Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹6.5 LAccepted-AOC | l1 | Accepted-AOC l1 | |
| 2 | l2₹7.2 L+₹63,486.75 (9.71%)Rejected-AOC | l2 | Rejected-AOC l2 |
Tender Value
₹8.2 L
EMD Value
₹20,527
Closing Date
9 Aug 2018, 5:00 pmClosed
Assistant Engineer,LSGD Section
Office of the Assistant Engineer,Poovachal GP, Thiruvananthapuram - 695575
PULIMOODU ANAMUGHAM GRALIKUZHI ROAD SIDE WALL/CULVERT CONSTRUCTION IN WARD 21(83/18-19)
2018_LSGD_221355_1
38/AE/LSGD/PVL/2018-19
Open Tender
Civil Works - Roads
Item Rate
120 days
PULIMOODU ANAMUGHAM GRALIKUZHI ROAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,904
Yes
online
₹20,527
Yes
27 Nov 2020
28 Jul 2018
14 Aug 2018
28 Jul 2018
9 Aug 2018
28 Jul 2018
28 Jul 2018 - 9 Aug 2018
Amount
SIDE WALL
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
od135573/2018_2019 : Dismantling DR Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 50m as per Technical Specification Clause 202.<br>(D)Dry Rubble Masonry
od80973/2018_2019 : Modified 8.7.2 Rubble dry stone masonry for foundation and superstructure
od135620/2018_2019 : Random rubble dry stone masonry using department rubble (MoRD)
od80974/2018_2019 : RR in Cement mortar 1:6III. Random rubble masonry (iii)In cement mortar (1:6)
12.3 : Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
10.3.A.3 : Direction and Place Identification signs upto 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>(iii) Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on RCC Post 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
od121453/2018_2019 : GI pipe name board<br>Supplying and fixing information board 75cmx60cm using GI pipe and M.S sheet including all charges etc. complete.
CULVERT
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
11.2.1 : Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9I. Sand filling
od121456/2018_2019 : *WITHOUT FORMWORK-MOD(11.4.1.1) CEMENT 250KG/M3<br>Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203r/n<br><br>I.P.C.C grade M 10<br><br>(i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
14.8 : Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
od121460/2018_2019 : * 1;2:4 USING 20MM- WITH OUT FORM WORK-320 KG CEMENT CONTENT( MOD 11.4.4)Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
C RAJASEKHARAN NAIR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_292048.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .