| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC being L1 Bidder |
| 2 | L2₹1.3 Cr+₹8.8 L (7.27%)Rejected-Finance | ₹1.3 Cr+₹8.8 L (7.27%) | L2 | Rejected-Finance Other than lowest Bidder |
| 3 | L3₹1.3 Cr+₹10.7 L (8.83%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹1.3 Cr+₹10.7 L (8.83%) | L3 | Rejected-Finance Other than lowest Bidder |
| 4 | L4₹1.3 Cr+₹11.9 L (9.89%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.3 Cr+₹11.9 L (9.89%) | L4 | Rejected-Finance Other than lowest Bidder |
| 5 | L5₹1.3 Cr+₹12.1 L (10.0%)Rejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹1.3 Cr+₹12.1 L (10.0%) | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
18 Feb 2020, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI
SPL REPAIRS TO BLDG NO 2 J 27 P 15 AND REPLACEMENT OF HT ELECT EQPT INCL HT CABLE AND ALLIED WK ON SUB STN NO 21 02 13 26 1A EMEWKSP 14 15 UNDER GE N BINNAGURI
2020_MES_317667_1
8010/BIN(N)/242019-20
Open Tender
Civil Works
Item Rate
150 days
BINNAGURI MIL CANTONMENT
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹1,000
GE NORTH BINNAGURI
₹1.9 L
Yes
14 Mar 2020
23 Jan 2020
19 Feb 2020
23 Jan 2020
18 Feb 2020
13 Feb 2020
Amount
Schedule 'A'
Dismantling of asbestos cement ( corrugated, semi corrugated etc ) sheets of any gauge or thickness as in roof coverings including ridge, hip, valley etc and removing debries from site of work complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, Nainital or similar pattern roof coverings including ridges MS wind tie complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI Based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in ridge fixed with selp tapping screw complete all as specified and directed.
Fixing only plain or corrugated steel sheeting, any gauge, thickness, Nainital or similar pattern roof coverings including ridges complete all as specified and directed. (Note:- Sheet & MS wind tie obtained from item no 2.00 above)
S & F for rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc of Fe-290 Gde E-165 complete all as specified and directed.
M and L for complete removal of existing painting by scraping or by other any means to old steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation complete all as specified and as directed.
M and L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking down cement plaster on brick or concrete surfaces including raking out joints,hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for 15 mm thick plastering in cement mortar (1:6) on other than fair face of brick/concrete surface finished the surface fair and even without using extra cement on internal wall surfaces complete all specified and as directed .
M&L for 15 mm thick plastering in CM (1:4) on fair faces of brick/concrete surface in two layers (10mm + 5mm) and the top layer shall be mixed with WPC as per manufacturers instruction, finished even and fair without using extra cement on external wall surfaces (WPC will be measured and paid separately)
Supply only integral water proofing compound.(ISI marked)
M&L for three coats of white wash on newly plastered surfaces of wall including preparations complete all as specified and as directed.
M&L for applying Two coats of cement base paint over a coat of alkali resistant primer on new concrete/wall surfaces complete all as specified and as directed.
M&L for complete removal of existing treatment by scrapping or by any means to old wall surfaces and applying Two coats of cement base paint over a coat of alkali resistant primer including preparation complete all as specified and as directed.
M&L for preparing old decorated plastered or unplastered surfaces of wall incl cornices,pilastera and other wall features etc by brooming down or steel wire brushing scrapping down to remove smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spot etc and applying one coat of white wash on the wall complete all as specified and as directed.
Demolition of cement concrete in ground floor and pavings n.exc 15cm thickness (below or above ground level) including removel of debris/demolished materials to a distance exc 50m and n.exc 250 m complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate), 75mm thick in plinth protection/footpath laid in panels and surface to be finished even smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in quoted rate for concrete in plinth protection.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing debries from site of work complete all as specified and as directed
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan to any radius in half bricks built in cement motar (1:4) using old size of bricks all as directed. Note:- 2 Nos 5/6 mm dia round bar shall be provided in every fourth course of brick wall as directed by Engineer-in-Charge and the rate shall deemed to be inclusive in the unit rate.
Demolition of cement concrete(Reinforced) of any description in any position not otherwise specifically provided for and removing debries from site of work complete all as specified and as directed.
M and L for Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete complete all as specified and as directed.
M&L for RCC M-25 Design Mix as in slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and as directed.
M&L for TMT bar 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M and L for Cement concrete1:3:6 Type C-1 using 20mm graded aggregate as in surface channels and drains complete allas specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed..
M and L for 100 mm thick PCC 1:2:4 type B1 using 20mm graded aggregate in floors finished the surface fair and even without using extra cement complete all as specified and as directed.
M&L for PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in filling of sunken floors incl demolition of old and existing concrete of any description complete all as specified and as directed.
M&L for high density polyethylene pipes (HDPE) of 40mm dia of presure rating 6 Kgf/sqcm use as in spout pipe laid in trenches/floor complete all as specifed and as directed
Cutting holes into or through brick walls built, in cement mortar and making good in CM (1:3) or cement concrete 1:2:4 type B-1 as required, superfacial area exc 400Sqcm and n.exc 0.10Sqm for exhaust fan complete all as specifed and as directed
M&L for 10mm thick in cement mortar 1:4 mixed with WPC as per manufacturers instruction as in chajjas, facia etc complete all as specifed and as directed. (WPC shall be measured separately)
M&L rendering 5mm thick in CM (1:3) on fair faces of concrete surfaces as in ceilling finished fair and even without using extra cement complete all as specified and as directed
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of green complete all as specified and as directed
M&L for machine cut kota stone slab flooring 18 to 20mm thick over 15mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement screed bed in CM (1:3) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Taking up or down GI Tubing including all fittings 15mm bore pipe including cleaning for refixing or removal from site as directed.
S&F 15mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed.
Refixing old 15mm GI tubing and connections on new or old position (walls, ceilling, floor etc) with new fittings complete all as specified and as directed. (Note:- GI pipe obtained from item No 38 above)
Taking up or down GI Tubing including all fittings 20mm bore pipe including cleaning for refixing or removal from site as directed.
S&F 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed.
Refixing old 20mm GI tubing and connections on new or old position (walls, ceilling, floor etc) with new fittings complete all as specified and as directed. (Note:- GI pipe obtained from item No 41 above)
S&F in repair 15mm dia bib tap chromioum plated long body handles screwed with wall flange for iron pipe and fixed complete all as specified and as diredcted.
S&F grating doom 100 mm dia of PTMT (Min wt 25g) complete all as specified and as directed.
S&F in repairs , stop valves 15mm dia, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, but fancy type, chromium plated with long shank and cup complete all as specified and as directed..
S&F of angle stop valves 15mm dia, cast chromium plated, screwed down, high pressure, screwed both ends for iron pipe and fixed, chromium plated with long shank and cup (concealed type) complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting hases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on brick wall complete all as specified and as directed.
M&L in repairs for 100mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 and making good to floor matching with existing finishes including taking down old damaged floor trap complete all as specified and as directed.
-ditto- all as per item No 49 above but nahani trap
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm long etc complete all as specified and as directed.
S&F pillars taps fancy type, cast copper alloy with capston heads, chromium plated screwed down high pressure, screwed for iron pipe 15mm bore complete all as specified and as directed.
S&F of wash hand basin vitreous China, white, flat back (550x400mm) cutting for and pinning ends of brackets and waste coupling of PTMT for glazed ware basin etc with long screwed shanks and fly nuts,full threaded flage end bedded in white cement incl PVC waste pipe with CP/PTMT coupling for required length complete all as specified and as directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F in repairs gun metal, globe or gate valve with iron wheel head, screwed both ends for 20mm bore GI pipe all complete as specified and as directed
S&F stainless steel plate rack of 1mm thick and of size 900x600 mm three tier complete all as specified and directed.
S&F for stainless steel soap dish best quality fixed to plugs with chromium plated brass complete all as specified and as directed.
S&F 500 litre capacity rotational moulded polyethylene water storage tank ISI marked (Cylinderical vertical with close top) hoisted and fixed in position all as specified in SSR Pt-I including dismantling/Demolition of old one and provn of all necessary fittings complete all as specified and as directed.
S&F ball valves 20 mm bore dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic valve ball screwed for iron pipe and fixed complete all as specified and as directed.
Hacking out old unserviceable glass panes from metal framing including punching drilling out old unserviceable glazing pins complete all as specified and as directed.
M&L for 3mm thick plain glass,ordinary quality and glazing with oil putty insquare n exc 0.5sq. m in each pane complete all as specified and as directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
-ditto- all as per item No 63 above but without glazing bars
S&F Steel ventilators with top hung shutter including hinges, steel peg stay, coomplete all as specified and as directed.
-ditto- all as per item No 65 above but without glazing bars
M&L framed work such as grills, grating, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railing framework of water tank and siliar work coomplete all as specified and as directed.
M&L preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint coomplete all as specified and as directed..
Taking down chowkat/frame with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each including removing from site of work complete all as specified and as directed.
All as per item No 69 above but n.exc 1.5 Sqm each
S&F PVC door frame of size 50mmx47mm made out of 5mm plain colour pvc sheet reinforced with mild steel square tubes in opening complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour pvc 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,Panelling of plain colour pvc sheet to be fitted in the ms frame complete all as specified and as directed
S&F Aluminium handles 125mm size cast type anodised coomplete all as specified and as directed. .
S&F aluminium anodised barrel tower bolts 150mm long coomplete all as specified and as directed.
S&F 75mm long size, chromium plated/stainless steel Butt hinges coomplete all as specified and as directed.
S&F factory made plain framed pannelled door shutters 35mm thick(two layer panel) with lock rail and panel of 9mm BWP commercial ply or 12mm verneering on both faces. The size of rail and stile as per IS-1003, SSR Pt-I kiln seasoned and chemically treated coomplete all as specified and as directed.
M&L 35mm thick 2nd class hard wood glazed and skeleton shutter factory made open revated and prepared to receive glass, guage etc with plain chamfered or rounder mitred and rebated, sash bars in any numers divided into squares edges of framing, plain or chamfered or rounded coomplete all as specified and as directed.
S&F of 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including necessary labours; articles n exc 200 cu. cm each coomplete all as specified and as directed.
S&F MS sliding door bolts 250 mm long size plate type stove enamelled black with bright bolt not less than 12mm dia with and including minimum of 6 nuts and bolts, four on bolts plate and two on staple plate complete all as specified and as directed
S&F aluminium anodised barrel tower bolts of extruded section 200mm long (dia of bolt 12mm) complete all as specified and as directed
S&F aluminium handles 150mm size cast type anodised complete all as specified and as directed.
S&F of plain, aluminium sheeting of 0.56 mm thick, Plain straight in stepped flashing (measured as the minimum rectangle form which the pieces can be cut)as in lining complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wood and wood based surface, over 10cm width or girth complete all as specified and as directed.
M&L preparation of old decorative wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint.
M&L 3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as directed
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
M&L for cement concrete PCC(1:3:6) type C2 in roof kerbs ,in lintels upto 1.5m clear span, cills, steps, filling hollow space of steel frame; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and :railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or c:hamfered angles and throating, complete all as specified and as directed
S&F 105 x 60 mm size pressed steel frames made out of cold rolled mild steel sheet of 1.25mm thickness for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete all as specified and as directed
S&F for pressed steel frames made out of cold rolled mild steel sheet of 1.25mm thickness for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125x60mm complete all as specified and as directed
S&F 25 mm thick flush shutters, solid cor construction with block board core and plywood face panels commercial type on both side as in cup board shutter etc complete all as specified and as directed
S&F in repairs of 18/19mm thick prelaminated particle board medium density flat pressed, single layer type with BWR type (ISI marked) fixed with screws to timber frame work. complete all as specified and as directed
S&F teak wood lipping 6mm thick around 18/19mm veneered particle board complete all as specified and as directed
S&F for 75mm long hasp and staple, aluminium anodised safty type including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F of ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed
M & L for M-25 Design Mix as in chajjas and like complete all as specified and as directed
Use and waste of form work to chullah hood, chajjas and like finished fair complete all as specified and as directed
S&F harrison rail/curtain rod, mild steel chromium plated with fixing bracket, stops and complete fitment all as specifed and as directed.
Use and waste of form work to soffit of suspended slab such as roof slab, floor slab, landing and similar work n. exc. 200mm thick complete all as specified and as directed
Use and waste of form work to sides and soffit of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed
Use and waste of formwork edge of concrte flats,treads breaks in floors,window cill,concrete railing openings in concrete walls floor and roofs n exc 20 cm wide and sids of Rcc/Pcc bands in walls horizontal or sloping and similar work exc10cm but n exc 20cm wide complete all as specified and as directed
Taking down old existing tarfelt/Lime concrete of any type and course from roof surface including adjoining parapets and removing the material to a distance exceeding 50 Mtr but n.exc. 100 Mtr including roughening old concrete surfaces by tucking & rubbing with wire brushes and cleaning the surfaces with water to remove all loose dust etc. complete all as specified and derected.
M&L for cutting out cracks to 'V' section (shape) in existing roof slab terracing cleaning out and filling solidely with cement and sand mortar (1:1) complete all as specified and as directed.
M&L for 15mm thick screed bed in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying of APP based polymeric membrance finished even and smooth with out using extra cement compelte all as specified and as directed (Note :WPC shall be measured and paid separately).
M & L water proofing treatment to RCC roof slab including parapet comprising of the following course of treatement / specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of roof including parpet surfaces. Bituminious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE' manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrance of approved manufacturer, 4 mm thick of weight not less than 4.00 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 160 gms per Sqm. Polymeric members shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrance flashing. (c) Application of two coat of bituminous aluminium paint over the polymeric membrane after necessary preparation and cleaning. Note :- (i) Laying APP based polymeric membrance shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm shall be made at the end and 75mm shall be made at the sides of the polymeric membrance respectively and sealed all ovelaps and joints as per Manufacturers instructions. (iii) APP based polymeric membrance shall be "SUPER THERMOLAY" manufactured by M/S STP LTD.
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall with clamp incl taking down old and U/S CI/PVC/AC soil pipe including fittings complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and as directed.
S&F 110mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F 110mm dia PVC SWR vent cowl complete all as specified and as directed.
M&L coloured glazed ceramic tiles 300 x 200x 6-7mm, thick as in vertical faces/dado set and jointed in neat cement slurry and pointed in coloured cement over 10mm thick rendering in CM (1:4) as in vertical surfaces / dados complete all as specified and as directed.
S&F of non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floor etc set and jointed in neat cement slurry over 15mm thick screed bed for laying floor finishes in CM (1:6) complete all as specified and as directed
S&F of non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc set and jointed in neat cement slurry over 15mm thick screed bed for laying floor finishes in CM (1:6) complete all as specified and as directed
Ditto all as per item No 111 but as in vertical surface such as skirrting complete all as specified and as directed.
S&F 50mm bore PVC (SWR) high density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm pipes single socketed, in any lenth with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F in repairs swivel shower 125mm dia of CP with shower arm 15mm size any colour for fixing with 15mm pipe complete all as specified and as directed..
M&L for preparation for newly plastered surfaces of chajja/facia etc and applying two coats of weather coat exterior emulsion paint as per manufacturer's instruction etc complete all as specified and as directed.
M&L for complete removal of existing treated surfaces of wall including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping and applying two coat of cement base paints as per manufacturers instruction on the same surfaces complete all as specified and as directed.
M&L for applying two coats of oil bound distemper including preparation of newly plastered wall surface over a coat of 1mm thick wall care putty etc complete all as specified and as directed.
M&L for complete removal of existing treatment from walls and applying two coats of oil bound distemper on walls over a coat of 1mm thick wall care putty including preparation of surfaces complete all as specified and as directed.
Roughening surfaces of old concretefloor by picking, sweeping clean andwashing down with water to remove dust, etc complete all as specified and directed.
M&L for framed work as in doors frame of angle or other section conforming to Fe 410-W(Gde-E- 165)quality-A with gusset plates, rails, braces, etc., and including fixing of steel hinges or other door fittings complete all as specified and directed.
M&L machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over 20mm thick screed bed CM (1:6) with and including roughening cement concrete surfaces by picking, sweeping, clean and washing down with water to remove dust etc incl 25 mm thck sand bed and coping etc complete all as specified and as directed.
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe minimum overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as specified and as directed.
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length CI brackets in lieu of old unservisable push button flushing system complete all as specified and as directed.
S&F in repair Water closet(squatting pan),orrisa pattern,size580x440mm white with integral foot rests excluding flushing cistern and flushin pipe complete including provision of lime concrete bedding complete all as specified and as directed.
Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and directed.
M&L for Consealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core malti stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :- (a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the independent board
(d) One socket out let 5/6 amps point on the same board
All as per item No 128 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F in switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F ding dong bell, AC, Single pole, 220/240 Volts, surface type complete all as specified and directed
S&F in bell push flush type 5/6 amps single pole complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F in lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S & F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F in replacement of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 double side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
M & L for street light bracket made out of GI pipe light grade 32 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected in common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and as directed.NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’. (ii) Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length).
M & L for 25 mm dia PVC conduit having a wall thickness not less than 1.4 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) with all accessories for submain wiring complete as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed.
S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one as specified and as directed.
Disconnecting and removing U/S building security light fitting of any type from bldg and Supply and fixing new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07system of not less than 40 Watts IP 66 type incl standard fittings pressure die cast aluminium housing, heat resistant toughened glass, epoxy powder coated finsh complete with Electronic driver, Surge protector not less than 5 KV and all accessories duly prewired complete all as specified and directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangment to the same will be on the cable.
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks laid dry and flat complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
M&L 80 mm bore steel tubing light grade ISI marked for protection of cable laid in horizontal bore including necessary joints complete all as specified and as directed.
Dismantling and taking out four pole structure/ HT OCB panel consisting of two Nos OCBs of any size and decription from sub stations and deposit to MES store yard complete all as speccified and as directed. Note: Transpotation charges shall be deemed to be include in this unit rate.
M&L for painting to LT Panel( inside and outer side complete) of various sizes installed in varios sub stn with two coats superior quality synthetic enamelled paintby spraying of existing colour after scraping rust etc. complete all as specified & directed.
M&L for painting to shutters and all metals/ iron material installed in various sub stn with one coat of superior quality synthetic enamelled paintby spraying of existing colour after scraping rust etc. complete all as specified & directed.
M&L for painting to transformes of capacity 100 KVA to 315 KVA complete sizes installed in varios sub stn with two coats superior quality synthetic enamelled paintby spraying of existing colour after cleaning, scraping rust etc. complete all as specified & directed.
M&L for painting to transformes of capacity 400 KVA to 500 KVA complete sizes installed in varios sub stn with two coats superior quality synthetic enamelled paintby spraying of existing colour after cleaning, scraping rust etc. complete all as specified & directed.
M&L for painting to transformes of capacity 750 KVA complete sizes installed in various sub stn with two coats superior quality synthetic enamelled paintby spraying of existing colour after cleaning, scraping rust etc. complete all as specified & directed.
M&L for painting to transformes of capacity 750 KVA trolley mounted complete installed in various sub stn with two coats superior quality synthetic enamelled paintby spraying of existing colour after cleaning, scraping rust etc. complete all as specified & directed.
Supplying , installation, testing and commissioning of RMU 6 way HT 11 KV outdoor type, 21 KA for 1 sec, rated voltage-12KV, operation voltage-11 KV, rated lightning withstand voltage - 95 KV, rated frequency - 50Hz, 630 amp copper busbar SF6 insulated non extensible compact switch gear consisting of five nos fixed motorised load break switch (LBS) and one nos fixed motorised Vaccum circuit breaker (VCB) in SF-6 gas pressure designed for minimum 1.4 Bar & insulated, welded, stainless steel enclosed with minimum 2.5 mm thickness totally enclosed Ring Main Unit IP-67 protection with self powered microprocessor based complete numerical over current & earth fault relay comprising of the following specification/equipment :- Note :- Contractor shall supply outdoor RMU with out door enclosure. (a) The circuit breaker and earthing switch shall be lockable in the open or closed position by suitable number of padlocks of suitable size (b) Inter panel barrier to prevent arc propagation fron one panel/compartment to other. (c) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (d) Isolating plug (e) Vaccum circuit breaker unit insulated in SF6 media shall comprising the following : (i) Assembly of VCB interrupter complete with epoxy supprt insulator and self alligning isolating contacts with rating 11KV 630 amps ,21 KA for 3sec , 50 Hz. (ii) Manual charged and manual operated independent closing / triping, trip free operating mechanism and breaker closed/open, spring charge/discharge indication. (iii) Mechanical operation counter-02No (iv) One bus bar chamber including a set of 3 phase 630 amps copper bus bar. (v) Strip heater 230 volts AC single phase 80 watt. (vi) Current transformer chamber comprising of 3 nos single phase resin cst CT's of 100-50/5 and accuracy class 1.0 for metering and class 5P10 for protection in all outgoing VCB feeder - set of 3 (e) One no potential transformer(PT) three phase, dry type ( resin cast) draw out type 11kv/110 volts, 100VA burden, accuarcy class 1.0 with HT & LT HRC fuses for primary and secondary complete as per IS-3156- 01 no. (f) SCADA Self powered solid state numerical O/C & E/F relay for complete protection of HT,11KV,three phase feeder having facility to record fault current with date & time with suitable communication port as approved by GE- 01 nos (g) Arc flash supervision of circuit breaker,cable and busbar compartment. (h) Digital SCADA compatible meter indicating line/phase current, line/phase voltage, power factor, KVAR,KVA, frequency etc with accuracy class 1.0 for all outgoing feeder of RMU-05 Nos. NOTE:- (i) All foundation works for RMU as per manufacturer recommendation for the installation shall be deemed to be included in the quoted ratesincl excavatin & PCC work.. (ii) Contractor shall submit detailed drawings with specification of the RMU and get necessary approval before placing final order to the manufacturer. (iii) All outgoing / incoming existing HT cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables shall be deemed to be included in the quoted rates. (iv) Any item missed out above but is technically required for safe and proper operation of equipment shall be deemed to be included in the quoted rate. (v) The material will be purchased only through manufacturing company.
Supplying , installation, testing and commissioning of RMU 4 way HT 11 KV outdoor type,21 KA for 1 sec, rated voltage-12KV, operation voltage-11 KV, rated lightning withstand voltage - 95 KV, rated frequency - 50Hz, 630 amp copper busbar SF6 insulated non extensible compact switch gear consisting of three nos fixed motorised load break switch (LBS) and one nos fixed motorised Vaccum circuit breaker (VCB) in SF-6 gas pressure designed for minimum 1.4 Bar & insulated, welded, stainless steel enclosed with minimum 2.5 mm thickness totally enclosed Ring Main Unit IP-67 protection with self powered microprocessor based complete numerical over current & earth fault relay comprising of the following specification/equipment :- Note :- Contractor shall supply outdoor RMU with out door enclosure. (a) The circuit breaker and earthing switch shall be lockable in the open or closed position by suitable number of padlocks of suitable size . (b) Inter panel barrier to prevent arc propagation fron one panel/compartment to other. (c) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (d) Isolating plug (e) Vaccum circuit breaker unit insulated in SF6 media shall comprising the following : (i) Assembly of VCB interrupter complete with epoxy supprt insulator and self alligning isolating contacts with rating 11KV 630 amps ,21 KA for 3sec , 50 Hz. (ii) Manual charged and manual operated independent closing / triping, trip free operating mechanism and breaker closed/open, spring charge/discharge indication. (iii) Mechanical operation counter-02No (iv) One bus bar chamber including a set of 3 phase 630 amps copper bus bar. (v) Strip heater 230 volts AC single phase 80 watt. (vi) Current transformer chamber comprising of 3 nos single phase resin cst CT's of 100-50/5 and accuracy class 1.0 for metering and class 5P10 for protection in all outgoing VCB feeder - set of 3 (e) One no potential transformer(PT) three phase, dry type ( resin cast) draw out type 11kv/110 volts, 100VA burden, accuarcy class 1.0 with HT & LT HRC fuses for primary and secondary complete as per IS-3156- 01 no. (f) SCADA Self powered solid state numerical O/C & E/F relay for complete protection of HT,11KV,three phase feeder having facility to record fault current with date & time with suitable communication port as approved by GE- 01 nos (g) Arc flash supervision of circuit breaker, cable and busbar compartment. (h) Digital SCADA compatible intelligent panel meter indicating line/phase current, line/phase voltage, power factor, KVAR,KVA, frequency etc with accuracy class 1.0 for all outgoing feeder of RMU-03 Nos. NOTE:- (i) All foundation works for RMU as per manufacturer recommendation for the installation shall be deemed to be included in the quoted rates. (iii) Contractor shall submit detailed drawings with specification of the RMU and get necessary approval before placing final order to the manufacturer. (iv) All outgoing / incoming existing HT cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables shall be deemed to be included in the quoted rates. (V) Any item missed out above but is technically required for safe and proper operation of equipment shall be deemed to be included in the quoted rate. (vI) The material will be purchased only through manufacturing company.
Supplying , installation, testing and commissioning of RMU 3 way HT 11 KV indoor type,21 KA for 1 sec, rated voltage-12KV, operation voltage-11 KV, rated lightning withstand voltage - 95 KV, rated frequency - 50Hz, 630 amp copper busbar SF6 insulated non extensible compact switch gear consisting of two nos fixed motorised load break switch (LBS) and one nos fixed motorised Vaccum circuit breaker (VCB) in SF-6 gas pressure designed for minimum 1.4 Bar & insulated, welded, stainless steel enclosed with minimum 2.5 mm thickness totally enclosed Ring Main Unit IP-67 protection with self powered microprocessor based complete numerical over current & earth fault relay comprising of the following specification/equipment :- Note :- Contractor shall supply outdoor RMU with out door enclosure. (a) The circuit breaker and earthing switch shall be lockable in the open or closed position by suitable number of padlocks of suitable size (b) Inter panel barrier to prevent arc propagation fron one panel/compartment to other. (c) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (d) Isolating plug (e) Vaccum circuit breaker unit insulated in SF6 media shall comprising the following : (i) Assembly of VCB interrupter complete with epoxy supprt insulator and self alligning isolating contacts with rating 11KV 630 amps ,21 KA for 3sec , 50 Hz. (ii) Manual charged and manual operated independent closing / triping, trip free operating mechanism and breaker closed/open, spring charge/discharge indication. (iii) Mechanical operation counter-02No (iv) One bus bar chamber including a set of 3 phase 630 amps copper bus bar. (v) Strip heater 230 volts AC single phase 80 watt. (vi) Current transformer chamber comprising of 3 nos single phase resin cst CT's of 100-50/5 and accuracy class 1.0 for metering and class 5P10 for protection in all outgoing VCB feeder - set of 3 (e) One no potential transformer(PT) three phase, dry type ( resin cast) draw out type 11kv/110 volts, 100VA burden, accuarcy class 1.0 with HT & LT HRC fuses for primary and secondary complete as per IS-3156- 01 no. (f) SCADA Self powered solid state numerical O/C & E/F relay for complete protection of HT,11KV,three phase feeder having facility to record fault current with date & time with suitable communication port as approved by GE- 01 nos (g) Arc flash supervision of circuit breaker,cable and busbar compartment. (h) Digital SCADA compatible intelligent panel meter indicating line/phase current, line/phase voltage, power factor, KVAR,KVA, frequency etc with accuracy class 1.0 for all outgoing feeder of RMU-02 Nos. NOTE:- (i) All foundation works for RMU as per manufacturer recommendation for the installation shall be deemed to be included in the quoted rates. (ii) Contractor shall submit detailed drawings with specification of the RMU and get necessary approval before placing final order to the manufacturer. (iii) All outgoing / incoming existing HT cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables shall be deemed to be included in the quoted rates. (iv) Any item missed out above but is technically required for safe and proper operation of equipment shall be deemed to be included in the quoted rate. (v) The material will be purchased only through manufacturing company.
Supplying, laying, jointing, testing and commissioning HT XLPE insulated, screened, PVC bended galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductor screening with extruded semi conditioning layers insulation screening with armoured PVC (ST-2) outer sheathed cable confirming to IS 7098 (Pt-II) 11 KV grade (Earthed) suitable for earthed system cross sectional area 95 sqmm 3 core H.T.U.G cable laid in trenches/through GI pipe/fixed along with pole complete all as specified & as directed. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangment to the same will be on the cable.
Supply and installation (above ground) including testing HT joint box 2 way outdoor type of size 1500x1000x900mm (overall) made out 3.15mm thick CRCA sheet with supprt of angle iron frame of size 40x40x6mm with KIOSK BOX and comprising of 03 Nos HT procelain bushing and copper round bus bar 12mm dia rigidly mounted on bakelite sheet 12mm thick to support insulatiors of suitable size and shape including providing necessary electric connection and applied two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces (internally & externally) including PCC foundation base of size 1700mm x 400mm x 1400mm height (700mm above GL & 500mm below GL) with PCC 1:3:6 type C1 using 20mm graded aggregate complete including necessary excavation and earth work for foundation and necessary electric connection complete and including dismantling of unserviceable joint box complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exc 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking up/laying under ground electric cable complete all as specified and as directed
Returning, filling in,including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed as a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 5cm covering above the top edge of cable after laying complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type-1 flat of size 300 mm x 180mmx40mm for protection of HT UG cable conforming to IS -5820-1970 and revised from time to time complete all as specified and as directed
M&L 40mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed
Supply, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable, for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for XLPE insulated armoured aluminum conductor cable of size 3 core 95 sqmm complete all as specified .
Supply, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable, for iutdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for XLPE insulated armoured aluminum conductor cable of size 3 core 95 sqmm complete all as specified
Earthing with GI earth plate electrode 600x600x6 mm thick buried directly in ground vertically to a depth of not less than 2.25m below the ground level with top edge of earth plate at a depth of not less than 1.5m below the ground level connected to galvanized iron strip of 32mm x 6mm earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth strip protected by and including GI Pipe 40mm bore (light grade upto a length of 7.5 mtr and connected to main test point as directed and including concrete pit using PCC (1:3:6) type C-1, precast RCC cover slab of size 55x55x15cm reinforced with 8mm dia TMT bars @ 150mm C/C both ways with one handle for lifting, made out of 8mm dia MS bar embeded in precast cover slab, in and including funnel with wire mesh, 20mm bore galvanised or steel pipe (light grade) for watering, adequate quantity of charcoal & salt in alternative layers including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No. 3 of SSR Part-I including necessary testing on completion complete all as specified and as directed.
CHAKRABORTY AND SONS
M/S R. K. INDUSTRIES
NIRMAL SALES CORPORATION
VARNI BUILDERS
Prasur Electricals & Engineering Co.
Hindustan Traders
S.N. GHOSH AND CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .