Loading…
Loading…
Tender ID
Tender Value
₹21.0 L
EMD Value
₹42,000
Closing Date
9 Mar 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Development of Jenab Sahib Shrine Soura Srinagar B.W.O Electric work
2026_PWDJK_304481_1
NIT No.305/2025-26 Dt/25/02/2026
Open Tender
Electrical Works
Percentage
SOURA
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹42,000
25 Feb 2026
25 Feb 2026
10 Mar 2026
25 Feb 2026
9 Mar 2026
25 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor (Polycab Green/Havell life guard/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc/Legrand Alzy /schneider Zencelo /Crabtree athena/ Eq. make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/Havell life guard/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.)single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor (Polycab Green/Havell life guard/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc/Allzy /schneider Zencelo /Crabtree athena make.)
Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/Havell life guard/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc/Legrand allzy /schneider Zencelo /Crabtree athena make.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC's
Supplying and fixing following modular switch/ socket ( Legrand Mylinc /schneider Zencelo /Crabtree athena make.) with modular plate and cover including switch box and connections etc. as required.
5/10 amps switch
15/16 amp switch
3 pin 5/10 amp socket outlet
6 pin 15/20 amp socket outlet
Bell push/ indicator
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Polycab Green/Havell life guard/ Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required.
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
( e ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
(f) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete
Supply and fixing of wooden channel/ casing made from Kashmiri Budloo wood having2.6"- 3" width suitable for carrying out wiring for different circuits.
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium body and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havell/ Helonix /Wipro make / sample to be approved before installation..
S/F testing and comm. Of 36 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Helonix/Wipro make / sample to be approved before installation..
Supply installation testing and commissioning of 36 W + ( 2 ftx2 ft) LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/Havell/Helonix /Wipro make / sample to be approved before installation..
Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
Supply installation testing and comm. Of 200mm - 250mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton /orient/equivalent make as directed by engineer incharge.
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate ( Legrand Mylinc/Legrand Alzy /schneider Zencelo /Crabtree athena/ Eq. make.)
SITC of wall fan 400 mm sweep as approved by EIC ,240v,50 Hz complete , etc. as required. Make(Usha /Orient/Crompton/ Havells
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.
Sub Head-3 - Distribution system
Supplying and fixing following way, triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/ABB/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
4 way, Double door ( 12+4)
8 way, Double door ( 24+4)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
16 way, Double door
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. legrand / Schinider/ABB ./equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
c) 40-63amp TPN MCB
Engaging of skilled labour for Dismentling of old damaged materials like wires in scraps, fixtures switches-sockets complete as directed by the engineer at site and stacking and handing over to concerned department including carrying out some repairing works etc.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick.
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
OUTGOING:
M.C.B 63 A F.P 10 Ka"C Curve
M.C.B D.P 40-63 A 10 Ka"C Curve
Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick.
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
OUTGOING:
M.C.B 63 A F.P 10 Ka"C Curve
M.C.B D.P 40-63 A 10 Ka"C Curve
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by G.I Strip. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
Supply, laying , testing and commissioning of PVC alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
a) 10 sq.mm 4 core
a) 25 sq.mm 3.5 core
b) 70 sq.mm 3.5 core
d) 95 sq.mm 3.5 core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Design,Supplying,Installation,Testing and Commissioning of Cubical Type outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick. ( As per approved design,size may vary as per site requirement) the job includes the angle iron stand of suitable size to be grouted in the cement concrete.
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)250 Amp TPN MCCB 50 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
b) 400 amp 4 strip bus 1 No.
OUTGOING:
a)160 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make.
c) space for 18 way MCB's
Supply installation testing and comm. of 7 Mt. octagonal M.S pole designed as per ILE TR7 and BS5649 for structrual design & as per IS 875 ( part III) 1987 for dynamic loading. M.S sheet thickness: 3mm Galvanization thickness 65 microns ( min) Door size:250mmx65mm, along with 4 No. foundation bolts Utkarash/ bajaj/crompton/ valmount make.
Providing of cement concrete block with dimensions( 2'x2'x4.5') including grouting 4 no foundation bolts, cement concrete to be carried in 1:2:4 mix.( RCC) including cost of M.S reinforcement ( as per approved drawing ) and cost of shuttering.
Earthing of the pole, Complete by GI Pipe 40 mm dia. 0.5 mtr long through 10 swg GI wire after driving in ground up to a depth of 3' from the base of foundation including nuts , bolts etc. (Complete job)
Supply and fixing of four way arm bracket( square type 2'x2') for mounting the luminaire on the top of the pole fabricated out of 48.3 mm OD GI pipe , welded and supported with a triangular MS gasset plate , with a provision of cast iron cap.( design to be approved before installation)
Providing of service connection and earthings to luminaire from the junction box in 1.5 mm PVC insulated, multicore copper wire .
Supply, installation , testing and commissioning of LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of greater than 120 lumen/Watt and a minimum system lumen output of 18000 lumens and maximum system wattage of 150 Watts.The fixture shall have a CRI of minimum 70, SDCM<5. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=07 with toughened glass cover.The fixture driver should have an operating voltage range of 140-270 V, inner surge protection of >=4KV, PF >0.95 and THD<10% at full load. Driver should cut off at high voltage of 320volt for safety. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics. Manufacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Philips/ Havell ( Jeta Aris)/ Wipro make ( sample to be approved before installation)
Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)in foundation of servo stabilizer set etc including form work etc as required the job also includes supply and carriage etc of the requsite material upto the site.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
BOQ_989030.xls
BOQ • 0.30 MB
corrigendumNIT305.pdf
PDF • 4.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .