| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC M S VIJAYA VINAYAKA INFRA DOOR NO 39 33 62 1 4 PLOT NO MIG 95 96 SAMYAM ENCLAVE FLAT NO 101 VUDA COLONY MADHAVADHARA MARRIPALEM VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | ₹3.7 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹3.8 Cr+₹17.0 L (4.63%)Rejected-Finance | ₹3.8 Cr+₹17.0 L (4.63%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹3.9 Cr+₹24.4 L (6.63%)Rejected-Finance | ₹3.9 Cr+₹24.4 L (6.63%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹4.0 Cr+₹29.0 L (7.88%)Rejected-Finance | ₹4.0 Cr+₹29.0 L (7.88%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹4.0 Cr+₹33.0 L (8.98%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹4.0 Cr+₹33.0 L (8.98%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹4.1 Cr
EMD Value
₹4.9 L
Closing Date
29 Jun 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO BUILDING NO. P-143 AT INS DEGA, VISAKHAPATNAM
2022_MES_526960_1
82257 / E8
Open Tender
Civil Works
Item Rate
365 days
Visakhapatnam
Class A
Category a i
10 documents required · 10 mandatory
₹2,000
Garrison Engineer Naval Depot
₹4.9 L
Yes
16 Jul 2022
30 May 2022
6 Jul 2022
30 May 2022
29 Jun 2022
22 Jun 2022
30 May 2022 - 8 Jun 2022
Amount
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Taking down Aluminium Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 4 Sq.m but not exceeding 10.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm wood grain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed with 5 mm thick X 15mm wide PVC sheet beading used inside stiles and rail and decorative PVC beading of 10mm X 10mm to the stiles & rails and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, windows shutters sliding/ openable type/ ventilator shutter Aluminium section including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc. per Door Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7.2mmx4.2mm) including Powder Coated Aluminium Channel of size 20 X 10 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
Supply only 5mm thick Sheet Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
Supply only 12mm thick, Prelaminated Particle Board, Decorative Choice Lamination on Both Sides, Medium Density, Exterior Grade complete all as specified and as directed.
M & L for Preparing surfaces of wood and wood based materials, steel and iron work new or old, of any description and girth not otherwise described, and treating ends of posts, backs of Chowkats, etc. area tarred exceeding 0.1 Sq.m and not exceeding 0.5 Sq.m each with tar or coal tar black paint complete all as specified and as directed.
M & L for Plain cement concrete Type B1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate cast in situ as in lintels up to 1.5m span, Cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Hand Rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for Balusters Running Bars, for Doors, Balusters, Nosing to Steps including embedding in concrete and screwing etc., Wind Ties for roof including securing bolts, Posts and Struts in Fencing including cutting tops to shape as directed, bending to shape, notching for wire, drilling holes or as in flat iron fillets [for securing wire mesh and barbed wire etc.] including all necessary drilling, bolting or riveting, etc. and similar work complete all as specified and directed.
Hacking out old broken glass [any thickness, size, quality or description] from wooden frames including punching or drilling out old glazing pins / spring clips complete all as specified and as directed.
S & F 6.4mm thick rough cast wired Glass in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 100mm long complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F in repairs Curtain Rails, mild steel, CP, 25 mm dia with fixing brackets, stops, rollers etc complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 450 mm X 300 mm including Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete complete all as specified and as directed.
S & F in repairs Vitreous China Urinal, Half Stall Type, Flat Back, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc., grating and union for discharge pipe, brass CP urinal spreader, CP screws etc. complete all as specified and as directed.
S & F in repairs Stainless steel kitchen sink, made of stainless steel 1 mm thick, with plugs, washers and Waste Fittings, 32 mm dia, Brass, Chromium plated, and 32mm dia PVC flexible Waste Pipe, 750 mm long including bedding in cement mortar on to dwarf wall or including fixing cantilever CI Brackets and connecting union to pipe, overall size 495mm X 420mm, bowl size 410mm X 330mm X 160mm complete all as specified and as directed.
S & F PTMT Grating Doom, 100 mm dia [Minimum weight 25 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed.
S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 10000 Litres Capacity hoisted and fixed in position including provision of 25mm bore ball brass valves, high pressure, with polythene float and flynut and 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old unserviceable existing tanks complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Demolition of Stone Slab laid, bedded and pointed in Cement Mortar of thickness not exceeding 25 mm and removing serviceable tiles to the stores and removing rubbish / debris to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
Taking down rain water pipes of any dia (any size or pattern), including all fittings complete all as specified and as directed.
S & F 160mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 160 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 75 mm bore Cast Iron Nahani /Floor Trap with grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and as directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 or 32 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 20 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F CPVC Pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F CPVC Pipes 32 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as per Jaquar Catalogue No. CON-083KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree /Prayag/ Blue Star & Silver Shine complete all as specified.
S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Prayag/ Blue Star & Silver Shine complete all as specified.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound [ISI marked] of approved make.
Demolition of Reinforced Cement Concrete as in Roof, Floors [other than ground floor], beams, staircase, landing and similar suspended work including reinforcement cut as required to facilitate demolition and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for RCC M-30, Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves, Chajjas and the like complete all as specified and as directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] for fair finished surfaces of concrete complete all as specified and directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for 50 mm thick PCC 1:2:4, Type B-1 using 20mm graded aggregate as in flooring, surface finished fair and even complete all as specified and as directed.
M & L for Pavement quality controlled concrete of flexural strength not less than 40 Kg/Sqcm in field using not less than 400 Kg cement / Cum as in pavements / slabs / floors etc. laid in single layer to required thickness including necessary formwork, compacting, finished even and smooth and brooming complete all as specified and as directed.
M &L for 400 micron thick polythene film (vergin quality) as per IS 2508 of weight 390Gm/sqm antifriction layer on the base course complete as per specification with specified overlap between adjacent strip and transverse joint etc complete all as per specified and directed.
M&L for carrying out following repairs to existing PCC floor all as specified and as directed (a) Racking out existing sealant from joints to a depth of at least 30 mm, cleaning the grooves joints, edges up to a depth of at least 15 mm by scrapping/ grinding by mechanical means to expose the concrete surfaces. (b) M&L for pressure grouting , drilling holes 12 mm dia at distance not exc 500 mm upto a depth of at least 250 mm using drilling machine fixing nozles and injecting neat cement slurry admixture with Sika Intraplast N 200 @ 225 gms per bags of 50 kg cement or equivalent and Removal of Grouting nozzoles, cleaning the groove joints without any dust, oil etc complete all as per manufacture instruction. (c) Supply and inseting 12 mm thick compressed nylon expansion joint board into the groove, over that inserting 12 mm dia closed cell baker rod maintaining uniform depth & supply and application by filling the joint with PU sealant- SIKA Hyfiex or equivalent.
M & L for levelling the floor surfaces, grinding surface without any dust, oils, laurance, cement mortar etc. and application of three component epoxy mortar Sika 41 or equivalent makes as specified in list of makes, certain required places of the floor joints to get a required finish complete all as per manufacturer instructions, as specified and as directed.
M & L for providing flow applied epoxy resin based flooring of 5mm total thickness with 3mm thick high strengh self smoothing under lay with three compound system comprising of epoxy resin base, resin hardner & filler (Nito Flor EU5 of M/s. Fosroc or equivalent approved make as specified here in after and floor topping with flow applied epoxy resin 2 mm thick (Nito Flor SL2000 of M/s. Fosroc or equivalent approved make as specified here in after) over a coat of solvent based Epoxy Resin Primer designed for maximum absorption and adhesion to concrete substrates on existing floor by using stiff brushes and/or rollers for primer and serrated trowels and spiked nylon rollers for finishing coat including preparation of existing flooring by cut opening all construction joints to a width of 15mm and to required depth, cut open all Anchor Grooves along floor topping termination points and alround the columns, all cracks in the floor concrete including all other joints to a size of not less than 10mm X 10mm, preparing the surface of concrete substrate with scarification or by suitable mechanical means and cleaning the surface with industrial vaccume cleaner to remove all foreign matter, dust and debris etc. including filling the cut open grooves with same material, finishing the surface to even and plain surface using suitable means to remove all imperfections, trowel marks and entrapped air complete all as specified as directed and as per manufacturer’s instructions. Note: The work shall be executed by the Authorised Applicator of the Manufacturer under the guidance of Manufacturer of Epoxy Flooring. Make: M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. BASF India Ltd or M/s. Asian paints Limited.
Dismantling of Plain or Corrugated Steel sheeting of any gauge, thickness of roof in roof coverings, complete all as specified and as directed.
S & F pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile and thickness not less than 0.70mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
S & F pre-painted Galvalume steel Plain Sheets and thickness not less than 0.70mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter / down spouts and top rafters etc. complete all as specified.
Fixing only serviceable plain/ corrugated steel sheets obtained from dismantling with coach screws and washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter / down spouts and top rafters etc. complete all as specified.
S & F plain Aluminium Sheet Alloy 31000 H4 in Ridges, Hips, Valley Gutter, drip and straight flashing of not less than 0.71 mm thick complete all as specified and as directed.
S & F Translucent Acrylic Sheet of 2 mm thick [Plain or Corrugated] fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering / wall cladding complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
Dismantling of Mild Steel or Wrought Iron Work of any description not otherwise provided for complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Stairs [Framed] including Stringers, Treads, Landing, Balusters, Hand Rails etc including cleats, brackets, etc complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [plain & chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment including fixed with Nut and Bolt / welding complete all as specified and as directed.
M & L for Welded steel wire fabric of weight not exceeding 4 Kg per Sq.m fixed to steel or wooden members with suitable fixtures complete all as specified and as directed.
Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
S & F in repairs False Ceiling Frame Work using Anodised Aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium "T" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 4 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position including fixing 16mm thick Mineral Fibre Board of size 600 X 600 X 16mm of make Armstrong [Model No. DUNE RH99 or equivalent approved makes as specified here in after], Premium sand textured finish, having humidity resistance of RH99 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified.
S & F in repairs Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for one coat of white wash on old decorated surfaces of walls, Pillasters etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for one coat of white wash on old decorated surfaces of ceiling etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over one coat of exterior primer over two or more coats of Cement based Wall Care Putty on newly plastered walls, pillasters, bands, borders, soffits of chajjas and projections including rubbing with sand paper to obtain a smooth surface including necessary preparation of surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls, pillasters, bands, borders, soffits of chajjas and projections including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over one coat of exterior primer on wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered Wall surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on wall surfaces complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for one coat of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for one coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for preparation of existing exposed steel surfaces free from dust, loose material, surface contamination, rust, scale, mortar, concrete, other loose and deleterious materials, damaged and deteriorated concrete by blast cleaning or other means of mechanical abrasion or suitable means and applying two coats of Solvent Based Anti Corrosive Paint over one coat of Red Oxide / Zinc Chrome Primer on old steel surfaces over 10cm width or girth complete all as specified and as directed.
Demolition and breaking up drain pipes [Salt glazed ware, AC or Reinforced concrete] of any diameter set in cement mortar complete all as specified and as directed.
M & L for 150 mm dia RCC Pipes, Class NP3, laid and jointed with collars laid in trenches and jointed with cement mortar complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
S & F Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 304, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars, Wall Lining [Veneering to Wall] etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Skirting / Dado / Risers and joints shall match with the flooring.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
Excavation over areas not exceeding 1.50 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Removal of excavated material [Soil] to a distance exceeding 250m But not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Crushed Stone Sand / M-Sand filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
M & L for 285 gsm non wooven geo textile cloth and placing in position complete all as specified and as directed.
M&L for Moorum/red bajri filling in foundations, floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled and consolidated complete all as specified.
M & L for 100 mm thick, PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in sub base, surface finished fair and even complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings [exclusive of steel sheeting or other covering, running rails and guides] and hanging, also fastening and fixing complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [plain & chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment including fixed with Nut and Bolt / welding complete all as specified and as directed.
S & F MS rolled / wheels specially designed to run on bottom track wheels with sealed ball bearing suitable hangar door of make SKF or equivalent approved makes and self lubricating type duly bolted to the door frames complete all as specified and as directed. Note: The roller/ Wheels supplied shall be weighed at site & considered for payment.
S & F MS rolled / wheels specially designed to run on top track wheels with sealed ball bearing suitable for hangar door of make SKF or equivalent approved makes and self lubricating type duly bolted to the door frames complete all as specified and as directed. Note: The roller/ Wheels supplied shall be weighed at site & considered for payment.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
Taking down carefully submain wiring of any description and size complete including wooden battens / conduits / casing capping and making good the disturbed surfaces all as per existing complete all as specified and as directed.
Taking down MCCB DBs, MCB DBs, SPN / TPN Enclosures including MCCBs, MCBs etc of any description and any capacity and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type antibacterial Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point / One 3 Pin Switch Socket Outlet 5 Amps on Independent Board controlled by One Switch complete all as specified.
All as per Serial Item No. 127 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 127 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified.
All as per Serial Item No. 127 above but one AC / Water Cooler / Geyser point on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including stove enameled steel conduit of 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type antibacterial Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point / One 3 Pin Switch Socket Outlet 5 Amps on Independent Board controlled by One Switch complete all as specified.
S & F Switch Flame Proof rotary type with Termination Box in LM6, upto 16A, Single Pole, 240 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, 5 Amps, 230 Volts, one way complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 2/3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps cum 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
Taking down Light Fittings of any description, any type and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and minor repairs complete all as specified and as directed.
S & F in repair Energy efficient LED High Bay Light fitting, of not less than 12000 Lumens (120 Watts) output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Square recessed mounted Flat Panel LED Light suitable for fixing in 2' X 2' Grid False Ceiling of not less than 3600 Lumens (36 Watts) warm/cool day light output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens (20 Watts) warm/cool day light output, 5700 K, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Integral LED Aviation Light of Make & Cat No. BGAV 302 LED of M/s. Bajaj or equivalent approved makes, comprising of aluminium housing with polycarbonate enclosure including standard fixing arrangements and connecting up complete all as specified and as approved. Note: Light fitting shall be of PF>0.95
S & F MCCB DB, VTPN, 8 Way, 415 Volts with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for 200 Amps, 4P, 25KA MCCB as incomer complete all as specified and as directed. Note: Unit rate quoted shall be deemed to include for cost of 01 No. of MCCB of capacity 250Amps, 4 pole.
S & F MCB DB, TPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SPN, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 40-63 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capcitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for repairs to Ceiling Fan of any description including Rewinding of Motor using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. complete all as specified and directed.
Taking down Exhaust Fan / Air Circulator/ wall mounted/pedestal fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 /6 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for repairs to Exhaust Fan upto 450mm sweep of any description including Rewinding of Motor using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. complete all as specified and directed.
M & L for repairs to Air Circulator / wall mounted/pedestal fan upto 600 sweep of any description including Rewinding of Motor using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. complete all as specified and directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
Taking down Split/ Windows Air Conditioner of any capacity including Outdoor unit of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up, cleaning, restoring the refregerant gas and sealing the copper pipe line, carrying out minor repairs and replacement of Nuts & Bolts etc. complete all as specified and directed. Note: (i) It is the responsibility of the contractor to keep the AC units in safe custody till refixing of the same. (ii) Any damages to existing AC units done during taking down/ refixing process has to be borne by the contractor without any extra cost to the department.
Supplying, laying and testing XLPE insulated, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Supplying, laying and testing XLPE insulated, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Supplying, laying and testing XLPE insulated, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
Supplying, laying and testing XLPE insulated, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed.
S & F in repairs TP & N Enclosure with 3 Pole and Earth Metal Plug & Socket for incorporating TP MCB complete including One MCB, TP, 63 Amps, 415 Volts complete all as specified and as directed.
Labour for taking down of existing cable of sizes 300/185/120/95/70 Sqmm during repair works, disconnecting from main supply line and relaying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in ducts complete all as specified and as directed.
Taking down Fire Alarm Control panel alongwith its accessories like manual call points, detectors/ sensors/ hooters, fire alarm etc. from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up, cleaning, testing, carrying out minor repairs and replacement of accessories etc. complete all as specified and directed. Note: (i) It is the responsibility of the contractor to keep the Fire Alarm Control panel alongwith its accessories in safe custody till refixing of the same. (ii) Any damages to existing Fire Alarm Control panel alongwith its accessories done during taking down/ refixing process has to be borne by the contractor without any extra cost to the department.
M & L for Dismantling motors of 7.5 HP capacity from motorised hanger door /Rolling Shutters and rewinding with the same super enamelled copper winding wire of superior quality and same gauge of with proper insulation with lethroid paper, sleeves, varnishing with golden colour varnish , greasing the bearings, replacement of worn out nuts, bolts, washers split pins including reparing and overhauling of gear box assembly by metal filling, cutting and other machining process on lathe machine, replacement of suitable bearings, chain link sprocket with mounting shaft and refixing with proper alignment with Gear Boxes etc. testing on completion, complete all as specified and as directed. Note: Unit rate quoted shall be deemed to include for cost of removal of exisiting copper cable of any size from starter panel to shutter motor and relaying the same after completion of necessary B/R and E/M repair work or as directed by Engineer-in-Charge.
M & L for replacement of DOL starter 5 HP/3KW, 3 Phase suitable for rolling shutter two way revolving type (clockwise and anti clockwise) complete all as specified and as directed.
S & F in repair PVC insulated,FR, round sheathed Multistranded Flexible Copper Conductor Cable of size 4 Sq.mm 4 core, ISI marked, 1100 Volt Grade complete all as specified and as directed.
Earthing complete with Copper Plate Electrode 600 X 600 X 3 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 20 X 3mm copper Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of Copper Strip of size 20 X 3mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 25 X 4mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3.15 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
S & F in repairs GI Perforated Cable Tray of Size 100mm wide, 50mm Deep with GI cover, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. complete all as specified and as directed.
S & F in repairs GI Perforated Cable Tray of Size 50mm wide, 50mm Deep with GI cover, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. complete all as specified and as directed.
Taking down existing cable tray and refixing with necessary Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. including one coat of synthetic enemal painting complete all as specified and as directed.
Ruchira Associates
CIVILEC ENGINEERING WORKS
TECHNO SOFT SOLUTIONS
S A R CONSTRUCTIONS
Mahamaruti Constructions
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .