Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹8.0 L+₹50,043.35 (6.68%)Rejected-Finance C O CHOUDHARY 45 PEER BABA TARUSHAW ROAD HALWARA A D DISTT LUDHIANA PIN CODE 141106 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance OTHER THAN LOWEST. | |
| 3 | L3₹8.3 L+₹79,355.58 (10.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST. | |
| 4 | L4₹9.6 L+₹2.1 L (28.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST. |
Tender Value
Refer Docs
EMD Value
₹19,760
Closing Date
25 Nov 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge PIN-141001
Special repair to Bldg No T-313 (OTM Accn) of 943 Lt AD Regt Wksp at Dholewal Mil Complex under GE Ludhiana
2020_MES_386394_1
GE/LDH-45/2020-21
Open Tender
Civil Works
Item Rate
180 days
Dholewal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹19,760
Yes
11 Dec 2020
14 Oct 2020
26 Nov 2020
14 Oct 2020
25 Nov 2020
20 Oct 2020
14 Oct 2020 - 19 Oct 2020
Amount
Sch 'A' sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above gd level).Complete all as directed & specified by Engineer-in charge
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc. Complete all as directed & specified by Engineer-in charge
M&L, machine cut kota stone slab flooring 20 to 25mm thick bedded and jointed in cement slurry cement over screed bed 20mm thick in cm (1:6) and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, cutting and mirror type polishing Complete all as directed & specified by Engineer-in charge
-ditto- as per item herein above but in skirting/dado laid over 10mm thick cement screed in cm 1:4 Complete all as directed & specified by Engineer-in charge
M&L, 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone agg. as in sub-base/under flooring Complete all as directed & specified by Engineer-in charge
M&L, 50mm thick PCC 1:2:4Type B-1 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement.Complete all as directed & specified by Engineer-in charge
Taking down chowkats or frames n.exc 1.5 Sqm.(without taking off shutters) Complete all as directed & specified by Engineer-in charge
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frame).Complete all as directed & specified by Engineer-in charge
S&F, steel windows/ ventilator with side hung shutters incl box type hing. With glazing bars and steel peg stay. Each window shutter is to be fitted with 1 steel handle 100mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat. Complete all as directed & specified by Engineer-in charge
S&F, steel windows with side hung shutters incl box type hing. Without glazing bars and steel peg stay. Each window shutter is to be fitted with 1 steel handle 100mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat.Complete all as directed & specified by Engineer-in charge
S&F, mild steel Framed work such as grills, gratings, etc framed guard bars , ladders railings , frame of water tanks etc confirming to Fe 410 or Fe 310 Complete all as directed & specified by Engineer-in charge
S&F,galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or wire stapples Complete all as directed & specified by Engineer-in charge
M&L, two coats of synthetic enamel paint to untreated surfaces of steel over 10cm width or girth not otherwise described over a coat of red oxide primer after preparation Complete all as directed & specified by Engineer-in charge
S&F, pressed steel frames,size 125 X 60mm having thickness of mild steel sheet 1.25 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc.Complete all as directed & specified by Engineer-in charge
S&F, factory made 2nd class 35mm thick hard wood plain, framed, panelled shutters (any number of panels) with panels of 9mm thick BWP commercial ply.Complete all as directed & specified by Engineer-in charge
S&F, 35mm thick second class hard wood Glazed and skelton door shutters , open rebated and prepare to receive glass, gauge etc, size of members of shutters as specifed in SSR part I Complete all as directed & specified by Engineer-in charge
S&F, mild steel 300mm helical door spring , ordinary rat tail rod patteren including roller and roller plate Complete all as directed & specified by Engineer-in charge
M&L, Providing cement concrete type C-0 1:3:6 (12.5 mm graded agg) as for pressed steel chowkhats.Complete all as directed & specified by Engineer-in charge
M&L, two coats of synthetic enamel painting on wooden surfaces over a coat of pink primer inclding prepration of newly untreates surfaces.Complete all as directed & specified by Engineer-in charge
S&F, 150mm aluminium anodised barrel tower bolts of extruded section and fixed.Complete all as directed & specified by Engineer-in charge
S&F, 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.Complete all as directed & specified by Engineer-in charge
S&F, 125mm aluminium handles, cast type , anodised.Complete all as directed & specified by Engineer-in charge
S&F, second class hardwood small fittings as in shaped door/ window stops incl all necessary labours, articles n exc 200 cucm each Complete all as directed & specified by Engineer-in charge .
Dismantling wall and ceiling boards (Fibre, pulp, insulation, etc.) or insulation boards/slabs, any thickness, incl. cover fillets.Complete all as directed & specified by Engineer-in charge .
Dismantling framed timber scantling 40 sq cm and over in section in any position (framed work) Complete all as directed & specified by Engineer-in charge .
S&F, GI frame work 605 X 605mm grid for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate chennel 0.9mm thick having two equal flanges of 15mm each and web 45mm suspended from soffit at approx 900mm centre to centre with GI cleats and steel expansion fastener with and including ceiling section (not exc. 1.2m length) of 0.5mm thickness having kurled web of 50mm flange of 26 mm each with lips of 1050 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.Complete all as directed & specified by Engineer-in charge .
S&F, 4mm thick E-board , multipurpiose, decorative type,for ceiling purpose Complete all as directed & specified by Engineer-in charge .
S&F, Hangers 6mm dia GI (upto 1200 mm length) adjustjng level fixed to roof surfaces Complete all as directed & specified by Engineer-in charge .
Dismantling Asbestos cement corrugated or semi corrugated sheet in roof covering Complete all as directed & specified by Engineer-in charge .
S&F, pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as directed & specified by Engineer-in charge .
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as directed & specified by Engineer-in charge .
Dismantling wrought iron or mild steel work of any description not otherwise provided. Complete all as directed & specified by Engineer-in charge .
S&F, mild steel work confirming to Fe 290 grade-E -165 as in wind ties in roof covering.Complete all as directed & specified by Engineer-in charge .
S&F, Roof trusses (framed), trussed , purlins , crane gantries, rails etc (beam , tee , angle, channel or flat sections) Complete all as directed & specified by Engineer-in charge .
M&L, two coats of synthetic enamel paint to untreated surfaces of steel over 10cm width or girth not otherwise described over a coat of red oxide primer after preparation Complete all as directed & specified by Engineer-in charge .
Demolition of brick work built in cement mortar Complete all as directed & specified by Engineer-in charge .
M&L, Brick work with sub class "B" bricks straight or curved on plan etc 6 m mean radius in CM 1:4 Complete all as directed & specified by Engineer-in charge .
. -ditto- as above but except bricks.
M&L, 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finsihed the surfaces even and smooth without using extra cement. Complete all as directed & specified by Engineer-in charge .
M&L, 12mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finsihed the surfaces even and smooth without using extra cement. Complete all as directed & specified by Engineer-in charge .
M&L, for preparation of new plastered wall surfaces and applying three coats of whitewash Complete all as directed & specified by Engineer-in charge .
M&L for preparation of old plastered wall surfaces and applying two coats of whitewash Complete all as directed & specified by Engineer-in charge .
M&L, two coats cement base paint including preparation of newly plastered surfaces. Complete all as directed & specified by Engineer-in charge .
M&L, One coats cement base paint including preparation of old plastered surfaces.Complete all as directed & specified by Engineer-in charge .
Demolition of cement concrete of any description and in any position Complete all as directed & specified by Engineer-in charge .
M&L, cement concrete 1:2:4 type B-1 using 20mm graded stone agg as in roof kerb or mud stops, rounded or chamfered on edges Complete all as directed & specified by Engineer-in charge .
S&F in repair curtain rod made out of 25mm dia(outer dia )pipe having thickness 0.63mm , PVC coated and colour/pattern, over all dia 28 to 29 mm Complete all as directed & specified by Engineer-in charge .
S&F in repair plastic finial of 28 to 29mm bore, decorated type, of any colour/pattern, best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive Complete all as directed & specified by Engineer-in charge .
S&F in repair mild steel prepainted bracket to hold the curtain rod and fixed to wall(Concrete/brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the disturbed surfaces Complete all as directed & specified by Engineer-in charge .
M&L, 100mm thick PCC 1:4:8 Type D-2 using 40mm crushed stone aggregate as in sub base floor. Complete all as directed & specified by Engineer-in charge .
M&L, 80mm thick interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-40 Grade as approved by E-I-C laid in flooring and joints filled/broomed with fine sand. Complete all as directed & specified by Engineer-in charge .
M&L ,Sand filling under floors or in foundations incl. watering and consolidation.Complete all as directed & specified by Engineer-in charge .
M&L, PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in bed plates, coping, kerbs, water trough and like incl. rounded or chamfered on edges.Complete all as directed & specified by Engineer-in charge .
Sch 'A' sec-II
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. Complete all as directed & specified by Engineer-in charge .
Taking down Ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces Complete all as directed & specified by Engineer-in charge .
Refixing only ceiling fan and connecting up including provision sutiable of new down rod for ceiling fans,of cable from celling rose/ connector to fan Complete all as directed & specified by Engineer-in charge .
M &L, Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealed in walls/ceiling/roof/etc including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor fabricated steel terminal box made out of MS sheet concealed in walls with 3mm thick hylem sheet , ISI marked with chromium plated screws and cup washers for housing the sockets outlets, fan regulators etc incl with cutting of chases for conduit and sinking of boxes, all as specified and as directed for the following :-
One light/fan point controlled by one, one way switch
One switch socket outlet point 5 Amps on independent board
One 3 Pin socket outlet , 5 Amps on the same board with other switch
All as per item No.57 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.Complete all as directed & specified by Engineer-in charge .
Supply and fix, LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient Complete all as directed & specified by Engineer-in charge .
M & L, Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc Complete all as directed & specified by Engineer-in charge . Note : 2 runs of 6 sqmm, 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
M & L, Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc Complete all as directed & specified by Engineer-in charge . Note : 2 runs of 4 sqmm, 1 run of 4 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
Supply and fix, TPN MCB DB 4 ways 415 Volt, Double door type all as specified and as directed.
S & F, MCB TPN 40 Amps, 10 KA, C series 50Hz ,415 Volts complete all as specified and as directed.
Supply and fix, SPN MCB DB 8 ways 240Volt, Double door type complete all as specified and as directed.
S & F, MCB SPN 6- 32 Amps, 10 KA , C series 50Hz, 240Volts complete all as specified and as directed.
S & F, SP MCB 6-32 Amps 10 KA , C series 50Hz ,240Volts complete all as specified and as directed.
Supply and fix , ceiling rose surface type bakelite 65 x 50mm with three terminals Complete all as directed & specified by Engineer-in charge .
Supply and Fix, Switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed by Engr-in-charge
Supply and Fix, Socket outlet 3 pin, 5 A flush Piano,Flush type Complete all as directed & specified by Engineer-in charge .
Supply and Fix, Switch Socket combenation 2 in 1 outlet 3 pin, 5 A flush type Complete all as directed & specified by Engineer-in charge .
Supply and Fix, Switch Socket combenation 2 in 1 outlet 3 pin, 16 A flush type Complete all as directed & specified by Engineer-in charge .
S&F, fan regulator , fulsh stapped type ,electronic ,230 V, AC Complete all as directed & specified by Engineer-in charge .
S&F, study lamp 10 watt with AC adapter the stylish raylite come with adjustable angle can focus the light wherever you need and work with ease with suitable LED type Complete all as directed & specified by Engineer-in charge .
M &L, Earthing complete incl earthwork with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Supply, laying and testing complete, cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core as directed & specified by Engineer-in charge
Taking down of any size of bldg security light fittings complete all as specified and directed.
Supply and fixing, bldg security light fitting 30 watt made up of pressure die cast aluminium housing with potted Isolated driver and high power LED and individual lenses, operating range -90V to 340V AC. LED Life-1 Lac burning hours, Fixture should withstand 320V upto 48 Hrs, Auto Cut offf >320V & Restart, 440V Sustain upto 8 Hrs. External SPD-10K and 4KV inbuilt in driver, NABL Acreddited LM79 report, IP 66, complete all as specified and directed.
Excavation in trenches soft/ loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
Returning filling in including spreading, leveling ,watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
M & L ,Sand cushioning to UG cable with a layer of fine sand 8 Cms thick before laying of cable and 15 Cms thick after laying of cable in trenches complete all as specified. Note:- Thickness of 18cm after punning shall be considered for payment .
M & L, Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified
PREM CONSTRUCTION COMPANY
AGNIHOTRI CONSTRUCTIONS
JAY ANN CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .