 35 Kg/sq cm. In cement
mortar 1:5(1 cement : 5 coarse sand)
RS: Two Hundred Thirty Nine and Paise Ninty
200 Extra above item for addi. depth 0.10 mt. or part three of beyond 450 mm depth for brick masonry chamber 455 mm x 610 mm. 105.00 No 239.99
RS: Three Hundred Twenty Two and Paise
201 Extra above item for addi. depth 0.10 mt. or part three of beyond 450 mm depth for brick masonry chamber 600 mm x 850 mm. 25.00 Nos. 322.37
Thirty Seven only
RS: Five Hundred Seventeen and Paise
202 Extra above item for addi. depth 0.10 mt. or part three of beyond 1.5 mt depth for brick masonry chamber 0.900 mm x 1500 mm. 20.00 Nos. 517.78
Seventy Eight only
Providing, supplying and Fixing Corrugated DWC HDPE Pipes of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric
sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance etc. complete. (100mm ID Dia) Including
Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of
203 24.00 Rmt. 229.00 RS: Two Hundred Twenty Nine only
coupler ( on line / off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot
end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth & alignment ,testing the water tightness
of the joints, ensuring the continuity tests of specified pipe segments etc. complete as per drawing,specifications & detailed engineering, including carriage of pipes &
fittings from site stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing, supplying and fixing Corrugated DWC HDPE Pipes of Class SN8 Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric
sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as
per EN:13476-3 including all transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance etc. complete. (150 mm ID Dia) Including Lowering,
laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth Internal surface) Polyethylene Piping and fittings with the help of coupler ( on line /
204 149.00 Rmt. 396.00 RS: Three Hundred Ninty Six only
off line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the
same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient,depth & alignment ,testing the water tightness of the joints,
ensuring the continuity tests of specified pipe segments etc. complete as per drawing,specifications & detailed engineering, including carriage of pipes & fittings from site
stacks to the place of laying etc. as per direction of Engineer-in-charge.
Providing and laying (To level or slopes) and jointing reinforced concrete light duty, Non-pressure pipes I.S. class NP/2 of the following internal diameter with collars and RS: Six Hundred Fifty Eight and Paise Eighty
butt ends prepared for collar joints including testing of units complete. (a) 300 mm dia. Nine only
Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and disposing on the road side slope as RS: One Hundred One and Paise Ninty One
directed up to any lead. only
Construction of Granular Sub base by Providing Couarse graded material Spreading in uniform Layers With motor grader on prepared surface mixing by mix in place RS: One Thousand Four Hundred Forty One and
method with rotavator at OMC and Compacting with Vibratory roller to achieve the desired density complete as per table 400-2 Paise Twenty Eight only
RS: Nine Hundred Ninty Seven and Paise
208 Supplying of graded stone aggregate of following sizes (for W.B.M. Road) ( 3) Crushed stone aggregate for Hard Quality up to 63 mm stze 69.00 CMT 997.21
Twenty One only
Spreading the stone aggregate for rolling and W.B.M. including filling the interstices to required camber and gradient (excluding spreading of Blindage) (ii) 40mm to 63mm RS: Two Hundred Forty Seven and Paise
size aggreagates (H.B.) Twenty Eight only
RS: Two Hundred Ninty Two and Paise Forty
210 Supplying of murum on W.B.M surface etc. complete 9.00 CMT 292.40
RS: One Hundred Forty Six and Paise One
211 Spreading blidage or road crust filling the gaps in metal and leveling to cambert and gradient as directed .(i)Murrum 9.00 CMT 146.01
Rolling & consolidation water bound macadam (except laterite and kankar) including watering not exceeding 150mm thk. (Main layer incl. binding materials) includining
212 2745.00 SMT 20.79 RS: Twenty and Paise Seventy Nine only
filling in depression which occurs during the process. (A)with Power roller exceeding 8 tonne and not exceeding 12 tonnes
Construction Of Concrete Road Using Trimix System Having of any Thickness M-300 Ready Mix Concrete With Providing And Fixing & Removing Of "C" Channel
Having Size 75Mm. X75Mm As Per Required Level Slope And Thickness Of Concrete Road Floor Levelling Of Place Concrete With Surface Vibrator Machine,Dewatering RS: Four Thousand Five Hundred Twenty Six
System Device Finishing With Power Floater Machine And Trowel Light Brooming On The Surface As Directed With Providing Expansion Joint Size 20 X 190Mm. and Paise Sixty Four only
(Including hardner) Using Of Concrete Cutter Machine Including Curing Etc. Complete.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing and fixing pre- moulded compressible filler board in black colour confirming to MORT&H Specifications (Clause 1015). having minimum density 95kg/cum.metre,
RS: Seven Hundred Eighty Eight and Paise
214 non-staining with less than 1% water absorption & compression recovery of 93% minimum as per specification for 20 mm wide expansion joint including cutting to required 33.00 SMT 788.78
Seventy Eight only
size and shape at all levels etc. complete as directed.
Providing and fixing 25 mm diameter backup rod having minimum density 22 kg per cum (ASTMD - 3575) & compression strength of 0.40 kg per sqm (ASTM 5249) and
215 37.00 RMT 17.48 RS: Seventeen and Paise Forty Eight only
finishing with polysulphide sealant etc. complete. For 20 mm wide expansion joint
216 Providing Groove cutting in C.C. Road incluing cleaning etc.complete as per direction of Engineer incharge 472.00 RMT 36.80 RS: Thirty Six and Paise Eighty only
217 Providing & Laying sand & Bitumen filler in joints 10 & 25 mm 472.00 RMT 11.50 RS: Eleven and Paise Fifty only
218 Drilling of 250 mm dia pilot bore hole in all strata by using mud-flush direct rotary ring by using Bentonite powder 250.00 Rmt 595.00 RS: Five Hundred Ninty Five only
Reaming 250 mm dia pilot bore to 450 mm. dia hole including Assembling, Lowering Housing, Casing strainer pipe, gravel packing etc.completed. From 200 mm dia to
219 250.00 Rmt 275.00 RS: Two Hundred Seventy Five only
450 mm dia bore hole.
220 Conduction electrologing test of 300 mm dia. Bore hole incl. carting & idle-hour 1.00 JOB 18000.00 RS: Eighteen Thousand only
(A) Development of each water bearing zones comes/ across upto the full depth of tube well ( size 200/250/300 mm dia. depth more than 186 meter ) by lowuring 100 RS: Twenty Seven Thousand Four Hundred
mm dia drop line & 32 mm dia G.I. Ariline for each zone with suitable capacity air compressor upto the availability of sand free discharge ( Without air comp. charge) Forty Six only
RS: Eight Thousand Four Hundred Fifteen
222 (B) Development of above mentioned bore by air compressor 900 cfm./ 200 psi. capacity upto 6 hrs minimum until sand free discharge of the above which ever is latter. 6.00 Hrs. 8415.00
Providing M.S E.R.W plain end medium duty pipe confirming to I.s-4270/2001 with latest amenments in random length of 4 to 7 mt.as per GWSSB R/C (A)200MM DIA(min RS: Two Thousand Four Hundred Seven
6mm thick)TATA OR JINDAL MAKE only
Manufacture, supply and delivery of Cage type trapezoidal shape ("V"') wire wound low carbon, galvanized screen pipe and stainless steel screen pipes, confirming to IS:
RS: One Thousand Six Hundred Sixty Six
(B)200mm dia grade regular (1) 1.00 mm slot size
225 Supply of Gravel having size 4 mm to 6 mm size. 21.00 Cmt 2029.00 RS: Two Thousand Twenty Nine only
226 Supply of clay ball made from sticky clay of size 15 mm to 25 mm & quality certified by Hydrologist. 20.00 Cmt 751.00 RS: Seven Hundred Fifty One only
Bore plug having 100mm height made from M.S . Plate with 3 holes at equal distance on circumference for nut-bolts& lock nuts of std. make complete .from 5 thick m.s RS: Seven Hundred Seventy Four and Paise
plate (for top also) suitable for 200mm dia pipe. Eighty Two only
228 Supply of portland cement 1.00 M.T 6302.00 RS: Six Thousand Three Hundred Two only
RS: Thirteen Thousand Two Hundred Seventy
229 Cement sealing as recommended by Hydrologist ( without cost of cement & by means mud pump ) 1.00 Job 13273.00
Providing and fixing Single headed internal hydrant having outlet of 63 mm dia(2.1/2”) N.B. hydrant (IS:5290) (Type-A) landing valve in SS Morris Pattern instanteous RS: Six Thousand Eight Hundred Eighty Six and
coupling type with required hardwares. Paise Seventy Two only
Providing & fixing 63mm dia 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wires, revates etc. confirming to IS 636 (typa-A) as
RS: Three Thousand Nine Hundred Sixteen and
231 required 9.00 No. 3916.23
Paise Twenty Three only
Stainless steel (grade 304)
Providing, fixing, testing and commissioning of Weather proof standard fire Hose Cabinet fabricated from 18 guage sheet, floor mounting type having Double Opening with
232 10.00 No. 5100.00 RS: Five Thousand One Hundred only
M.S. Fabricated Stand, necessary locking arrangement by allan key. (750x600x250mm)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, confirming to IS 884 complete with the following as required.25 mm nominal
RS: Seven Thousand Nine Hundred Twenty and
233 int. dia. Water hose thermoplastic (Textile reinforced) type-2 as per IS12585, 25 mm nominal internal dia gun metal globe valve and nozzle.Drum and brackets for fixing 8.00 No. 7920.84
Paise Eighty Four only
the equipment of the wall. Connections from risers with 32 mm dia stop gun metal valve & MS pipe and socket.30 m
Providing, fixing and testing of Air Vessel made of 250 mm dia, 8 mm thk sheet, 1200 mm in height with air release valve in top & connection to riser, drain arrangement RS: Sixteen Thousand Two Hundred Seventy
with 25 mm GM wheel valve with required accessories, pressure gauge, painting, etc. compelte Nine and Paise Thirty Five only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
RS: Two Thousand Eight Hundred Fifty Four
235 Providing and fixing of 63 mm SS branch pipe nozzle conforming to IS 903, suitable for instantaneous connections to hose coupling etc. as required 8.00 No. 2854.62
and Paise Sixty Two only
Supplying and fixing specially designed SS 304 orifice plates (minimum 6 mm plate thickness) to be fitted between flange and landing valve of external & internal hydrant RS: One Thousand Two Hundred Four and Paise
outlets of hydrant valves for reducing delivery pressureto 3.5 kg/ sq.cm at hydrant valve Seventy Nine only
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground
including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive pipe protection Bituminous tape with
black anti corrosive paint as per IS 10221, refilling the trench etc. of following sizes complete as required.
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground
RS: Four Thousand Two Hundred Eighty Two and
237(A) including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive pipe protection Bituminous tape with 141.00 Mtr. 4282.61
Paise Sixty One only
black anti corrosive paint as per IS 10221, refilling the trench etc. of following sizes complete as required. Size : 150 mm NB
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground
RS: Three Thousand Four Hundred Forty Five and
237(B) including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive pipe protection Bituminous tape with 12.90 Mtr. 3445.02
black anti corrosive paint as per IS 10221, refilling the trench etc. of following sizes complete as required. Size :100 mm NB
Providing, laying, testing and commissioning of the 'C’ class MS Pipe as per IS1239/3589 i/c fittings like elbows, tees, flanges, tappers, nuts, bolts, gaskets etc. in ground
RS: Two Thousand Eight Hundred Fifty Four and
237( C) including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with 4 mm thick anti corrosive pipe protection Bituminous tape with 7.50 Mtr. 2854.76
Paise Seventy Six only
black anti corrosive paint as per IS 10221, refilling the trench etc. of following sizes complete as required. Size :80 mm NB
Supplying & fixing single headed external yard hydrant valve with 1 no 63 mm dia instantaneous SS coupling and CI wheel, ISI marked, confirming to IS 5290 (Type A)
RS: Five Thousand Five Hundred Sixty Four and
238 with blank gunmetal /SS cap and chain as required 2.00 No. 5564.93
Paise Ninty Three only
Single headed stainless steel
Supplying and fixing 4 way Fire Brigade service inlet connection of CI body with gun metal instantanoeus male inlet coupling complete with chain & cap as required for RS: Twelve Thousand Four Hundred Thirty Five
suitable MS pipe (150 mm) connection conforming to IS 904 as required and Paise Twenty only
Supplying and fixing 2 way Fire Brigade service inlet connection of CI body with gun metal instantanoeus male inlet coupling complete with chain & cap as required for RS: Six Thousand Ninty Three and Paise Forty
suitable MS pipe (100 mm )connection conforming to IS 904 as required One only
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer.
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: Five Thousand Five Hundred Fifty Five and
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Paise Two only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 200 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: Three Thousand Six Hundred Six and Paise
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Ninty only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 150 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: Two Thousand Five Hundred Eighty One and
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Paise Fifty only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 100 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: One Thousand Nine Hundred Ten and Paise
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Thirty Nine only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 80 mm dia (6.3 mm thk )
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: One Thousand Six Hundred Forty and Paise
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Twenty Six only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 65 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: One Thousand Three Hundred Six and Paise
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Fifty Seven only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 50 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: One ThousandFifty Six and Paise Sixty Eight
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 40 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: Eight Hundred Seventy One and Paise Ninty
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 32 mm dia (6.3 mm thk )
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers,
nuts, bolts, gaskets etc and fixing the pipes on wall/ceiling with suitable clamps/support frame and painting with 2 or more coats of synthetic enamle paint of required shade RS: Seven Hundred Seventy Two and Paise
complete as required. The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the Ninteen only
satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. 25 mm dia (6.3 mm thk )
Providing, installing testing & commissioning of SS Y-strainers fabricated out of 1.6 mm thick SS grade 304, sheet with 3 mm dia holes with stainless steel flange RS: Ninteen Thousand Seven Hundred Seventy
Size : 200 mm Seven and Paise Fifty Nine only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers,
gaskets confirming to IS 13095 of following sizes as required:
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Thirteen Thousand Six Hundred Thirty Three
gaskets confirming to IS 13095 of following sizes as required: 200 mm dia and Paise Eleven only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Eight Thousand One Hundred Seventy and
gaskets confirming to IS 13095 of following sizes as required: 150mm dia Paise Twenty Seven only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Six Thousand One Hundred One and Paise
gaskets confirming to IS 13095 of following sizes as required: 100mm dia Twenty Five only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Four Thousand Five Hundred Thirty Six and
gaskets confirming to IS 13095 of following sizes as required: 80mm dia Paise Fifteen only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Three Thousand Nine Hundred Fifty Three and
gaskets confirming to IS 13095 of following sizes as required: 65mm dia Paise Ninty Three only
Supply and installation,testing and commisioning of Butterfly valves of PN 1.6 ratings with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, RS: Three Thousand Four Hundred Fifty Two and
gaskets confirming to IS 13095 of following sizes as required: 50 mm dia Paise Thirty only
244 Providing, installing testing & commissioning of NRV of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.
Providing, installing testing & commissioning of NRV of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 150 RS: Fifteen Thousand Eight Hundred Forty Five
mm dia and Paise Eight only
Providing, installing testing & commissioning of NRV of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 100mm RS: Nine Thousand Nine Hundred Forty Five and
dia Paise Sixty Eight only
Providing, installing testing & commissioning of NRV of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 80mm RS: Six Thousand Nine Hundred Twenty Six and
dia Paise Seventy Seven only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing, installing testing & commissioning of NRV of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 65 mm RS: Five Thousand Eight Hundred and Paise
dia Sixty Two only
RS: One Thousand Four Hundred and Paise
245 Providing & fixing of pressure switch in MS pipe line including connection etc. as required. 4.00 No. 1400.85
Eighty Five only
246 150 mm dial Bourdon type Pressure gauge with Syphon tubing, isoltaion valve & mounting accessories complete Range : 0 - 15 kg/sq.cm. 2.00 No. 1412.00 RS: One Thousand Four Hundred Twelve only
Providing, fixing, testing and commissioning of 15 mm dia quartzoid bulb type sprinklers of ratings 68 degree centigrade with required accessories:
247 96.00 No. 503.01 RS: Five Hundred Three and Paise One only
Pendent sprinkler
RS: Six Thousand Eight Hundred Sixty Nine and
248 SITC of test & drain assembly with all piping, sight glass, 25mm dia. test & drain valve etc complete 8.00 No. 6869.73
Paise Seventy Three only
RS: Two Thousand Five Hundred Twenty One and
249 Providing and fixing flow switches on MS pipe including connections etc. as required. 8.00 No. 2521.38
Paise Thirty Eight only
Getting provisional NOC and Final NOC and Renewal of NOC (During Defect Liability Period) for Fire Hydrant,Sprinkler system, Fire Extinguisher, Fire alarm system etc. from local fire authority or any
other relevant statutory authority at initial stage and required various other stages of construction work, including preparation of reports/drawings as per fire authority requirement. Rate also includes
renewal of Fire NOC during defectliability period as per requirement. Main agency has to give demonstration of all fire system to fire officer police / concern beneficiaries & GSPHCL. Agencyhas to submit
FDR of approved bank as per clause 2.0, section 3, of Rs 20000.00 Or Quoted rate which ever is higher to GSPHCL for minimum maturitperiod of Four yearsin favour of GSPHC, which will be released
after Successful Submitting of All Fire NOC at the completion of defect liability period.Renewal FireN.O.C. shall be submitted final S.D.proposal.Agency has charges like preparing and submission of all
the documents, Photographs, CD/DVD required to get the N.O.C. from concern fire department and also liaisoning work with concern departments. Main civil agency has to get the pre-NOC from fire &
RS: Sixteen Thousand Nine Hundred Fifty
250 emergency department well beforestarting civil & the fire hydrant work including sump & pumproom work. For that professional & experience fire agency has to prepare drawing of fire hydrant system, 1.00 JOB 16950.00
sprinkler system, fire alarm system, DGset etc. as per tender item and making floor layout of all fire pump panel, cable earthing etc in pump room. If any changes required in drawings of sump & pump only
room. Main agency has to inform in written before excavation of pump & sump room. Agency has to calculate the total head & discharge required as per NBC/local fire office requirement and as per
sitesituation and submit fire pump OEM specification curve foundation detail etc & get approval of cable, panel drawings & specification. After completion of fire hydraunt related work as per pre-NOC,
tender specification & drawing approved by fire department, agency has to do site visit with fire department & give the testing & demonstration to fire officer & get the final NOC before handing over of the
building. Agency has to give live testing & demonstration of all system to GSPHCL & police department jointly. For fire NOC fee separate item is taken in tender. Agency has to quote the rate as per latest
Gazettein respective tender item.
Supplying and installation of minimum 46 mm thick Fire rated door as per IS 3614-2021 standards made by galvanized steel conforming to 15 277 Fire door tested at
RS: Eleven Thousand Seven Hundred Forty and
251 CBR/NABL approved labs for maximum rating of 2 hrs tested. Test certificate submitted shall be with in the validity period of 15 years.The frame and shutter are finished 44.00 SMT 11740.27
Paise Twenty Seven only
with powder coating of 60 micron of approved colour with all necessary fittings (Fire door make approved by GSPHCL)
Providing and Laying of Fire Stop Mortar Seal( Fire Barrier) for Fire Penetration Sealing System in floor openings for vertical shafts & wall opening.The mortar seal shall RS: Fourteen Thousand Eighty Eight and Paise
have minimum 2 hours fire resistance . (M.S. Duct size 600mm x 600 mm) Ninty Eight only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Providing Supplying and Fixing S4 Channel System (S4 Channel + Profile Bracket + U Bolt Rubber mounted System) for multiple Pipes for External Vertical Fixed line with RS: Four Hundred Twenty One and Paise Fifty
wall distance 3" ncluding nuts, bolts, fastners etc complete as per detailed Specifications and as directed by Engineer in Charge. Eight only
Providing Supplying and Fixing Single Pipe Bracket System with U Bolt Rubber mounted for Pipe Supporting Clamping System for External Vertical Fixed line with wall RS: One Hundred Eighty Two and Paise Eighty
distance 3" including nuts, bolts, fastners etc complete as per detailed Specifications and as directed by Engineer in Charge. Three only
TOTAL CIVIL AMOUNT=
255a Providing and erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS 390.00 Point 481.00 RS: Four Hundred Eighty One only
wire for earth continuity in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected
on/in Brick Wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe and boxes shall be filled with cement mortar and
finishing the surface to match the wall / ceiling complete with approved make 5/6 Amp. ISI make modular type switch and accessories mounted in 20 G. G.I. company
fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling with necessary modular lamp holder / modular ceiling rose / HD
Connector (make & model approved by EIC and matching colur with switches accessories) (Deep Junction box 75mm depth if required) as directed for concealed wiring.
Light point. Cat.-III.
Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent mortar going into the box. Length of point wiring must not increase than 10 mtr. For
that necessary switch boards and their locations must be finalised before execution by agency otherwise payment will not be done for extra long point. (For future extention,
if required, agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost of blank plate shall be paid as per tender item) [This item
include cleaning (inside/outside) of all G.I. switch boards, electric point box, fan box, MCBDB & box cutting plaster finishing for modular plate without any gap] [conductor
resistance should be as per IS:8130/1984]
255b For Secondary Light Point, Cat.-III 190.00 Point 166.00 RS: One Hundred Sixty Six only
255c For Bell Point, Cat.-III 10.00 Point 481.00 RS: Four Hundred Eighty One only
255d For Fan Point.(with 6A Modular type switch and Two Module hum free 5/6 step EME step type Electronic fan regulator both having ISI Make ) Cat-III 115.00 Point 668.00 RS: Six Hundred Sixty Eight only
255e For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat. III 20.00 Point 505.00 RS: Five Hundred Five only
255f For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat. III 85.00 Point 255.00 RS: Two Hundred Fifty Five only
256 (MCB OPERATED-With out MCB) 25.00 Point 331.00 RS: Three Hundred Thirty One only
Providing and Erecting Point wiring with approved ISI marked 1.1KV grade 2 x 1.5 sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated
FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC pipe with adhesive solution erected in wall /
slab along with continuous G. I. fish wire to draw wires and laid in approved manner.zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to
match the wall / ceiling complete with Necessary assesories. Lenght of point wiring must be finallised before execution by agency other wise payment will not be done for
extra long point. For Concealed Wiring (a) For Light Point (Wire Must be having box packing) Cat-III (conductor resistence should be as per IS:8130/1984 [This item
include scleaning (inside/outside) of all GI switch boards,electric point box,fan box,MCBDB & box cutting plaster finishing for modular plate without any gap]
257 Providing and fixing Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x 2.5 sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC 20.00 Point 738.00 RS: Seven Hundred Thirty Eight only
insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with
adhesive solution erected in wall/slab along with continuous G. I. fish wire to draw wires and laid in approved manner zari for PVC pipe & boxes shall be filled with cement
mortar & finishing the surface to match the wall / ceiling complete with 16 Amp Modular type Swich and accessories mounted in 20 G. GI company fabricated metallic box
covered with appropriate front plate modules erected flushed with wall. (a) 16 Amp. Indicator switch & 1 No. 6/16 A universal socket white colour suitable for 3/5 pin top
duly both having ISI mark. (Necessary sheet / tape / polythene / sand must be erected or filled in all box To Prevent Mortor Going In To The Box) Cat.-III. (Conductor
resistance should be as per IS:8130/1984)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
258 Providing & Erecting Plug Point wiring with approved ISI marked 1.1 kv 2 x 4.0 sq.mm copper PVC insulated FRLS wire with 2.5 sq.mm (green) copper PVC insulated 5.00 Point 991.00 RS: Nine Hundred Ninty One only
FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 20/ 25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive
solution erected in wall/slab along with continuous G. I. fish wire to draw wires and laid in approved manner.zari for PVC pipe & boxes shall be filled with cement mortar &
finishing the surface to match the wall / ceiling complete with 1 No 25 Amp Modular type Single pole MCB Swich and 1 no 25A universal 3 pin socket suitable for 3 pin top
duty both having ISI mark .mounted in 20 G. GI company fabricated metallic box covered with appropriate front plate modules erected flushed with wall.Above accessories
will be erected combined or separately as per site requirement and instruction of EIC. (conductor resistence should be as per IS:8130/1984 Cat III (Gyser Point)
(Necessary sheet / tape / polythene / sand must be erected or filled in all box to Prevent Mortor Going In to The Box)
259 Providing & Erecting Plug Point wiring with approved ISI marked 1.1 kv grade 2 x 4.0 sq.mm copper PVC insulated FRLS wire with 2.5 sq.mm (green) copper PVC 15.00 Point 863.00 RS: Eight Hundred Sixty Three only
insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive
solution erected in wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner. zari for PVC pipe & boxes shall be filled with cement mortar
& finishing the surface to match the wall / ceiling complete with approved make 20 Amp. Modular type indicator switch and accessories mounted in 20 SWG GI company
fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling. (a) 20 Amp Indicator switch & 1 No. 20 A universal socket white
colour suitable for 3 pin top duly both having ISI mark (A.C POINT ONLY) CAT III (Necessary sheet / tape / polythene / sand must be erected or filled in all box to Prevent
Mortor Going In to The Box)
260a Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC 2500.00 Mtr. 24.00 RS: Twenty Four only
fittings & Junction boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish wire to draw mains with necessary fittings and junction boxes
for following dia. For 20 mm. dia.
260b For 25mm dia. 3000.00 Mtr. 33.00 RS: Thirty Three only
261a Providing & Erecting Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC 3000.00 Mtr. 62.00 RS: Sixty Two only
pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with
plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only)
(Conductor resistance should be as per IS:8130/1984 ) [a] 2 x 1.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded
conductor for earthing as per standard colour code. (with 20 mm dia. PVC pipe) [Wire must be having box packing]
261b For 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. (with 1600.00 Mtr. 82.00 RS: Eighty Two only
20/25 mm dia. PVC pipe) [Wire must be having box packing] (Conductor resistance should be as per IS:8130/1984 )
261c For 2 x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. (with 500.00 Mtr. 111.00 RS: One Hundred Eleven only
20/25 mm dia. PVC pipe) [Wire must be having box packing] (Conductor resistance should be as per IS:8130/1984 )
261d For 2 x 6.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. (with 25 800.00 Mtr. 146.00 RS: One Hundred Forty Six only
mm dia. PVC pipe) [Wire must be having box packing] (Conductor resistance should be as per IS:8130/1984 )
261e For 4 x 10.0 sq.mm. FRLS copper multi stranded conductor mains with 4.00 sq.mm. FRLS copper multi stranded conductor for earthing..As per standard colour code. 150.00 Mtr. 421.00 RS: Four Hundred Twenty One only
(with 25/32 mm dia. PVC pipe) (Conductor resistance should be as per IS:8130/1984 )
262 Providing & fixing 25 mm. dia Pvc insulated G.I corrugated flexible pipe with necessary socket, PVC bushes Saddle. 74.00 Mtr. 37.00 RS: Thirty Seven only
263a Providing & erecting Modular type accessories mounted on 20G. company Fabricated Galvanised Metal box covered with appropriate front plate modules erected flushed 5.00 Each 788.00 RS: Seven Hundred Eighty Eight only
with wall / ceiling with 1 Nos. TV Socket,1 Nos. of 16 Amp SP Switch & 3 Nos. of 6 Amp 3/5 pin plug. [For TV Switch board] Cat III
263b TV Co-axial Socket Outlet.Cat-III 5.00 Each 159.00 RS: One Hundred Fifty Nine only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
263c For Two pin / RJ-11Telephone Socket (For One Gang) Cat III 60.00 Each 159.00 RS: One Hundred Fifty Nine only
263d For Blank plate single Cat-III 200.00 Each 25.00 RS: Twenty Five only
263e For Modem Jack for Computer Open RJ-45 Cat III 65.00 Each 159.00 RS: One Hundred Fifty Nine only
263f For 16Amp. Universal socket. Cat.-III (For AC Points) 15.00 Each 198.00 RS: One Hundred Ninty Eight only
263g For 16/20/25 Amp. Modular Starter for Motor / A.C. Unit Complete Cat.-III 10.00 Each 493.00 RS: Four Hundred Ninty Three only
263h For Modular indicating call bell Cat.-III 10.00 Each 326.00 RS: Three Hundred Twenty Six only
263i For Modular Buzzer Cat.-III 10.00 Each 148.00 RS: One Hundred Forty Eight only
264 Providing & erecting Switch board for Computer or electric apparatus consisting of following items in single board erected on Metal board with 3 mm thick PC 65.00 Each 1122.00 RS: One Thousand One Hundred Twenty Two only
(Polycarbonet) / Acrylic sheet erected as directed. 2 no. 6/16 Amp. universal Socket, 2 nos. 16 Amp. indicator switch, 2 nos. 6 Amp. Switch & 2 nos. 6 Amp. 5 pin Plug.
For Computer power Supply board. Cat.-III.
265 Providing & erecting following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of 300.00 Mtr. 39.00 RS: Thirty Nine only
poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. for RG-6 [Polycab/ Finolex / RR Kabel Make]
266a Providing & Erecting 2.0 mtr long Earthing system by making minimum bore of 225 mm dia in soft soil. Suitable for doing pipe-in-pipe technology earthing.Earthing 6.00 Each 7025.00 RS: Seven Thousand Twenty Five only
electric rod must be made from Corrosion free Hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outerpipe:- 88 mm minimum O.D., ISI 'B ' Class ISI mark of Reputed Brand, Inner pipe:- 42 mm minimum O.D., Pipe B Class ISI mark reputed
Brand Terminal Size: 70mm X 100mm length, Terminal Should be made from inner pipe for that pipe must be pressed and gave rectangular shape so its work as a
terminal.The hot deep galvanising must be done after above process.Galvanised thickness must be minimum 75 micron any where. SS Nut bolt:- 2 no.with washer
suitable for 14mm dia. hole must be provided at terminal. total minimum Weight(approx.) of earth electrodewith inside conductive material minimum should be 26 kg.
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm/meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long time Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm depth and Cover should be heavy duty cast iron with required size of 300 mm
X 300 mm X 4 mm thick.
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to submit all detail & sample for approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured with earth tester. Agency has to bring the earth resistance to at least 02 ohms &
voltage between neutral & Earthing upto 02 volt. Agency has to maintain earthing & its value for one year. Earthing must be done in the presence of A.E. (GSPHCL)]
266b For above earthing additional charges for boring in hard rock soil (by breaker) & filling soft soil in earth pit (certificate for soil have to given by DEE / AE along with 6.00 Each 276.00 RS: Two Hundred Seventy Six only
267a Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS:694, IEC - 50.00 Mtr. 27.00 RS: Twenty Seven only
227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs,
nuts and bolts if required. For One wire 2.50 sq. mm
267b For One wire 6.00 sq. mm 100.00 Mtr. 56.00 RS: Fifty Six only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
267c For One wire 10.00 sq. mm 50.00 Mtr. 91.00 RS: Ninty One only
267d For one wire 16.00 sq. mm 450.00 Mtr. 141.00 RS: One Hundred Forty One only
267e For one wire 25.00 sq. mm 50.00 Mtr. 234.00 RS: Two Hundred Thirty Four only
267f For one wire 35.00 sq. mm 50.00 Mtr. 298.00 RS: Two Hundred Ninty Eight only
267g For One wire 70.00 sq. mm 100.00 Mtr. 663.00 RS: Six Hundred Sixty Three only
267h For One wire 95.00 sq. mm 50.00 Mtr. 910.00 RS: Nine Hundred Ten only
268 Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp with 350.00 KG 77.00 RS: Seventy Seven only
min 80 micron as per IS.Test certificate must be submitted by agency.
269 Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. 100.00 KG 787.00 RS: Seven Hundred Eighty Seven only
270 Supplying & erecting M.S./ G.I metal Box having 16 Gauge painted with red oxide be concealed in wall with necessary plastering & finishing covered with 3mm thick 1000.00 Sq inch 5.94 RS: Five and Paise Ninty Four only
Laminated sheet with grooving as directed of following depth. 3" Depth
271 Supplying and erecting 8 W LED lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge 45.00 Each 111.00 RS: One Hundred Eleven only
protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP holder
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
272 Supplying and Erecting LED indoor fitting of approximately 4feet long with LED of wattage 0.2W to 0.5W assemble on single MCPCB with housing use as a heat sink shall 200.00 Each 370.00 RS: Three Hundred Seventy only
be made from Aluminum extrusion having enough strength (sample must be approved by EIC) with polycarbonate diffuser with following specification: (A) Company
mark/name on the fitting.(B) Rated input voltage and frequency: 220V to 240 VAC ; 50Hz.(C) Rated input wattage: max. 24w(D) Rated input current : 0.2 Amp
(E) Power Factor : Min. 0.90(F) ATHD : Max. 15%(G) Rated Luminous flux: Min. 2420 lm
(H) CCT: 6500K(I) CRI: Min. 80Ra(J) Driver Efficiency: Min. 80%(K) LED life span: Min. 50000 Hrs @ L70(L) Over Voltage protection: Withstand up to 440V/AC for
Hrs.(M) Surge protection : Min. 2KV
(N) IP rating: IP 20(O) IK rating : IK 02(P) Short circuit , Open circuit & Reverse Polarity Protection must be provided(Q) Fixing clamp design & strength should be sufficient
to hold the fitting erected on wall or ceiling.(R) 3 core copper wire of appropriate size with earthing connector
(Note:-The manufacturer/ authorized Channel partner of the manufacturer has to submit 5 yrs free replacement Guarantee for complete Fixture) [Approval will be given
strictly subject to item specification]
273 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 24 w Cool/warm white Color LED Down lighter office Lighting Luminaire with external separate driver 115.00 Each 751.00 RS: Seven Hundred Fifty One only
having BIS certification with fully die cast aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish as a heat sink with Poly
Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux, Seoul, Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be
mounted onbacklit Metal core based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80 for individual LED Report mustbe submitted)
The fixture should have extra protection of driver like over/under voltage, THD<15%, P.F.>0.90, for 24 w fixture wide voltage range from 100 to 270 V, 50/60 HZ, 4 KV
surge protection.
Fixure must have Min. 2160 Lumens light output. Fixture Efficacy should be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on
POP/Grid False cieling. The Luminiare should be tested as per IP20 standards and following test reports should be submittedat the time of approval. Model Approved By
EIC as per Specification only (Note:- The manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement Guarantee for complete
274 SITC of Indoor Commercial recess/surface mounted (IP20) Max. 18 w Cool/warm white Color LED Down lighter office Lighting Luminaire with external separate driver 150.00 Each 584.00 RS: Five Hundred Eighty Four only
having BIS certification with fully die cast aluminium alloy housing without any PVC/Plastic part with corrosion resistant powder coated finish as a heat sink with Poly
Carbonet diffuser LED complete (only from Philips Lumileds, CREE, BridgLux, Seoul, Nichia & Osram CRI > 80, CCT 5600K (5400 to 5800K bin). The led's should be
mounted on Metal core based PCB for better heat conduction and long life of LED. (LM 79 for complete fixture, LM80 for individual LED Report mustbe submitted) The
fixture should have extra protection of driver like over/under voltage, THD<15%, P.F.>0.90, for 18 w fixture wide voltage range from 100 to 270 V, 50/60 HZ, 4 KV surge
Fixure must have Min. 1620 Lumens light output. Fixture Efficacy should be>=90 Lumens/watt. (L70 @ 30,000 Hrs) The Fixture should be able to easily mount on
POP/Grid False cieling. The Luminiare should be tested as per IP20 standards and following test reports should be submittedat the time of approval. Model Approved By
EIC as per Specification only (Note:- The manufacturer/authorized Channel partner/dealer of the manufacturer has to give a 5 yrs. free replcement Guarantee for complete
275 Providing and erecting max. 10 W LED battern having main housing aluminium extruded and front cover of polycarbonate. Electrically and photomatry parameters are as 30.00 Each 309.00 RS: Three Hundred Nine only
under:240 V, 50 Hz. System wattage.:10W+10%, PF>=0.95, system lumens min. 1000, CCT- 3000K to 6500K, CRI>=80, THD<=15%, Delivery efficiency>=85%, LM
certified LED, 30000 Hrs@ L70, Electronic CC driver, insulated copper wire, for internal wiring, IP20 Operating voltage:160 to 270 V, Surge-2 KV, length of this fitting
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) Tube Light with integral driver 8 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet
276 Providing and erecting PVC body surface mounting LED Bulk head type 9 watt Lighting Fitting with electronic driver having THD < 15%, CRI>80, P.F.0.95 And lumen 30.00 Each 780.00 RS: Seven Hundred Eighty only
output from luminaire 720 lm, input voltage range 160-270 V AC, 50 Hz cool white (3000 to 6500 k), inbuilt driver having efficiency >=80lm/w, -20 deg C to + 60 deg C
working temperature, AL frame with Beam Angle 120 deg.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
277 supplying & erecting 30 W LED POST TOP LATTERN fitting with high power white LEDs wattage of 1 ww and above assebled on single MCPCB's effiency more than 130 12.00 Each 4052.00 RS:Four Thousand Fifty Two only
lumens per watt and corrosion free high pressure diecast alluminium housing with smooth finish powder caoted and heat sink extruded alluminium with difuser and poly
carbonate optics/ lences with compny mark / name /engraved or embossed 120 to 300 volt, power factor more than 0.95, THD < 10%, CCT 5000K to 5700K , Uniformity
ratio > 0.45, Luminure efficency Min 110 lumens per watt. LED Driver efficency > 85%. Cree/osram/philips Lumileds/Nichia /Seoul/Bridge Lux (USA) make LED used for
luminare ( Each Fitting required LM 79 and LM-80 certificates) (B) Flood Light(IP-65)Surge-10KV.(E)Post Top Latern LED Fitting Comprises of 650 MM TOP diameter
degree beam angle with 3 Nos supporting ribs proposed for garden & Promenade. maximum 40 WATT, (Note:- The manufacturer/authorized Channel partner of the
manufacturer has to submit 5yrs free replcement Guarantee for complete Fixture)
278 Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 Star rated, Max. 30Watt Ceiling fan with Brush Less Direct Current (BLDC) permanent ferrite 120.00 Each 2603.00 RS: Two Thousand Six Hundred Three only
magnet Motor, class of insulation: B/E, Double ball bearings, Rust free 3 nos.Aluminium blades, 2 nos. canopies, shackle kit with earthing provision, copper winding,
Power factor not < 0.9, Service Value (CMM/W) minimum 7.5, Air delivery minimum 220 CMM, Minimum 345 RPM,230v (tolerance as per IS : 374-2019), THD < 10%,
compitible with electronic regulator unit for Five Speed Control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C
(Max.), suitable for 140 to 285 Voltage and rectifier circuit with surge, over current and overload protection , 50 Hz, Single phase AC Supply, earthing etc. Complete as
required.[ Make shall be approved by Engineer in Charge] (A) 1200 mm Sweep (48")
( Make - Havells Efficiencia Dx , Bajaj Energos 28 & Crompton make & model approved by EIC suject to above specification )
279 Supplying & Erecting Fan Hook Of 10 mm M.S Round bar bounded to the RCC bars up to 50 mm Length each side & piereced through 18 Gauge G.I Box having 125 mm 120.00 Each 125.00 RS: One Hundred Twenty Five only
dia depth of 75 mm complete erected concealed in ceiling with necessary modular plate / sheet
280 Supplying and erecting approved make oscillating type medium duty bracket fan with Aluminium Blades A.C. 23OV. 50cy/s, with thermal overload protection wall mounted 5.00 Each 3484.00 RS: Three Thousand Four Hundred Eighty Four
with height adjustment and rotary tilting device complete with guard, pull cord for speed and oscillation flexible Core plug top complete erected with lead wires as directed. only
For 450 mm sweep ( Make:- Bajaj,Usha, Crompton, Orient, Havells)
281 Supplying and erecting 19 / 20 mm. nominal bore "B" Class G.I Pipe /M.S. Pipe down rod erected duly painted for fan complete with necessary 24/0.2 flat 3 core flexible 100.00 Rn. Mtr. 107.00 RS: One Hundred Seven only
cable with earthing.The Down rod thickness,hole,locking arrangement,construction,power coating,colour shed should be same as original down rod brought with ceiling
fan.For that agency has to give original down road sample to fabricator and one sample down rod should be approved with EIC .After approval given by EIC agency can
use the down rod as per approved sample.If without approval down rod will be erect on site,agency has to replace them with own cost
282 Supplying and erecting approved make 200mm sweep low noise decorative exhaust fan having Aerodynamically designed and Blanced Blade, Blade finish Opaque,body 45.00 Each 1687.00 RS: One Thousand Six Hundred Eighty Seven
colour White , finish Glossy , Rated Speed 1350/1800 revolution per minute ,air delivery 500m³ / hr , noise level 50 dB , Power Consumption 35 W, ,Rated Voltage only
230 V , no. of blades 7 , guard 18 Louvers , square frame ABS body with inbuilt lowers and square frame.( Havells Make Ventilair LX or Bajaj, Usha, Crompton and
Equivalent Model Approved by EIC subject to Above Specification )
283 Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having 5.00 Each 3052.00 RS:Three Thousand Fifty Two only
following dia size and maximum speed:380 mm dia 1400 RPM
284 Providing and erecting Decorative Ding Dong call bell Stereo type 250 Volt complete erected on existing polished wooden block or in M.S. box with 3 mm thick white ISI 10.00 Each 170.00 RS: One Hundred Seventy only
mark laminated sheet. (Anchor (chime), Vision, Rider make)
285 SITC of Vertical Air Termination Solid aluminium with Base - 10 mm dia. and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse 3.00 Each 9323.00 RS: Nine Thousand Three Hundred Twenty
current withstand test: 100 kA of 10/350 µs waveform in an accredited. Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34 mm dia. 3000 Three only
mm long- Cold Galvanized as per EIC (OBO, JEF, CAPE, DHEN or equivalent make approved by EIC)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
286 SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the 300.00 Mtr 297.00 RS: Two Hundred Ninty Seven only
requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu.
conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessories should be tested as per IEC 62561-
1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a
sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230 (OBO, JEF, CAPE, DHEN or equivalent make approved
287 SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and 350.00 Mtr 153.00 RS: One Hundred Fifty Three only
used exclusively for lightning protection earthing system and ring equipotential bonding. [make and model approved by EIC strictly as per tender specification]
288 SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill 6.00 Per set 5933.00 RS: Five Thousand Nine Hundred Thirty Three
tested as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene only
Earth Pit Chamber with following dimensions: 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). [make and model approved by EIC strictly as per tender
289 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP-42 & above protection as per approval 6.00 Sq. Mtr. 16230.00 RS: Sixteen Thousand Two Hundred Thirty
from engineer incharge and made from 2 mm. thick CRC M.S. sheet for outer body & doors, 1.6 mm. thick CRC M.S. sheet for internal partitions with necessary supporting only
angles, flats including skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-In-Charge with erection
of supplied switchgears, busbars with suitable size of interconnecting PVC copper wire / Copper-Aluminium strips, rubber gromets, rib, control wires, backelite control fuses,
measuring instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with locking arrangement, rubber gasket
complete with Required Nos. heavy Duty Connector with Cadmium plated nut and bolt for Anti rusting. The panel shall be supplied with Seven Tank chemical process
which shall be carried out before applying painting, painted with powder coating. (The rates excludes the cost of switchgears, busbars, interconnecting mains & Copper /
Aluminium strip, fuse, meters etc. The dimension shall be measured excluding base beams) The standard companies switch gear shall be used and only manufacturers at
CPRI approved factory as per IEC 61439 and shall be certified by that company whose switch gears are used after fabrication for beneficial use. With 350 mm depth
Panel manufacturer have to give 5 years maintenance and service support if in case of breakdown or fault. Panel manufacturer have to submit electrical meter calibration
report. Agency should design the panel in such a way that there should not be any excess in panel area (sq.mtr) & length of bus-bar (mtr), if any excess occurs draw
attention to GSPHCL at the time of approval of G.A. drawing.
Loading and unloading of above item shall be done by hydra and skill work force under supervision of electrical engineer and guidelines given by manufacturer to avoid
damage to the item. Picture of it to be submitted in running bill / final bill.
Size of door and Ele. room / Pump room shall be checked by agency's engineer before giving order. If found any problem in size discuss with GSPHCL engineer for
rectification before giving order. [Including Necessary numbering / marking on PANEL done with red colour radium sticker as per site requirement and instructions given by
EIC on site. Font / number size given by EIC on site as per requirement] (All Panel as per IEC 61439 as per NBC Guideline) [Manufacturer must be of Gujarat state so
three stage inspection can be done]
290 Providing & erecting weather proof, dust & vermin proof, floor mounted front operated outdoor type double door cubical panel board necessary IP-54 and above protection 2.00 Sq. Mtr. 17777.00 RS: Seventeen Thousand Seven Hundred
as per require made from 2 mm. thick CRC M.S. sheet for outer body & doors, 1.5 mm. thick CRC M.S. sheet for internal partitions with necessary supporting angles, flats Seventy Seven only
including skirting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-In-Charge with erection of supplied
switchgears, busbars with suitable size of interconnecting PVC copper wire / Copper-Aluminium strips, rubber gromets, rib, control wires, backelite control fuses, measuring
instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with locking arrangement, rubber gasket complete with
Required Nos. heavy Duty Connector. heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete.The panel shall be supplied
with Seven Tank chemical process which shall be carried out before applying painting, painted with powder coating. (The rates excludes the cost of switchgears, busbars,
interconnecting mains & Copper / Aluminium strip, fuse, meters etc. The dimension shall be measured excluding base beams) Factory inspection for verification of
quality,workmanship and as per drawing & testing before dispatch the material as per tender condition. The standard companies switch gear shall be used and only
manufacturers at CPRI approved factory as per IEC 61439 and shall be certified by that company whose switch gears are used after fabrication for beneficial use. With
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Panel manufacturer have to give 5 years maintenance and service support if in case of breakdown or fault. Panel manufacturer have to submit electrical meter calibration
report. Agency should design the panel in such a way that there should not be any excess in panel area (sq.mtr) & length of bus bar (mtr), if any excess occurs draw
attention to GSPHCL at the time of approval of G.A. drawing. Loading and unloading of above item shall be done by hydra and skill work force under supervision of
electrical engineer and guidelines given by manufacturer to avoid damage to the item. Picture of it to be submitted in running bill / final bill.
Size of door and Ele. room / Pump room shall be checked by agency's engineer before giving order. If found any problem in size discuss with GSPHCL engineer for
rectification before giving order. [Including Necessary numbering / marking on PANEL done with red colour radium sticker as per site requirement and instructions given by
EIC on site. Font / number size given by EIC on site as per requirement]
291a Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 2.00 Rmt 1942.00 RS: One Thousand Nine Hundred Forty Two
Amp. / sq.mm (Rated current / cross section area) duly wraped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary only
bus bar supports / insulators, main cable socket to each bar, erected in existing cubical panel with necessary connections.For electrolyte copper busbars Suitable for
291b Suitable for 200 Amp. Capacity 2.00 Rmt 3171.00 RS: Three Thousand One Hundred Seventy One
291c Suitable for 300 Amp. Capacity 2.00 Rmt 4861.00 RS: Four Thousand Eight Hundred Sixty One
292a Supplying & erecting approved make Four Pole 415 V change over switch interior for panel mounting with operating mechanism A.C.23 duty confirming to IS. For 250Amp 1.00 Each 13221.00 RS: Thirteen Thousand Two Hundred Twenty
FP. Cat III One only
292b For 63A FP C/O Switch 1.00 Each 4738.00 RS: Four Thousand Seven Hundred Thirty Eight
293 Providing and Erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 K.A. at 415 V. having normal current rating 250 A. with 5.00 Each 20739.00 RS: Twenty Thousand Seven Hundred Thirty
Variable or fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections spreader tinned copper & complete erected in existing 16 Nine only
G.M.S. housing. ICS=100% of ICU only
294 Providing and Erecting approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V. having normal current rating 25 A to 10.00 Each 6112.00 RS: Six Thousand One Hundred Twelve
100A. with variable or Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections,spreader tinned copper & complete erected in only
existing 16 G.M.S. housing. ICS=100% of ICU only.
295 Providing and Erecting approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with 2.00 Each 7976.00 RS: Seven Thousand Nine Hundred Seventy Six
variable or Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections,spreader tinned copper & complete erected in existing 16 only
G.M.S. housing. ICS=100% of ICU only.
296 Providing and erecting following additional parts for panel mounting MCCBs (A)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 15.00 Each 865.00 RS: Eight Hundred Sixty Five only
25A to 250 A panel mounting. Company must be same as Switchgear company.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
297 Approved make Earth fault Relay suitable to mount with inter connection to moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 4.00 Each 5362.00 RS: Five Thousand Three Hundred Sixty Two
220V AC. with all internal connections & complete erected in existing M.S.housing. For 250A- 400A, CT Ration 1/400 only
298 Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 x 1/2 digits LED display, 0.5 class of accuracy 0 to 750 AC Volts range erected on 3.00 Each 1263.00 RS: One Thousand Two Hundred Sixty Three
existing panel board with all connection, wiring etc. with manufacturers calibration certificate. only
299 Supplying & erecting aproved make Panel mounting type Digital Ammeter having Three Digits LED Display,0.5 class of accuracy, External CT operated Calibrated for 0 to 3.00 Each 1543.00 RS: One Thousand Five Hundred Forty Three
1000 Amps suitable to operate on 500 Volt AC erected on existing panel board with all connection wiring etc.with manufacturers calibration certificate. only
300 Supplying, erecting, testing and commissioning of Ammeter / Voltmeter selector switch for 3 phase AC supply 500 V on existing panel board with necessary connections. 6.00 Each 314.00 RS: Three Hundred Fourteen only
301 Supplying and erecting approved make set of indicator lamps LED lamp, lense cover, bakelite holder complete erected with necessary connections. 9.00 Each 43.00 RS: Forty Three only
302 Providing, erecting, testing and commissioning of L.T. Current Transformer with bus bar primary 50/5 to 1000/5 ratio 15 VA burden having 0.5 Class Accuracy Duly 10.00 Each 272.00 RS: Two Hundred Seventy Two only
secured with insulating materials connected to the meter.
303 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in 42.00 Each 111.00 RS: One Hundred Eleven only
existing box. confirming to IS 8828/1996 with ISI Mark
304 Providing and erecting 240 volt MCB double pole switch for M&I(C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing with earthing terminal 5.00 Each 297.00 RS: Two Hundred Ninty Seven only
having following capacity. For 6-32 Amp Capacity.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
305 Providing and erecting 240 volt MCB double pole switch for M&I(C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing with earthing terminal 16.00 Each 327.00 RS: Three Hundred Twenty Seven only
having following capacity. For 40 Amp Capacity.
306 Providing and erecting 415 Volt MCB four pole motor & inductive load(c Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing metal box having 3.00 Each 662.00 RS: Six Hundred Sixty Two only
following capacity. For 40 Amp FP.
307 Providing and erecting 415 Volt MCB four pole motor & inductive load(c Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing metal box having 7.00 Each 730.00 RS: Seven Hundred Thirty only
following capacity. for 63 Amp FP.
308 Providing and erecting 240 volt MCB double pole switch for M&I(C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 with same company Metal box with 2.00 Each 502.00 RS: Five Hundred Two only
earthing terminal having following capacity. with necessary quarter Numbering with oil paint by Painter. for 40 Amp Capacity.
309 Providing and erecting 240 volt MCB Four pole switch for M&I(C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 with same company Metal box with 2.00 Each 905.00 RS: Nine Hundred Five only
earthing terminal having following capacity. with necessary quarter Numbering with oil paint by Painter. For 63 Amp Capacity.
310a Supplying & fixing box for housing RCCB + MCB combination made of 18 SWG sheet steel duly powder coated with gasket, dust & vermin proof bakelite shield two 5.00 Each 272.00 RS: Two Hundred Seventy Two only
earthing terminals for following type of RCCB, RCCB + MCB with necessary numbering / marking with oil Paint by painter. For 2 pole [Box must be of same company as
MCB, ELCB used]
310b For 4 pole [Box must be of same company as MCB, ELCB used] 5.00 Each 442.00 RS: Four Hundred Forty Two only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
311 Providing and Erecting approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable 10.00 Each 2213.00 RS: Two Thousand Two Hundred Thirteen
for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following only
Max. rating erected as directed for 40 Amps.DP
312 Providing and Erecting approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable 2.00 Each 1950.00 RS: One Thousand Nine Hundred Fifty only
for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed for 25 Amps.DP
313 Providing and Erecting approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable 2.00 Each 2611.00 RS: Two Thousand Six Hundred Eleven
for operation on 3 phase and neutral 415V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component for only
following Max. rating erected as directed. for 40Amps. FP
314 Providing and erecting metalic danger notice board as per language suggested by engineer inchrge for MEDIUM VOLTAGE installation to be erected as per IS-2551 3.00 Each 69.00 RS: Sixty Nine only
315 Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 1.00 Each 141527.00 RS: One lac Forty One Thousand Five Hundred
61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with Microprocessor based OC, Twenty Seven only
SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with Microprocessor based OC, SC, internal earth fault protection,Copper
tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each
capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCCB with Sc, OL, internal earth fault relay,Each stage having Stage
Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main
incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel. For 50KVAR
316 Supplying & erecting bank of all polypropylene condenser (APP type) with standard capacity of 2,3,5,7, 10,12.5 & 15 KVAR units of P.F. correction for operation on 3 phase 20.00 KVAR 690.00 RS: Six Hundred Ninty only
50 c/s, 400 /440V (+ / - 10%) with externally discharging resistance, earthing terminal & built on angle iron of channel iron frame work and provided with terminal cover box.
Complete erected on provided iron bracket or on floor duly tested by license.
317 Providing ad erecting approved make single phase Double Door metal clad D.B. as per relevant indian standards ammended upto date. 15.00 Each 5868.00 RS: Five Thousand Eight Hundred Sixty Eight
Supplying and fixing following way single phase MCB distrubution board of company fabricated with sheet box with powder coated inside and outside after apply seven tank only
chemical process of MS sheet cover complete with suitable integral single piece construction tinned copper busbar and link with all necessary interconnection and with
necessary size MS frame for mounting MCBDB. Manufacturer must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC 61439-1 & 3 having D type PU gasket. (2) Seven
tank Powder coating Certificate (3) Tinned Copper/Brass make neutral & Earthing link with isolation & Protecting Cover for 240 Volts on surface / recess complete with
loose wire box, terminal connectors for all incoming and outgoing circuits, with suitable size FRLS PVC insulated copper conductor up to terminal blocks and internal
connection, tinned coppper bus bar, 1 no. tinned copper neutral link, tinned copper earth bar, din bar, detachable gland plate, interconnections, powder painted including
Single phase incoming and horizontal single phase outgoing. For 16 Way MCBDB: Including 40 Amp. 30 mA double pole ELCB (ELCB confirming to IS:12640/1988
having sensitivity of 30 mA and breaking capacity of 10 KA), MCB 40 Amp. double pole switch (C curve confirms to IS:8828 having breaking capacity of 10 KA) and S.P.
MCB of rating 6 to 32 Amp. with NL suitable to operate on 240 Volt A.C. power. (6 Amp:- 4 Nos., 16 Amp:- 4 Nos. & 25 Amp: 4 Nos.) Cat.-III
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
(The DBs should be used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit level and finish the external edge with box
cutting plaster) (Same colour MCB(SP/DP) should be used as same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker as
per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement]
318 Providing ad erecting approved make Three phase Double Door Horizontal / Vertical type (as per site requirement and EIC instruction) outgoing per phase outgoing type 2.00 Each 3462.00 RS: Three Thousand Four Hundred Sixty Two
(PPI) metal clad D.B. as per relevant indian standards ammended upto date. only
Supplying and fixing following way Three phase MCB distrubution board with company wire links for internal connections having colour code and with suitable lugs and
company fabricated with sheet box with powder coated inside and outside after apply seven tank chemical process of MS sheet cover complete with suitable integral single
piece construction, tinned copper busbar and link with all necessary interconnection and with necessary size MS frame (if required) for mounting MCBDB. Manufacturer
must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC 61439-1 & 3 having D type PU gasket. (2) Seven tank Powder coating Certificate (3) Tinned Copper/Brass make
neutral & Earthing link with isolation & Protecting Cover for 440 Volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing
circuits, with suitable size FRLS PVC insulated copper conductor up to terminal blocks and internal connection, tinned coppper bus bar, 4 nos. tinned copper neutral link,
nos. tinned copper earth bar, din bar-4 nos., detachable gland plate, interconnections, powder painted including earthing etc.
Three phase incoming and single phase outgoing. For Three phase 6 Way Double Door PPI MCBDB
(The DBs should be used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit level and finish the external edge with box
cutting plaster) (Same colour MCB(SP/DP) should be used as same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker as
per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement]
319 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 1.00 Each 1664.00 RS: One Thousand Six Hundred Sixty Four
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase only
incoming and horizontal single phase outgoing sheet steel double door (IP-43)
For Single phase incoming and horizontal single phase outgoing For Double door-16 Way
(The DBs should be used of same company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit level and finish the external edge with box
cutting plaster) (Same colour MCB(SP/DP) should be used as same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium sticker as
per site requirement and instructions given by EIC on site. Font / number size given by EIC on site as per requirement]
320 Supply, Installation, Testing & Commissioning of Three Phase, 440 V Surge Suppressor protection Device (SPD) & 40 Amp TPN MCB (or As per SPD OEM guide line for 2.00 Each 6319.00 RS: Six Thousand Three Hundred Ninteen
the protection of SPD which is erected such a way that it can be operated easily) SPD must be capable to protect all electrical and electronics equipments if SPD blast or only
fuse then the panel builder must have replace it soon during defect liability period.The Detail Specification of SPD are As per Attached sheet with Annexture -A(E).
(Hakel,ikra,OBBO make) (With Three year Gaurantee/warranty)
321 Supplying and erecting Servo Controlled Voltage Stabilizer (SCVS) as per following requirement: (1) Input Voltage Range - Three Phase 340 To 480 Volt AC. (2) Out put 1.00 Each 262200.00 RS: Two lac Sixty Two Thousand Two Hundred
Volatge - Three Phase 415 Volt AC (Line - Line) with Voltage Regulation of +/- 1%. (3) Frequency range - 47 Hz To 63 Hz. (4) Efficiency - More or equal to 98%. (5) Type only
of Stabilizer - Suitable for Balance & Unbalance Load and Voltage including SPD (6) Controlled Type - Digital Micro Controller Based Disply. (7) Rate Of Correction - Upto
100 Volt / Sec (Line - Line) (8) Servo Motor Drive - AC Syncronous Stepper Motor - As per KVA Capacityy, Out put volatge and Voltage regulation requirement. (9) Nil
Wave form Distortion and Effect of Load POwer. (10) Responce Time - 10 milli second. (11) Protection requirements - Input low Cut off protection / Input High Cut Off
Protection / Output Low Cut Off protection / IOutput High (12) Fault Annuciation Panel LED shows Input present, Input high Input low, Output Normal, Output High,
Outpur low, Overload. (13) Output On time delay - 10 seconds (14) Ambient Tempeature capacity - 0 - 45 RH upto 90 %. (15) Enclosure Type - IP 20 (16) Type of Cooling -
Air ,Output:Bypass switch with changeover switch and Provied SPD & 4 year free replacement guarantee on Stamp paper.
Loading and unloading of above item shall be done by hydra and skill work force under supervision of electrical engineer and guidelines given by manufacturer to avoid
damage to the item. Picture of it to be submitted in running bill / final bill.Size of door and Ele. room / Pump room shall be checked by agency's engineer before giving
order. If found any problem in size discuss with GSPHCL engineer for rectification before giving order. (100 KVA) (Fuji Electric, Servomax Limited, Krykard, protekG
322a Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free & flame proof confirming BS with necessary 50.00 Mtr. 275.00 RS: Two Hundred Seventy Five only
end caps Internal and external bend, flat bends, coupler, tee etc. All necessary accessories and measuring of following sizes.For 75 mm x 50 mm trunking (MK /
Legrand/OBO Make Only)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
322b For 100 mm x 50 mm trunking (MK / Legrand/OBO Make Only) 50.00 Mtr. 424.00 RS: Four Hundred Twenty Four only
323a Supplying and erecting approved make GRP Perforated type Cable Tray with required GRP Straight Coupler Plates , Corner etc. Material – Corrosion Resistant Polyester 100.00 Rmt. 526.00 RS: Five Hundred Twenty Six only
Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length :
3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low
Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard
ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod
Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 –
For Width - 300mm, Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr. ( Sumip,coromandak,Eircon,satyam-composite Make or equivalent
make app by engineer in charge subject to above specification)
323b For Width - 150 mm, Pultruded “C” Channel with 30mm Sides 3 mm Thickness, Loading 15 Kg./Mtr. 100.00 Rmt. 230.00 RS: Two Hundred Thirty only
324a Supplying and erecting approved make FRP/GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - 50.00 Rmt. 493.00 RS: Four Hundred Ninty Three only
Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side
Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm,
Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low
Flammability - Oxygen Index – Minimum 30% as per ASTM D
Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength –
2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as
per Standard ASTM D 695- Barcol Hardness – 50 –
(A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span
(Sumip,coromandak,Eircon,satyam-composite Make or equivalent make app by engineer in charge subject to above specification)
324b For Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span 50.00 Rmt. 636.00 RS: Six Hundred Thirty Six only
325 Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double 50.00 Rmt. 306.00 RS: Three Hundred Six only
bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c
spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected
on existing support as per Specification and as per instruction of engineer in charge..for 300 X 50 X 2.0 mm Thick
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
326 Providing, erecting, fabricating the M.S. structure as per requirement of site as per structure design Including proper size approved by EIC of M.S. angles, flats, bars, 100.00 kg 74.92 RS: Seventy Four and Paise Ninty Two only
square pipe, channels, sections (Tata,Zindal,Asian,Jsi Make) complete with cutting, welding, grinding and finishing duly painted with Asian/Nerolac make premium quality
oil paint and true care red oxide metal primer,asian paint make with erection on site as per direction of engineer in charge with necessary grouting cementing, plastering
and finishing complete. All hole opening of square pipe end must be closed with M.S plate welding. Payment will be done on KG as per Actual weight.
327 Supplying & erecting 12 mm thick backelite sheet of approved make and grade on 25 x 25 x 3 mm red oxide painted angle iron frame suitable for fixing ICDP SWITCH 4.00 Sq. Mtr. 2289.00 RS: Two Thousand Two Hundred Eighty Nine
and energy meter (contractor shall make approved drawing of Bakelite sheet To arrange required No. of Energy meter & ICDP switch -busbar etc. as per Actual space only
available in electrical room at site)
328 SITC of specified make X color for Cat.-6 Data and Y color for Cat.-6 voice cable to be done in prelaid PVC pipe / raceway, but without the cost of raceway or pipe (the wire 3250.00 Mtr. 47.00 RS: Forty Seven only
is to be drawn from MFD/ JB to outlet point) (a) CAT - 6 (For Computer Cabling and For Voice Cabeling) (Molex, Avaya, D-Link, Legrand make Only)
329 SITC of Layer 2 Switch, Shall have 24-port 1000 BASE-T (RJ45) PoE+ with additional 2-port 1GBASE-X (SFP+), 190W PoE Budget with single power supply unit, shall 4.00 Each 31680.00 RS: Thirty One Thousand Six Hundred Eighty
have minimum 52Gbps non-blocking fabric across 28 ports, Switch must have advance feature like VLAN Tagging, Voice VLAN, LAGs, LACP, IGMP Snooping, Multicast only
VLAN Registration, ACLs, LLDP, SNMP, QOS. Switch’s Operating System should be tested under Common Safety Criteria Certification & as per attached details
specification. (Make:- Netgear/Cisco Enterprise/HP Enterprise )
330 Supply, Installation, testing and commissioning of 24 port Cat 6 19" Toolless Patch Panel ( fully loaded) enable all possible combinations of the various types of cable 4.00 Each 4357.00 RS: Four Thousand Three Hundred Fifty Seven
mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19” chassis only
and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19” uprights of the enclosure. Include rear cable support with plastic cable guides
to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19” rails without use of cage-nuts. These may be used to secure the
connections of wifi access points, IP cameras, servers, or other critical devices. Front Removal IO's option for maintenance and trouble shooting with 6 Different Colours
Labels for Labelling & Identification of Individual Ports. & as per attached details specification. (CAT 6 )
331 SITC of company fabricated Patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall 65.00 Each 155.00 RS: One Hundred Fifty Five only
have RJ-45 jacks. For 1 Mtr.[Make and model approved by EIC as per specification]
332 SITC of company fabricated Patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall 6.00 Each 199.00 RS: One Hundred Ninty Nine only
have RJ-45 jacks. For 2 Mtr. [Make and model approved by EIC as per specification]
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
333 Supply and installation of 9U steel rack for installing 4 nos. Ethernate switches/Hubs. The Rack should be fully enclosed steel housing fabricated with 14 SWG sheet and 3.00 Each 11441.00 RS: Eleven Thousand Four Hundred Forty One
powder coated with glass doors and having wire management systems. The rate includes the Exhaust Fan, 2 nos. 4 socket and 1 switch power strip and all the wiring in the only
rack. (Rittal, Valrack, APC, Legrand Make and model approved by EIC as per specification)
334 Supply and installation of 15 U Equipment steel rack Wall mounting for installing , lan switch, Patch panel, etc, rack should be fully enclosed steel housing fabricating with 1.00 Each 19069.00 RS: Ninteen Thousand Sixty Nine only
14 SWG Sheet and powder coated with glass doors and having wire nos. wire management system . the rate includes the exhaust fan 2 nos, 6 Sockets and 1 switch power
strip and all the wiring in the rack.& as per attached details specification.600mmX600mm ( Make:- APW president/ APC/ Valrack/Rittal/Netrack)
335a Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & 50.00 Mtr 463.00 RS: Four Hundred Sixty Three only
sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs.
With necessary connections. For Conductor Size 0.5 mm armoured Fifty Pairs.[make and model approved by EIC strictly as per tender specification]
335b For Conductor Size 0.5 mm armoured Twenty Pairs.[make and model approved by EIC strictly as per tender specification] 50.00 Mtr 198.00 RS: One Hundred Ninty Eight only
336a Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips For Suitable for 50 pair (Krone type) 1.00 Each 1730.00 RS: One Thousand Seven Hundred Thirty only
336b For Suitable for 20 pair 2.00 Each 1355.00 RS: One Thousand Three Hundred Fifty Five only
337a Supply, Installation testing and commissioning of 16 Gauge M.S. Powder coated floor raceway Access outlet/ service junction box with 16 Gauge M.S. Powder coated 10.00 Each 749.00 RS: Seven Hundred Forty Nine only
Cover plate with duct entry 25 mm / 38 mm size having epoxy powder coated trap lead with corrosion & rust free with adjustable levelling screw of following size. for
mm x 300 mm x 50 mm depth. (M.k, legrand, OBBO)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
337b For 150 mm x 150 mm x 50 mm depth (M.k, legrand, OBBO) 10.00 Each 672.00 RS: Six Hundred Seventy Two only
338 Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from 100.00 Mtr 1329.00 RS: One Thousand Three Hundred Twenty Nine
seepage of concrete of screed water with all accessories,Junction Box,Joints as required and demanded by engineer-incharge and laying/erecting as per OEM guidelines only
and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III for 300 mm x 38 mm x 1.6 mm with Three
Compartments (M.k, legrand, OBBO make only)
339 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per 10.00 Each 6917.00 RS: Six Thousand Nine Hundred Seventeen only
IS 2629/2633/4759, suitable suspend local wind speed with integral Junction box with Hot Deep Galvanised door having 2 nos. 180° operated hinges & 2 nos. Ln key
locking with silicon rubber gasket. Consist of terminal plate of min 6mm Hylam sheet, standard profile 35 mm X 7.5 mm Din-Rail & MCB, Brass stud type terminal and
arrangement for cable termination to be erected on RCC foundation as per details given by manufacturer and EIC considering site requirement. Foundation Details: (1)
Grade of RCC 1:2:4, (2) Grade of steel rainforcement of RCC FE 415, (3) Clear cover to rainforcement 50mm, (4) Concrete vibrated, (5) use suttering / farma, (6) Hot deep
galvanized average 70 Micron, (7) Detail drawing will be given by corporation
For 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness with 200 mm X 200 mm X 12 mm base plate, 4-M16 Bolts and 600 mm long hot deep galvanized J-
Bolt, nuts, washers with 800 mm under ground and 200 mm above ground level and Foundation in 1:2:4 proportion as per details given by manufacturer and EIC
considering site requirement. Approx Pole weight 46 kg.(Make:- Bajaj, Valmont, Transrail, Ambica Only) (Test certificate to be submitted)
340a Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 2.00 Each 890.00 RS: Eight Hundred Ninty only
5way(3P+N+E), DIN rail for mounting mob & hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth bolt of following size of box. For 300mm x 200mm x 100mm
340b For 250mm x 200mm x 100mm [deep] 2.00 Each 510.00 RS: Five Hundred Ten only
340c For 140mm x 140mm x 100mm [deep] 2.00 Each 295.00 RS: Two Hundred Ninty Five only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
341 Supplying and making Coil type earthing, coil made from 8 SWG galvanised iron wire with 50 mm OD and 50 turns (length of turns approx. 200 mm) and having additional 10.00 Each 369.00 RS: Three Hundred Sixty Nine only
continuous streight length of 3.00 mtr at open end and should be connected to earthing bolt and burried in 1.5 mtr deep specially prepared earth pit complete with salt and
charcoal/coke as required for coil type earthing.(Approx weight of coil 1.0 to 1.1 Kgs)
342 Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S. sheet having following size complete with fixing arrangement for terminal 10.00 Each 702.00 RS: Seven Hundred Two only
board, with necessary hole for wire entry and exit from the box. The box shall be provided with cover and hinges on one side and bolting at other end The box shall be fixed
by clamps fabricated from 25mm x 6mm flat.The box shall be painted with one coat of red oxide and two coats of paint having following box size 330 mm x 260 mm x
mm (depth). Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with 15 Amp. kitkat pattern porcelain fuse unit with suitable brass studs with
nuts, washers and clamps of size 25 mm x 3 mm suitable for pole painted with one coat of red lead paint.
343 Providing and Fixing of wall and terrace bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside diameter and length suitable for building face for fixing the 8.00 Each 487.00 RS: Four Hundred Eighty Seven only
brackets and having spread of Upto 0.70 mtr. length with suitable degree angle as per site situation suggested by EIC. vertical plane and suitable welded stiffner reducer
and nipple with check nut complete painted with one coat of red oxide and two coats of alluminium paint with . complete with 150*150*2mm thick G.I plate with 4no heavy
duty galvanized jasti khila of required size or Single arm bracket (pipe in pipe type) suitable for terrace as per design given by EIC Considering parfait, height ,width and
total height of building and type of led fitting . For single arm bracket. (Jindal / Asian / Tata / Surya Prakash make Only) (Fabricators:- Impression / Fab / Bajaj / Impression
equipment Only) (Test certificate to be submitted)
344a Providing & erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside diameter complete with suitable G.I. Sleeve tubing of 2 mm. thick and required size 8.00 Each 487.00 RS: Four Hundred Eighty Seven only
and length suitable for 76.5 / 80 mm. required size of pole top or pipe in pipe surface for terrace as per instruction of EIC or wall bracket as per instruction of EIC having
nuts and bolts for fixing the brackets and having spread of Upto 0.50 mtr. length with suitable rise as per site condition and suitable welded stiffner reducer and nipple with
check nut complete painted with one coat of yellow zinc and two coats of alluminium paint for Single arm bracket suitable for pole or terrace as per design given by EIC.
For single arm bracket. (Jindal / Asian / Tata / Surya Prakash make Only) (Fabricators:- Bajaj, Valmont, Transrail, Ambica, RR Ispat Only) (Test certificate to be submitted)
344b For Double arm bracket. (Jindal / Asian / Tata / Surya Prakash make Only) (Fabricators:- Bajaj, Valmont, Transrail, Ambica, RR Ispat Only) (Test certificate to be 2.00 Each 616.00 RS: Six Hundred Sixteen only
345 SITC of Outdoor aesthetically designed LED Street Light Luminaire with total consumption of Max. 45 W with single piece die cast aluminium housing, high power LED 10.00 Each 3512.00 RS: Three Thousand Five Hundred Twelve only
shall be mounted on high quality metal core PCB with extremely precison designed heat sink complete with IP66 protection Class with polycarbonate / thoughened glass
cover the fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED module min. 130 lumen/watt with toughen
Glass L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light distribution. The watt capacity of Each LED must be >=4W in street light fitting. The
Fixture Should be able to be Pole Mounted and also bracket mounted, provided with high quality driver for protection against high and low Voltage cut Off, opertional for
high amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias Oprating
range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total lumens not less then 4950, CCT > 5000K, CRI > 65, beam angle 120 deg, surge immunity level at
least 4 KV integral and 10 KV non integral (Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit 5yrs free replcement Guarantee for
complete Fixture)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
346 SITC of Outdoor aesthetically designed LED Street Light Luminaire with total consumption of Max. 90W with single piece die cast aluminium housing, high power LED shall 6.00 Each 6117.00 RS: Six Thousand One Hundred Seventeen only
be mounted on high quality metal core PCB with extremely precison designed heat sink complete with IP66 protection Class with polycarbonate / thoughened glass cover
the fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED module min. 130 lumen/watt with toughen Glass
L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light distribution. The watt capacity of Each LED must be >=4W in street light fitting. The
Fixture Should be able to be Pole Mounted and also bracket mounted, provided with high quality driver for protection against high and low Voltage cut Off, opertional for
high amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias Oprating
range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total lumens not less then 9900, CCT > 5000K, CRI > 65, beam angle 120 deg, surge immunity level at
least 4 KV integral and 10 KV non integral (Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit 5yrs free replcement Guarantee for
complete Fixture)
347 SITC of Outdoor aesthetically designed LED Street Light Luminaire with total consumption of Max. 120 W with single piece die cast aluminium housing, high power LED 3.00 Each 6701.00 RS: Six Thousand Seven Hundred One only
shall be mounted on high quality metal core PCB with extremely precison designed heat sink, complete with IP66 protection Class, with polycarbonate / toughened glass
cover. The fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED minimum 130 lumen/watt with toughen
glass, L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light distribution. The Fixture Should be able to be Pole Mounted and also bracket
mounted, provided with high quality driver for protection against high and low Voltage cut Off, opertional for high amibient and high humid envirnoments, THD of driver
should be less than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias Oprating range Voltage 160 to 270 V, system efficiency >= 110 lm/w,
and total lumens not less then 13200, CCT > 5000K, CRI > 65, beam angle 120 deg, surge immunity level at least 4 KV Integral & 10 KV Non Integral. The Separate
Potted driver should have over current, over voltage protection, short circuit protection so that the fixture recovers once the fault is removed. In addition to the above
product should be operational in the temperature range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The manufacturer/authorized Channel partner of
the manufacturer has to submit 5 yrs free replcement Guarantee for complete Fixture)
348 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption of maximum 120 W with single piece die cast aluminium housing, LED's 3.00 Each 7395.00 RS: Seven Thousand Three Hundred Ninty Five
mounted on high quality metal core based PCB with extremely precison designed heat sink, complete with IP66 protection Class, with polycarbonate / Toughened glass only
cover. The fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED minimum 110 lumen/watt with L70 at
50,000 hrs, provided with high quality polycarbonate Seperate lenses for better light distribution.The watt capacity of Each LED must be >=4W in street light fitting. The
Fixture Should be able to be Pole Mounted and also bracket mounted, provided with high quality potted driver for protection against, high and low Voltage cut Off,
opertional for high amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the following technical
criterias. Operating range Voltage 160 to 270 V, system efficiency > 110 lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge immunity
level at least 10 KV non integral... Flood Light lumens shall be more than 13200. (Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
5yrs free replcement Guarantee for complete Fixture)
349 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption of maximum 90 W with single piece die cast aluminium housing, LED's mounted 3.00 Each 6228.00 RS: Six Thousand Two Hundred Twenty Eight only
on high quality metal core based PCB with extremely precison designed heat sink, complete with IP66 protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED minimum 110 lumen/watt with L70 at 50,000 hrs,
provided with high quality polycarbonate Seperate lenses for better light distribution. The watt capacity of Each LED must be >=4W in street light fitting. The Fixture
Should be able to be Pole Mounted and also bracket mounted, provided with high quality potted driver for protection against, high and low Voltage cut Off, opertional for
high amibient and high humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias.
Operating range Voltage 160 to 270 V, system efficiency > 110 lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge immunity level at
least 10 KV non integral... Flood Light lumens shall be more than 9900. (Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit 5yrs free
replcement Guarantee for complete Fixture)
350 Providing , erecting , testing and commissioning Insu Intelligent Streetlight Controller specially design for energy saving in conventional streetlight system ( Cat. No. SLC- 1.00 Each 20255.00 RS: Twenty Thousand Two Hundred Fifty Five only
03-1Ph-7.5KVA-20Amp/Cat NoSLC-03-1 ph-15 KVA 20 amp per phase) having technial specification ,1 phase 2 wire, 230 V AC/ph +/- 25% R Y B N 2 Wire supply
System.50 Hz (+ / - 10 %), 2 W (Stand By) to 4 W (at street light operation)consuption, Advance 8 bit micro controller, switching on longitude and latitude base, accaracy of
+- 1 minute per month. with inbuilt battery, with battery life of more than 8 years, with speicial device which hold the parameter for more then 10 years without any power
and password protected. 16 character and two line LCD display with backlight, 4 keys user friendly keyboard system, 7500 VA feeder pillar capacity, 63/100 amps isolator
,3 Outpus with termination 40/63 Amps 2/3 pole contactor , 3X16 Amps with F R cable provision to by pass by way of relay operation through auto/manual switch, 2 to
centigrade and humidity 90 % non condensing Outdoor type installation on pole with clamps.(Provided with clamps and nut bolt) or wall or floor, three locking system flush
type internal panel lock, external pad lock and internal U clamp locking systems for against theft of panel. having 17/25 Kg weight ,16/18 guage MS weather proof with
industrial exterior powder coated with 7 tank process RAL
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
351a Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable for 1100 volt to be laid 90 cms. Under ground or to be laid on wall with 50.00 Mtr. 724.00 RS: Seven Hundred Twenty Four only
suitable G.I. heavy guage 1.0mm thick cable clamp or in existing DWC pipe underground or road crossing or floor. For 3*1/2 core 150 Sq. mm (70 Sq. mm * 1/2 core)
351b For 3*1/2 core 95 Sq. mm (50 Sq. mm * 1/2 core) 100.00 Mtr. 486.00 RS: Four Hundred Eighty Six only
351c For 3*1/2 core 70 Sq. mm (35 Sq. mm * 1/2 core) 100.00 Mtr. 375.00 RS: Three Hundred Seventy Five only
351d For 3*1/2 core 50 Sq. mm (25 Sq. mm * 1/2 core) 100.00 Mtr. 282.00 RS: Two Hundred Eighty Two only
351e For 4 core x 25 Sq. mm 45.00 Mtr. 189.00 RS: One Hundred Eighty Nine only
352 Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Copper cable for 1100 volt to be laid 90 cms. Under ground or to be laid on wall with suitable G.I. heavy 500.00 Mtr. 361.00 RS: Three Hundred Sixty One only
guage 1.6mm thick cable clamp or in existing DWC pipe underground or road crossing or floor. For 4 core x 4 sq.mm.
353 Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked unarmoured Copper cable for 1100 volt to be laid 90 cms. Under ground or to be laid on wall with suitable G.I. 100.00 Mtr 568.00 RS: Five Hundred Sixty Eight only
heavy guage 1.0mm thick cable clamp or in existing DWC pipe underground or road crossing or floor. For 4 core x 10 sq.mm.
354a Providing & fixing Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to 24.00 Each 15.00 RS: Fifteen only
switchgear terminals with brass/cadmium plated nut bolts in an approved manner. For 16/25 Sq.mm.
354b For 35/50 Sq.mm 32.00 Each 20.00 RS: Twenty only
354c For 70 sq.mm 24.00 Each 25.00 RS: Twenty Five only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
354d For 95 Sq mm 24.00 Each 40.00 RS: Forty only
354e For 150 Sq.mm 30.00 Each 61.00 RS: Sixty One only
355 Providing & fixing Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to 149.00 Each 8.00 RS: Eight only
switchgear terminals with brass/cadmium plated nut bolts in an approved manner. For 1.5/2.5 to 6 Sq.mm
356a Providing & fixing double compressed heavy duty flange type brass cable gland with rubber ring for P V C insulated armoured cable complete with outgoing tails, insulating 25.00 Each 43.00 RS: Forty Three only
tape etc. For following size cables.For 2 to 4 core x 4.0 Sq. mm (Sigma, MCI, Comet Make Only)
356b For 4 core x 25.0 Sq. mm (Sigma, MCI, Comet Make Only) 10.00 Each 66.00 RS: Sixty Six only
356c For 3*1/2 core x 35.0/50.0 Sq. mm (Sigma, MCI, Comet Make Only) 10.00 Each 75.00 RS: Seventy Five only
356d For 3*1/2 core x 70.0 Sq. mm (Sigma, MCI, Comet Make Only) 15.00 Each 102.00 RS: One Hundred Two only
356e For 3*1/2 core x 95.0 Sq. mm (Sigma, MCI, Comet Make Only) 12.00 Each 130.00 RS: One Hundred Thirty only
356f For 3*1/2 core x 150.0 Sq. mm (Sigma, MCI, Comet Make Only) 12.00 Each 189.00 RS: One Hundred Eighty Nine only
356g For 2 to 4 core x 10.0 Sq. mm (Sigma, MCI, Comet Make Only) 10.00 Each 48.00 RS: Forty Eight only
357 Providing & fixing PVC cable gland with rubber ring for P V C insulated unarmoured cable complete with outgoing tails, insulating tape etc. For following size cables. For 2 8.00 Each 25.00 RS: Twenty Five only
to 4 core x 6.0 to 10Sq. Mm.
358 Supplying following size of Light duty “A” Class G.I. Pipe & erecting as directed by Engineer-in-charge. For 25 mm dia. 20.00 Mtr. 171.00 RS: One Hundred Seventy One only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
359a Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper wires of following size to be erected as directed. For 3 core 2.5 sq.mm. 50.00 Mtr. 77.00 RS: Seventy Seven only
PVC insulated round copper wire ISI mark.
359b For 3 core 1.5 sq.mm. PVC insulated round copper wire ISI mark. 150.00 Mtr. 46.00 RS: Forty Six only
360a Providing & laying HDPE Double walled corrugated pipes (DWC) (conforming to IS: 16205 (part 24) 2018)) with minimum load required of 450N capacity with anti rodent 400.00 Mtr. 117.00 RS: One Hundred Seventeen only
and ultra violet material properties with necessary connecting accessories of same material at required depth to be laid 90 cms. under ground for laying of cable below
ground / road surface for enclosing cable and back filling the same to make ground as per original. For Outer dia. 50 mm and Inner dia. 38 mm. (Test Certificate to be
360b For Outer dia. 90 mm and Inner dia. 75 mm. (Test Certificate to be Submitted) 100.00 Mtr. 150.00 RS: One Hundred Fifty only
360c For Outer dia. 120 mm and Inner dia. 100 mm. (Test Certificate to be Submitted) 100.00 Mtr. 191.00 RS: One Hundred Ninty One only
361 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cms. below ground across the road crossing or on floor with necessary material in an approved manner and 20.00 Mtr. 261.00 RS: Two Hundred Sixty One only
making the ground as per original. For 150 mm Dia
362 Providing and erecting open well type horizontal submersible mono block pump set with cast iron body having following specification For 3 phase open well horizontal 2.00 Each 15552.00 RS: Fifteen Thousand Five Hundred Fifty Two only
mono block pump set suitable for ...270..LPM discharge at required head as per plumbing length and vertical & Horizontal head.Agency has to submit the details
calculation of head to GSPHCL and get approval of make and model of pump having tender specification with TDS & GA drawing. Suitable for 50/65 mm dia delivery pipe
with 10 mtr. necessary Size 3 Core Flat copper flexible cable. (Body: Cast iron / Winding : Copper / stator : Copper / rotor : Copper / shaft : SS 304 material test certificate
from manufacture shall be submitted).The model of the pump with respect to head and discharge will be approved by EIC. Pump should have following specifications:(1)
Minimum 10 mtr. Cu. flat cable of suitable size must be provided with pump.(2) Pump shall be installed as per manufacturer foundation/erection drawing or as per IS
specification. (Body full C.I., stator winding- copper, rotor- copper, shaft- SS 304, motor-Energy efficiency)
363 Supplying and erecting approved make 3 HP DOL type motor control cubical panel made from 16 G. CRCA sheet duly epoxy powder painted inside and outside with 1.00 Each 47062.00 RS: Forty Seven Thousand Sixty Two only
hinged doors and locking arrangement Floor Mounting On 300 mm Height with MS Stand Angle & CC Foundation. Size 35 mm (H) x 35 mm (W) x 05 mm (D). The detail
specification & quantity of material used are as under.
Panel must be with minilec relay for auotmatic change over for pump 1 & 2 logically without using manually change over switch (Minimum Panel Size: 1.10 meter (H) x
1.10 meter (W) x 0.25 meter (D).
INCOMMER SECTION: (1) MCCB-30 KA-FP (Ics = 100% Icu), Rating: 63 Amp., Make: L&T, Qty: 01 No. (2) Digital Ammeter (SR-65), Rating: 0-60 Amp., Make: Meco,
Qty: 01 No. (3) Ammeter Selector Switch, Rating: 6 Amp., Rotary, Make: Salzer, Qty: 01 No. (4) Digital Voltmeter (SR-65), Rating: 0-500 V, Make: Meco, Qty: 01 No. (5)
Volt Selector Switch, Rating: 6 Amp., Rotary, Make: Salzer, Qty: 01 No. (6) C.T.- Current Transformer, Rating: 60/5 Amp., Make: Virat, Qty: 03 Nos. (7) Indicating Lamps
(R,Y,B), Rating: 22.5 mm LED, Make: Airon, Qty:03 Nos. (8) SP MCB , Rating: 20 Amp., Make: L&T , Qty: 03 Nos. (9) Control Wiring, Rating: 1.0 Sq.mm, Make: Any ISI,
Qty: Lot (10) Copper Busbar, Rating: 63A/100 Amp., Qty: Lot (11) Numeric logical relay, Qty: 1 No.
Outgoing Feeder (3 HP DOL Feeder): Qty: 02 Nos. (1) MCB-FP-10 KA, Rating: 20 Amp., Make: L&T, Qty: 02 Nos. (2) Power Contactor (415 V) Main, Rating: 12 Amp.,
Make: L&T, Qty: 02 Nos. (3) Over Load Relay, Rating: 6-10 Amp., Make: L&T, Qty: 02 Nos. (4) Digital Ameter (SR-65), Rating: 0-20 Amp., Make: Meco, Qty: 02 Nos., (5)
Digital Voltmeter (SR-65), Rating: 0-500 V, Make: Meco, Qty: 02 Nos. (6) Indicating Lamps (Start,Run,Trip), Rating: 22.5 mm LED, Make: Airon, Qty: 04 Nos. (7) Push
Button (Start,Stop), Rating: 22.5 mm, Make: Airon, Qty: 02 Nos. (8) SPP, Rating: 415 V, Make: Space, Qty: 02 Nos. (9) Terminal, Rating: As per Amp., Make: Airon, Qty:
04 Nos. (10) Control Wiring, Rating: 1.0 Sq.mm., Make: Any ISI, Qty: Lot (11) Power Wiring, Rating: As Per Amp., Make: Any ISI, Qty: Lot
Outgoing Feeder (6 Amp. - 01 No.) For Capacitor (1) MCB-FP-10 KA, Rating: 6 Amp., Make: L&T, Qty: 01 No. (2) Capacitor- MPP Type, Rating: 2 KVAr, Make: Concap,
Qty: 01 No., (3) Power wiring, Rating: As Per Amp., Make: Any ISI, Qty:Lot
Outgoing Feeder (32 Amp. - 01 No.) For Lighting (1) MCB-FP-10 KA, Rating: 32 Amp., Make: L&T, Qty: 01 No. (2) Power wiring, Rating: As Per Amp. (3) Earthing Strip:
x 3; G.I. Strip, Qty: 01 No. (4) MCB-DP-10KA , Rating: 20A, Make: L&T, Qty.:01 Nos.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
364 Lowering of existing submercible motor pump set complete with required No. and size of pipes by means of proper chain pulley block and pipe wrenches. Job includes 2.00 Each 848.00 RS: Eight Hundred Forty Eight only
stacking of pipes cronologically after the checking of threads. For open well horizontal submercible pump set for sump well. For 1.00 HP to 5.00 HP
365 Providing & erecting ISI make medium duty (B class) galvanized MS pipe with coupling, bend, union, reducer, tee, MS flange etc. with plumbing charges.For 50 mm dia 20.00 Mtr. 260.00 RS: Two Hundred Sixty only
366 Supplying and erecting C.I. Swing check type non-return (reflux) valve ISI marked with packing, flange, nuts and bolts etc.suitable for following pipe size. For 50 mm dia. 3.00 Each 1010.00 RS: One Thousand Ten only
(SANT , KIRLOSKAR , LEADER , ZOLOTO)
367 Supplying Water tight M.S.Box of size 20 x 15 x 15 cms. to erect suitable kitkat fuse / MCB to be . erected on polished wooden board inside the box with hinged/sliding 1.00 Each 232.00 RS: Two Hundred Thirty Two only
door with rubber rings and erected on pole with suitable pole clamp, all duly painted with one coat of red oxide and two coats of paints.
368 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible copper cable approved make of following Size. For 3 Core x 2.5 Sq. mm. 20.00 Mtr. 103.00 RS: One Hundred Three only
369 Providing Water proof straight Joint in PVC insulated flat flexible copper cable by using insulating material, water proofing material, & making the joint complete. Up to 2.00 Each 188.00 RS: One Hundred Eighty Eight only
370 SITC of Inverter based approved make Cassette type split air-conditioning unit consisting of condensing unit with fan motor, hermetically sealed scroll/rotary compressor 2.00 Each 79932.00 RS: Seventy Nine Thousand Nine Hundred Thirty
with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by Eco friendly Green gas charging & Internal copper wiring Two only
& Remote control ( 3 star and above of current year) with necessary core cutting. for 2 ton capacity ( Make:- OGENERAL, MITSUBISHI,BLUESTAR, DAIKIN ) ( Model
approved by EIC)
371 SITC of Air condationer copper tubing with minimum 19mm thick class O nitrile rubber insulation for entire piping system. Exposed refrigerant piping should be additionally 20.00 Rmt 956.00 RS: Nine Hundred Fifty Six only
insulated with factory laminatede 200GSM glass cloth for UV and mechnical protection and manufacturer recommended adhesive ( Solvent-free) sealant appiled at all
joints Uv- Protection layer. additional layer of UV paint over GC for all exposed to atmosphere piping for weather protection of pipes & insulation and prevention of rain
water ingress. For Single phase/ Three Phase Split A.C. Machine/ Cassate A.C Machine insulated pair of soft, copper tubing including power and control cable, 20/25/32
mm Dia. Rigid (ISI marked) UPVC drain pipe. Duly Insulated with 6 mm elastomeric nitrite rubber up for Split AC machine up to 2 TR capacity
372 Executing comprehensive (All-in-All) service & maintenance with spare parts as per terms & condition of tender for 2 Dry Service & 2 water or Chemical service with AC 2.00 Each 8784.00 RS: Eight Thousand Seven Hundred Eighty Four
agency for defect liability period and copy of this contract will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness only
certificate from system agency and submit to G.S.P.H.C.L. Agency has to Compulsory submit FDR of approved bank as per clause 2.0, section 3 of FDR of Rs.17,568.00 +
GST or quoted rate (as per tender premium % above) whichever is higher to G.S.P.H.C.L. for minimum maturity period of five years in favour of G.S.P.H.C.L., Which will
be released after successful completion of A.M.C. & at the completion of defect liability period. In any case without submitting FDR final bill submission will not be done.AC
agency has to maintain written record of service & maintenance during defect liability daily period duly sign by police dept. and submitted regularly to G.S.P.H.C.L. Agency
has to give minimum three services and demonstration per year and testing and training of entire Air Conditioning system. during defect liability period and obtain
necessary certificate from police department and submitted to G.S.P.H.C.L. Agency has to do maintenance as per terms & condition alternative in tender. (Agency will
have to submit stability and performance certificate regarding AC system from authorized dealer/OEM of AC at the time of final SD release). For delay in rectifing the fault
penalty will be deducted from agency S.D. For 2.0 Ton Inverter based approved make Cassette type split air-conditioning.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
373 SITC of UPVC drain pipe of 10 Kg/cm2 rating with 9 mm thick nitrile rubber insulation. & necessary support & concealed work in wall for 25mm dia. UPVC drain piping 50.00 Rmt 87.00 RS: Eighty Seven only
(with 8 mm Nitrile rubber Class O Insulation) from each HAT/DSAC/OA/WM Split/Cassette units to drain point/header
374 Carry out RCC Core cutting- up to 100 mm dia./200mm thick Wall/beam/slab with providing PVC pipe of 3 mm thick inside and necessary finishing on both ends of wall . 10.00 Job 1188.00 RS: One Thousand One Hundred Eighty Eight only
375 Carry out RCC Core cutting- up to 100 mm dia./300mm thick Wall/beam/slab with providing PVC pipe of 3 mm thick inside and necessary finishing on both ends of wall . 10.00 Job 1534.00 RS: One Thousand Five Hundred Thirty Four only
376 Supplying, Erecting, Testing & Commissioning the 10 passenger( Basement+Parking+ 4 upper Floor) lift having following main features[1] GEAR LESS LIFT DRIVE 1.00 Each 1341271.00 RS: Thirteen lac Forty One Thousand Two Hundred
comprising of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used.( MACHINE Seventy One only
ROOM LESS/ MACHINE ROOM)
[2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full
collective selective operation shall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless
steel of sheet of grade 304 (Jindal, Tata, Sail, AM/NS(Essar) make only) duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car
flooring shall be Good quality higher strength aliminium chequred plate/ granite/ pvc flooring( as per site requirement and instructed by EIC. Car doors shall be of stainless
steel grade 304 (Jindal, Tata, Sail, AM/NS(Essar) make only), hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 (Jindal, Tata,
Sail, AM/NS(Essar) make only) finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor
switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for min. 2 hours and shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 (Jindal,
Tata, Sail, AM/NS (Essar) make only) with key holes and infrared curtains with Unlocking facility from outside.
[5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided. Also emergency Light & Fan should start immediately without any
time delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple criss / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity with Manual Rescue Operation (Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan and lights with automatic sleep timer shall be provided.
[12] Voice annunciater with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor calibration as per actual site parameters and submission of calibration certificate required, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure
works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
[17] Permanent wiring with necessary safety devices like RCCB / ELCB in all circuit, Over voltage / Under voltage protection and THD eliminator in circuit in lift machine
room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Only 3 phase, 440 V Power supply of shall
be made available by department in lift machine room. Necessary Earthing as per Lift Act / Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by lift agency without any extra
cost.(granite/marble fixing around all landing door openings are not in lift agency’s scope.)
[19]Intercom Suitable For Hook Up To EPBAX
[20] Agency Has To Provide All Working Drawing & Document & Liaison Service For Obtaining All Necessary Permission From Lift Inspector & Other Authorities including
erection permission and lift license and its related fees.
[21] Lift Agency has to provide Acrylic transparent License / Display A4 size holder in Lift car.
[22] As Per Statutory Requirement Of Govt. Of Gujarat Lift & Escalator Act 2000, Lift Agency Has To Provide.
1. Car Top Safety Barried
2. Push & Talk Communication system
3. Fireman's Switch Operation at Ground Floor.
4. Carrying out third party Lift inspection during / after Lift erection and provide report by Third party authorized by concern Licensing authority.
5. Agency has to provide Third party insurance upto completion of free maintenance period / Defect liability period and submit the documents for the same to G.S.P.H.C.L.
[23]Including Providing Comprehensive Maintenance Service (Including Spare Parts)During Defect Liablity Period Complete As Required & As Specified.All Civil Work Carried For Lift Installation Should
Be Done By Contractor .Contractor Shall Arrange All ApprovalForm all Concern Department For Lift.
[24] Car panel operating buttons with floor position indicator / buttons must be of Auto Glow type clearly visible when view from inside cabin.
[25] For Physically Handicapped person Full Length Handrails of hairline finish steel grade of SS 304 should be provided at appropriate height on the rear and side wall panels in Lift Car.
[26] All Civil Work Carried For Lift Installation Should Be Done By Contractor. Contractor Shall Arrange All Approval Form all Concern Department For Lift
[27] Required Capacity of Three Phase Voltage Stabilizer as per Lift OEM Requirement Having Input voltage Range - 340 to 480 Volt AC and Output Voltage Range 415 Volt AC +-1% ( line - Line ).
Voltage stabilizer must be installed at Machine Room.
[28]In this tender agency has to maintain all lift including services and spare parts during defect liability period as per item inluded in tender. One year free service & Maintenance shall be provided by
OEM. Detail Specification of lIft as per Annexure( Including Duplex system )
[29]lift outer door has male female provision for 2 hr fire rated door
[30] Factory inspection for verification of quality,workmanship and as per drawing & testing before dispatch the material as per tender condition.
[31] Inverter/UPS/Battery for ARD Unit to be covered with lock and Key Powder Coated Box and fix it to be suitable height on Wall.
[32] GSPHCL will be provided conceptual drawing of Machine Room equipments & Wiring.As per drawing Lift manufacturer should be consider Machine Room Size,Orientation and equipments size and provide drawing of Cable Route and
Equipment and get approval from GSPHCL Engineer prior to start the work.
[33] Lift Panels shall be supplied with Seven Tank chemical process which shall be carried out before applying painting, painted with powder coating & IP 55 protection and all lift Cables must be erected in 16 SWG Raceway made from
[34] Advanced Control sysstem dual 32 bit embedded microprocessor with CANBUS serial communication mode operation on site programming facility , anti nuisance, pre-opening, BMS/ RMS system supporting hardware & Software. False
call Canceling/ Anti Nuisance,
[35] As per gujarat lift and escalator act 2001 and central electricity authority regulations 2010, RCCB for lift cabin and lift machine must be installed in control panel by lift manufacturer.
Details specification of lift as per Annexure-A. For 10 passengers (Basement+Parking+ 4 upper Floor ) with Rated Speed of 1.5 m/sec with micro processor /PLC control and ACVVVF.drive Cat-III
377 Executing comprehensive (All-in-All) service & manitenance (Including replacement of battery For ARD) with spare parts as per terms & condition of tender lift 1.00 Job 147540.00 RS: One lac Forty Seven Thousand Five Hundred
manufacturer for defect liability period.For that main agency has to give All-in-All comprehensive maintenance contract to lift manufacturer and copy of this contract will be Forty only
submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness certificate from lift manufacturer and submit to G.S.P.H.C.L.
Agency has to submit FDR of approved bank as per clause 2.0, section 3, of Rs. 1,47,540.00+GST or quoted amount whichever is higher to G.S.P.H.C.L. for minimum
maturity period of Four years in favour of GSPHC, Which will be released after successful completion of AMC & at the End of defect liability period. lift OEM has to
mantain written record of service & maintenance during defect liability daily period duly sigh by police dept. and submited regularly to GSPHCL. Lift agency has to do
maintenance as per terms & condition alternate in tender. Also Lift OEM agency should have proper dress code or identity card during any work ralated to lift due to safety
reasons and authentication to get sign of Police Man. For delay in rectifing the fault, penalty will be deduced from agency S.D.Whenever agency applied to final S.D. to be
released to department.All Lift licenses are within Validity period of use.In case it is expired then agency has to renew lift licence.No drawings,documents & liasoning work.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
378 Supplying, Installation, Testing & commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as 1.00 Each 186556.00 RS: One lac Eighty Six Thousand Five Hundred
required: (a) Horizontal type, Single stage, centrifugal, End Suction Long Coupled Pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal Fifty Six only
conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply
with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable Cement Concrete Foundation duly plastered with anti
vibration pads. (e) cost include foot valve of suitable size CI body heavy duty. (f) Discharge :- minimum 1620 LPM. Note: The head of the pump shall be selected in a
manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point. Agency has to calculate the total head required for getting minimum 3.5kgf/cm2
pressure at the farthest & highest point of building of wet riser fire system. For that agency has to calculate total pump head by considering vertical head ( Total Building
height+ Sump depth+3.5kgf/cm2 pressure & Total equivalent vertical head due to frication losses of total length of pipe + bend number, Elbow number, Tee, Valve etc.)
Agency must have to select pump model having required head & discharge( asper fire department rules) at duty point. No Extra payment shall be done for head variation
due to site situation & fire rules. The panel shall be design according to motor H.P
379 Supplying, installation, testing and commissioning of Diesel engine driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all 1.00 Each 456202.00 RS: Four lac Fifty Six Thousand Two Hundred Two
respects, as required: [Diesel driven pump] only
(a) Horizontal type, Singlestage, centrifugal, End suction Long Coupled pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to
(b) Suitable HP 2900 RPM water cooled with radiator diesel conforming to relavant IS standard complete with auto starting mechanism 12/24 Volts electric starting
equipment, diesel tank, exhaust pipe extended upto 10 M outside pump house duly insulated with 50 mm thick glass wool with 1.00 mm thick aluminium sheet cladding,
residential silencer, instrument and protection as per standard specification, stop solenoid for auto stop in the event of fault with auto indications painted with post office red
color etc. as required.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
(e) Cost include providing, erecting req. size copper XLPE Armound cable with GI cable tray, support etc. as per EIC instruction (app. cable lenth 15 mtr.)
(f) Cable from pump to panel will be laid in cable tray or fixed on G.I./M.S. strip / channel as per instructions given by EIC as per site requirement.
(g)Cost include foot valve of Suitable size CI body heavy duty (SANT,Kirloskar, Kartar, Zoloto make)
(h)Discharge:- minimum 1620 LPM. Note: The head of the pump shall be selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
[The all require Technical specification & Test certificate shall be submitted to Local fire Authority for approval]
(Factory inspection will have to carried out by agency with G.S.P.H.C.L. engineer)
380 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, 1.00 Each 73821.00 RS: Seventy Three Thousand Eight Hundred
complete in all respects, as required: (Jockey Pump). Twenty One only
(a) Horizontal type, Singlestage, centrifugal, End suction Long Coupled pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to
(b) Suitable HP Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz AC supply with IP 55 class of protection for enclosure,
horizontal foot mounted type with Class-'F' insulation,conforming to IS :
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
(e) Required size 3 core flat cable from pump to panel for connection should be provided with pump.
(f) Cable from pump to panel will be laid in cable tray or fixed on G.I./M.S. strip / channel as per instructions given by EIC as per site requirement.
(g) Cost include foot valve of suitable size CI body heavy duty.(SANT,Kirloskar, Kartar, Zoloto make)
(h) Discharge:- minimum 180 LPM. Note: The head of the pump shall be selected in a manner so as to give a
minimum 3.5kgf/cm2 pressure at the highest/farthest point
(Factory inspection will have to carried out by agency with G.S.P.H.C.L. engineer)
381 Fabrication, supply, installation and commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2 mm thick CRCA sheet, 1.00 Each 217623.00 RS: Two lac Seventeen Thousand Six Hundred
compartmentalised with hinged locable doors, dust and vermin proof, power coated of approved shade after 7 tank treatment process, cable alley, inter connection with Twenty Three only
suitable size copeer conductor cable/solid copper strip having switchgear and accessories, mounting and internal wiring, earth terminals, numbering etc. complete in all
respect suitable for main fire pump, pressurisation pump and diesel pump set complete as per specification with following incoming and outgoings suitable for operation on
415 V, 3 phase 50 Hz AC supply with enclosure protection class IP 42 as required.
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Upto 250A, 50 KA 4 Pole MCCB Ics=100% Icu rating.
Digital voletmeter 0-500 V with selector switch
Digital ammeter 0-250 A with selector switch and CT's etc.
LED type RYB phase indicating lamp, ON, OFF, TRIP indicationg lamps.
Set of copper busbar 300 A.
[Note:- All outgoing feeder for pumps should have digital ammeter with selector switch and LED type ON, OFF and TRIP indicating lamps.)
MAIN FIRE PUMP:
125 A 50kA TPN MCCB Ics=100% Icu with fully automatic star/delta starter suitable for 60 HP pump with overload protection current sensing type single phase preventor
complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
63 A 50kA TPN MCCB Ics=100% Icu with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with
all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL:
1) Automatic/Manual selector switch and 3 attempt starting device, timers and relay as required, push buttons, start/stop in manual mode.
2) Indicating lamp for high/low lub oil pressure, high water temperature and engine ON indication.
3) Battery charger suitable for 12/24 V DC with boost and trickle selector switch 0-30 V DC Volt meter and 0-20 A DC Ammeter.
4) All standard relays and accessories for autoamtic operation of diesel engine.
SYSTEM CONTROLLER:
Design, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, Pressurisation (Jockey) Pump, Diesel pump and
terrace pump in sequence as per specification consisting of relays, timers, sensors, annunciation window for fault indication complete as per specification.
382 Providing and fixing of Pressure switch with Needle valve ( Indfos,Honeywell,System Sensor make and Model Instruct by EIC (Only) 3.00 Each 1310.00 RS: One Thousand Three Hundred Ten only
383 Providing and fixing of Air Release Valve including Ball Valve 25 mm dia. (Approved ISI make & model approved by EIC strictly as per specification) 2.00 Each 1601.00 RS: One Thousand Six Hundred One only
384 Supply, Installation, Testing and Commissioning of Pump On-Off switch (with all mounting accessories , complete with Junction Box for mooting on Surface, Cable lugs at 4.00 Each 890.00 RS: Eight Hundred Ninty only
Ends, cable compression glands, cable tags and Ferruling.)for remote operation from each floor of the building. (Approved by EIC) (Test certificate must be submitted)
385 Providing and erecting PVC insulated PVC Sheathed flat flexible copper cable ISI marked approved make of size with all require accessories For 3 Core x 6 Sq. mm. 50.00 Mtr. 171.00 RS: One Hundred Seventy One only
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
386 Providing and erecting PVC insulated PVC Sheathed flat flexible copper cable ISI marked approved make of size with all require accessories For 3 Core x 16 Sq. mm. 50.00 Mtr. 484.00 RS: Four Hundred Eighty Four only
387 Executing comprehensive (All-in-All) service & maintenance with spare parts as per terms & condition of tender for Fire terrace pump with fire hydrant agency for defect 1.00 Per Tower 58658.00 RS: Fifty Eight Thousand Six Hundred Fifty Eight
liability period and copy of this contract will be submitted before final bill. Agency has to quote rate accordingly. Agency has to also provide the fitness certificate from only
system agency and submit to G.S.P.H.C.L. Agency has to compulsory submit FDR of Approved bank as per clause 2.0 section 3 Rs.58,658.00+GST or quoted Amount
whichever is higher to G.S.P.H.C.L,for minimum maturity period of Five years in favour of G.S.P.H.C.L Which will be released after successful completion of A.M.C. & at
the completion of defect liability period. Fire System agency has to maintain written record of service & maintenance during defect liability period duly sign by police dept.
and submit regularly to G.S.P.H.C.L. Agency has to give minimum three services and demonstration per year and testing and training ofentire fire hydrant, sprinkler, fire
alarm, fire extinguishers, etc.during defect liability period and obtain necessary certificate from police department and submit to G.S.P.H.C.L. Agency has to do
maintenance as per terms & condition alternative in tender.Refilling hydraulic pressure of co2 and ABC type fire extinguishers if required to set N.O.C. from fire
department.Agency has to give One live demonstration of fire Mock drill for fire fighting with minimum 01 no. CO2 and 01 no. ABC type fire extinguisher at the time of
handing over this system to the Police department and another at the time of releasing final Security deposit. The necessary certificate / photographs for that must be
388 Supply ,Installation , testing & Commissioning of heavy duty meduim voltage cable as per specficification & IS 7098 part I , 4C X 1.5 SQ.,MM ARMOURED CABLE (CU.) 200.00 Mtr. 107.00 RS: One Hundred Seven only
FRLS,RED colour with approved make , with require support , cable tie, cable tagging , hardare are etc to complete the work.(As per BIS standard)
389 Supplying and erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked copper wires of following size to be erected as directed.For 1.50 Sq.mm 2 3000.00 Mtr. 31.00 RS: Thirty One only
core round PVC sheathed. having insulation colour RED and BLACK for Fire Alarm System.
390 SITC of Microprocessor based Net-workable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by 1.00 Each 126006.30 RS: One lac Twenty Six Thousand Six and Paise
LPCB/Vds. The Fire Alarm Control Panel shall have inbuilt one loop and expandable capacity upto 2 loops. The Panel must have large graphic display. The Panel must Thirty only
also have the capability to take Addressable Intelligent Wired Devices. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base
Sounder Beacons. The Panel shall have 240 V AC power supply along with automatic Battery Charger. Non-Networkable Approved by LPCB (Make: BOSCH/ Siemens/
Hochiki make only)
391 SITC of Photo Electric Smoke Sensor, Features includes Low profile - only 2" high including base, variable sensitivity from 0.7 to 4% obs/Ft Simple and reliable device 110.00 Each 2,415.38 RS: Two Thousand Four Hundred Fifteen and
addressing, Automatic compensation for sensor contamination, Built-in Fire test feature, Two built-in power/alarm LEDs, Programmable non-polling LEDs, Non-directional Paise Thirty Eight only
smoke chamber, Vandal resistant security locking feature. (Make: BOSCH/ Siemens/ Hochiki make only) (compliant with EN54 & approved by LPCB & Vds)
392 SITC of Fixed Temperature/Rate of Rise sensor, Low profile-only 2.00" high, including base, simple and reliable device addressing method, Rate of rise temperature 5.00 Each 2,288.25 RS: Two Thousand Two Hundred Eighty Eight and
threshold = 15° F/Min, Adjustable threshold temperature = 135° - 190°, Approved by LPCB & VDS. (Make: BOSCH/ Siemens/ Hochiki make only) (compliant with EN54 & Paise Twenty Five only
approved by LPCB & VDS)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
393 Supply, Installation, Testing and Commissioning of addressable manual call point having IS or BS (EN-54) (Vds Approved) or NFPA 72 (UL/ULC/FM approved) with Latest 12.00 Each 826.00 RS: Eight Hundred Twenty Six only
Amendment complete as required. (Make: BOSCH/ Siemens/ Hochiki make only) (compliant with EN54 & approved by LPCB & Vds)
394 Supply, Installation, Testing and Commissioning of Intelligent loop powered wall sounder which provide arange of tones and volumes with a maximum output of up to 12.00 Each 826.00 RS: Eight Hundred Twenty Six only
102dB(A) (+_2dB(A)) with low current consumption, 51 user selectable tones (all tones EN54-3 compatible). (Make: BOSCH/ Siemens/ Hochiki make only) (compliant with
EN54 & approved by LPCB & Vds)
395 Supplying, installation, testing & commissioning of response indicator - Dual LED (Metal square plate type) (Make: BOSCH/ Siemens/ Hochiki make only) 12.00 Each 150.00 RS: One Hundred Fifty only
396 Providing and fixing of ABC Type Store Pressure Fire Extinguisher Having capacity 6 kg Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored 15.00 Each 1991.00 RS: One Thousand Nine Hundred Ninty One only
Pressure Type, UGTS Pressure Gauge, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters,
Average Discharge is 92%, applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & CO2 Mig welded,
EPDM(Ethylene Propylene Diene Monomer) Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester
Powder coating (UV Resistant),Brass forged CE Marked valves with NRV & Auto Safety Release with safety Pin is of SS material, Made up from 1.6mm thick sheet,
Extinguishers confirmed to IS 15683:2018 and ISI marked. Referance Weight:-Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, 1. Necessary certificate & and guarantee
must be attached, 2. OEM has to provide wall mounting heavy duty bracket/clamp, screw, hardware for installation. 3.Following printed marking Manufacturing Date and
Expiry Date must be mention on Extinguisher 4. Refilling period must be of 3 Years. Following Printed marking on equipment must be required:- Model No, Capacity,
Gross Weight, Content, Fire Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with necessary numbering / marking with oil paint by painter as instructions given by
G.S.P.H.C.L engineer] (Make: KANEX, MINIMAX, CEASEFIRE)
397 Providing and fixing of CO2 type High Pressure Portable 4.5 kg Fire Extinguisher, filled with Co2 Gas as per IS 15222, Control discharge mechanism fitted with 1 Meter 15.00 Each 6526.00 RS: Six Thousand Five Hundred Twenty Six only
Wire Braided Hose & Electrical non-conductor Polyethylene Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is
95%, Applicable on Class B, C and electrically started Fire, Fire Rating 55B, Internal coating is not applicable & External coating is of enamel spray painting, Powder
Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO
( Petroleum and Explosives Safety Organization) APPROVED, Minimum Wall Thickness 4 to 4.2 mm, Extinguishers confirmed to IS 15683:2018 and ISI marked.
Referance Weight:-Gross Weight 16.4, empty weight 11.9 Kg, 1. Necessary certificate & and guarantee must be attached, 2. OEM has to provide wall mounting heavy
duty bracket/clamp, screw, hardware for installation. 3.Following printed marking Manufacturing Date and Expiry Date must be mention on Extinguisher 4. Refilling period
must be of 5 Years. Following Printed marking on equipment must be required:- Model No, Capacity, Gross Weight, Content, Fire Rating, Batch No, Serial no, Mfg Month,
Refilling Due. [with necessary numbering / marking with oil paint by painter as instructions given by G.S.P.H.C.L engineer] (Make: KANEX, MINIMAX , CEASEFIRE)
398 Providing and fixing of Automatic type 5 kg Fire Extinguishers Mono Ammonium Phosphate powder 50% Confirms to IS 4308, Applicable fire classes A,B & C, UGTS 3.00 Each 5240.00 RS: Five Thousand Two Hundred Forty only
Pressure Gauge, Can Height 370mm, Diameter 230 ± 10mm, Made up from 2 mm thick sheet, Body Construction Deep Drawn with MIG Welding technology, Brass
forged sprinkler valves with Nozzle is specially designed to give more than 99% discharge. Together with orifice characteristic to cover adequately fire risks with scattering
cone of 40 to 45° Angle. External Pure polyester (UV resistant) and Internal Epoxy polyester powder coated, Heat Sensitive Glass bulb of 68 °C. Area covered will be 2-2.5
m2 and volume of coverage is 7 m3. Referance Weight:-Empty Weight 2.64 kg, Full weight 7.64 kg, 1. Necessary certificate & and guarantee must be attached, 2. OEM
has to provide heavy duty wall/ Ceiling mounting Bracket/ clamp, screw, hardware for installation. 3.Following printed marking Manufacturing Date and Expiry Date must
be mention on Extinguisher 4. Refilling period must be of 3 Years. Following Printed marking on equipment must be required:- Model No, Capacity, Gross Weight,
Content, Fire Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with necessary numbering / marking with oil paint by painter as instructions given by G.S.P.H.C.L
engineer] (Make: KANEX, MINIMAX, CEASEFIRE)
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
399 SITC of 3LCD Lamp based projector having wxga (1280x800) or better resolution with minimum white brightness of 3800 lumens and color brightness of 3800 lumens. The 1.00 Each 33560.00 RS: Thirty Three Thousand Five Hundred Sixty
projector should have minimum 1HDMI,1VGA input. Having contrast ratio of 15000:1 or more. the projector should have auto vertical key stone correction of +/- 30 degree only
and Manual Horizontal of +/-30 degree. the projector should have optical lens, throw ratio 1.30-1.56:1. Zoom Factor of 1.2. Lens focus Manual having focal length 16.9mm
to 20.28mm. projector should have features like AV mute slide, quick corner and split function and should support wireless functionality with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ](Including Five year Warranty)[Make:- Epson EB-L210W / Sony / Panasonic]
400 SITC of 120 inch Self Lock MW (8 x 6) Instalock Slow Retraction Screen, Aspect Ratio-4:3 [Approved by Competent Authority i.e. not Below the rank of 1.00 Each 5282.00 RS: Five Thousand Two Hundred Eighty Two only
Executive Engineer ].[Make: Da-lite / draper / liberty / panara only]
401 Supply, Installation Testing & Commissioning 15 Mtr. HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed 1.00 Each 1760.00 RS: One Thousand Seven Hundred Sixty only
Specifications .[Make: Kramer / Extron / Crestron]
402 SITC of universal Projector mounting kit, with necessary grouting, fasteners etc. with adjustable height and suitable for all types of projectors. [Approved by Competent 1.00 Each 6781.00 RS: Six Thousand Seven Hundred Eighty One only
Authority i.e. not Below the rank of Executive Engineer ]
403 Providing and erecting water cooler having storage capacity 80 Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should 5.00 Each 49069.00 RS: Forty Nine Thousand Sixty Nine only
drop by 15˚C within a hour, The water cooler should be comprising of hermetically sealed compressor Reciprocating compressor with R134A gas , fan motor, Copper
Condensing unit, fan motor, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler
will be made from Stainless Steel, CP brass push cock, inlet float valve, with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection
to FD complete as required With 20 Amp. 3 pin plug Top with indicator. (This item including comprehensive service & maintanance including Spare Parts & consumable
item during warranty period of one year. Maintanance & service must be carried out by OEM dealer/distributer who has executed the work. Service & Maintance must be as
per OEM guid line.) (Agency has to give AMC to water cooler OEM / authorized dealer upto defect liability period] [Voltas, Bluestar, Usha model approved by EIC as per
404 Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, 5.00 Each 15466.00 RS: Fifteen Thousand Four Hundred Sixty Six
carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type post carbon filter auto low & high pressure switches with following size of storage tank only
& LPH capacity & erected as directed [B] 25 Ltr / Hr with 30 Ltr. Storage Tank [ ION EXCHANGE, AQUAGUARD, KENT, EUREKA FORBES, RAIN DROP, Make- Power
H2O, Blue mount appliances Pvt. Ltd.]
405 The purpose of RO plant is cater the portable and drinking water 24X7 to beneficiary.So we have taken comprehensive maintenance contract item in this tender. Agency 5.00 Each 13919.00 RS: Thirteen Thousand Nine Hundred Ninteen only
has to give All in All maintenance contract to OEM of RO plant and submit AMC copy to GSPHCL at the time of final bill.Agency has to submit FDR of Rs 69,595.00+ GST
or quoted amount whichever is higher to GSPHCL. Which will be released after successful completion of AMC & at the and of defect liability period. AMC consist of general
service & Filter shall be replaced at every 3 months.Membranes & booster pump shall be repaired/ replaced whenever required.Agency has to stick maintenance schedule
on the RO plant and date of service, TDS of water, discharge of water etc. shall be written on this.Agency has to receive certificate from beneficiary every year and submit
at the time of releasing SD.For 25 Ltr RO plant
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
Sr No. Description As Per SOR 2024-25 Total Quantity Unit Rate Rate in Words Total Amount
406 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized Aluminum 20.00 Per KW 42035.00 RS: Forty Two Thousand Thirty Five only
alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax: 0/+5,
Module Efficiency should be approx. 18%-21%, Normal operating temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass
diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV
modules of minimum fill factor 75% to be used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power
Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Anti-islanding Protection:
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current
Protection Integrated, Output Short Circuit Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: Seamless Box Pipe / 'C' Channel of suitable size for rooftop solar installations with good
stability agaist wind & weight load., Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be
suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of
stucture should be (SS 304) quality. and Balane of System with necessary Swithgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing
system, lightining arrester system, all liasoning work with various gov. department like state nodal agency,DISCOM & CEIG is included in agency scope
Grid Tied Solar Power System: For 20 kW (3 - phase)
407 Executing Com of solar Pv Modules, Inverter, wiring,earthing,switchgears, etc with material and labour cost including preventive maintanance.The cost covers entire 20.00 Per KW 10170.00 RS: Ten Thousand One Hundred Seventy only
installation. AMC also includes monthly site visit and inspection of project with submission of inspection and solar generation report. All parts should be replaced/repaired if
found faulty within specified time. Agency has to provide necessary liasoning work for warranty,power,Bidirectional meter etc of following Capacity as per terms &
condition of tender for defect liability period.Agency has to submit FDR of approved bank as per clause 2.0 section 3 Rs. 2,03,400.00+ GST or quoted rate which ever is
higher to GSPHCL,for minimum maturity period of four years in favour of GSPHC .Which will be released after succesfull completion of AMC & at the end of defect liability
period.Solar Agency has to maintain record of service & maintenance during defect liability period duly sign by Benificiaries and submitted regularly to GSPHCL & also get
satisfactory certificate from beneficiaries at the time of Defect liability period and copy of maintenance contract must be submitted during final bill. For 20KW( Per Tower)
TOTAL ELECTRICAL AMOUNT=
TOTAL CIVIL + ELECTRICAL AMOUNT=
Signature of contractor
Asst. Engineer Dy.Exe. Engineer Exe. Engineer
Ahmedabad Ahmedabad. Ahmedabad.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Nit No 15(25-26) Ammendment.pdf
SBD -1 Madhupura police station .....pdf
ALL CONDITIONS MADHUPURA.pdf
ATTACHED SPECIFICATIONS MADHUPURA.pdf
CEMENT CONSUMPTION MADHUPURA.pdf
DMO.pdf
ELE02 Tender Document Madhupura.pdf
ELE03 specifications Booklet.pdf
FINAL APPROVEED MAKE LIST LATEST.pdf
Genral Techinal Specification B S BOOK_ 24-3-23.pdf
SBD VOLUME 2 MADHUPURA.pdf
SBD VOLUME 3 MADHUPURA.pdf
SBD VOLUME 4 MADHUPURA.pdf
SCHEDULE B MADHUPURA.pdf
standard specifications madhupura.pdf
0.SITE LAYOUT PLAN.pdf
1.BASEMENT PLAN.pdf
2.GROUND FLOOR PLAN.pdf
3.FIRST FLOOR PLAN.pdf
4.SECOND FLOOR PLAN.pdf
5.THIRD FLOOR PLAN.pdf
6 FOURTH FLOOR PLAN.pdf
7.STAIR CABIN PLAN.pdf
8.LIFT MACHINE ROOM PLAN.pdf
9.FRONT ELEVATION.pdf
10.SECTION.pdf
01_FOUNDATION LAYOUT AND DETAILS-Model.pdf
02_FOUNDATION LAYOUT AND DETAILS-Model.pdf
03_FOUNDATION LAYOUT AND DETAILS-Model.pdf
04_FOUNDATION LAYOUT AND DETAILS-Model.pdf
05_FOUNDATION LAYOUT AND DETAILS-Model.pdf
06_FOUNDATION LAYOUT AND DETAILS-Model.pdf
07_PLINTH BEAM LAYOUT AND DETAILS-Model.pdf
08_PLINTH BEAM LAYOUT AND DETAILS-Model.pdf
09_PLINTH BEAM LAYOUT AND DETAILS-Model.pdf
10_PLINTH BEAM LAYOUT AND DETAILS-Model.pdf
11_FIRST SLAB BEAM LAYOUT AND DETAILS-Model.pdf
12_FIRST SLAB BEAM LAYOUT AND DETAILS-Model.pdf
13_FIRST SLAB BEAM LAYOUT AND DETAILS-Model.pdf
14_FIRST SLAB BEAM LAYOUT AND DETAILS-Model.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .