Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 13 RAMLAL MUKHARJEE LANE P O KHAGRA P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.6 L+₹15,227.20 (0.78%)Rejected-Finance STRAND ROAD BABUGANJ CHINSURAH HOOGHLY 712103 WEST BENGAL | CHINSURAH | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance 2ND LOWEST BIDDER | |
| 3 | L3₹20.5 L+₹1.0 L (5.35%)Rejected-Finance SADARPARA P O PURULIA P S PURULIA TOWN DIST PURULIA PIN 723101 | PURULIA | PURULIA | WEST BENGAL | 723101 | L3 | Rejected-Finance 3RD LOWEST BIDDER | |
| 4 | L4₹22.5 L+₹3.0 L (15.4%)Rejected-Finance SADAR PARA PS PURULIA T DIST PURULIA PIN 723101 W B | PURULIA | PURULIA | WEST BENGAL | 723101 | L4 | Rejected-Finance 4TH LOWEST BIDDER | |
| 5 | L5₹23.6 L+₹4.1 L (21.1%)Rejected-Finance VILL ABASH CHOTO BARDIA GRAM ABASH P S KOTWALI ABASH 721102 | MEDINIPUR WEST | WEST BENGAL | 721102 | L5 | Rejected-Finance 5TH LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹43,805
Closing Date
26 Dec 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, SWEC, PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of New S.D.O. Office Building (Gplus2) and SDO Bungalow (Gplus1) including allied works at Manbazar in the District of Purulia ---- External Electrical Installation with allied works .
2023_WBPWD_610274_1
WBPWD/SE/SWEC/NIQ62/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹43,805
O/O of SE, SWEC,PWD, PWD Compound, Midnapur
7 Jul 2025
4 Dec 2023
28 Dec 2023
4 Dec 2023
26 Dec 2023
7 Dec 2023
6 Dec 2023
Amount
Supply,Installation,Testing & commissioning of cubical type panel,compartmentalized floor mounted,indoor type dust and vermin proof powder coated panel panel board ,suitable for 415V 3phase ,4wire ,50HZ ,ac supply of suitable size made out of 2mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 415A capacity ,detachable gland plate,with suitable size 4mm thick MS channel frame at the bottom,with adequate size 25 sqmm ,50 sqmm cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required .
INCOMING: 1) 200A Rating 415V, open execution type on load changeover switch .....1No.(L&T/Siemens / ABB ) 2) 200A rating 415V,TPN SFU with HRC fuse.......1No.(L&T/Siemens / ABB )
Bus-Bar: 3) 315A, 415V; 4bar copper busbar [4 x 40 mm x 5mm]- 0.8mtr length with heat shirnk PVC colour tube insulated with DMC bus support ………01 Set
OUTGOING 1)160A,415V, TPN SFU with HRC Fuse ..........01 nos.(L&T/Siemens / ABB ) 2) 125A rating 415V,TPN SFU with HRC fuse....03Nos.(L&T/Siemens / ABB ) 3) 32A rating 415V,TPN SFU with HRC fuse....03Nos.(L&T/Siemens / ABB ) 4) 32A rating 240V,DP SFU with HRC fuse....01No.(L&T/Siemens / ABB )
Supply,Installation,Testing & commissioning of cubical type panel,compartmentalized floor mounted,indoor type dust and vermin proof powder coated panel panel board ,suitable for 415V 3phase ,4wire ,50HZ ,ac supply of suitable size made out of 2mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 600A capacity ,detachable gland plate,with suitable size 4mm thick MS channel frame at the bottom,with adequate size 25 sqmm ,50 sqmm cu wire ,copper bar ,cu link cable connector etc along with necy nuts,bolts,clamps,grounting bolts incl providing and fixing the following accessoried etc complete as required.
INCOMING 1)315/320A rating 415V,TPN SFU with HRC fuse.......1No. (L&T/Siemens / ABB )
Bus-Bar: 3) 415A, 415V; 4bar copper busbar [4 x 50 mm x 5mm]- 0.8 mtr length with heat shirnk PVC colour tube insulated with DMC bus support ………01 Set
OUTGOING 1)250A rating 415V,TPN SFU with HRC fuse....01Nos.(L&T/Siemens / ABB ) 2)200A rating 415V,TPN SFU with HRC fuse....02Nos.((L&T/Siemens / ABB ) 3)125A rating 415V,TPN SFU with HRC fuse....03Nos.(L&T/Siemens / ABB )
EI WORK FOR SITC OF AC MACHINES
S&F AC machine timer for one no. machine febricated with double door 8Way SPNDB as per L&T Cat no-LTSDO8N) i) 240 V, 32A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no ii) 22A TP power contactor with 220 coil voltage (L&T, Cat no-MNX22-2P, CS90238)-1 No. iii) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module PVC Modular type switch board with top cover plate flushed on wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module PVC Modular type switch board with 4 Module top cover plate flushed on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
COMPOND LIGHT
Supply of 09 mtr long ST pole (Model-410 SP-25).Overall length 09 mtrs & planting depth 1.5 mtrs.Length of section bottom-5 mtr,middle-2 mtr and top 2 mtr long out side thickness of section bottom 11 4. 3x3 .6 5 mm,middle-88 .9x 3. 25 mm and top 76 .1x 3. 25 mm with base plate as per direction of EIC.Approx weight of pole-78 Kg. (Make : -Calcutta Pole/Bansal / Jindal/ Subham)
Supply of 12 mtr long ST pole (Model-410 SP-58).Overall length 12 mtrs & planting depth 2 mtrs.Length of section bottom-5.80mtr,middle-3.10 mtr and top 3.10 mtr long out side thickness of section bottom 16 5. 1x4 .5 0 mm,middle-13 9. 7x4 .5 0 mm and top 11 4. 3x3 .6 5 mm with base plate as per direction of EIC.Approx weight of pole-186 Kg. (Make : -Calcutta Pole/Bansal / Jindal/ Subham)
S& F of cicular type Ms structure ( 2.5 feet dia) made of 40mm dia GI pipe and 4 nos. support with 40x5 mm Ms flat including painting with necy holes , nuts,bolts etc to be fixed with pole cap to be fixed on pole top for fixing LED flood lights
S&F single arm of 1.5mtr long GI pipe of 40mm dia with 1ft long upto 4'' dia sleeve necey painting,holes,nut.bolt,washer etc.[NS]
Supply and Fixing of 60 W LED Street light luminaries (Make-Crompton, Cat No. TRP-409-60-57-SL-GL-NSG) or equivalent make of Phillips/ Havells/Bajaj with all accessories
Supply and Fixing 40W LED Post Top Luminaires (Make- Crompton, Cat no.LPTO-40-CDL-M or equivalent make of Phillips/ Havells / Bajaj complete with all accessories.
Erection of Single Steel tubular pole of length up to 9 mtr with sole plate etc. in CC foundation (Proportion 4:2:1 and dimension 0.6x0.6x1.7 mtr) having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts[H-1/1.(a)]
Above 9.0 mtr. Size 0.6x0.6x1.91 mts[H-1/1.(b)]
S&F 32 mm dia 3 mm thick polythene pipe from loop box to fitting at the time casting work of muffing as per GS.
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (Upto 9.0 mtr. long pole)
(i) One coat of red lead/Zinc chromate priming
(ii) 1st coat of synthetic enamel paint over the primer
(iii) 2nd coat of synthetic enamel paint over the 1st coat
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (above 9.0 mtr. long pole)
(i) One coat of red lead/Zinc chromate priming
(ii) 1st coat of synthetic enamel paint over the primer
(iii) 2nd coat of synthetic enamel paint over the 1st coat
Painting of muffing with double coat of paint as per direction of EIC.
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level ,neatly cemented (3 mm thick)at the base pole(In lieu of CCmuffing) suitable for alkathene/polythene pipe as directed for street light wiring . Without loop box
Supply and Fixing LED flood light (150W)made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection.System efficiency min 110/LPW 10KV SPD included.(Crompton-TFS-507-150-57-60D-SL-GL-NSG. or equivalent make of Philips/Havells/Bajaj)
Supply and Fixing LED flood light (100W)made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection.System efficiency min 110/LPW 10KV SPD included.(Crompton-TFS-504-100-30-60D-SL-GL-NSG.or equivalent make of Philips/Havells/Bajaj)
Supply of 2/4 core 1.1KV grade PVC/XLPE insulated armoured with aluminium conductor of following sizes (Make- Gloster/Havells/Polycab/KEI/RR)
2 core 10sq mm
4core 16 sqmm. [ From main source to out door kiosk]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 core 10sq mm [F-4/7(a)]
4core 16 sqmm [F-4/7(c)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
2 core 10sq mm[F-5/8(b)(ii)]
4 Core 16 Sqmm [F-5/8(b)(xii)]
Supplying & fixing 25mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
Supplying & Fixing GI waterproof type looping cable box size200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, onecompression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top coverwith brass machine screws etc., earthing terminal with lug, onsteel tubular pole near base, including S&F 40x6 mm thick, MSclamps with bolts, nuts etc. including painting with anticorrosive paint
S & Installation of a outdoor type stand mounted Distribution Junction box having size 600(H) X450(W) X250(D)mm made of 5mm thick CRCA sheet & 3mm thick top rain canopy by proper welded at all edges fixed on 50X50X6mm angle iron frame with hinged & gasketted acess door both (Back & front) two part type.The door has been double handle with necy two nos locking arrangements.it has also been separated into two parts by S& F Hilamp sheet of (10mmThick)inside middle of pillar box(Maintaining 2" gap for all side) .The pillar box has been four legs of 3 ft long of MS angle(50x50x6mm),Provision for proper ventilation system (2 nos in each side ). the FP box will be painted by two coats of synthetic enamel aluminium paint (both inside & out side)over R.O primer after preparation the MS surface . The FP box will be installed by grouting the legs with sole plate below 2ft the ground level & 1ft aboveground level by CC mixture incl necy brick work. Both below & above ground level with net cement plastering at four side of the muffing incl cutting soil & mendinding good the damages . JB must contain the following electrical accessories:- i)- FP box consisting 200A capacity 5 nos Al Bus bar(Size-1.5ft(L) X 2"(W)X 6mm(T) with minimum 8 nos hole with necy nut bolt washers,porcelin chair ,Dim Rail channel ( 1.5Ft long)-01 no,etc as required iii)-S & F SP MCB of 63A-6 nos( M-Havells/Legrand,C curve,10 KA iv)-S & F TPN SFU,3nos DIN Type fuse rating , All the necy connection inside pillar box will be complete by minimum 10-16 Sqmm single core multistranded copper wire(approved make) with necy socketing
S&F 32A ML1 3ph contactor(Make-L&T)
S&F Astronomical Timer switch (Make-L&T-T2DDT7)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pip(G1/2)
EI WORK FOR SITC OF DG SET
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode (for soft soil / morrum soil) for 2 no Genarator Neutral earthing . the distance between two earthing should be twice of electrode length.(For DG Earthing)
Supplying & fixing Extra copper strip 25 mm x 6 mm from Copper earth electrode to Neutral point with required nos of nuts ,bolt washer for 125KVA DG for proper earthing of DG.
Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. By ISI-Midium G.I Pipe
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply & delivery of XLPE/A Al cable of following size with 2 nos 10 SWG GI wire as ECC.(Make- Havells/Polycab/KEI/Gloster /RR Kabel) as per choice of EIC. 4Core 150 Sqmm
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4Core 150 Sqmm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4Core 150 Sqmm.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 65 mm dia
D. D. ENTERPRISE
SAIBAL SARKAR
RAHUL TRADERS
SREE LALJI
MOON LIGHT HOUSE
technical_1306421.pdf
PDF • 0.47 MB
techsummary_1306421.pdf
PDF • 1.02 MB
finance_1306421.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_1306421.pdf
PDF • 0.52 MB
AOC62.pdf
PDF • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .