Loading…
Loading…
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
4 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MAINTENANC
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650 V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected.
Similar Nature of Work: Supply, installation, testing and commissioning of LT/HT electrical GS assets ORSupply, installation, testing and commissioning of electrification or rewiring of building/workshop. ORSupply, installation, testing and commissioning of Yard/circulating area/street lighting/tunnel/facade lighting. ORSupply, installation, testing and commissioning of high-mast lighting. ORSupply, installation, testing and commissioning of glow signages. ORSupply, installation, testing and commissioning of LT/HT electrical GS sub-station with at least 50% capacity of proposed sub-station ORRepair/overhauling of LT/HT electrical GS assets including LT/HT sub-stations.
50 conditions · 8 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. and corresponding documents shall be submitted by the tenderer as per the composition of the Firm.
The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA of GCC and shall be valid for a period of 90 days beyond the bid validity period. Non-submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non- submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids.
Eligibility criteria :- Eligibility criteria shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
Tender Form (First sheet, Second sheet) of The GCC April 2022.
Certificate format (Affidavit) which available as Annexure - V in Mandatory documents. A facility has already created for online submission of Annexure V of GCC in IREPS module, uploading of physically signed Annexure V by tenderer has been discontinued.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
The corresponding documents shall be submitted by the tenderer as per the composition of the Firm: Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. HUF: (i) A copy of a notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. Partnership Firm: (i) All documents as mentioned in para18 of the Tender Form (Second Sheet). Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above. LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet). Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents andcreate liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as per Clause No.5 of PART -1 of The GCC, April 2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GTL Div: Provision of Power Quality Restorer in Electrical Installations and improvements to IGEA Recommdations (Phase-II).
GTL-EM-35-2026-27~SCOR
GTL-EM-35-2026-27
Open
Works - General
6 Months
Anantapur, Andhra Pradesh
₹0
₹4.4 L
13 Aug 2026
13 Aug 2026
21 Aug 2026
99 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,17,60,119.2 | ||
| — | 1.00 | — | — | ||
| Supply, Installation, Testing and commissioning of IOT Enabled (200kVAr + 50A AHF )Hybrid APFC Panel comprising of Active Harmonic Filter ( for mitigating the Harmonics upto 51st order) and 8 steps (50X3 kVAr- backup protection 125A MCCB 16 kA each, 25X1 kVAr backup protection 63A MCCB , 10X1 kVAr- backup protection 32A MCCB 16 kA , 5X3 kVAr - backup protection 16A MCCB 16 kA Followed by Main incomer MCCB- 500A 36KA. All Capacitors should be Super Heavy Duty MPP Cylindrical type along with 7% Detuned Copper Reactor H Class insulated winding. Bus bar shall be of copper. The APFC panel should be fabricated from 2mm CRCA sheet, IP42, floor mounting suitable for indoor installation. The Panel is made up of dust and vermin proof by providing good quality gaskets and doors, removal covers gland plate etc. all the live parts inside the panel would be covered with perforated sheet from the rear with fibre glass acrylic from the front as per the degree of protection specified. The Panel enclosure would be powder coated by minimum 11 tank processwith shades Siemens grey RAL 7032 of IS -5 or Orange. Cabinet doors will be equipped with concealed of detachable type hinges and with flush cylinders locks. All joint and connection will be made by galvanized or cadmium plated high tensile strength bolts, nuts and washer fully insulated and shall be sleeved. Bus bar shall be of copper and are completely covered. Capacitors, switchgears and panel should be manufactured completely in-house and from the same make. 8/12 Step Microprocessor based APFC relay consist of function: 3CT Sensing, 11mA current sensitivity, Automatic kVAr value sensing, wide band Aux supply 90-550V with multifunction electrical parameter display like Voltage, Current, Frequency, KW, KVA, KVAr, KWH, KVAH, kVAr and THD I and THD V, Automatic CT polarity error detection, selectable Step time and discharge time, selectable Target Power factor from lag 0.800 to lead 0.800 in step of 0.001. Alarm facility for over /under voltage, CT Polarity Capacitor :Super Heavy Duty Plus cylindrical type with ISI mark and BIS certification, and having overcurrent withstand capacity 3.0Ir, peak inrush current withstand capacity of 500Ir and having life of 3,00,000 hours. Detuned Reactor should have linearity upto In 225%, with Class H insulation and temperature protection switch(UL approved). The manufacturer should be necessarily certified by ISO 9001:2015, ISO 18001:2007, ISO 14001:2010, ISO 50001:2011. Hybrid APFC Panel also includes Selector switch AUTO/ Manual, TP Capacitor duty contactor with 230V AC coil & inrush current damping resistors 50 kVAr -3Nos, 25 kVAr -1 Nos, 10 kVAr -1No, 5 kVAr - 3Nos, AHF unit and illuminating manual switch, control mcb 6A for protection, fan and louver for ventilation. Make: ABB/L&T/ C&S/ Legrand,/ Hager/ Schnider/ Siemens/ Havells or equivalent.Inspection certificate to be provided by RITES/Govt authorised third party agency. | — | — | — | 8,65,841.4 | |
| — | 3.00 | — | — | ||
| Supply, installation & testing and commissioning of 440V, 50 Hz, 10 KVAr Passive Harmonic Filter as per IEEE 519 standards with Ambient Temperature upto 50 deg with 3 phase aluminium wound reactors with iron core, with filtering factor of 7% with >0.95 linearity, H-class insulation, vaccum impregnated with power capacitors. | — | — | — | 95,049 | |
| — | 9.00 | — | — | ||
| Supply, installation & testing and commissioning of 440V, 50 Hz, 5 KVAr Passive Harmonic Filter as per IEEE 519 standards with Ambient Temperature upto 50 deg with 3 phase aluminium wound reactors with iron core, with filtering factor of 7% with >0.95 linearity, H-class insulation, vaccum impregnated with power capacitors. | — | — | — | 1,78,150.5 | |
| — | 2.00 | — | — | ||
| Design, Manufacturing, Supply, installation, testing and commissioning of 40HP/30KW VFD panel for air compressor with 1.6mm CRCA sheet with IP54 with 100A 3P main incomer Microprocessor based LSIG MCCB,>30KW compressor VFD, Louvers, Breaking resistor, Pushbuttons start/stop/speed increase/Speed decrease/Reset, Indication Lamp Run/Trip, required size copper busbar, Ventillation fan, wiring. Panel should be complete in all the respects. Panel should Conform to all applicable Indian/International standards.(Prior Approval to be taken before supply). | — | — | — | 6,68,038 | |
| — | 1500.00 | — | — | ||
| Supply and painting of solar Thermo-Reflective Exterior Coating For Cooling Of Roof Top terraces as per standard specifification. Consginee inpection | — | — | — | 14,85,000 | |
| — | 1.00 | — | — | ||
| Supply, installation & testing and commissioning of 440V, 50 Hz, 300 KVAr Static Var Generator Input Voltage Range: AC 228 480 V, Rated Capacity per Module: 50 kvar / 100 kvar, Harmonic Elimination Range: 2nd 25th order (Selectable), Harmonic Current Capacity: 20% of rated current, Reactive Power Compensation Performance: Cos 0.99 after compensation Full Response Time: < 10 ms, Instant Response Time: < 100 us , Control Frequency: 30 kHz, Controller: DSP + FPGA, Waveform Display: Input Voltage waveform, Grid current waveform, Load current waveform and SVG current waveform , Communication : Modbus RTU (RS-485), Modbus TCP/IP (Ethernet) IP Grade of Cabinet: IP55, Cooling Method: Intelligent forced air cooling, Noise Level: < 65 dB(A) @ 1 m (Module) confirming to all indian/international standards with Ambient Temperature upto 50 deg | — | — | — | 6,50,000 | |
| — | 16.00 | — | — | ||
| Provision of Foundation/Platform for installation of Switchgear panels. | — | — | — | 3,11,832.8 | |
| — | 1800.00 | — | — | ||
| "supply and installation of the Single line diagram Boards including preparation of Diagram. The price shall include the supply and installation of fabricated Single Line Diagram Boards of various sizes at designated locations etc. The boards must be fabricated using 3 mm thick ACP (Aluminium Composite Panels) sheets, supported by iron framing, and finished with aluminium beading for durability and a professional appearance. The SLD drawings shall be printed on adhesive vinyl, with different feeders distinctly marked in different colours for clarity. Installation of the boards shall be carried out in accordance with the requirements and directions of the Railway Engineer In- charge. Note: Dimensions of diagram boards are to be decided in consultation with Railway Engineer In-charge( Cosignee Inspection) " | — | — | — | 22,87,800 | |
| — | 30.00 | — | — | ||
| Supply of Complete tool kit with Briefcase size (18"X14" inch) as per technical specifications attached.. | — | — | — | 22,32,000 | |
| — | 50.00 | — | — | ||
| "Supply of checkered anti-skid design electrical insulating rubber mat of size: Width (in mm) 1000 to 2000 Length (in mm) 10000 confirming to IS:15652 (2006) for HT panel for working voltage3.3 KV or above for As per GeM contract no. GEMC - 511687730024326" | — | — | — | 2,40,050 | |
| — | 20.00 | — | — | ||
| Supply of Raint Suit and rain coat included componenets Rain Suit Set of size XL Brand: HANS BACK (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC511687707531308 dt.22/01/2026) | — | — | — | 10,500 | |
| — | 20.00 | — | — | ||
| Supply of 6 Kg Portable fire extinguisher DCP type with nozzle and discharge fitting for ABC class of fire having ISI mark to IS-15683/2018 Rev.1. . Fire Extinguishers having composite/SS/Aluminum cylinder of same fire rating as per latest IS-15683:2018 Rev.1. Warranty Period : Upto 30 months from the date of supply | — | — | — | 50,976 | |
| — | 20.00 | — | — | ||
| Supply of Industrial Safety Belt as per GeM Contract No. GEMC-511687789746324 | — | — | — | 24,000 | |
| — | 20.00 | — | — | ||
| Supply of Safety Helmet to the specifications in IS 2925 :1984 and EN 387 -2012 of Blue color (Warranty Period : Upto 30 months from the date of delivery.) | — | — | — | 3,060 | |
| — | 15.00 | — | — | ||
| Supply of 25 KV Earthing/Discharge Rod assembly as per RDSO Specification.No. ETI/OHE/51(9/87) with A & C Slip No.1 or latest. Note: Test Certificate from NABL should be submit along with supply. | — | — | — | 1,67,796 | |
| — | 140.00 | — | — | ||
| Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single plate including holes etc. complete as required | — | — | — | 85,260 | |
| — | 140.00 | — | — | ||
| Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. | — | — | — | 59,080 | |
| — | 140.00 | — | — | ||
| Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. | — | — | — | 19,460 | |
| — | 1400.00 | — | — | ||
| Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) | — | — | — | 2,07,200 | |
| — | 1400.00 | — | — | ||
| Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) | — | — | — | 3,33,200 | |
| — | 2100.00 | — | — | ||
| Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. | — | — | — | 4,64,100 | |
| — | 5.00 | — | — | ||
| Supply and fixing of 6 A-32 A 4P MCB C Curve , 10 KA capacity with necessary connections and all accessores complete. | — | — | — | 8,837.5 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connections as required. | — | — | — | 1,59,040 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections as required. | — | — | — | 1,71,220 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button as required. | — | — | — | 71,820 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button as required. | — | — | — | 62,160 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections as required. | — | — | — | 31,080 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of fire alarm sounder with announcement facility, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier including line matching transformer as required. | — | — | — | 84,000 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of talk back slave station in surface/recess suitable for simplex mode complete with P.T.T. knob & speaker/microphone in M.S. (16 SWG)/ABS box with break glass as required. | — | — | — | 1,34,820 | |
| — | 140.00 | — | — | ||
| Supplying, installation, testing & commissioning of 4 Zone sector panel suitable for zones with visual indications for short circuit fault, open circuit fault, fire condition and IS:2189 compliance including mimic diagram for all areas. | — | — | — | 13,73,120 | |
| — | 14000.00 | — | — | ||
| Supplying & laying of 2x1.5 sqmm fire alarm armoured cable (600/1000V) with copper conductor, XLPE insulation, steel armouring & FRLS/HFFR outer sheath. | — | — | — | 26,88,000 | |
| — | 11200.00 | — | — | ||
| Supplying and fixing of 25 mm size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | — | — | — | 18,81,600 | |
| — | 75.00 | — | — | ||
| Supply, fixing and connecting of 2 pole 16A RCCB of 30mA s conforming to IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity as advised by the site supervisor with all necessary accessories complete | — | — | — | 2,03,917.5 | |
| — | 200.00 | — | — | ||
| Supply and fixing of RCCB 2P 25A 30mA with metal enclosure. RCCB conforming to IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity as advised by the site supervisor with all necessary accessories complete | — | — | — | 5,43,780 | |
| — | 250.00 | — | — | ||
| Supply, fixing and connecting of DP 32A 30mA RCCB conforming to IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity and as advised by the site supervisor with all necessary accessories complete | — | — | — | 6,94,050 | |
| — | 15.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of RCCB 2P 40A 30mA Sensitivity conforming to o IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity with all necessary accessories complete as advised by the site supervisor. | — | — | — | 41,643 | |
| — | 10.00 | — | — | ||
| Supply, fixing and connecting of RCCB 2 Pole, 63A, sensitivity 30 mA, breaking capacity 10 kA, 230 Volts AC, 50Hz, ISI marked conformingo IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity latest as advised by the site supervisor with all necessary accessories complete. | — | — | — | 36,365 | |
| — | 60.00 | — | — | ||
| Supply, fixing and connecting of 4P 32A 30mA RCCB conforming to IS 12640-1 & IEC 61008-1 with 10 kA short circuit withstand capacity as advised by the site supervisor with all necessary accessories complete | — | — | — | 2,14,056 | |
| — | 40.00 | — | — | ||
| Supply and fixing of RCCB 4P 40A 30mA ELCB/RCCB and metal enclosure conforming to IS 12640-1 & IEC 61008-1 and as advised by the site supervisor with all necessary accessories complete | — | — | — | 5,10,260 | |
| — | 30.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of RCCB 4P 63A 30mA Sensitivity conforming to o IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity and as advised by the site supervisor with all necessary accessories complete | — | — | — | 1,13,697 | |
| — | 5.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of RCCB 4P 63A 100mA Sensitivity conforming to o IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity with all necessary accessories complete as advised by the site supervisor. | — | — | — | 18,949.5 | |
| — | 5.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of 100 A 4 pole RCCB/ELCB with suitable Metal Enclosure Operating Sensitivity 100 mA and overload protection, Test button Facilitates to check healthiness of device by creating an artificial electrical fault with T marking, Dual Termination suitable for Busbar and / or wire up to 50 sq mm , Finger-proof terminal IP 20, Combined screws, Suitable for Isolation, Type: , current setting type adjustable /variable, Rated Voltage 240/415 V AC, Rated Insulation Voltage 600 V , Rated Impulse Withstand Voltage 4kV Rated Snap-fit on 35 mm Din- Rail, Degree of Protection IP 20, 50 Hz , Short Circuit Current 10 kA. | — | — | — | 41,905 | |
| — | 69.00 | — | — | ||
| Supply and fixing of FP MCB/RCBO enclosures model no.5077 93 of legrand make or its equivalent with required dummies and other accessories complete | — | — | — | 63,618 | |
| — | 150.00 | — | — | ||
| "SUPPLY AND INSTALLATION OF SET OF AEROSOL FIRE DETECTION & SUPPRESSION SYSTEMCONSISTING OF FIRE SUPPRESSION SYSTEM CARTRIDGES OF 100G - 1 NO., SENSING CABLE - 1 NO.,ACTUATING DEVICE 1 NO., AS PER THE TECHNICAL REQUIREMENT SPECIFIED IN THE ANNEXURE SPECIFIED IN THE ANNEXURE G1 OF SPEC NO RDSO/PE/SPEC/AC/0192-2018(REV-1). THIS SHALL BE INSTALLED IN LT PANELS OVER THE GTL DIVISION. ALL MODIFICATIONS, BACK PIECES, INSTALLATION BRACKETS & ACCESSORIES REQUIRED FOR INSTALLATION OF THIS ITEM SHALL BE WITHIN THE SCOPE OF SUPPLY. ONLY RDSO2 APPROVED MAKES WILL BE ACCEPTED. MATERIAL TO BE PROCURED FROM OEM/AUTHORISED DEALER OF OEM. CERTIFICATE OF AUTHORISED DEALERSHIP TO BE SUBMITTEDALONG WITH TENDER. PROOF OF PURCHASE OF MATERIAL FROM OEM/AUTHORISED DEALER TO BE SUBMITTED ALONG WITH SUPPLY. TEST CERTIFICATES AS PER RDSO SPECIFICATION SHALL BE SUBMITTED ALONG WITH SUPPLY Make- Any RDSO Approved Make. " | — | — | — | 17,52,300 | |
| — | 3.00 | — | — | ||
| Supply and installation of 250 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communcation capable conform to IEC 60947-2 or it's equivalent with extended ROM , spreader links (2 sets) of model no: IHQT2EF50250 of havells or its equivalent | — | — | — | 1,44,837 | |
| — | 2.00 | — | — | ||
| Supply and installation of 200 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communcation capable conform to IEC 60947-2 or it's equivalent with extended ROM , spreader links (2 sets) of model no: IHQT2EF50200 of havells or its equivalent | — | — | — | 96,558 | |
| — | 2.00 | — | — | ||
| Supply and installation of 160 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communcation capable conform to IEC 60947-2 or it's equivalent with extended ROM , spreader links (2 sets) of model no: IHQT2EF50160 of havells or its equivalent | — | — | — | 94,248 | |
| — | 4.00 | — | — | ||
| Supply and instllation of thermal magnetic based release ; Icu = 36kA; 100A 4 Pole MCCB conform to IEC 60947-2 of model no. IHQT2EC50100 of Havells make or it's equivalent with extended ROM , spreader links (2 sets). | — | — | — | 71,974 | |
| — | 5.00 | — | — | ||
| Supply and fixing of 40/50/63A 4P MCB C Curve , 10 KA capacity with necessary connections and all accessores complete. | — | — | — | 13,870 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CEGE Technical Circular
ATTACHMENT
ListofLikelySuppliers.pdf
ATTACHMENT
GCC Apr 2022 with Correction slips
ATTACHMENT
EarthingSpecificationMFEandOther.pdf
ATTACHMENT
RITESInspection.pdf
ATTACHMENT
NITIREPSWorks35.pdf
ATTACHMENT
APFCPanel.pdf
ATTACHMENT
Scopeofworkforwiring.pdf
ATTACHMENT
CPWDGeneralspecelectricalworks_compressed.pdf CPWD Specification of Elect works
ATTACHMENT
FirepreventionGuideline.pdf
ATTACHMENT
CEGETechnicalCircular07-04-2022_compressed.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips._compressed.pdf
ATTACHMENT
CPWDGeneralspecelectricalworks_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].