Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹30.8 L+₹2.2 L (7.59%)Rejected-Finance | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹32.3 L+₹3.7 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Due to 3rd lowest. | |
| 4 | Rejected-Technical | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
11 Feb 2022, 6:00 pmClosed
EE_PED_PWD
RANCHI ROAD_PURULIA
Special repairing of electrical installation including supply_ installation_testing and commissioning of DG Set and Fire Detection and Alarm System, Muradih BPHC_ Purulia_RN.21001275_ Project ID_ HF212247350S000
2022_WBPWD_361929_1
WBPWD/EE/PED/NIQ39 /2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
42 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹80,000
9 Nov 2022
21 Jan 2022
15 Feb 2022
22 Jan 2022
11 Feb 2022
22 Jan 2022
Amount
Electrical Installation Sub-Head:-1 (Distribution Wiring) Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit 'FR' (Brand approved by EIC) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] [E-16/6]
Average run 8 mtr [E-16/6(c)]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish [E-15/4]
On Board [E-15/4(a)]
Average run 6 mtr [E-15/4(e)]
Sub-Head:-2 ( Computer Point, Power Point) Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-7/26]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-6/22]
Sub-Head:-3 ( Power Socket, A.C. Starter, Top) Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module PVC Modular type switch board with top cover plate flushed on wall and making necy. connections with PVC Cu wire and earth continuity wire etc.[E-17/5(a)]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17/5(b)]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module PVC Modular type switch board with 4 Module top cover plate flushed on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/17]
Sub- Head:-4 ( HTPN,SPN DB, Panel) Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14]
4 way Make:-L&T [D-11/14]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[NS]
2+10 way Make:-L&T Enclosure (LTSD12N) [D-10/13]
Sub-Head:- 5 (ISO,MCB,MCCB, SFU) Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A DP Make:-L&T [D-5/6]
63 A FP Make:-L&T [D-5/6]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
32 A SP Make:-L&T [D-6/7] for SPNDB
20 A SP Make:-L&T [D-6/7] for Ac Point or others
16 A SP Make:-L&T [D-6/7] for Power Point
10 A SP Make:-L&T [D-6/7] for Computer Board
6 A SP Make:-L&T [D-6/7] for Switch Board
Sub-Head:-6 ( Supply of Cable) Supply of following 1.1 Kv grade XLPE insulated Armoured Aluminium cables- [NS ]
2 core 6 sqmm cable for roof top light [NS]
4 core 25 sqmm cable [NS]
Sub-Head:-7 ( Laying of Cable) Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(a)]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
Sub- Head:-8 (Gland, Socket) Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
upto 2 core 6 sqmm [F-4/7(a)]
for 4 core 25 sqmm [F-4/7(c)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 core 6 sqmm cable [F-5/8(b)(ii)]
4 core 25 sqmm cable [F-5/8(b)(xiii)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
1.5sqmm [NS]
2.5sqmm [F-5/9(i)]
4 sqmm [F-5/9(ii)]
6 sqmm [F-5/9(iii)]
Sub-Head:-9 ( Copper Wire, polythine Pipe, inpection box) Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required [E-14/1(a)]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a)(i)]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a)(ii)]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-14/1(a)(iii)]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [E-14/1(a)(iv)]
Sub-Head:-10 ( Supply Light, Fan, Bulb) Supply of 4' 18W T8 LED tube light with complete set (Make:- Philips TMC 501 P 1xT-LED 22W P3241, including Mas LED tube 1200 mm 18W 865 T 8 I-2100 lm )
Spply of 230 V, AC Ceiling fan complete with blade, canopy, down rod upto 1 ft.1200 mm (48") sweep, ORIENT:-NEW BREEZ [NS]
Supply & fixing of 9'' sweep AC exhaust fan (EPC heavy duty) 1370 r.p.m. and S& F louver Al with nuts and bolts. [NS]
Supply of LED street light of following specifications on the roof top -Crompton FREEDOM NEO Light, 45 WATT, Model:- LSTS-45-CDL-M/ Equivalent make of Bajaj/ Havels. [NS ]
Supplying & Fixing LED bulk head light fitting (Make:-Philips, Model:-WT140W LED 7S CW PSU SI PC )/ equivalent make of Crompton/ Bajaj.
Supply of 10W LED lamp 3000k (Make:Crompton/ Philips / Havells ) [NS]
Sub-Head:-11 ( Fixing Tube and Led street light Light,ceiling fan, Exhaust Fan) Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2/17]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2/16]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [C-3/21(a)]
Extra for suspension exceeding 25 cm with S&F additional 1 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 3x24/0.20 mm (1.5sqmm.) flexible copper wire.
Fixing only lamp [C-2/11]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [D-13/22]
Sub-Head:-12 ( Call Bell, Fan clamp, Fan Regulator,Minipole with Muffing , Starter ) Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [D-14/29]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [E-6/18(a)]
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making onnections as required and mending good damages to wall and painting [C-3/19]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive [H-5/H(5)]
Supply & Fixing two nos of 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board and 1 No 6A SP MCB incl.S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required for Street Light
Sub-Head:-13 ( Earthing) Excavation of soil for installation of Earth Electrode and filling & ramming. [G-1/1]
For Morrum Soil [G-1/1(b)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe [G-1/2(a)]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [G-2/4(a)]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid GI Wire No. 4 SWG [G-2/5(a)(i)]
Sub-Head:-14 ( S&F AC ) Supply & Delivery of 1.5 TR capacity, 5 Star BEE rating (2020) BTU - minimum 18016 BTU/Hr, Compressor-DC Twin Tropical Rotary type split type AC machine (Image sensor Technology) with copper coil arrangement with all modernized provision such as auto humid control, On/Off timer, Twin motor technology, 4 way air swing, auto filter clean indicator, auto restart, auto power save mode, auto fan speed, eco-green refrigerant R-32, Make:- Daikin, Model:-Indoor:-FTKF50TV16U, Out-Door:-RKF50TV16U/ equivalent make of Hitachi/ Blue Star/ Carrier). [NS]
Installation, Testing & Commissioning of above split type Air- Conditioner machine.
Supply and Installation of M. S. angle Bracket, making a hole including fixing accessories for providing condensing unit and cooling unit mending the good damages.
Supply & laying 5/8" & 1/4" copper pipes with thermal foam tube insulation with 5/8" drain pipe for AC machine incl. S & laying 4 core 4 Sq. mm round copper cable.
Sub-Head:-15 (SPD) Suplly and fixing S.P.D. Type-1 & 2 with Sheet Steel Encloser with Necy connection Make:-HAVELLS,CODE NO- DHSAANBC50320 SPD -Number of poles:- TP+N Uc (V)-320, In (kA)-20, Iimp(KA)- 12.5. Imax (kA) - 50 Up (kV)-1.5, Remote Signaling-No. Cartridges- DSSRCX0150, Pole- N - PE. Connection capacity with flexible cable for earth:- 35 mm²
Supply & drawing of the 1.1 kv.gr. Single Core 35 sq mm unarmoured Copper.cable (Glostar/Polycab/KEI/Havells) (for Type-1 &2 SPD) [NS]
Finishing the end of following copper cable by crimping method incl. S & f socket, tapes,anti corrosive paste & jointing materials as reqd.
Single core 35 sq mm Cu cable [NS]
Labour charges for making holes on busbar incl providing brass/GI nuts,bolts as applicable of adequate size, washers,spring washers etc as reqd. for SPD connection.
Sub-Head:-16 (Dismental Charges ) Dismental charges for existing electrical Wiring on Hospital
Sub-Head:-17 (SITC of DG Set ) Supply,delivery at site on foundation,commissioning of 100 KVA , 415V, 50 Hz, 3 phase new DG set,comprising of Engine,alternator,separate AMF panel,base frame,Fuel tank,Battery,CPCB-II approved Engine & Acoustic Enclosure having following specifications:- (Make:-Jackson/Kirlosker Green/ Ashoke Leyland/ Mahindra/ Graves Power)
Generator Specifications:- Genset manufacturer:-Jackson/Kirlosker Green/ Ashoke Leyland/ Mahindra/ Graves Power Genset rating:-Prime Genset output (kVA/Kwe):-100/80 Genset Model:-GPWII-PII-100 "Engine rating (Max power @ rated RPM in KW(BHP):-93(126.4)" Engine model:-4G11TAG25 Aspiration/Cooling:-TCAC/Radiator No. of cylinders/Cylinder arrangement:-4/Inline Displacement (L):-4.87 Bore x Stroke (mm):-108 x 133 Compression ratio:-16.8 Rated RPM:-1500 Governor: Type/Class of governing:-Mech. / G2 Frequency regulation: No load to full load:-Isochronous Overspeed trip (RPM):-1650
Alternator Specifications:- Make- Stamford/Leroysummer Voltage (V):-380 - 440 Frequency (Hz):-50 Current @ 0.8 PF (Amps):-139 Type:-4P, rotating field "Exciter type:-Brushless (PMG optional)" "Leads: Qty/Type:-6 fixed Optional 12 reconnectable" Voltage regulator:-Solid state Insulation:-Class H Temperature rise (Deg C):-125 Bearing: Qty/Type:-1, sealed Coupling:-Flex disc "Voltage regulation: No load to full load:-2P sensing, ±1%" One step load acceptance:-100% of rating Unbalanced load capability:-25% of rated current
ACOUSTIC ENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-II norms.
BASE FRAME Common iron channel fabricated base frame containing the engine and alternator ,mounted on AVM pads and having provision for lifting Hook.
Supplying & erection of foundation of 100 KVA D.G.Set(silent) at outdoor having dimension given below a)4 inch deep(below ground)PCC of size 4000 mm x 2000 mm & 300 mm above G.L. b) 15 inch thick brick wall,4 inch deep PCC keeping central part as follows- c) Filling the hollow portion with mixture of sand & shifted soil. d) 6 inch deep RCC with 8 mm double mesh rod at the top of the brick foundation of size 4000 mm x 2000 mm x 300 mm incl providing foundation bolts,jum nuts etc.
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts [G-1/2(d)]
Extra of treatment of soil by using salt & charcoal for pipe electrode.[G-2/3(b)]
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS.(Morrum soil)[G-1/1(b)]
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. [G-3/5(d)]
S & F compression type gland complete with brass gland,brass rings & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable as below
upto 4 core 6 sqmm [F-4/7(c)]
upto 4 core 70 sqmm [F-4/7(c)]
Finishing the end of following XLPE/PVC armoured cable by crimping method incl. S &F solderless socket (Dowels make) tapes anticorrosive paste and jointing materials
4 core 10 sqmm cable [F-5/8(b)(xi)]
4 core 70 sqmm cable [F-5/8(b)(xvii)]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required [F-6/11]
65 mm dia [F-6/11(e)]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Gloster/Havells]
4 Core 6 Sq. mm
4 Core 70Sq. mm
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [D-2/3(a)]
415V FP 160 A Make:-L&T [D-2/3(a)]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
32A Make:-L&T [D-3/4(a)]
160A Make:-L&T [D-3/4(a)]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [F-2/1(a)]
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed [F-2/1(b)]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(d)]
Sub-Head:-18 (SITC of FDA System ) Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent optical -Thermal multi-criteria detector, .(Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton).
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (MCP). (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton).
Supply, Installation, Testing & Commissioning of Addressable sounders/ stobers/Hooters . (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation, Testing & Commissioning of LED type Response Indicator. (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton).
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Addressable Fire Alarm control Panel.(FACP) having expandable and fully networkable features suitable for handling all the detectors and devices for this project. It can be suitably configured according to the OEM loop capacity, Deatiled specification given in Annexure-A . (Approved make: Honeywell/ Siemens / Secutron/ Edward / Bosch Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / RR Kabel/ Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium)
Supply, Installation, Testing & commissioning of of 7AH - 12 Volt DC battery for standby power supply system for Main FACP, (Make: Exide\Amaron/APC).
NOTE: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the |adjustments and tests for the system. 2. Before energizing | the cables and wires, inspection and check for correct |connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/lnternational standards must be done. 3. As built drawing shall be submitted in Both soft (CAD) & hard copy |format..Drawing shall be approved by the Engineer in charge before the commence of the work. 4. Necessary Certificate from the Competent Authority / Statutory body should be obtained by the executing agency if asked by ElC 5. The work shall be completed in all respect and shall be free from all kinds of defects/deficiencies/damages in equipment, materials, components and other auxiliaries and workmanship from any cause whatsoever for a period of Three years warrenty or, total replacement in case of major defects or fault for both the FACP and the battery. 6.Test Certificates of individual components may be produced if asked by ElC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required [E-14/1(a)]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1(a)(ii)]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-6/22]
Supply and Delivery 1KVA Online UPS (Make:-APC, SRC1KI-IN) for court fire detection System
R.D.ELECTRICAL ENGINEERING CO
SANANDA ELECTRIC
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .