GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2021_MES_479364_1
GE (ARMY) TVM 9412/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹10,240
Yes
3 Nov 2021
4 Oct 2021
3 Nov 2021
4 Oct 2021
1 Nov 2021
18 Oct 2021
5 Oct 2021 - 16 Oct 2021
Amount
Draining out used lub oil from the DG set engine cleaning of chamber and supply and filling of new multigrade engine oil for the DG sets of various capacities installed under GE (Army) Trivandrum all as specified and directed. NOTE: Flushing out sludge accumulated in the oil chamber to be done properly before filling the new oil. Make: Cat No. 82.050.10.0.20 of Koel care super genuine oil
M&L for carrying out scheduled maintenance service of the DG sets of 160 KVA through manufacturer service engineer complete including replacement of elements of fuel filters, engine oil filters and air filter with gaskets checking the engine for any leakages adjusting engine belt tension topping up radiater coolent etc complete all as directed by Engr-in-Charge. NOTE: Engine oil/coolent required for servicing the DG set will be measured and paid seperatly under relenvant items of the schedule.
All as per ser item No. 2 above but for DG set of capacity 62.5 KVA
All as per ser item No. 2 above but for DG set of capacity 40 KVA
All as per ser item No. 2 above but for DG set of capacity 30 KVA
All as per ser item No. 2 above but for DG set of capacity 25 KVA
All as per ser item No. 2 above but for DG set of capacity 20 KVA
M&L for repair/servicing of self starter including replacement of solenoid switch, rewinding of armature, carbon brush set, carbon brush holder and taping of field coil for the DG set of capacity 160 KVA all as specified and directed.
All as per ser item No. 8 above but for DG set of capacity 20 KVA
M&L servicing/repair of charging alternator including replacement of diode, bush/bearing and varnishing of windings for DG set of capacity 160 KVA all as specified and directed.
All as per ser item No. 10 above but for DG set of capacity 25 KVA
M&L for repair and calibration of fuel pump and injectors as per calibration procedure and norms including replacement of pump element, injector nozzles and O rings/washers etc for DG set of capacity 40 KVA all as specified and directed.
All as per ser item No. 12 above but for DG set of capacity 30 KVA
S&F in replacement indicator lamp LED type complete assembly with holder suitable for 28 mm dia hole all as specified and directed.
Taking out existing U/S V belts (Poly V-belt) of 40 KVA DG set and S&F Poly V-belt of same size complete all as specified and directed Make: Cat No. 4H.1493.01.0.00 (HSN Code-40103999) of Kirloskar
Taking out existing U/S V belts of size XPA 1250 Cogged of 25 KVA DG set and S&F V-belt of same size complete all as specified and directed Make: Cat No. 4H.069.01.0.00 (HSN Code-40103290) of Kirloskar
Taking out existing U/S V belts of size B-47 1237 length of 20 KVA DG set and S&F V-belt of same size complete all as specified and directed Make: Cat No. 38.066.01.0.00 (HSN Code-40103999) of Kirloskar
S&F in replacement automatic voltage regulator (AVR) suitable for 160 KVA, 30 KVA & 20 KVA DG set including taking down the old UNSV one complete all as specified and directed. Make: Cat No. 2H.811.32.0.00 (HSN Code-85030090) of Kirlosker Green (Model: TAVR-10)
S&F in replacement 3 phase voltmeter 0-500 volts 96mm square flush mounting digital type all as specified and directed Make: L&T/AE/MECO or equivalent
S&F in replacement digital type, 3 phase ammeter 0-100/200/300/400 Amps CT operated with 96x96 mm square flush mounting type all as specified and directed Make: L&T/AE/MECO or equivalent make
S&F in replacement CT coil 400/300/200/100/5 amps all as specified and directed. Make: AE/KAPPA/legrand/Schneider Electric or equivalent make
S&F in replacement of MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz having adjustable thermal setting range 70% to 100% and fixed magnetic setting (Ics = 100% Icu) with SS enclousure and breaking capacity 16 KA conforming to IS/IEC 60947-2 & IEC 60947-2 including dismantling of old unsv one and making incoming and outgoing connections to the new one complete all as specified and directed Make: Cat No. N2063D4P of Indoasian or equivalent in L&T/Havells/HPL/Legrant/Crompton Greaves
All as per ser item No. 26 above but for 100 Amps with 16 KA breaking capacity Make: Cat No. N2100S4P of Indoasian or equivalent in L&T/Havells/HPL/Legrant/Crompton Greaves
Draining out completely radiator coolant of different capacity of DG sets by loosen drain plug and then tighten the drain plug, slowly feed coolant of superior grade into the radiator through the filler until radiator is full, squeeze the upper radiator hose 2/3 times after coolant reaches the filler neck, close the radiator cap, testing after refilling complete. NOTE: Use LEYPOWER Coolant 5000 pre mixed coolant. No need to add water. Make: Castrol/Servo
M&L for preparation of painted surfaces of the acquistic enclosure/DG sets of capacity 160 KVA DG set by scraping and removing rust and other objects and applying two coats of synthetic enamel paint of existing colour by spray painting over a coat of zinc chrome primer and marking SM/MES Nos and repairing and greasing door hinges and locks all as specified and directed.
All as per ser item No. 27 above but for DG set of capacity 40 KVA
All as per ser item No. 27 above but for DG set of capacity 30 KVA
All as per ser item No. 27 above but for DG set of capacity 25 KVA
All as per ser item No. 27 above but for DG set of capacity 20 KVA
Supply and fix in repair turbo charger and removing old detoriated parts, by replacing new for smooth functioning of DG set capacity 160 KVA
All as per ser item No. 32 above but for DG set of capacity 40 KVA
All as per ser item No. 32 above but for DG set of capacity 25 KVA
All as per ser item No. 32 above but for DG set of capacity 20 KVA
Dismantling the fuel/diesel tank, clean the inside surface and strainer, removing old detoriated parts of pipe line from deisel tank to fuel filter, replacing new fuel flow line for smooth functioning, refixing the fuel tank complete all as directed for DG set capacity 160 KVA
All as per ser item No. 36 above but for DG set of capacity 62.5 KVA
All as per ser item No. 36 above but for DG set of capacity 40 KVA
All as per ser item No. 36 above but for DG set of capacity 30 KVA
All as per ser item No. 36 above but for DG set of capacity 25 KVA
All as per ser item No. 36 above but for DG set of capacity 20 KVA
Material and labour for radiator cleaning after removing carefully the radiater assembly from the DG set and cleaning, brazing wherever required from the site and re assembling completely of DG set capacity 160 KVA
All as per ser item No. 42 above but for DG set of capacity 62.5 KVA
All as per ser item No. 42 above but for DG set of capacity 40 KVA
All as per ser item No. 42 above but for DG set of capacity 25 KVA
All as per ser item No. 42 above but for DG set of capacity 20 KVA
Dismantling of all unserviceable electric wiring loom from the 20/25/30/40/62.5/160 KVA DG Set of any make connected between starting switch, self starter, dynamo and other sensing points and supply and fixing the new electric wiring loom as per existing with protected flexible conduit complete in all respect and testing for proper function of DG Set complete all as specified and directed
Material and labour for overhauling of alternator by heating and varnishing rotor and stator assembly for getting proper IR value and reasseble the same of DG set capacity 40 KVA.
All as per ser item No. 48 above but for DG set of capacity 25 KVA
Supply & spread loose filling with river sand inside the FOL store, cable duct in DG set room etc not exceeding 150mm thick layer including removing the old sand to a distance not exceeding 50 mtr from the starting point complete all as directed
M&L for Earthing complete in replacement with copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earth lead of copper strip of size 20mm x 3mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia from earth plate to Panel and DG set and water pipe 20mm dia GI medium grade raised upto a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with two handles, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance not of MES Schedule Part-I of SSR-2009 exceeding 50 mtr testing complete all as shown in electrical plate No-3 including removing old one from site of work complete all as specified and directed. NOTE: (a) Earthing shall be provided as per IS:3043-1987. (b) Earthing shall be carried out 7.5 mtr apart from the building. (c) Rate for copper strip upto test point included in the quoted rate.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required 20 x 3mm copper strip including removing the old unserviceable one complete all as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m laid infront of LT panel & DG set complete all as specified and directed by Engr-in-Charge.
Dismantling the old/detoriated battery terminal cables, supply and fixing new appropriate size battery terminal cable including hose clips, apply petroleum jelly on battery terminals, tighten the terminals and testing complete all as directed
Supply and install in replacement of on load change over switch 415 volt AC, 50Hz in sheet steel enclosure, 4 pole of capacity 63 Amps, confirming to IEC-947-3 staggered terminals, site convertible fuse version, interchangeable dual shaft position with site convertibility, to be provided into existing panel including dismantling of old unsv one and making electrical connections new one complete all as specified and directed by Engr-in-Charge. Make: Cat No. ITAS0063 of Indoasian or equivalent make of L&T/Legrand/Havells
SUPER COOL
S L ELECTRICAL WORKS
JEETH CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .