SH_C_O Pump House 2 Nos P_L_J and Testing of Rising main C_O Anchor block Supply and errection of pumping machinery with allied accessories complete for Ist and IInd stage Providing and fixing barbed wire fencing
2020_HPIPH_34307_1
IPH-KSG-0016
Open Tender
Pumps/Motors
Item Rate
182 days
Near village Kriya Khad and Near village Durknu
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
Yes
Executive Engineer IPH Division Karsog
₹1.0 L
Yes
12 Feb 2020
23 Jan 2020
7 Feb 2020
23 Jan 2020
6 Feb 2020
23 Jan 2020
Amount
Excavation in foundation, trenches ( for pipes & pits/other civil works) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chiselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration of un-metalled /metalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing and laying cement concrete 1:6:12( 1cement:6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and laying cement concrete 1:4:8(1cement:4 sand:8 crushed stone agg. 40mm nominal size)and curing complete excluding cost of form work in foundation and plinth in all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring shuttering ,strutting and propping etc.with wooden battens and ballies,height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for in situ reinforced concrete and plain concrete work in:-
Flat surfaces such as soffits of suspended floors roofs landings and the like floors etc. up to 200 mm in thickness in all leads and lifts.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillaster,buttresses plinth and string courses and the like in all leads and lifts.
Providing and laying cement concrete 1:2:4 ( 1cement:2 sand: 4graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement in:-
i) In foundation, footings basis of column.
i) suspended floors, domes, roofs,landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads and lifts.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete up to floor two level in all leads and lifts.
Random rubble masonary/Polygonal rubble masonary (coursed or brought to courses with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 in cement mortar 1:6 (1 cement : 6 sand) in all leads and lifts.
Boulder filling tightly hand packed under floor in all leads and lifts.
Brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:4 (1 cement : 4 sand) 1st Class in all leads and lifts.
Brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement : 6 sand) 2nd Class in all leads and lifts.
Half bricks masonry in common burnt clay building bricks in cement mortar 1:4 (1 cement : 4 Sand). In all leads and lifts.
Providing wood work in frames of doors,windows ,clerestorey windows and other frames wrought framed and fixed in position (2nd class deodar wood) in all leads and lifts.
Providing and fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestorey windows,including black enamelled iron butt hinges with necessary screws. 45 mm thick. 2nd class deodar wood in all leads and lifts.
Providing and fixing wire gauge shutter using galvanised MS wire gauge of IS gauge designatation 85 G with wire of dia 0.56 mm for door windows and clearstory windows including black enamelled iron butt hinges with necessary screws 40 mm thick 2nd class deodar wood with in all leads and lifts
Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round bars with round headed bolts and nuts by screws. Plain grills in all leads and lifts.
6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) in all leads and lifts.
15 mm cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) in all leads and lifts .
20 mm cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) in all leads and lifts .
Pointing on brick work with cement mortor 1:3 (1cement : 3 sand) Raised and Cut pointing in all leads and lifts.
Cement concrete flooring 1:2:4 (1 cement : 2 sand :4 graded stone aggregate 20 mm nominal size) laid in one layer finished with a floating coat of neat cement.40 mm thick in all leads and lifts.
White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt , dust and other foreign matters in all leads and lifts..
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink in all leads and lifts.
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matters, sand papering and stopping with enamel paint other than white in all leads and lifts.
Providing and fixing 40x3 flat iron hold fast 40cm long i/c fixing to frame with 10mm dia bolt nut and wooden pugs and embeded in cement concrete block 30x10x15 ( 1 cement:3 sand:6 graded stone aggregate 20mm nominal size) with in all leads and lifts
Providing and fixing oxidzed aluminuim sliding door bolts with nuts screws etc. Complete in all leads and lifts.
Providing and fixing oxidzed aluminium tower bolts ( barrel type) with screws etc. Complete in all leads and lifts.
Providing ad fixing oxidzed aluminium handles with necessary screws etc. Complete in all leads and lifts.
Providing and fixing oxidised MS hooks and eyes
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size in all leads and lifts.
1.20 metre heigh fencing (as per approved design) 1.80 metres R.C.C.posts 3 metres centre to centre and R.C.C. struts with 7 horizental lines and two diagonals of galvanised steel bar bed wire (IS 278-1962 type I) weighing 9.38 kg./100 metres (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of Excavation, R.C.C. Posts,R.C.C. struts and straining belts and embeded in cement concrete 1:4:8 ( 1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete in all respect and to the entire satisfaction of the Engineer-in-Charge. with in all leads and lifts
Steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in gratting, framed guard ber, ladders, railing brackets and similar works with in all leads and lifts.
1st Stage :-Supply & Errection of horizontal spindle, vertical split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & Platt/Kirloskar/Best & crompton/Lubbi/ Grounfos conforming to BIS 1520-1980 appropriate IS code (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti/ ABB/Morthon/Slip ring/squirrel cage screen protected drip proof induction eletric motor suitable for operation on the data given below:-
(A).SITE CONDITION :- (i) Location of Site :- Near Kriya Khad. Head Load Av-3.00 KM (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt :-1000 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-CLEAR COLD WATER. a) Dua & Length 80 mm 14800 mtrs (ix) NPSH available:-Positive Suction.
(B). OPERATING CONDITIONS :- Pumping Hours 16 Hours (i) Atitude o Installation above MSL Type of current:-AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :-8 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 30 degree centigrade.
(C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. x) Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
(xi) Type of slip ring gear whether Contineouslly rated for Squirrel cage/ contineouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:-Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No. of starts during a specified period:-To work the pump offered. (xiv) Where possible fault capacity of the system to which the motor is connected:- The motor should be able to withstand initial current of 2.5times the rated current for two minutes without suffering damages or permanent defomations.
(D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nos of pumps reqd:-2 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:-Air cock for exahausting air from each stage.
(E).PUMP OPERATING CONDITIONS :- (i) Capacity:-2.93 LPS. for each pump (ii) Total head in Mts.:-583.39 mtrs. (If total head is not known then follwing details be provided :- a) static Head: 566.50 mtrs, (b) Ground level mex. Water level: 816 (c) Ground level to delivery point: 1382 . (d) Length of Rising main: 1480 mtrs.) (iii) Dia of R/main:80mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 15% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a) duty head,b) (+) 10% head,c) (-) 15 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended).
Supply of suitable oil immersed ATS of standard make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
Providing, supplying and fixing digital VAF meter as per standard make latest with upto date amendments.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date amendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard/Havell's/Indoasian make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments.
Earth leakage circuit breaker of recomended (Kilburn/L&T/MET/GEC/Havell's as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of Kilburn/L&T/MET/GEC/Havell's /Indoasian make & suitable capacity.
Single phase preventor of L&T/Siemen/Schiender make & suitable capacity
Supply of Kirloskar/Kilburn /IVC/Fourcess/Gled/BHEL /Leader /Pelcom/KSB of reputed make of suitable size cast steel double flanged sluice valve having size one step higher to delivery of pump and capable of with standing nominal seat pressure of 104 Kg/CM^2 class ASA -600.
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 104 Kg/CM^2 class ASA-600..
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 104Kg/CM^2 of Class ASA 600.
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader/Kartar of reputed make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe :- PN1 provided with hand wheel/Cast iron Cap.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date amendments Siemen/Gloster/ICC/Havell's/Phenolic make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost..
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date amendments Siemen/Gloster/ICC/Havells/Finolex make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipes,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with GI plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm GI strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj/Havell's make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date amendments.
P/L suction,delivery pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-197 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
2nd STAGE :- Supply & Errection of horizontal spindle, vertical split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & Platt/Jyoti/Kirloskar/Best & crompton/Lubbi/ Grounfos conforming to BIS 5120 appropriate IS code (latest with upto date amendments) read with BIS 9137-1978 or latest to handle clear water with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti/ ABB/Morthon/Slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below:-
(A).SITE CONDITION :- (i) Location of Site :- Near Village "Durkanu" Head Load Av-2 KM (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt :-1000 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-CLEAR COLD WATER. a) Dua & Length 80 mm 3520 mtrs (ix) NPSH available:-Negative Suction.
(B). OPERATING CONDITIONS :- Pumping Hours 16 Hours(i) Atitude o Installation above MSL Type of current:-AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :-8 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 30degree centigrade.
(C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. x) Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
(xi) Type of slip ring gear whether Contineouslly rated for Squirrel cage/ contineouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:-Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No. of starts during a specified period:-To work the pump offered. (xiv) Where possible fault capacity of the system to which the motor is connected:- The motor should be able to withstand initial current of 2.5times the rated current for two minutes without suffering damages or permanent defomations.
(D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nos of pumps reqd:-2 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:-Air cock for exahausting air from each stage.
(E).PUMP OPERATING CONDITIONS :- (i) Capacity:-2.93 LPS. for each pump (ii) Total head in Mts.:585.11 mtrs. (If total head is not known then follwing details be provided :- a) static Head: 547.50 mtrs, (b) Ground level mex. Water level: 1379 (c) Ground level to delivery point: 1926 . (d) Length of Rising main: 3520 mtrs.) (iii) Dia of R/main:80mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 15% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a) duty head,b) (+) 10% head,c) (-) 15 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended).
Supply of suitable oil immersed star delta starter of standard make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
Providing, supplying and fixing digital VAF meter as per standard make latest with upto date amendments.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date amendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard/Havell's/Indoasian make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments.
Earth leakage circuit breaker of recomended (Kilburn/L&T/MET/GEC/Havell's as per BIS-2516-1977 with upto date amendments and of suitable range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circiut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of Kilburn/L&T/MET/GEC/Havell's /Indoasian make & suitable capacity.
Single phase preventor of L&T/Siemen/Schiender make & suitable capacity
Supply of Kirloskar/Kilburn /IVC/Fourcess/Gled/BHEL /Leader /Pelcom/KSB of reputed make of suitable size cast steel double flanged sluice valve having size one step higher to delivery of pump and capable of with standing nominal seat pressure of 104 Kg/CM^2 class ASA -600.
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 104 Kg/CM^2 class ASA-600..
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 104Kg/CM^2 of Class ASA 600.
Supply of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader/Kartar of reputed make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe :- PN1 provided with hand wheel/Cast iron Cap.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date amendments Siemen/Gloster/ICC/Havell's/Phenolic make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost..
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date amendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with GI plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm GI strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date amendments BHEL/GEC/Machneil/ Mager/Bajaj/Havell's make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date amendments.
P/L suction,delivery pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-197 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii).NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments (except the items where execution/laying included in particular item) Raw Water Stage, 1st stage & 2nd stage i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Providing, laying, jointing and testing in trenches to be levelled to grade IS marked MSERW/ API pipe ISO: 3183 L290 x-42-2007 of flanged pipe of following dia meters conforming to IS: 3182: 2000 (latest with upto date ammendments) having minimum wall thickness as specified below of steel grade jointed with flanges conforming to table as specificied below of IS: 6392-1971 (latest with upto date ammendments ) welded with at both ends according to relevant IS standard and detailed specifications and provided with nuts and bolts of required size 3mm thick compressed asbestos fiber gakset or synthetic rubber gasket conforming to relevant IS codes including all short pieces, bends, tees and other specials extra made from parent tubes and welded with flanges of tables as applicale to the particular reach and of approved specifications as per site condition including flushing, cleaning, painting and hydralic testing complete. The pipes and specials shall have galvanised coating as per ISO-4736 with latest ammendments at following RD's.
MSERW pipe 80 mm dia wall thickness 4.40mm Flange table-34 from RD 0 to 100=100 Rmt (Ist Stage)
MSERW pipe 80mm dia wall thickness4.40mm Flange table-34 from RD 0 to 200=200 Rmt (IINd stage)
Providing , laying,jointing ( by way of circumfrential butt welded joints in three layers by electrical arc welding ) and testing of API ISO 3183/2012 grade L-290 X-42 pipe of following dia meters confirming to ISO 3183-2012, (latest with upto date amendments) having wall thickness and grade as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe shall include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per IS:4736-1986 (with upto date ammendments) with mass og Zinc Coating as per relevant IS Code. The welding electrodes shall be as per IS 814:2004 of Advani Oerlikon/ L&T or ISI marked make. Negative tolerance in thickness and mass of pipes will not be accepted. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer-in-charge with in all leads and lifts. (Earth work in trenches shall be measured and paid for separately).(Refer Vol-II-Technical specifications & Vol-III, Data Sheet No. 2)(The diameter and Class /Material of pipe are indicative since the re-survey and re-design of proposal /scheme is to be carried out by the lowest bidder. The design /drawing so approved by the competant authority after finalisation of design and drawing ,any variation in size of pipe , material ,pipe class ,wall thickness, jointing , valves,specials etc. The rate shall be worked out on prorata basis after approval of the competant authority and will be paid accordingly.) (Refer to Technical specifications an data sheet No-6)
MSERW pipe 80 mm dia wall thickness 4.40mm from RD 100 to 480=380 Rmt (Ist stage)
MSERW pipe 80mm dia wall thickness 4.00mm from RD 480 to 960=480 Rmt (1st stage)
MSERW pipe 80mm dia wall thickness 4.40mm from RD 200 to 500= 300 ( IInd stage)
MSERW pipe 80 mm dia wall thickness 4.00mm from RD 500-2800 =2300 Rmt ( Iind stage)
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding in three layes) and testing of GMS Medium Class pipes of following dia meters confirming to BIS 1239 (Part-1), grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends, Tee etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately) 80 mm
80 mm dia (medium grade) wall thickness 4.00mm from RD 960-1480 =520 Rmt (Ist stage)
80 mm dia (Heavy grade) wall thickness 4.80mm from RD 2800-3200=400 Rmt (II Nd stage)
80 mm dia (Medium grade) having wall thickness 4.00mm from RD 3200-3520=320 Rmt (II Nd stage)
Oasis Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .