Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹37.5 L+₹16,199 (0.43%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹37.7 L+₹37,095 (0.99%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹38.9 L+₹1.6 L (4.23%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹40.9 L+₹3.6 L (9.56%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L5 | Rejected-Finance not being L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
20 Mar 2024, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF DG SETS FOR INSTALLATION OF RETROFITTED EMISSION CONTROL EQUIPMENT/DEVICES (RECD) IN VARIOUS CAPACITY DG SETS UNDER AGE E/M NO-II OF GE (U-I) VISAKHAPATNAM
2024_MES_644824_1
8620/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹82,000
Yes
28 Mar 2024
1 Mar 2024
22 Mar 2024
1 Mar 2024
20 Mar 2024
15 Mar 2024
Amount
Supply, Installation, testing and commissioning Of Retrofit Emission Control Device (RECD) for 15 kVA Diesel Generator of make Cummins Category Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Catalytic Conversion The RECD Device should have a minimum specified Particulate Matter (PM) 2.5 capturing efficiency of 70% TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Technology (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar) (e) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana)
NOTE: a) Emission Control retrofit device shall be complete, with safety precautions to ensure no damage to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. b) Anti-Vibration mounting pads shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. c )Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. d) The Emission Control retrofit device and its outer covering shall be painted with corrosion resistive and Heat Resistance paint. e) The contractor shall provide the trial run (Testing) of Emission Control retrofit device. The contractor shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. f) The rate quoted includes Exhaust piping, extra civil work, distribution board shall be provided by the contractor at no extra cost. g) Maximum back pressure exerted by the Emission Control Retrofit Device should be within the maximum prescribed limits by the OEM after the installation of the RECD. h) The rate quoted by the contractor shall also include construction of earthing station (if applicable) along with necessary connections as per site requirement. j) The contactor shall facilitate the preventive maintenance of the RECD for a period of one year after the date of installation and two preventive maintenace visits from the respective OEM.
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 20kVA of make Cummins
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 32.5kVA of make Cummins
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 40kVA of make Cummins
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 62.5kVA of make Cummins
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 82.5kVA of make Cummins
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 100kVA of Ashok Leyland
All as per Sl Item No. 1.00 & 1.01 above but for DG Set of Capacity 100kVA of Make Cummins
S&F PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc, complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
S&F of 15A industrial power board with MCB of suitable capacity complete all as specified and directed. Make :- Havells / Anchor / Legrand / L&T
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. complete all as specified and directed.
S&F structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1998 grade St.-240 complete all as specified and directed.
M&L rolled mild steel conforming to Fe 290 (Gde E-165), in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) and including distance pieces, cleats etc. complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed. Make:- Colour Roof (India) Ltd / TATA Bluescope Steel Ltd / Dyna Roof / Bhushan Power & Steel Ltd / Prestar Infrastructure Projects Ltd.
All as per Sl item No. 17 above but plain steel sheet.
M&L 100 mm thick, PCC 1:2:4, type B-2 (using 40 mm graded crushed stone aggregate) as in sub base, floors, paths, plinth protection, pavings / hardstanding etc. finished even and fair complete all as specified and directed.
M&L PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
MVV Prasad
Lahoty Buildcon Limited
M/S CHANDRA ENGINEERS AND CONTRACTORS
R. S. Associates
UV POWER TECH
AYYAPPA CONSTRUCTIONS
SHIKHARA PROJECTS
Bhuvaneswari Electrical Works
M/s.DSRK CONSTRUCTIONS
G Srinivas Rao
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .