Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹118.2 CrAccepted-AOC | ₹118.2 Cr | L1 | Accepted-AOC accepted |
| 2 | L2₹119.0 CrRejected-Finance | ₹119.0 Cr | L2 | Rejected-Finance REJECTED |
| 3 | L3₹122.0 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹122.0 Cr | L3 | Rejected-Finance REJECTED |
| 4 | L4₹122.9 CrRejected-Finance | ₹122.9 Cr | L4 | Rejected-Finance REJECTED |
| 5 | L5₹128.6 CrRejected-Finance | ₹128.6 Cr | L5 | Rejected-Finance REJECTED |
Updated dates
Tender Value
₹138.3 Cr
EMD Value
₹1.5 Cr
Closing Date
17 Nov 2025, 10:00 amClosed
Hemraj Sharma Sc- F
POST BOX 1569 AKBAR ROAD SECUNDERABAD 500009
Provision of Civil Works AND Allied Services for Certain Technical Buildings Phase I at SFC Jagdalpur
2025_DRDO_881248_1
80633/CIV/JAG/SFC/CON
Open Tender
Civil Works
720 days
SFC JAGDALPUR
AS PER NIT
2 documents required · 2 mandatory
₹3,000
CCERND South
₹1.5 Cr
22 Dec 2025
13 Oct 2025
17 Nov 2025
13 Oct 2025
17 Nov 2025
3 Nov 2025
14 Oct 2025 - 21 Oct 2025
SUB HEAD - I : EARTH WORK, EXCAVATION & DISMANTLING
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
All kinds of Soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
Ordinary rock
Hard rock (blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of Soil
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock.
Hard rock (blasting prohibited)
Hard rock (with blasting )
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Earth work in excavation by mechanical means using Hydraulic excavator (Bobcut 3-.6T Mini Excavator) for Casting Pit Within Secant piles in top down method upto 20m deep including lowering excavator and removal of excavated soils by placing Winch Machenisam with supporting assambly at groud level including dressing of sides and ramming of bottoms and disposal of surplus excavated soil as directed.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50m & lift upto 1.5m.
Supplying and filling of earth obtained from outside MoD land (including royalty) by mechanical transport including lead and lift and filling in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden on steel rammers, rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads.
Supplying and filling of earth obtained within MoD land by mechanical transport including lead and lift and filling in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden on steel rammers, rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads.
Credit for Hard rock Obtained from above
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) ; specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
SUB HEAD - II : ANTI-TERMITE TREATMENT :
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Post Construction anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below plinth protection concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
SUB HEAD - III : PLAIN & REINFORCED CEMENT CONCRETE
Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M7.5 grade with minimum cement content of 200 kg /Cum
Concrete of M10 grade with minimum cement content of 220 kg /cum
Concrete of M15 grade with minimum cement content of 240 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
All works upto plinth level:Concrete of M35 grade with minimum cement content of 370 kg/cum
All works above plinth level upto floor V level : Concrete of M25 grade with minimum cement content of 330 kg/cum
All works above plinth level upto floor V level : Concrete of M35 grade with minimum cement content of 370 kg/cum
All works above plinth level upto floor V level : Self compacting concrete (SCC) M40 as approved by Engineer-in-Charge.
Add Extre For Using M-Sand/Crushed Sand in Lieu of River Sand in concrete & Plastring SurfaceWorks
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Plinth and above all levels.
Thermo-Mechanically Treated bars of grade Fe-550D or more.
Design & Execution of Post Tensioning works including decoiling the strands, cutting to the required lengths, supplying and laying of HT strands, sheathing(GI corrugated ducts 80mm x 20 mm 0.30 mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages including the supply of stressing anchorages suitable for 5-5 & 5-4 Tendons, grout vents, making dead end anchorages including flowering the strands, fixing tendon support bars, supervising the fixing of anti bursting reinforcement, stressing the cables, end trimming, grouting the cables with cement and admixtures, with required Plant & Machineries, tools and tackles, consumables etc., including obtaining approval from client / consultant for the work done as per the requirement of Engineer-In charge at site. Eligibility criteria for PT Vendor 1. The PT Agency should have minimum 10 (Ten) years experience in post – tensioning works. 2. The PT Agency may be either a registered partnership firm or a company limited by shares having experience in similar construction and the design Engineer should have minimum 10 years of design experience. 3. The PT Vendor Should Posses Design Experience & Execution Experience More than 10 Years in India. 4. The PT Systems (Anchorages) should be in use for more than 10 years and it should be validated by systems performance test conducted in a registered laboratory (IIT). a) Anchorage efficiency b) Load transfer test 5. PT agency should have the Proprietorship of their systems and their assembly. 6. Similar kind of PT Projects Completed in the last 3 years shall form part of the qualification. Measurement shall be anchorage to anchorage + stressing length + profile length. (Cement/admixture/Reinforcement will be supplied by the Client/Main Contractor) Approved Vendor : UCON , VSL , Tech 9
10 B Block (22.8m & 15.8m Span Beams)
7C & 7D Block (14.5m & 13.5m Span Beams)-2No’s of slabs
3C Block (4.2m Span Beams)
CCR Block (15.5m Span Beams)
Centring and shuttering including strutting, propping, etc. and removal of form for the following items of RCC work at all depths and heights complete as per drawings, specifications and as per direction of Engineer-in-charge.
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases
Weather shade, Chajjas, corbels etc., including edges
Supplying Laying and Deshuttring of Paschal / Equvalent type formwork for walls and Columns. As approved by Engineer-in-Charge.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20m nominal size) over 75mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles (in all kinds of soils including pebbls/bolders) of Specified grade of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including disposal of excavated earth with all lifts and leads(length of pile for payment shall be measured up to bottom of pile cap). Including bracing, sturting the piles during excvation of earth in Pit Note:Cost insludes erection & De erection of strutting and bracing beams at 4levels to suppory secant piles during excavation of Pit within secant piles strutting & bracing beams are contractor's property after complete construction of casting pit. Secant Piles of 750mm Dia. a) For Female Piles (using M25 with 330Kgs of Cement)
b) For male Piles (using M35 with 428Kgs of Cement) rate includes cutting of soft or female pipes
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality: L D- 2.5 Rectangular shape 600x600 mm internal dimensions - (Ground Floor Trench & Sump Cover)
Expansion Joint
Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesive ReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape.
Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550D or more.
Providing and applying Wet Steel Fiber Reinforced Shotcrete of M30 grade using not less than 360 kg of cement in successive layers of 30 mm thick, as per specifications & drawings and as directed by Engineer in charge, including supplying and mixing premium quality steel fibres with ASPECT ratio of 65 and tensile strength more than 1000 MPa with minimum steel fiber content of 40 kg/cum of shotcrete. The rate shall include cost of all materials, labour, equipments, etc,,required for completion of the work.
Providing and applying Plain Wet Shotcrete of M25 grade using not less than 340 kg of cement as per specifications & drawings and as directed by Engineer in charge including cost of all materials, labour, equipments, etc, rec, jired for completion of the job for Secondary shotcrete.
SUB HEAD - IV : MASONRY WORK
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300mm/345mm/700mm thick and above AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
SUB HEAD - V : FINISHING AND SURFACE TREATMENT
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (External wall & Parapet wall smooth finished)
6mm cement plaster of mix for celling: (a) 1:3 (1 cement : 3 fine sand)
12 mm thick cement plaster with cement mortar 1:6 (1 cement: 6 coarse sand) on internal surfaces of walls (brick or concrete surfaces) finished smooth with trowel including scafolding, curing etc., complete at all heights : (Internal finishing side)
Supplying and applying of One coat of 13mm thick Gypsum plaster on internal surfaces of walls (brick or concrete surfaces) finished smooth with trowel including scaffolding, curing etc., complete at all heights : (Internal finishing side) Make : Saint Gobain or Equivalent
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge 20 mm wide and 15 mm deep groove
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. : per bag of 50kg cement used in the mix
White washing with Cement/Lime to give an even shade (Ceiling & Shaft Area) New work (three or more coats)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Internal finishing side) Two coats
Epoxy Flooring - 3mm
Surface Preparation: Preparing the existing surface of floor by diamond wheel grinding and cleaning by wire brushing etc, to remove all dirt, dust, oil etc to expose clean sound base concrete. Cost shall include treatment of construction and control joints filling as per manufacturer's specification and direction of Engineer In Charge. Any imperfections in the concrete shall be treated with suitable epoxy / polyurethane system as per manufacturer specification which shall be paid separately Epoxy Floor Topping: Providing, supplying, and applying to the designated floor areas with resin-based epoxy flow-applied flooring at 3mm thick applied at coverage of 3 litres / sqm using serrated trowel and spike roller. The floor topping shall be applied over prepared concrete and epoxy resin primed surface at coverage of 5.5 sqm / litre using roller brush / paint brush. The topping shall achieve compressive strength of >67 N/mm², flexural strength of >25 N/mm², tensile strength of >12 N/mm² at 7 days when tested to BS6319 Part-7, Abrasion resistance: 0.081mg / cycle loss tested with CS 17 wheels, Pull of Adhesion strength (@ 7days) >3 N/mm², Shore D Hardness > 70. At 27°C, it shall be aloowed foot traffic at 24 hours and vehicular traffic at 48 hours.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (Parapet wall paint - Exterior Side)
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
External Elevation Wall Coating
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
SUB HEAD - VI : FLOORING
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Double Charged Vitrified tiles, of size Size of Tile 600 x 1200 mm Vitero of Aparna Make/ Marbunite of Johnson make /(SAPPHIRE SERIESof Kajaria Make or Equvalent
Double Charged Vitrified tiles, of size Size of Tile 600x600 mm Vitero of Aparna Make/ Marbunite of Johnson make /TROPICANA SERIES of Kajaria Make or Equvalent
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Double Charged Vitrified tiles, of size Size of Tile 600x600 mm Vitero of Aparna Make/ Marbunite of Johnson make / Kajaria Make or Equvalent
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge of 450 mm Finished Floor Height (FFH) consisting of:
(a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
(b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange).
The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : (Granite flooring) Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture exceptBlack, Cherry/Ruby Red. (Granite flooring)
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand),including pointing in white cement with an admixture of pigment to matchthe stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade. (Granite Skirting)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (10mm thickness) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Kitchen & toilet dado)
Providing and laying VDF of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (Trimix Road) (Note:- Cement content considered in this item is @ 330 kg/Cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine.
Providing and filling in position at expansion joints with poly sulphate sealants of approved brand.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm
Granite stone flooring with 18 mm thick marble stone, as per sample of Granite approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete:
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18mm Thick
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
PU Flooring
Surface preparation: Surface shall be prepared thoroughly by mechanical scarification to remove all loose & deleterious matter, dust etc. Clean the surface by vacuum machine to have dust free concrete substrate. Groove cutting: Cutting of Anchor groves, of size min 8 mm X 8 mm, at door openings, along the wall, around columns and on both sides of the joint of two colours. Clean the groves with vacuum machine. Application of Floor coating: Providing and applying Seamless, High Chemical resistant, Impact resistant Matt finished Hygienic, self-levelling, Polyurethane concrete MYK Arment FloArm TOP HPU 4 Plus /fosroc or equvalent of approved colour, at a consumption of 7.2 kg/sqm 4mm thickness. Allow the system to dry. Coving: Providing & applying PU Coving at 50 mm * 50 mm size using MYK Arment FloArm HPU C/fosroc or equivalent Coving finishing will be done by MYK Arment PUD//fosroc or equvalent Coating and complete as per manufacturers specification.
Anti Static Flooring Surface Preparation: Preparing the existing surface of floor by shot blasting / scarification and cleaning by wire brushing etc, to remove all dirt, dust, oil etc to expose clean sound base concrete. Cost shall include treatment of construction and control joints filling as per manufacturer's specification and direction of Engineer in Charge. Any imperfections in the concrete shall be treated with suitable epoxy / polyurethane system as per manufacturer specification which shall be paid separately. Providing supplying and applying epoxy self-leveling antistatic floor topping to the designated areas. Application of primer using Nitoprime 25 over the prepared concrete surface at 5.5 to 6.5m2/litre. Fix 3M’s copper earth strip of size 25mm wide and 80 microns thick is fixed over the epoxy primer along the perimeter and internally. General panel size shall be of 3.0m x 3.0m. The joints are connected to the earth connection strap in the building. The above surface will be treated with aqueous anti-static epoxy system, Nitoflor SL conductive undercoat spread at the specified coverage of 3.75m2/litre. The conductivity of the Nitoflor SL Conductive undercoat is 3x10³ohms – 9x10³ ohms and followed by Nitoflor SL Conductive topcoat at 2mm thickness an epoxy based antistatic self-leveling flooring compound. The surface resistance of the conductive topping in accordance with BS 2050: 1978 (A-1984) and DINEN 1081, the static conductive topping including undercoat shall be in the range of 25x103ohms – 1x10⁶ohms when tested for static decay using Metriso Megger as per ASTM F 150. The under coat shall be connected to earthing devices using self-adhesive copper tape. The above systems shall comply with the provisions of BS 2050:1978 specifications for Anti-Static and Conductive products for Electrical resistance. The coat shall possess a minimum Compressive strength of 60N/mm², minimum Tensile strength of 11.5N/mm², minimum Flexural strength of >20N/mm². The floor shall be prepared and the coating mixed and applied in accordance with the manufacturer’s current data sheet.
SUB HEAD - VII : STEEL WORK
Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Steel work welded in built up sections / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Supplying and fixing of Motorised Industrial Sliding Door assembly for mounting with bottom rail on RCC and columns and lintel on RCC or M.S. channel, with bidirectional opening and door frame constructed of 200 mm × 100 mm × 5.0 mm M.S. pipe for top horizontal and vertical members and 200 mm × 100 mm × 5.0 mm M.S. pipe for bottom horizontal members; internal periphery infills shall be 150 mm × 50 mm × 3.0 mm M.S. pipe with horizontal and vertical framing of 150 mm × 100 mm × 3.0 mm M.S. pipe, all MS fabrication to receiveTwo coats of Polyurethane spray paint over one coat of epoxy primer 90-120 microns by spray to provide the specified protective finish in silver similar to RAL 9006 or grey similar to RAL 7015 or blue similar to RAL 5010 or orange similar to RAL 2000 or other RAL colour on request at surcharge; external cladding shall be 0.5 mm thick
precoated corrugated PEB sheet fixed full height within the frame on one face with colour finish similar to RAL 5012 or RAL 9002 as specified; top roller assembly shall comprise sliding bracket, Italian make top track of galvanised natural finish and Italian make top track rollers with galvanised adjustable top track brackets for wall fixing; bottom rail shall be C channel with 20 mm square bar reinforcement and incorporate nylon buffer with stainless steel plate. The drive system shall be European electromechanical actuator Sonic 4000T, rack driven with hardened and tempered imported galvanised rack and integral electronic control unit, rated capacity 4000 kg, duty cycle S1=100 percent, power supply 230 V AC 50 Hz, input current 3 A, nominal torque 100 Nm, opening and closing speed 0.29 m/s, manual release by key operation product dimensions 520 × 995 × 230 mm. Control system shall provide travel control by limit switches to sense open and closed positions and an advanced electronic control unit permitting operation time adjustment, partial opening, automatic closing, step by step control, stop safety and reverse safety and MPS startup at maximum power to overcome initial friction; control interface shall be three station push button. Safety devices shall include a pair of photocells mounted on anodised aluminium vertical supports and shall be CE marked in accordance with European Machinery Directive 2006/42/EC and type tested to EN 13241‑1; motor protection shall be by internal thermal switch. The system shall allow manual operation during power failure, be of highly compact dimensions and operate with extremely low noise with all complete as per Manufacturer,s specification.(Gandhi, Avians or Equvalient Make) 6500x15000mm
Providing and fixing of motorised rolling shutter with Providing and fixing in position rolling shutter of single skinned Galvanised steel laths section of 0.9 mm for clear width ≤ 3.5m as per IS 6248 laths Each lath is retained by interlocking with each other. specially designed pipe shaft with brackets, side guides and Three station push button with deadman control with Motorised operation including top cover,Two coats of Polyurethane spray paint over one coat of epoxy primer 90-120 microns. all complete as per manufacturers specification Electrically operated European make. The bottom lath shall be coupled to a lock plate fabricated from 3.15mm thk Mild steel profile for additional strength with rubber seal. all complete as per Manufacturer,s specification 3000x4000mm
Supplying and fixing of Motorised Industrial Double leaf Sliding Door system mounted on RCC or M.S. channel, with bidirectional opening and door frame constructed with top horizontal and vertical frame members of 75 mm × 75 mm × 3.0 mm M.S. pipe, bottom horizontal profile 100 mm × 75 mm × 3.0 mm M.S. pipe, infill and side covering to use 40 mm × 40 mm × 2.5 mm M.S. pipe and internal horizontal/vertical framing to use 80 mm × 40 mm × 2.5 mm M.S. pipe; all MS members to receive Two coats of Polyurethane spray paint over one coat of epoxy primer 90-120 microns prior to installation. External cladding shall be 0.5 mm thick precoated corrugated PEB sheet fixed on one side, colour finish to match RAL 5012 (light blue) or RAL 9002 (off white) as specified. Top track shall be an Italian‑make galvanised top track with natural finish, supported on galvanised adjustable wall‑fixing top track brackets and running on Italian‑make galvanised top track rollers; bottom running to incorporate nylon buffer with stainless steel plate. Drive system shall be European electromechanical actuator with rack‑driven robust drive unit incorporating an integral electronic control unit; drive capacity 1500 kg, duty class intensive use, working cycle 70%, nominal supply 230 Vac with 24 Vdc control, nominal absorption 0.9 A, maximum torque 74 Nm, opening/closing speed 0.16 m/s. Powertrain shall use imported galvanised hardened and tempered rack; release for manual opening shall be key‑operated and compact product dimensions 330 × 240 × 360 mm. Travel control shall be by integral electronic control unit with limit switches to sense open and close positions; control features to include operation time adjustment, partial opening, automatic closing, step‑by‑step control, stop safety and reverse safety, and MPS startup at maximum power to overcome initial friction from ice or dust. Motor protection shall include internal thermal switch; the drive unit shall permit highly compact and silent operation and provide a manual override for operation during power failure. Control wiring shall terminate to a three‑station push‑button control with deadman function and the system shall include a pair of CE‑marked photocells mounted on anodised aluminium vertical stands compliant with European Machinery Directive 2006/42/CE and EN 13241‑1 type testing with all complete as per Manufacturer,s specification.(Gandhi, Avians or Equvalient Make) 5000x4000mm
Supplying and fixing of Manual Double Leaf Hinged Door with frame comprising 100 mm × 100 mm × 3.0 mm M.S. pipe for horizontal and vertical profiles; infill vertical profile 100 mm × 50 mm × 3.0 mm M.S. pipe; infill horizontal profile 100 mm × 50 mm × 3.0 mm M.S. pipe; cladding full‑height 1.5 mm thick M.S. sheet tray fixed to one side of the frame; door accessories to include handle, locking arrangement and heavy hinges; all MS surfaces to receive Two coats of Polyurethane spray paint over one coat of epoxy primer 90-120 microns.(Gandhi, Avians or Equvalient Make)
Manual Double Leaf Hinged Door of size 4.0x4.0
Manual Double Leaf Hinged Door of size 5.0x6.0
Manual Double Leaf Hinged Door of size 5.0x4.0
Manual Double Leaf Hinged Door of size 6.0x6.0
Manual Double Leaf Hinged Door of size 4.0x5.0
Manual Double Leaf Hinged Door of size 4.5x5.0
Manual Double Leaf Hinged Door of size 3.0x4.0
Supplying and fixing of Manual Single Leaf Hinged Door with frame comprising 75 mm × 75 mm × 3.0 mm M.S. pipe for horizontal and vertical profiles; infill vertical profiles 75 mm × 50 mm × 3.0 mm M.S. pipe; infill horizontal profiles 75 mm × 50 mm × 3.0 mm M.S. pipe; cladding full‑height 1.5 mm thick M.S. sheet formed as tray fixed to one side of the frame; door accessories to include handle, locking arrangement and heavy hinges sized for the door leaf weight and duty; all exposed and concealed MS surfaces to receive Two coats of Polyurethane spray paint over one coat of epoxy primer 90-120 microns.(Gandhi, Avians or Equvalient Make)
Manual Single Leaf Hinged Door of Size 3.0x3..5
Manual Single Leaf Hinged Door of Size 3.0x3.0
Manual Single Leaf Hinged Door of Size 2.5x3.0
Manual Single Leaf Hinged Door of Size 2.4x2.5
Manual Single Leaf Hinged Door of Size 2.0x2.0
Manual Single Leaf Hinged Door of Size 1.6x2.5
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover.
Providing and fixing ball bearing for rolling shutters.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Floor Mounted , Side Mounted , Hand Rail
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B, fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked with necessary screws including lipping
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
SUB HEAD - VIII : ALUMINIUM / WOODEN
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-incharge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Supply and fixing of pre-painted steel casement/ open able windows base steel as per IS 513 of - 0.58 mm thick 'D quality, galvanized as per IS 277, finish painted with a polyester paint, section for outer frame of 46 x 52 mm section for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading 18 x 25 mm panelled with 6mm wired glass fitted with EPDM gaskets, handle made of high grade aluminium powder coated frames fixed to the concrete /masonry wall by means of self expanding screws 10mm Sq bar rod @ 100 mm pitch Fixing on outer frame.NCL or Equvalent Makes
Supply and fixing of pre-painted steel casement/ open able Ventilators base steel as per IS 513 of - 0.58 mm thick 'D quality, galvanized as per IS 277, finish painted with a polyester paint, section for outer frame of 46 x 52 mm section for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading 18 x 25 mm panelled with 6mm wired glass fitted with EPDM gaskets, handle made of high grade aluminium powder coated frames fixed to the concrete /masonry wall by means of self expanding screws 10mm Sq bar rod @ 100 mm pitch Fixing on outer frame.NCL or Equvalent Makes
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium hardware ISI marked anodised (anodic coating not less than grade AC 15 as per IS :1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete. Tower bolts. 250x10 mm
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 15 as per IS :1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Al. hanging floor door stopper. Twin rubber stopper
Supply and fixing of pre-painted steel casement/ open able windows base steel as per IS 513 of - 0.58 mm thick 'D quality, galvanized as per IS 277, finish painted with a polyester paint, The section for external frame should be of 33 x 57 mm. Accessories: Glass holding flanges made of polypropylene. Sections are to be cut to length, mitre joined with corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding screws. 4mm pin head glass
SUB HEAD - IX : ROOFING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile confirming to ISO 5 (class 100) specifications
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Terrace/ Roof Slab Waterproofing Approved makes : Pidilite/ Fosroc/ MYK
Surface Preparation Clean the surface using wire brush or Blower and ensure the surface is free from laitance, loose or friable materials, debris etc. Ensure the substrate has properly cured and the concrete is profile free, no ridges or troughs. Sloped Screed in CC 1:2:4 as per 100 slope to be laid Construction Joint/ Crack Treatment: All Construction / Cold Joints in side walls shall be opened in V-groove size to maximum depth of 25mm, Fixing PVC nozzle between 1m centre to center and injecting Cement, Water, Expansive Plasticizing Admixture & grouting Aid for Cementitious Grout at a dosage of 225 gm/ Bag of Cement and Modified Styrene Butadiene Latex at a dosage of 1 kg/ Bag of Cement Slurry through proper grouting pump/ Machine and Sealing the joints with Polymer Modified Mortar using Cement : Sand (1:4) and Modified Styrene Butadiene Latex @ 2 kg per Bag of Cement. After Grouting, the nozzles must be cut and levelled with the raft (Only Slab plan area will be measured for Payment)
ANGLE FILLET: All the junctions of floor and vertical sides of slab and sunken portions shall be provided with Cement : Sand Screed based angle fillet of 75mm x 75mm including reinforcing the coating with application og base coat of two component acrylic cementitious coating system & sticking 40 gem fibre-mesh & applying scond coat of two component acryic cementitious coating system on angle fillets. The screed shall be admixed with Modified Styrene Butadiene Latex of dosage 1 kg/ 50 kg Cement bag, to provide strength and water resistance to water leakage
Providing and Applying Hybrid Urethane Elastomeric Coating for roof which is two-component, high-strength, fast-curing, UV resistant hybrid urethane elastomeric waterproof topcoat designed for superior waterproofing in new construction projects. It is a prime-less coating with excellent adhesion to various substrates and can be applied on wet and damp surfaces.Roof Top coat consumption being - 1.60 Kg/m2/2-3 coats. The following are the technical parameters: 1. UV Resistance – 2000 Hrs 2. Neat film Elongation at Break 200% as per ASTM D 2370 3. Shore A 85 as per ASTM D2240 4. Dynamic Crack Bridging Ability @ -26"C' for 10 Cycle @ rate of 3.2 mm/ hrs Pass, No Crack or Pinholes observed as per ASTM C 1305-2016 5. Pull off Adhesion on concrete 1.7 N/mm2 as per ASTM D 7234 6. Peel Adhesion to Concrete under wet Condition -24 Hrs. – 11.4 N as per ASTM C 794. Please note that the coating shall be provided to the full Parapet Walls too.
Bore Packing: All the pipes to placed / inserted in the core cut areas, shall be wrapped around by a twin sided adhesive tape and placed appropriately to be grouted around the cut bores. Grouting the gaps between the pipe and the core cutting by an expansive cementitious grout- ready to use, non-shrink, free-flowing and high strength cementitious grout, that shall be poured into the gaps after fixing in place an effective leak-free shuttering.
50mm Dia
75mm Dia
90mm Dia
125mm Dia
160mm Dia
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes of 150mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 150mm Bend 87.5°
150mm Shoe (Plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 150mm
PIT Water Proofing Approved makes : Pidilite/ Fosroc/ MYK
Below Ground/ Raft Waterproofing - Pre Applied Fully Bonded HDPE Membrane
Surface Preparation: Cleaning the surfaces with Wire brush/blower, so as to make the surface ready for the application of membrane.
Supplying and installing of not less than 1.2 mm composite thick self adhesive HDPE membrane, which is preformed HDPE fully bonded membrane that bonds to the wet concrete cast on the membrane, having the following properties 1.Puncture resistance of 800 N (as per ASTM E 154) 2.Tensile Strength of HDPE Without Adhesive (Film) of 21 Mpa (as per ASTM D 412 Modified) 3.Elongation >400% (as per ASTM D 412 Modified) 4.Peel Adhesion to Concrete of 880 N/m (as per ASTM D 903) 5.Dimensional Stability of 0.5% (as per ASTM D 1204) 6.Hydrostatic head resistance not less than 60 m head of water (ASTM D 5385-6). The Size of Each Membrane Sheet of HDPE Membrane should be 2.4 meter X 20 meter or 2 meter X 20 meter. The system should be fully bonded to the RCC and consists of highly resilient HDPE film, self adhesive polymer layer and a trafficable granular layer. The membrane shall have minimum of 75 mm side and end laps which shall be sealed with double sided adhesive tape. All vertical surfaces will be fixed using prefixed gaskets/shot gun..etc. complete as per manufactures specification. The work shall be executed by manufacturer's In - House Application Wings only with 10 years warranty by Manufacturer.
External Side Waterproofing/ Retaining Walls using SBS mebrane: SBS modified self adhesive cold applied waterproofing membrane based on a tropical grade of polymer modified bitumen(positive side of rcc wall)
Surface Preparation: Cleaning the surfaces with Wire brush/blower, so as to make the surface ready for the application of membrane.
Providing and laying of 1.5 mm thick SBS modified self adhesive cold applied waterproofing membrane topped with impervious ,non- perforated HDPE cross laminated film, confirming to the requirements of ASTM D 5147 for thickness with a puncture resistance of >200 N as per ASTM E154 including cleaning the surface, priming the surface with Torchshield at the rate of 0.25 l/Sqm. The membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc.. complete, with 10 years warranty for waterproofing performance to be given by the principal manufacturer for both supply and application.
Providing & Fixing of 8mm thick dimple board of compressive strength not less than 200kN/m2
Termination: Supplying and applying aluminium strip flashing with fasteners at the top and sealing the joints with hybrid sealant like one component moisture curing, low modulus silyl modified polymer sealant.
Tie Rod Hole Treatment - Internal & External Sides
Clean the surface with wire brush, Provide and Apply ready to use, non-shrink, free-flowing and high strength cementitious grout/ ready to use dual shrinkage compensated dry powder, requiring only the addition of clean water to produce a free flowing dimensionally stable micro concrete/ ready-to-use dimensionally stable cementitious fibre reinforced structural grade repair mortar.
Construction Joint Treatment - Internal & External Sides
Construction Joint Trearment: All construction Joints in the retaining wall shall be opened in V-groove size to maximum depth of 15mm, clean the exposed area with air blowing machine and seal the joints with polymer modified mortar using Cement : Sand = 1 : 4 and Modified Styrene Butadiene Latex @ 2 kg per Bag of cement and level with the surface.
Dry Well Waterproofing- 7.5 metre of Diameter, 17 metre Deep, Below NGL: Internal Side (Negative Side)
Surface Preparation: Cleaning the surfaces with Wire brushing and washing the treatment receiving surface area with water, so as to make the surface totally dust free to receive the treatment.
Angle Fillet: All the junctions of floor and vertical sides shall be provided with cement-sand screed based angle fillet of 75 mm X 75 mm. The screed shall be admixed with Modified Styrene Butadiene Latex (Dosage -1 KG/ 50 kg cement bag), that will provide strength and resistance to water leakage.
Priming: Providing and applying Two component solvent free flexible Polyurethane primer, which shall be mixed well and applied using roller/brush over the prepared RCC surface in one - two coats with coverage of 200 gm/sqm. Self-curing time of 3-12 hours depends upon the climatic conditions. (Ensure the primed surface is tacky condition before application of main coat) Waterproofing coating: On the primed surface, providing and applying 2 coats of two-component, solvent-free, thixotropic coating, based on high quality elastomeric polyurethane resins after mixing the two components. It shall be applied in two coats by roller only @1.4 kg/sqm (0.5 kg/sqm in 1st coat and remaining in the second coat). Allow the coating to cure for 3-5 days fully before conducting water ponding test for 24 hours. Gap between the two coats application shall not exceed 12 hours. The coating shall have the following technical parameters: 1. Specific gravity 1.2 2. Solid content of 100% 3. Elongation of 100% 4. Ttensile strength >10 MPa as per ASTM D412 5. Hardness >40 as per ASTM D2240 6. Hydrostatic pressure resistance of 5 bar as per EN12390 7. Adhesion to concrete >1.5 MPa as per ASTM D7234 8. Water absorption < 0.5% as per ASTM D570 9. Certified by CFTRI as per 21 CFR 175- 300 of US -FDA for potable water contact all as per manufacturer's specification, etc .complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
SUB HEAD-X - : SANITARY INSTALLATIONS
SANITARY FIXTURES ,FITTINGS & INTERNAL SEWAGE
Providing and fixing of wall Hung EWC, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with pp soft close seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap,pvc connections etc complete in all respect as per directions of Engineer-in-Charge. E.W.C : Wall Hung Jaquar 350X500X335 mm, Make : Jaquar, Model No.: ECS-WHT-955SPP, Hindware:92024-SW Concealed Cistern :Single piece slim concealed cistern body Model no: JCS-WHT-2400S, Hindware:517444 Flush Plate : Control plate continental prime Angular stop cock : AQT-CHR-3057P Jaqaur,F850077CP Hindware
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,pvc waste pipe connections, cutting and making good the walls wherever required : White Vitreous China Wash basin size 545X400X205 mm mm with a single 15 mm C.P. brass pillar taps Wash Basin : Wash Basin 545X400X205 mm, Make : Jaquar, Model No.: ECS-WHT-801,Hindware :10049. Pillar cock , Make : JAQUAR, Model No.:STE-CHR-107001,Hindware :F650001. Waste Coupling: Waste coupling (full thread) 32 mm, Model No.: ALE-CHR-544NHT Make:Jaquar,Hindware F850002CP. Bottle Trap : Bottle trap 300 mm (12”), Model No.: ALE-CHR-773ML 300X125, Make:Jaquar,Hindware F850072CP. Angular stop cock : AQT-CHR-3057P Jaqaur,F850077CP Hindware
Providing and Fxing white vitreous china sensor operated urinal of approx. size 385x325x635 mm having pre & post fushing with water(250 ml & 500 ml consumpton), having water inlet back side, including fixing on wall with suitable brackets , waste coupling & bottle trap etc complete in all respect as per directions of Engineer-in-Charge. Urinal : Whiz Regular Urinal - White, Model No.: URS-WHT-13253N, Make :Jaquar,Hindware : 96014 Urinal Sensor : Electronic flushing system (DC), Model No.: SNR-STL-51087, Make : Jaquar,Hindware:F860083CP. Sensotronic Concealed Type Flushing Valve for Urinal Complete Set with Installation Box with Control Cock. Waste coupling : ALE-CHR-544NHT Jaquar ,Hindware F850002CP. Bottle Trap :ALE-CHR-773ML300X19 jaquar,Hindware F850072CP.
Providing and fixing white vitreous china half stall urinal of 355x340x535 mm with auto closing flush and fittings, CI brackets of standard size, CP brass flush pipe and spreader with unions and clamps, CP brass waste coupling and CP brass bottle trap of 40 mm dia., painting of all neccessary fittings and complete fiished item of work. Urinal ;URS-WHT-13261 Jaquar Flush valve :PRS-CHR-077Jaquar Bottle trap :ALE-CHR-773ML300X19 jaquar ,Hindware F850072CP. Waste Coupling: ALE-CHR-544NHT Jaquar,Hindware F850002CP. Angular stop cock : AQT-CHR-3057P Jaqaur,F850077CP Hindware
Supply and fixing of 15 mm CP Health faucet CUM bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. Health Faucet : Hand shower health faucet ABS Body ALE-CHR-583, Two Way Bib Cock : Agate Pro Two way bib cock, Model No.: TQT-512ANKN, Make : Jaquar , Hindware :F650004CP.
Supplying and fixing in position best quality and approved make CP brass Toilet paper holder of standard size with necessary CP screws and washers fixed to wall including cutting wall, fixing and making good the surface etc., complete all as specified and Toilet Paper Holder : Paper Holder, Model No.: AEC-1151N, Make : Jaquar, Hindware F102009CP
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls and complete finished item ofthe work. wherever required : Kitchen sink with drain board Kitchen Sink :B4511101M, Make : CERA Bottle Trap : Bottle trap 300 mm (12”), Model No.: ALE-CHR-773ML300X125, Make: Jaquar,Hindware F850072CP. Sink Cock:Cock, Model No.: STE-CHR-107347, Make : Jaquar:Hindware : F650026CP. Angular stop cock : AQT-CHR-3057P Jaqaur,F850077CP Hindware
Providing & fixing in of SS Safety Shower & Eye wash conforming to IS -10592. the twin fountaine had shall give, Water inlet connection 1-¼” NB single inlet connection for both shower & eye wash, Water outlet connection – 1-¼” NB, Head shower discharge rate – 84-92 lpm, Push to open valve - connects unit to uninterruptible water supply, Eye wash discharge rate – 30 lpm, Base plate - to hold the shower structure in a stable position (size-180mm), With foot pedal for hands free operation to supply and control water flow through eye wash head. This also includes fitting the combined unit. Supply of 1092 model Eye/Face wash and shower operate independently by Foot pedal and pull rod - ISI Marked M.O.C - G.I pipe with PVC accessories
Providing and fixing in position best Indian make C.P. brass twin way Coat hooks fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the walls etc. Twin Way Coat Hook : Robe Hook, Model No.: AEC1161, Make : Jaquar,Hindware : F880004CP.
Providing & fixing C.P. brass towel ring fixed to rawl plug with C.P. brass screws. Towel Ring : Model No.: AEC-1121N, Make : Jaquar,Hindware : F102003
Providing and fixing electrical hand dryer, fully automatic type, cover shall be fabricated in extra heavy duty 18 gauge type 304 SS with exposed surfaces stainless steel finished, the unit shall deliver not less than 71 l/sec of hot air and electrical rating shall be 240 V/ 1 phase/ 50 cycles. Hand Dryer : Bolt touch-free infrared hand dryer with 1150W rated power & carbon brush motor, Material : 304 Stainless Steel, Finish : Stainless Steel Finish, Model No.: HDR-SSF-AK2803D, Make : JAQUAR,Dolphy
Providing and fixing 630x445mm swivel mirror of rectangular shsape beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Model no :AKP-CHR-35795 MAKE: Jaquar
Supply & Fixing of wall hung Urinal partion having curved shape with frosted glass of size 8mm/10mm thick 450*900mm & complete finished item of work as per instruction of enginneer/In charge .make: Jaquar code- JSE-CHR-810UC450X
Providing and fixing PVC/SWG Pipes conform to IS:13592-1992 of Type-B for sewage Disposal and Vent pipes Inclduing fixing of Clamps For every 1.5mt interval all necessary fittings likes bends, door bends, couplers, o Rings ,U clamps ,GI slotted clamps ,Pasting solvent etc., complete finished item of work.
75mm dia PVC/SWG Single socket -SWR TYPE B
Providing and fixing PVC/SWG Pipes conform to IS:13592-1992 of Type-B for sewage Disposal and Vent pipes Inclduing fixing of Clamps For every 1.5mt interval all necessary fittings likes bends, door bends, couplers, o Rings ,U clamps ,GI slotted clamps ,Pasting solvent etc., complete finished item of work.
110mm dia PVC/SWG Single socket -SWR TYPE B
Providing & fixing Upvc P Trap of 110 X 110 mm diameter with Height riser/ necessary distance piece for wash basin/ sink drain connection with Futura cockroach trap - square flat cut, Satin-matt finish - 150mm x 150mm, making necessary slab/ wall/ beam holes and cutting walls, etc. complete.
Providing & fixing Upvc P Trap of 110 X 110 mm diameter with Height riser/ necessary distance piece for urinal drain connection with Futura floor clean out square cut 150mm- Satin, making necessary slab/ wall/ beam holes and cutting walls, etc. complete.
SUB HEAD-XI: INTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal dia. Pipes
20 mm nominal dia. Pipes
25 mm nominal dia. Pipes
32 mm nominal dia. Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia. Pipes
25 mm nominal dia. Pipes
32 mm nominal dia. Pipes
40 mm nominal dia. Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SUB HEAD-XII :- HVAC
HVAC SYSTEM
All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over
All the equipments shall be five star rated only
All Techincal data sheet & drawing shall be submitted and get approved by department before supply
All equipment factory inspection shall be carried out by department
First prefers as per BOQ followed by Techincal specification
CHILLING PLANT SYSTEM
Supply, Installation, Testing, commissioning and handing over of Air cooled Variable Frequency Driven Screw comperssor plant of TR Actual capacity and above having a minimum COP of 3.5 and compliant to (AHRI/EUROVENT Certified) each comprising of : Semi Hermetic sealed screw compressors with suitable Variable Frequency Drive along with necessary refrigerant piping and controls. The Screw chilling unit consists of Semi Hermetic sealed compressors, shell and tube Flooded chiller, air cooled condenser coil with Blue coated fins, low noise fans with motor and drive, panel etc. The system shall be complete with first charge of refrigerant & oil, refrigerant piping, HP/LP cut out, thermostatic expansion valve, flow switch and controls.The chiller shall be compatible to third party BMS with BACnet / Mod bus Protocol. The refrigerant shall be R-407C / R-134A. The entire assembly of the unit shall be mounted on a rigid MS base frame. The chiller shall be provided with Victaulic couplings/ Flanged connectors for connecting the chilled waterlines. The air cooled condenser complete with copper condenser coil with aluminium fins, coil guard, condenser fans & motors , inter connecting refrigerant piping, fittings, suction line insulation etc. The entire chiller package shall be mounted on a rigid common base frame. The base frame shall be provided with two coats of anti corrosive primer and two coats of epoxy paint. The chillers shall be mounted on a MS framed structure with necessary vibration mount. The compressors shall be provided with acoustic jackets . The dB(A) of the chillers with acoutic jackets shall not exceed 78dB(A) at 1 Mtr Distance. The microprocessor panel Shall be BMS compitable and has Backnet/IP protocol for sharing the chillers information/ data with BMS System. Motor shall be suitable for 415+/-10 V ,50 cycles, 3 phase, 4 wire AC supply. The chillers shall be compitable to Bacnet/IP protocol. The chillers shall operate on varying part loads in stepless mechnism ( infinite ) from 10% to 100% with capacity control slide valve mechanism. The Chiller shall meet Min. COP, EER, IPLV as per ECBC & ASHRAE 90.1 -2010(S) standards requirement
a) semi hermetic Mutilple Screw compressors with motor and Frequency drive one per each compressor
b) Air Cooled Condenser with pre cooling arrangement and other accessories
c) Flooded type shell and tube Chiller with accessories
d) Steel structure for assembling/mounting the equipment, finished with powder coated painting, spring type vibration isolators for installing the equipment on foundation
e) Control panel incorporating all safety functions including HP & LP cutouts, single phase preventor, internal control wiring for sequential operation, contactors for sensing flow through leaving chilled water control, compressor & Thermostatic expansion valve modulation with automatic capacity/load limiting devices
f) Inter connected refrigerant piping with safety controls viz. Liquid line solenoid valves, HP/LP controls
g) Full charge of refrigerant R134A/R407C and Oil
h) Unit Mounted starter panel comprising of disconnect switches, soft starter and related accessories etc complete.
j) Factory installed shell & Tube chiller with suitable insulation and covered with Alumiumim Cladding.
Chiller unit including wih flexible bellows,viberation pads, suitable for working pressure of PN16 etc
Pressure drop not to exceed 20 feet
Evaporator Fouling Factor - 0.0005 FPS
IKW/TR at above design conditions - not more then 1.25
Chiller with standard with Victaulic coupling, CU-AL condenser, Spring vibration isolators, Flanged connectors, - Rating chart attached.
1) IKW/TR should be inclusive of condenser fans
2) Make of compressor should be same as OEM
COP @ AHRI condition should be as per ECBC + ( Plus)
The chilling machine as described above shall be in line with specifications
The price of Air Cooled chilling machine including with loading, unloading, lifting & shifting etc at site positioning.
The chiller shall be designed based on
Ambient : 45º C
Chiller inlet : 11º C
Chiller Outlet : 6º C
100TR Chiller (2W+1S)
54TR Chiller (2W+1S)
CHILLED WATER PRIMARY PUMPS
The pumps shall be single-stage, Close-coupled, in-line suction and discharge ports of identical diameter with back-pull-out design. Hence, the rotating unit can be removed and serviced without disconnecting the suction and discharge piping. The liquid cavity shall be sealed off at the pump shaft by an internally-flushed mechanical seal with carbon seal seat and ceramic / silicon carbide seal head. Pump spiral volute casing shall be of in-line design robust construction with integrally-cast base at bottom in order to transmit pipe load to the base and foundation Pump casing shall be EN-GJL-250 Grey Cast Iron with CED Coating and capable of withstanding to the maximum pressure developed by the pump. The pump casing shall be fitted with a renewable type case wear ring to minimize abrasive and corrosive wear to the casing. The case wear ring shall be of the radial type, press fitted in to the casing. Casing wear ring shall be lead free bronze CuSn10/brass.The impeller shall be lead free cast Bronze (CuSn10 which is according to EN 1982) enclosed type with smooth surface finish for minimum frictional loss.Bearings shall be so designed as to take the necessary radial load as well as the net hydraulic axial thrust. All impellers shall be dynamically balanced according to ISO 1940-1: Grade G6.3 and hydraulically balanced to increase the life of motor bearings and shaft seal by minimizing axial loads. Pump shaft shall be Austenitic stainless steels according to EN 1.4301 / AISI 304 shaft.Totally enclosed fan-cooled motors with main dimensions according to IEC standards. Electrical tolerances are to IEC 60034. Motor shall be high-efficient type IE3. Motor shall be to with IP 55 enclosure. The class of insulation shall be F with temperature rise limited to Class B. Motor shall be suitable for operation on a 415 V (± 10% variation), 50Hz ± 5%, 2 Pole, 3phase AC supply. Motor shall be suitable for both DOL and / or STAR/DELTA starting. Motor should be of variable frequency drive compatible without derating. Motors with kW rating, 75kW and above shall have compulsory Insulated Bearings fitted on the NDE (non-drive end). Above 50Hz operation is not allowable to achive the duty flow and head.Pump shall come in assembled condition with the motor, base frame, couping, coupling guard as a set. unit including wih flexiable bellows,viberation pads, suitable for working pressure .The pump(s) vibration limits shall conform to ISO 5199. Maximum sound pressure level [dB(A)] of the pump driver shall be as per ISO 3743. All external and exposed cast iron parts of pumps shall have an epoxy-based coating made in a cathodic electro-deposition (CED) process both externally & internally. The pump(s) Duty Flow to BEP Flow ratio should be lies within 5%. The pumps shall be factory manufactured, assembled and hydrostatically tested in an ISO 9001 approved facility as per ISO 9906:2012. including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be as per specifications and approved drawings.(Motor Make-Siemens/Grundfos Brand/Veg)as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted Spring vibration isolators with flexible bellows, Victaulic coupling, Flanged connectors necessary vibration isolators. Each Pump capacity shall be as per specifications and approved drawings.
(consider head is tentative actual calculate as per site conditions)
Chilled Water Primary Pumps 3No's (2W+1S) 240USGPM at 28Meters Head of wc.
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:
Supply, installation, testing and commissioning of variable primary pump PLC based control panel suitable for 3 Pumps (2W+1S) consisting of variable speed secondary chilled water pumps as per above with matching VFDs ( (Make-Danfoss/Grundfos/Siemens)) , one PLC based pump controller with parallel pumping software duly installed. Pump logic controller inbuilt with Variable frequency drives are not accepted. Logic controller should be external to the drives used in the system.PLC Controller shall have programs to safeguard the system against the following conditions Pump flow surges, System Hunting, End of curve protection. Pump Controller shall have program function to accept the pump curve data for optimizing the system performance in terms of energy consumption. PLC should be suitable for 2 Nos analogue input from flow meter to synchronise with the Variable secondary Pump flow and also maintain the minimum flow rate required for the chiller. to ensure unit responsibility. Should be compatible with Modbus.Controller shall be IP 55 protected and shall come with 2 Nos. DPTs. Control panel shall be with individual feeder_with Bypass arrangement. 1 No. of DPT accross each chiller shall be considered to maintan the minimum flow.
Chilled Water Primary Pumps 3No's (2W+1S) 129.6USGPM at 24Meters Head of wc.
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:
Supply, installation, testing and commissioning of variable primary pump PLC based control panel suitable for 3 Pumps (2W+1S) consisting of variable speed secondary chilled water pumps as per above with matching VFDs ( (Make-Danfoss/Grundfos/Siemens)) , one PLC based pump controller with parallel pumping software duly installed. Pump logic controller inbuilt with Variable frequency drives are not accepted. Logic controller should be external to the drives used in the system.PLC Controller shall have programs to safeguard the system against the following conditions Pump flow surges, System Hunting, End of curve protection. Pump Controller shall have program function to accept the pump curve data for optimizing the system performance in terms of energy consumption. PLC should be suitable for 2 Nos analogue input from flow meter to synchronise with the Variable secondary Pump flow and also maintain the minimum flow rate required for the chiller. to ensure unit responsibility. Should be compatible with Modbus.Controller shall be IP 55 protected and shall come with 2 Nos. DPTs. Control panel shall be with individual feeder_with Bypass arrangement.1 No. of DPT accross each chiller shall be considered to maintan the minimum flow.
CHILLED WATER SECONDARY PUMPS
The pumps shall be single-stage, Close-coupled, in-line suction and discharge ports of identical diameter with back-pull-out design. Hence, the rotating unit can be removed and serviced without disconnecting the suction and discharge piping. The liquid cavity shall be sealed off at the pump shaft by an internally-flushed mechanical seal with carbon seal seat and ceramic / silicon carbide seal head.Pump spiral volute casing shall be of in-line design robust construction with integrally-cast base at bottom in order to transmit pipe load to the base and foundation Pump casing shall be EN-GJL-250 Grey Cast Iron with CED Coating and capable of withstanding to the maximum pressure developed by the pump. The pump casing shall be fitted with a renewable type case wear ring to minimize abrasive and corrosive wear to the casing. The case wear ring shall be of the radial type, press fitted in to the casing. Casing wear ring shall be lead free bronze CuSn10/brass.The impeller shall be lead free cast Bronze (CuSn10 which is according to EN 1982) enclosed type with smooth surface finish for minimum frictional loss.Bearings shall be so designed as to take the necessary radial load as well as the net hydraulic axial thrust. All impellers shall be dynamically balanced according to ISO 1940-1: Grade G6.3 and hydraulically balanced to increase the life of motor bearings and shaft seal by minimizing axial loads. Pump shaft shall be Austenitic stainless steels according to EN 1.4301 / AISI 304 shaft.Totally enclosed fan-cooled motors with main dimensions according to IEC standards. Electrical tolerances are to IEC 60034. Motor shall be high-efficient type IE3. Motor shall be to with IP 55 enclosure. The class of insulation shall be F with temperature rise limited to Class B. Motor shall be suitable for operation on a 415 V (± 10% variation), 50Hz ± 5%, 2 Pole, 3phase AC supply. Motor shall be suitable for both DOL and / or STAR/DELTA starting. Motor should be of variable frequency drive compatible without derating. Motors with kW rating, 75kW and above shall have compulsory Insulated Bearings fitted on the NDE (non-drive end). Above 50Hz operation is not allowable to achive the duty flow and head.Pump shall come in assembled condition with the motor, base frame, couping, coupling guard as a set. unit including wih flexiable bellows,viberation pads, suitable for working pressure The pump(s) vibration limits shall conform to ISO 5199. Maximum sound pressure level [dB(A)] of the pump driver shall be as per ISO 3743. All external and exposed cast iron parts of pumps shall have an epoxy-based coating made in a cathodic electro-deposition (CED) process both externally & internally. The pump(s) Duty Flow to BEP Flow ratio should be lies within 5%. The pumps shall be factory manufactured, assembled and hydrostatically tested in an ISO 9001 approved facility as per ISO 9906:2012. (Motor Make-Siemens/Grundfos Brand/Veg), as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted Spring vibration isolators with flexible bellows, Victaulic coupling, Flanged connectors necessary vibration isolators. Each Pump capacity shall be as per specifications and approved drawings.
(consider head is tentative actual calculate as per site conditions)
Chilled Water Secondary Pumps 3No's(2W+1S) 240USGPM at 36Meters Head of wc.
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:
Supply, installation, testing and commissioning of variable secondary pump control panel suitable for 3 Pumps (2W+1S) consisting of variable speed secondary chilled water pumps as per above with matching VFDs ( (Make-Danfoss/Grundfos/Siemens)) , one dedicated microprocessor based pump controller with parallel pumping software duly installed. Multi Pump Controller shall be listed by and bear the label of Underwriter’s Laboratory Inc (UL). Pump logic controller inbuilt with Variable frequency drives are not accepted. Logic controller should be external to the drives used in the system. Multi Pump Controller shall have programs to safeguard the system against the following conditions Pump flow surges, System Hunting, End of curve protection. Multi Pump Controller shall have program function to accept the pump curve data for optimizing the system performance in terms of energy consumption. Multi Pump Controller shall be capable of controlling up to six pumps in parallel, and have a display screen size of minimum 320 pixels x 240 pixesl VGA display with backlight..The entire system along with chilled water pumps as described must be sourced from pump supplier only, to ensure unit responsibility. Should be compatible with Modbus.Controller shall be IP 55 protected and shall come with 2 Nos. DPTs. Control panel shall be with individual feeder_with Bypass arrangement.
Chilled Water Secondary Pumps 3No's(2W+1S) 129.6USGPM at 30Meters Head of wc.
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:
Supply, installation, testing and commissioning of variable secondary pump control panel suitable for 3 Pumps (2W+1S) consisting of variable speed secondary chilled water pumps as per above with matching VFDs (Make-Danfoss/Grundfos/Siemens)) , one dedicated microprocessor based pump controller with parallel pumping software duly installed. Multi Pump Controller shall be listed by and bear the label of Underwriter’s Laboratory Inc (UL). Pump logic controller inbuilt with Variable frequency drives are not accepted. Logic controller should be external to the drives used in the system. Multi Pump Controller shall have programs to safeguard the system against the following conditions Pump flow surges, System Hunting, End of curve protection. Multi Pump Controller shall have program function to accept the pump curve data for optimizing the system performance in terms of energy consumption. Multi Pump Controller shall be capable of controlling up to six pumps in parallel, and have a display screen size of minimum 320 pixels x 240 pixesl VGA display with backlight..The entire system along with chilled water pumps as described must be sourced from pump supplier only, to ensure unit responsibility. Should be compatible with Modbus.Controller shall be IP 55 protected and shall come with 2 Nos. DPTs. Control panel shall be with individual feeder_with Bypass arrangement.
Closed Type Expansion Tank: 1000 Litres Closed Type Expansion Tank-Supply, installation, testing & commissioning ASME certified Expansion Tank and Air Separator with auto Airvent, insulation, necesaary pneumatic devices and Pressurization Unit with two pumps (1W+1S), 2CMH, 25mWC, PN 16, pressure switch, Safety Valve, Gas Charging pipe with 3 nos. Adaptors & other accessories. The Control system should also be include in the cost as per following. Expansion Tank and Air Separator should be sourced from manufacturer same as pump make for unit resposibility. Non ASME Expansion Tank and Air Separator should be suitable for minimum working pressure for 235 PSI.Total Volume to be checked by vendor as per site conditions.The Expansion Tank characteristic shall be as follows:
Microbubble AIR & DIRT SEPERATOR
Supply, Installation Testing and Commissioning of In-line Air & Dirt Separator. removing of free air, bubbles and microbubbles in combination with separation and removal of dirt particles within chilled water system.The acceptable design shall incorporate a separating element to force water into tranquillity zones for air and dirt removal. A nozzle shall force de-aerated water into the main flow to divert contaminated water through the separating element. A high capacity, conical brass automatic air vent shall be installed on the top of the vessel for air discharge. Drain valve for removal of floating debris and dirt. Heavier than water dirt particles shall be removed via a blow down valve on the base of the vessel whilst ferrous particles down to 4 µm shall be captured by a magnetic device in the lower part of the vessel.Manufactured and designed in accordance with European Pressure Equipment Directive The Microbubble Air and Dirt Separator shall be sized appropriate to the maximum operating pressure and flow velocity of the system. as per the specifications and approved drawings.
125 mm dia
150 mm dia
CHILLER WATER PIPING
Supply, Installation, Testing and Commissioning of MS 'C' Class as per IS -1239 chilled water pipe with fittings, flanges, valves,reducers ,sockets for probe meter, support hangers with vibration isolation hanger including PUR/PIR inserted self closing insulated single piece pipe supports, including painting ,etc. with insulation of 32mm thick for piping with closed cell elastrometric nitrile rubber of density 43 Kg/m3, Thermal conductivity not exceeding 0.035 W/M°K Class 1, fire performance to pass class 1 as per BS 476 part 6& class O as per BS 476 part 7 & use recommended adhesive / SR Fevicol 505 grade and Insulation covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make and protective coating of starbond 30-36 finished with exposed area's 26 g aluminium cladding as per the specifications and approved drawings.
150 mm dia (32 mm Thick Insulation)
125 mm dia (32 mm Thick Insulation)
100 mm dia (32 mm Thick Insulation)
80 mm dia (32 mm Thick Insulation)
65 mm dia (32 mm Thick Insulation)
50 mm dia (32 mm Thick Insulation)
40 mm dia (32 mm Thick Insulation)
Supply, fixing, testing and commissioning of the following valves PN 16 Rating as per engineering standards Cast Iron Body / Gun metal body with 32mm thickness Nitrile rubber insulation as per specifications.(For Chilled water system) with exposed area's 26 g aluminium cladding as per the specifications and approved drawings.
Butterfly Valves
150mm dia
125mm dia
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
Balancing Valves
150mm dia
125mm dia
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
Non Return Valve
100mm dia
Y' Strainers
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
2 way mixing valves with actuvator
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
Supplying, installing, testing and commissioning of Electrical Hot Water generator of vertical/ horizontal construction equipped with sufficient number of flanges and electrical immersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fibreglass Claded with 0.63mm aluminium sheet. The hot water generator shall be equipped with all automatic and safety controls such as manual reset high temperature water outlet, step controller and recycling relay, ON-OFF switch, thermostats, pilot light, ‘ON’ status of individual banks, low water cut off all as per manufacturers recommendations. All basic controls and terminal shall be located in an internal control cabinet, factory wired and tested. The hot water generator shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply.The entire hot water generator and control cabinet shall be factory assembled on common base and tested, requiring only connection to services. The Working Pressure for the Hot Water Generators shall be 100 PSI. Along with all safties and protections with LED/Jewel lamp indication and relief valves complete generating hot water of minimum temp 75 Deg C and max of 90 Deg C suitable for recirculation of water as per specification
54KW Capacity
62KW Capacity
Supply, Installation, Testing, Commissioning and handling over of vertical inline multi stage pump of following capacities with required head as per the following Hotwater pumps including necessary stuffing box and suitable for operation to withstand temperature of upto 90 Deg C etc., complete. Pump shall come with CI with CED coated-Casing, SS 304-Impellers, SS 316-Shaft, Balanced Cartridge Seal with SiC vs SiC face combistion with EPDM rubber parts. Pump shall be fitted with 415V+/-10%, 50Hz+/-5%, Insulated Class-F, IP 55 Protected, Temperature Rise as per Class B Motor (Make-Innomatics_Siemens/Grundfos Brand/Veg) including necessary stuffing box and suitable for operation to withstand temperature of upto 90 Deg C etc., complete
(consider head is tentative actual calculate as per site conditions)
37.8US GPM @ 30mt head of wc and required rating motor along with Mechanical seal, drive transmission accessories and base frame etc
33.6US GPM @ 20mt head of wc and required rating motor along with Mechanical seal, drive transmission accessories and base frame etc
Supply, erection, testing and commissioning of above ground MS class 'c' ERW insulated Hot water piping complete with civil / MS supports wherever necessary, fittings and pressure testing of pipes including civil pedastals , M S supports , Insulation of piping shall be 75mm thick Rock wool covered with vapour barrier, Chicken wire mesh and 24 G Al cladding as per tender specifications for the following:
15mm dia
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
Supply, fixing, testing and commissioning of the following valves PN 10 Rating as per engineering standardsCast Iron / Gun Metal Body and specifications. (For Hot water system)
Butterfly Valves
40mm dia
50mm dia
Balancing Valves
15mm dia
20mm dia
25mm dia
40mm dia
50mm dia
Non Return Valve
50mm dia
Y' Strainers
15mm dia
20mm dia
25mm dia
40mm dia
50mm dia
AHU's / CSAHU Controls PIBCV and Three Way Modulating Valve:
Supply, Installation, Testing and commissioning of 3 Way Motorised valves with Actuator for operating at 0-10V DC supply for Hot water as per specification along with Thermostat control
15mm dia 3 way control valves
20mm dia 3 way control valves
25mm dia 3 way control valves
40mm dia 3 way control valves
Gate Valve
15mm dia
20mm dia
25mm dia
Supply , transportation , Lifting , Shifting ,installation ,testing and commissioning of SS pressure gauges, 4” dial 0-10 kg with SS Syphon & 10 mm Ball valve
Supply , transportation , Lifting , Shifting ,installation ,testing and commissioning of SS Temperature gauges, 4” dial 0-50 deg, 6” stem length with SS thermowell filled with suitable heat transfer liquid
Water flow switch with stem type sensing element probe for flow sensing.
Supply,Installation,Testing and commissioning of Auto Airvents 20mm dia
AIR HANDLING UNITS
Supply, installation, testing, commissioning and handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators
i) The Air handling unit shall comprise of fan section with Plug Fan/ Backward curved fan with limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of Chilled water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FA dampers etc. complete in all respect whether specifically spelt or not but required to complete the system works.
The entire unit casing shall be weather proof , made out of 50 mm thk. 43 Kg/ cum density double skin PUF panels. The entire assembly of the unit shall be mounted on a rigid GSS base frame. Inner skin of the panel shall be 1 mm thick GSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with chilled water coils shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . The face velocity across the filters shall not exceed 500 FPM.
The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency IE3 and with VFD compatable.
The fan shall be AMCA certified and motor shall be energy efficient IE3. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safety door interlock arrangement with motor. The unit shall be supplied with fire retardant double canvass connection between the fan out let and supply air flange.
The unit shall be supplied with an outlet flange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum.
The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass.
AHU Unit should Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensor with cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete
The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit.
Contractor to submit the Duct static pressure report before procuring the AHUs.
AHU unit including complete kit which required for integration between ODU & AHU Cooling Coil unit.
The AHU shall be interloked with digital temp. & RH controller
AHU1 - 56 TR capacity , total air qty 22400 cfm, 65mm Static pressure with suitable High efficency motor ,44.8sqft area of 6 row Chilled water coil,2 row Hot water coil
AHU2 -16TR capacity , total air qty 6400 cfm, 65mm Static pressure with suitable High efficency motor, 12.8sqft area of 6 row Chilled water coil,2 row Hot water coil
AHU3 -48TR capacity , total air qty 19200cfm, 65mm Static pressure with suitable High efficency motor, 38.4sqft area of 6 row Chilled water coil,2 row Hot water coil
AHU4 -18TR capacity , total air qty 7200cfm, 65mm Static pressure with suitable High efficency motor, 14.4sqft area of 6 row Chilled water coil,2 row Hot water coil
AHU5 -20TR capacity , total air qty 8000cfm, 65mm Static pressure with suitable High efficency motor, 16sqft area of 6 row Chilled water coil,2 row Hot water coil
CEILING SUSPENDED AIR HANDLING UNIT
Ceiling Suspended Air handling unit shall comprise of fan section with Plug Fan/ Backward curved fan with limit load characteristics , spark proof fan of the fan mounted on the scroll and not on the casing, coil section comprising of Chilled water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron filters,mixing box along with RA and FA dampers etc. complete in all respect whether specifically spelt or not but required to complete the system works.
The entire unit casing shall be weather proof , made out of 50 mm thk. 40 Kg/ cum density double skin PUF panels. The entire assembly of the unit shall be mounted on a rigid GSS base frame. Inner skin of the panel shall be 0.8 mm thick GSS plain and the outer skin shall be with 0.8 mm thk. Pre plasticized powder coated. The chilled water and hot water coils shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . The face velocity across the filters shall not exceed 500 FPM.
The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring mounts to avoid vibration transmission to the base of the unit. The motor shall be efficient IE3 and with VFD compatable.
The fan shall be AMCA certified and motor shall be energy efficient IE3. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safety door interlock arrangement with motor. The unit shall be supplied with fire retardant double canvass connection between the fan out let and supply air flange.
The unit shall be supplied with an outlet flange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum.
The scope includes one set of commissioning filters along with the unit,VFD & Starter panel with Bypass.
CSAHU Unit should Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensor with cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete
The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit.
Contractor to submit the Duct static pressure report before procuring the CSAHUs.
CSAHU unit including complete kit which required for integration between ODU & AHU Cooling Coil unit.
The CSAHU shall be interloked with digital temp. & RH controller
CSAHU1- 8.0 TR capacity , total air qty 3200 cfm, 65mm Static pressure with suitable High efficency motor ,6.4 sqft area of 6 row Chilled water coil, 2 row Hot water coil
VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV)
Supply, Installation, Testing & Commissioning & Handing over of the following:
HIGH SIDE VRF/VRV EQUIPMENT
VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant
Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning system unit suitable for cooling mode having all hermetically sealed inverted type scroll compressor as per OEM comprising of High efficiency heat transfer Cooling Coil suitable for Environment friendly R410 are frigerant, Aircooled propeller type condenser fan with DC motor drive, interconnecting piping, suction line insulation etc., Micro-process or control panel suitable for automatic operation, Highspeed calculation invertercontrol, active oil control mechanism
The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage Strip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal.
All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint.
Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s), special acrylprecoated heatexchanger, low noise condenser fan, auto check function for connection error, autoaddress & unit Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV/VRF vendorscope. (ODU Location & Capacity mentioned below). Shifting of Outdoor units from GF to repective location is part of VRF/VRV vendor scope. ODUs shall have service valve station for easy operations and monitoring of system
All VRV units should be compatible for third party BMS integration. necessary integrator should be consider in part HVAC VRF/VRV vendorscope (Bacnetover MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement.
Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration
Installation and pressure testing with nitrogen Gas,Vaccumising including all consumablesforallsystemshall be part of scope of supply (Pre commissioning )
First Filling, testing, commissioning including topping up of R410 A Refrigerant Gas.
Factory Test certificates to be shared with the units
Testing tools and instruments of approved make and required quantity to be maintained by Contractor
Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations
Central remote controller should be considered and provided along with VRF/VRV units
With all necessary accessories including vibration insolation i.e fixing etc complete.
Lifting, shifting and positioning of VRF/VRV System as per design location
Outdoor unit suitable for cooling only mode having all hermetically sealed inverted type scroll compressor, microprocessor based controller.
The unit shall be deliver the rate capacity at AHRI conditions and work even at 50DegC ambient temperature with out tripping
The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated
Outdoor Unit (ODU) : Cooling Capacity : 68HP
Outdoor Unit (ODU) : Cooling Capacity : 56HP
Outdoor Unit (ODU) : Cooling Capacity : 36HP
Outdoor Unit (ODU) : Cooling Capacity : 38HP
Outdoor Unit (ODU) : Cooling Capacity : 22HP
INDOOR UNITS
Indoor Unit (IDU): Cooling Type All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete.
It should be suitable for BMS connectivity with necessary accessories.
4-WAY CASSETTE UNIT
Four way Cassette 1.6TR
Four way Cassette 2.0TR
Four way Cassette 2.6TR
Supply, installation, testing and commissioning of Schedules timer controller ODU/IDU WILL BE OPERATED IN A CYCLIC OPERATION OF 12 HOURS. 1) AT A TIME ODU 1 WITH ITS RESPECTIVE IDU WILL BE OPERATIONAL FOR 12 HOURS 2) THEN FOR NEXT 8 HOURS ODU 2 WITH ITS RESPECTIVE IDU WILL BE OPERATING 3) FOR THE REST 8 HOURS ODU 1 WILL BE OPERATING WITH ITS RESPECTIVE IDU.
DIRECT EXPANSION SYSTEM
Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with 5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only.
Hi-wall Unit 1.6TR 5 star capable of delivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5
Hi-wall Unit 2.0TR 5 star capable of delivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5
Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of split AC unit.
Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with 5 star capable Cool type cassette AC unit with ceiling mounted Single indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only.
4-Way Cassette Unit 2.0TR 5 star capable of delivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5
Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of Cassette AC unit.
INDOOR UNITS
Supply, Lifting, Shifting, Positioning, Installation, Testing and commissioning of Indoor Units consisting of 2/3 row deep DX coil, filter, blower section and drive arrangement, BLDC motor, drain pump, thermostatic control, corded remote and it should be fixed properly at the proposed location and sound levels of ductable units less than 3.2 TR should be less than 38 dB.
Type Of Units : Ducted type units
6.4TR Capacity
8.0TR Capacity
AIR HANDLING UNITS
Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators
i) The Air handling unit shall comprise of fan section with Plug Fan/ Backward curved fan with limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FA dampers etc. complete in all respect whether specifically spelt or not but required to complete the system works.
The entire unit casing shall be weather proof , made out of 50 mm thk. 43 Kg/ cum density double skin PUF panels. The entire assembly of the unit shall be mounted on a rigid GSS base frame. Inner skin of the panel shall be 1 mm thick GSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . The face velocity across the filters shall not exceed 500 FPM.
The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable.
The fan shall be AMCA certified and motor shall be energy efficient EFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safety door interlock arrangement with motor. The unit shall be supplied with fire retardant double canvass connection between the fan out let and supply air flange.
Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensor with cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete
The unit shall be supplied with an outlet flange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum.
The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB.
The AHU unit shall outdoor type with all season weather proof protection
The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit.
The unit shall be included with AHU & VFD DRIVE STATER & CONTROL PANEL
The unit shall be included with AHU CONTROLL KITS WITH CORDED REMOTES
Unit shall be ultra violet lamp to kill germs/fungus
The AHU shall be interloked with digital temp. & RH controller
AHU unit including complete kit which required for integration between VRV/VRF ODU & AHU Coil unit.
AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqft area of 6 row coil, 2 row Hot coil
AHU2 - 28TR capacity , total air qty 11200 cfm, 65mm Static pressure with suitable High efficency motor, 22.4sqft area of 6 row coil, 2 row Hot coil
Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete.
First Filling, testing & commissioning including topping up of R410 A Refrigerant Gas.
CENTRAL CONTROLLER & REMOTE SYSTEM I touch manager & bacnet (FOR VRF/VRV UNITS)
Centarl controller integrating advanced I touch manager & bacnet screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controller shall be stand-alone controller with features like visual navigation, graphical report, Multi-PC access and have the capability to program for sequential operation of indoor units etc.,complete.System should have facilities for, 1) Start, stop, 2) Temperature setting, 3) Fan speed control, 4) Mode control, 5) Group control, 6) Emergency Start and stop 7) Fire alarm system interface.
Providing & fixing of 2 Cx 1.5 sqmm Armoured copper conductor cable for control cum trans-mission between Indoor unit and Out Door Unit through PVC Conduit.
Supply, Laying, Testing and Commissioning of POWER CABLING of Copper cable for outdoor units to be suitably laid in PVC conduit as per site requirement.
4C x 10 sq.mm. (Copper) (for outdoor Units )
LOW SIDE VRV/VRF EQUIPMENT
REFRIGERANT PIPING
Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves
41.3mm OD (insulation =19 mm thick)
38.1mm OD (insulation =19 mm thick)
34.9mm OD (insulation =19 mm thick)
31.8mm OD (insulation =19 mm thick)
28.6mm OD (insulation =19 mm thick)
25.4mm OD (insulation =13 mm thick)
22.2mm OD (insulation =13 mm thick)
19.1mm OD (insulation =13 mm thick)
15.9mm OD (insulation =13 mm thick)
12.7mm OD (insulation =13 mm thick)
9.5mm OD (insulation =13 mm thick)
6.4mm OD (insulation=13mm thick)
DRAIN PIPE
Supply & Installation of CPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation with 25mm . Necessary U trap for units with clean out plugs to be provided.
40 mm dia
32 mm dia
25 mm dia
Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides.
150mm wide x 75mm Height, 1.6mm thick
300mm wide x 75mm Height, 1.6mm thick
450mm wide x 75mm Height, 1.6mm thick
MECHANICAL VENTILATION SYSTEM
Supply, Installation, Testing & Commissioning & Handing over of the following:
Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Amp plug and wiring between the fan and the socket and low sound level exceeding not more than 50dBA. Fan should be complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc., as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete.
Circular Inline fan 100CFM/15mm WC static pressure
Circular Inline fan 150CFM/15mm WC static pressure
Circular Inline fan 200CFM/15mm WC static pressure
Circular Inline fan 300CFM/15mm WC static pressure
Circular Inline fan 400CFM/15mm WC static pressure
Sheet Metal Work using Factor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards
All duct construction and installation shall be in accordance with SMACNA standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts.
All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes.
To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation
Guide vanes to be installed in elblow, reducers and other accessories
Stiffernner to be considered for ducts with more than 1200mm wide ducts
Duct joining shall completed with adhesive type gasket and sealant
All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure.
With all necessary accessories i.e fixing etc complete.
Rectangular Ducting
Sheet Metal Ducting As per Specification. Pressure 500 Pa
24 G Ducting with Factor Fabricated Duct/ TDF flanges
22 G Ducting with Factor Fabricated Duct/ TDF flanges
Thermal & Acoustic insulation
Thermal Insulation for ducts
Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer.
Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer.
Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works.
Acoustic Insulation for Ducts
Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used.
25mm thick
Air Terminal Devices
Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution (colour for the grill to be confirmed by department before placing the order) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later.
Supply, Fixing, Testing and commissioning of Aluminium powder coated Collar Damper 4-Way Diffusers (450mm X 450mm) with Anti smudge ring and all fixing accesseroies as per standard specifications and practice.
Supply, installation and testing of Jet diffuser with fire resistance flexible double canvas Connection for supply distribution (colour for the Jet to be confirmed by consultant/ PMC team before placing the order)
Supply and fixing of 18G circular butterfly damper 300mm DIA with provision to fix to the rectangular duct with GI circular flanges.
Supply and fixing of Insulated Aluminum 300mm dia flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size
Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper.
Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings.
Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories.
Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper.
Fire damper
Actuator,Sensor,Control panel and relay/communication module, interlinking cabling
Supply, installation and testing of GI Non Return Dampers/ Back draft dampers at suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges.
Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections on both side with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings.
Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification. for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation.
PLANT ROOM PANEL
Electrical AC PANEL-Plant Room:
FOR 7S & 7D BUILDINGS
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosure for main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
Incoming :
800A , 4P, 50kA, Moulded Case Circuit Breaker and micro processor based protection release having adjustable over load, short circuit and earth fault protection - 1 No
Busbars :400A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
400A 50KA TPN MCCB – 4nos
15KW STAR DELTA STATER – 8nos
Metering :
LED Phase indication lamps with individuals Fuses and control with toggle switches- 1set
CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 1set
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosure for main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
3C BUILDINGS
Incoming :
400A , 4P, 50kA, Moulded Case Circuit Breaker and micro processor based protection release having adjustable over load, short circuit and earth fault protection - 1 No
Busbars :400A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
200A 35KA TPN MCCB – 4nos
15KW STAR DELTA STATER – 8nos
Metering :
LED Phase indication lamps with individuals Fuses and control with toggle switches- 1set
CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 1set
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosure for main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
HVAC M.V.PANELS
Supply, Installation, testing and commissioning of 3 phase and neutral 415V 4wire free standing floor mounted MV panel made out of 14 SWG MS sheet and painting with epoxy powder coating the panel shall consist of suitable rating TPN aluminium busbar supported with DMC/SMC barriers and color coded with heat shinkable sleeves the metering shall be provided the pane shall have short circuit withstanding capacity of minimum 36KA and consist of switch gear as mentioned below the panel shall be got fabricated from manufactured with CPRI test certificate only The size of all panel mounting meters shall be 96mm*96mm The panels shall be mounted on 75mm U channels including supply and fixing the same Every MCCB shall be provided with with ON/OFF/TRIP,indicating lamps of LED type. The panel is to be installed in indoor.
HVAC PANEL 1 ( CRR ) OUTDOOR
Incomer 1 : 1 Nos of 250 A, 4P. MCCB, 35KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 3 Nos.
RYB indicating lamps - 3 Nos
250/5A, CL-1, 15VA CT's with resin cast- 3 Nos
Outgoing
63A, TPN, 10KA, MCB, - = 6 Nos
Bus Bars : 250A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
HVAC M.V.PANELS (CDC) OUTDOOR
Incomer 1 : 1 Nos of 200 A, 4P. MCCB, 35KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 3 Nos.
RYB indicating lamps - 3 Nos
250/5A, CL-1, 15VA CT's with resin cast- 3 Nos
Outgoing
63A, TPN, 10KA, MCB, - = 6 Nos
Bus Bars : 200A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
HVAC M.V.PANELS (20D) OUTDOOR
Incomer 1 : 1 Nos of 200 A, 4P. MCCB, 35KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 3 Nos.
RYB indicating lamps - 3 Nos
250/5A, CL-1, 15VA CT's with resin cast- 3 Nos
Outgoing
63A, TPN, 10KA, MCB, - = 6 Nos
Bus Bars : 200A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
HVAC M.V.PANELS (2D) OUTDOOR
Incomer 1 : 1 Nos of 125 A, 4P. MCCB, 25KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 3 Nos.
RYB indicating lamps - 3 Nos
250/5A, CL-1, 15VA CT's with resin cast- 3 Nos
Outgoing
63A, TPN, 10KA, MCB, - = 4 Nos
Bus Bars : 125A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
Electrical cable:
Supply of PVC insulated armoured aluminium conductor cables of 1.1 Kv grade
3 1/2 Core - 120 mm2
Electrical cable:
Supply of PVC insulated armoured Copper conductor cables of 1.1Kv grade
4 core - 10 mm2
4 core - 6 mm2
Termination:
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 1/2 Core - 120 mm2
Termination:
Supplying and making end termination with brass compression glandand Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 core - 16 mm2
4 core - 10 mm2
4 core - 6 mm2
SUBHEAD-XIII : INTERNAL ELECTRIFICATION
Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductor wires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and anodised GI Switch box with modular switch and the box covered with front plate including connections to Earth terminal.
One Light point controlled by one 6 A switch.
Two Light point controlled by one 6 A switch.
Three Light point controlled by one 6 A switch.
Four Light point controlled by one 6 A switch.
Ceiling fan point controlled by one 6 A switch and electronic fan regulator of 100 W step type with concealed MS fan hook box.
Exhaust fan point controlled by one 6 A switch.
Supply and fixing of 6A, 3Pin Socket outlet with 6A switch in Lighting switch boards. (Dependant).
Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A rating with wiring of 2 Runs of 2.5 Sqmm and 1 Run of 2.5 Sqmm FRLS, PVC insulated multistranded Copper conductor wires run in and including 25 mm Dia, 2 mm thick PVC conduit. (Independant).
Supply and Wiring with the following size 1100V grade PVC insulated multistrand FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.
2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including 25 mm Dia PVC Conduit (For Lighting Circuit)
4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wires in and including 32 mm Dia PVC Conduit (For Lighting Sub Mains)
Supply and Commissioning of the following type Fluorescent/ Compact fluorescent light fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall be supplied with lamps. The Catalogue Numbers refers to Philips Make.
36 W Surface mounted LED 4 Feet Length Luminaire
(Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes)
1 x 12 W Surface Mounted LED Luminaire
(Philips Cat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes)
40 W Recess Mounted LED Light Fixture
(Philips Cat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes)
20W Recess mounted Down Light Fixture
(Philips Cat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes)
36W Surface mounted Square Light Fixture
(Philips Cat No SM36S -6500 G6L54W54 PSU OD/Equivalent as per approved makes)
40 W Bulk Head Light Fixture Indoor
(Philips Cat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes)
104W LED High Bay Light Fixture
(Philips Cat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes)
Supply and Installation Testing and Commisioning of 1200 mm sweep single phase Ceiling fan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan )
Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete.
Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete.
Supply and commissioning of 305 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials required.
Supply and commissioning of 380 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials required.
Installtion of Fluorescent/ Compact fluorescent light fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required.
Installation of 1200 mm sweep white colour Ceiling fan with standard down rod (600mm length down rod in false ceiling areas) and all accessories as required etc complete.
Installation of 305 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials as required.
Installation of 380 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (8 + 24), Double door
4 way (8 + 12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
Single Pole
Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuit breaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
160A 4P MCCB, 25 kA
Supplying and fixing of following rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
40A Three Pole MCB 10 kA
SUBHEAD-XIV : POWER WIRING
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way (8 + 36), Double door
8 way (8 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
Single Pole
Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way (4 + 24), Double door
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuit breaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
200A 4P MCCB, 35 kA
Supplying and fixing of following rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
63A Three Pole MCB 16 kA
Supply,erection,testing and commissioning of the following switch sockets with anodised G.I. Box, front plate and fixing screws etc .
6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch.
Supply and fixing of factory made 20A, 1Ph Metalclad socket with plug top & 20A SPMCB in MS box including all fixing accessories
Supply and fixing of factory made 25A, 1Ph Metalclad socket with plug top & 25A SPMCB in MS box including all fixing accessories
Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testing and commissionining etc complete as required.
Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testing and commissionining etc complete as required.
Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.
2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets).
2runs of 6Sq.mm wires with 1run of 6 Sq.mm wire in and including 25mm dia PVC Conduit(For AC Sockets).
4runs of 10Sq.mm wires with 2run of 6 Sq.mm wire in and including 25mm dia PVC Conduit.
4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways
Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existing MS/PVC conduit / Floor race way including all necessary interconnections etc complete.
2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existing PVC Conduit(For 6A Sockets & Switch boards), ferrules incliding all labour charges etc., complte. .
2runs of 4Sq.mm wires with 1run of 4 Sq.mm wires in existing PVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte. .
2runs of 6Sq.mm wires with 1run of 6 Sq.mm wires in existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte. .
4runs of 6Sq.mm wires with 2run of 6 Sq.mm wires in existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte.
4runs of 10Sq.mm wires with 2run of 6 Sq.mm wire in existing PVC Conduit.for run of mains, ferrules incliding all labour charges etc., complte.
4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte.
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc., with Charcoal/ Coke and Salt as required
Supply and laying of following size strips including all necessary inter connections with earth station and equipments
50 X 5 mm Hot dip GI strip
25 X 5 mm Hot dip GI strip
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply and fixing of following size GI Perforated type cable tray made out of 2mm thick G.I sheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thick GI covers.
300 mm wide x 50 mm Height
150 mm wide x 50 mm Height
100 mm wide x 50 mm Height
Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed.
50mm Dia
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II.
3.5C X 400 Sq.mm
3.5C X 300 Sq.mm
3.5C X 240 Sq.mm
3.5C X 185 Sq.mm
3.5C X 150 Sq.mm
3.5C X 70 Sq.mm
3.5C X 25 Sq.mm
4C X 16 Sq.mm
Copper armoured control cables
i) 4C X 2.5 Sq.mm
ii) 7C X 2.5 Sq.mm
iii) 19C X 2.5 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Providing Indoor ordinary end terminations for the foollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire.
3.5C X 400 Sq.mm
3.5C X 300 Sq.mm
3.5C X 240 Sq.mm
3.5C X 185 Sq.mm
3.5C X 150 Sq.mm
3.5C X 70 Sq.mm
3.5C X 25 Sq.mm
4C X 16 Sq.mm
End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs.
i) 4C X 2.5 Sq.mm
ii) 7C X 2.5 Sq.mm
iii) 19C X 2.5 Sq.mm
SUBHEAD-XV : UPS WIRING
Supply and fixing of 2 Nos of 6/16A, 5Pin Socket outlet with 2Nos of switch of 16A rating including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no's of 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuit breaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
200A 4P MCCB, 35 kA
Supplying and fixing of following rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
63A TPN MCB 10 kA
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8 way (8 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 6A to 32A rating 240/415V, 10kA, C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete.
Single Pole
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 10 sq. mm earth wire
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including excavation in all types of soil.
Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm).
25 mm X 5 mm copper strip
50 x 5 mm copper strip below ground.
SUBHEAD-XVI : FLAMEPROOF FIXTURES
Wiring for FLP Fixtures
Supply and Wiring with the following size 1100V grade FRLS Sheathed, XLPE insulated Copper armoured conductor cables conforming to IS 7098 Part I on wall/ Ceiling including all accessories such as Flame proof junction boxes, connectors etc complete.
3 Core 2.5sq.mm armoured (Copper)
3 Core 4sq.mm armoured (Copper)
3 Core 6sq.mm armoured (Copper)
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing FLP end terminations with Copper lugs, double compression type gland with neoprene gasket using Insulation tape, crimping tool etc complete as required.
3Core 2.5sq.mm armoured( Copper)
3Core 4sq.mm armoured( Copper)
3 Core 6sq.mm armoured (Copper)
FLP Fixtures
Supply and Installation of following FLP/LED/Well Glass fixtures made out of Cast Aluminium alloy, toughened clear glass cemented into a bazel ring which is bolted to the body, and lamp holder with Insulator mounted on a bush plate and secured with screws. The body shall be finished with epoxy Grey stove enamelled outside and White inside. The fixture shall be inclusive of all accessories including lamp with control gear.
2X18W FLP LED Type Fixture (Baliga: EXFLO-240/IIC-2x18W 99EXFLO-240 / IIC- 2x18W
120W Flame proof Well Glass LED Light Fixture with fixing accessories.
23/26w, CFL Flameproof Bulkhead Light Fixture with fixing accessories and also including 23/26w CFL Lamp
Supply installation testing and commissioning of following rating FLP Switch Fuse unit with HRC Fuses in FLP suitable size enclosures on angle iron frame work/ FLP Single Phase Sockets complete with all fixing accessories with suitabl FLP cable chambers.
16A Single Phase 250V Grade FLP Socket with switch
10A FLP Switch
32A, 415V 3P+N+E Socket with Plug
63A, 415V 3P+N+E Socket with Plug
32A, 230V 1P+N+E Socket with Plug
63A TPN SFU with HRC Fuses
200A TPN SFU with HRC Fuses
Supply and Wiring with the following size 650V grade FRLS PVC insulated Copper conductor wires in suitable size heavy gauge MS conduit concealed in wall / above false junction boxes, bends, elbows including junction boxes, bends, elbows including and terminated with suitable lugs.
a) 2 runs of 6 Sq.mm PVC FRLS wires with 1 run of 4 Sq.mm PVC FRLS insulated Copper earth wire in 25 mm Dia MS conduit.
Supply Installation Testing and commissioning of Flame proof type TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve.
8Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 24nos 6-25A SPMCBs as outgoings.
6Way TPNMCBDB with 40A, 100mA 4Pole RCBO as incomer and 18nos 6-25A SPMCBs as outgoings.
MV Cables
Supply & commissioning of following size 1.1KV grade XLPE insulated FRLS sheathed armoured aluminium / copper conductor armoured cable. The cable shall conform to IS 7098/ Part I.
4C X 6 sq.mm Copper
4C X 10 sq.mm Copper
3.5C X 25 sq.mm Aluminium
3.5C X 120 sq.mm Aluminium
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 120 sq. mm (clamped with 25x3mm MS flat clamp)
Providing Flame proof end terminations with Copper lugs, double compression type gland with neoprene gasket using Insulation tape, crimping tool etc complete as required.
4C X 6 sq.mm Copper
4C X 10 sq.mm Copper
3.5C X 25 sq.mm Aluminium
3.5C X 120 sq.mm Aluminium
Cable Trays
Supply and fixing of following size GI Perforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc., complete as required including with GI covers.
100 mm wide (for cable of lighting fixtures)
300 mm wide (for cable of lighting fixtures)
Supply and laying of 25 x 5mm G.I Strip at 0.5 mtr below as strip earth including connection /terminating with G.I nut,bolt, spring , washer etc as required ( Jointing shall be done by overlapping and with 2 sets of G.I nut bolt and spring washer spaced at 50 mm ).
Supplying and Laying 6 SWG G.I wire at 0.5 mtr below ground level for conductor earth electrode including connetcion / termination with G.I thimble etc as required.
SUBHEAD-XVII : LIGHTNING PROTECTION
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including excavation in all types of soil.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable and directed by engineer in charge.
32 X 6 mm Aluminium strip conductor with DMC Insulator Supports
50 X 5 mm GI strip conductor including excvation and back filling.
25 X 5 mm Hot dip GI strip
Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories.
Providing and fixing of Test links for Lightning protection system.
SUBHEAD-XVIII: SPECIAL EARTHING
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including excavation in all types of soil.
Supply and laying under ground/above ground of following size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge.
25 x 3 mm copper strip on DMC insulators
25 x 3 mm copper strip below ground.
50 x 5 mm copper strip below ground.
Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing.
Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed.
50mm Dia
SUBHEAD-XIX : TELEPHONE CONDUITS
Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc.,
Supply and laying of 25mm dia, heavy gauge PVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc.,
Supply and laying of 25mm dia, heavy gauge PVC . conduit concealed in wall/ ceiling/ floor and drawing of 12 SWG GI Wire as fish wire for laying of LAN Cables at a later stage and supply of all fixing accessories such as junction boxes, conduit bends, etc., complete as required.
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws.
Supply,Installation,Testing and commissioning of RJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete.
Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT Specifications in already laid PVC Conduit including necessary interconnections.
Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections.
Supply and installation of 100 pair Krone connectors in MS junction box complete as required.
Supply and installation of 50 pair Krone connectors in MS junction box complete as required.
Supply and installation of 20 pair Krone connectors in MS junction box complete as required.
Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed.
50mm Dia
SUBHEAD-XX : FIRE ALARM SYSTEM
Supply, erection, testing and commissioning of Intelligent Addressable Fire Alarm Control Panel (a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in all floor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU board with optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit, fibre optic converter and networking card etc complete in all respects .
2 - Loop Panel ( One Loop for Integration )
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete.
Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS.
COMIBINATION/MULTI SENSOR DETECTORS (Photoelectric + Heat Sensing)
Supply, fixing, testing and commissioning of Addressable anlogue type multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. .
Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete.
Supply, Installation, Testing and Commissioning of UV - IR Flame proof Sensors with a range of 4mtr -15mtr and view angle of 90 deg with Addressable monitor module which shall be addressed by rotary Switch setting.
Make: System Sensor/ Spetrex / Notifier or equivalent
Supply, fixing, testing and commissioning of Addressable anlogue type Beam Detector with transmitter and receiver including short circuit isolator including connections with remote test features etc complete. Range 100 Mtr
MANUAL CALL POINTS:
Supply, erection, testing and commissioning of Addressable analogue type manual call point for indoor installtion.
Supply, Installation, Testing and Commissioning of Flame proof Manual call point with Addressable Monitor Module .
Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proof with 1500 mm Length ISMC 100 standing Post.
FAULT ISOLATION MODULE:
Supply, fixing, testing and commissioning of Fault Isolation module.
Supply, installation, testing & commissioning of addressable fire control module complete as required.
Supply, installation, testing & commissioning of addressable fire Monitor module complete as required.
CABLE:
Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulated copper conductor control cables as per specification.
Armoured Twisted pair 2C x 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete.
Armoured Twisted pair 2C x 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling.
3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs.
Supply and Installtion of 12 Way Elmex terminal powder Coated junction Box including all terminations and Necessary Glands.
Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete.
Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed.
Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation and sand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete.
Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required duly coated with two coats of red colour enamel paint etc., complete.
SUBHEAD-XXI : FIRE FIGHTING
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
150 mm dia
200 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
80mm dia
150mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :
80mm dia
150mm dia
Supplying, Installation, Testing & Commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water monitor gong complete as required
150mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30"x24".
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun metal
Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
4 way - 150 mm dia M.S. Pipe
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm dia. Pipe
80 mm dia. Pipe
50 mm dia. Pipe
Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete.
150 mm dia.
100 mm dia.
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
Supply and installation , Testing and commissioing of approved make 15mm orifice quartzoid bulb pendent type sprinklers, 68°C rating,
Supply and installation, Testing and commissioing of approved make 15mm orifice quartzoid bulb side wall pendant type sprinklers, 68°C rating.
Supply installation and fixing of flow switches in the following Pipe line with 1NO+1NC Contacts
a) 150/100mm dia
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally(Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 of size 150 mm Dia. Including all accessiors like joints bends etc.,
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally(Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 of size 200 mm Dia. Including all accessiors like joints bends etc.,
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm.
Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first class brick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works. Cover should be in two halfs fixed to frame work by means of hinges.
Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump room with MS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete.
250 mm dia. Pipe
200 mm dia. Pipe
150 mm dia. Pipe
100 mm dia. Pipe
80 mm dia. Pipe
Supply, Installation,Testing and Commissioning of air cussion vessel of capacity 250 litres with air release valve and ball valve.
Supply,Installation,Testing and Commissioning of PN 16 Sluice valves with gate of the following sizes.
a) 250mm dia
b) 200mm dia
c) 100mm dia
Supply,Installation,Testing and Commissioning of PN 16 Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete.
a) 200mm dia
b) 80mm dia
Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes.
a) 200mm dia
b)80mm dia
Supply, installation, testing and commissioning of approved make brass "Y" strainer with necessary flanges which should include nuts, bolts, washers, gaskets.
a) 200 mm dia.
c) 100 mm dia.
Supply,Installation,Testing and Commissioning of electrical control panel for diesel engine, main motor and for jockey pump comprising of following.
Incoming : 800A,50KA TPNMCCB - 1SET
800A TPN aluminium busbars - 1set
Outgoings:
(with built in single phase preventor) and ON/OFF/TRIP
indication lamps for motor-2set
Diesel Engine Control
Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header
Supply fabrication and erection of MS angle supports for Pipe lines
Supply and fixing of G.M. ball type valves Conforming to IS
a) 25mm dia
b) 15mm dia
Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head with 70% of Pump efficiency.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head with 70% of Pump efficiency.
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 88 m Head
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally(Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 of size 150 mm Dia including necessay spigot joints bend etc complete
Supply, Installation of following Fire extinguishers & accessories:
CO2 6.5 kg capacity trolley mounted
CO2 22.5 kg capacity trolley mounted
DCP 5 kg capacity (potassium bi-carbonate Uria reaction)
Water buckets with stand
Sand buckets with stand
Showels
Fire Beater
Fire gong/ hand siren
Ceiling Hook
Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Supplying Installation Testing & Commissioning of Ceiling Mounted exit sign/emergency lighting unit uses high-performance led lamps.
SUBHEAD-XXII : EOT CRANES:
Design,manufacture and supply of the following Flameproof Double Girder Crab type EOT Cranes 0 with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of consumables paint etc. as required. The crane shall be designed for earthquake and sesmic qualification. Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Span Suitable.
PART- I : SUPPLY
Supply of Flameproof 30Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 7C &7D Span: 13 mts. ± 0.5 mtrs. Lift: 12 mts. Bay length: 16 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 30ton capacity crane as per above BOQ EOT 1.1)
Supply of material for Gantry Rails section 52 KG of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1)
Supply of Flameproof 10Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 7C &7D (Raw material storage ) Span: 12 mts. ± 0.5 mtrs. Lift: 17 mts. Bay length: 17.5 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 10ton capacity crane as per above BOQ EOT 1.4)
Supply of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 10 ton capacity crane as per above BOQ EOT 1.4)
Supply of Flameproof 20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 13D Span: 12 mts. ± 0.5 mtrs. Lift: 10 mts. Bay length: 45 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 1.7)
Supply of material for Gantry Rails section 60Lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 1.7)
Supply of Flameproof 120/20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 20 mts. ± 0.5 mtrs. Lift: 32 mts. Bay length: 44 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 120/20ton capacity crane as per above BOQ EOT 1.10)
Supply of material for Gantry Rails section CR 100 Rail of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 120/20 ton capacity crane as per above BOQ EOT 1.10)
Supply of Flameproof 20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 10 mts. ± 0.5 mtrs. Lift: 10 mts. Bay length: 20 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 1.13)
Supply of material for Gantry Rails section 60Lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 1.13)
Supply of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 15 mts. ± 0.5 mtrs. Lift: 8 mts. Bay length: 15 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 1.16)
Supply of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 1.16)
Supply of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 12 mts. ± 0.5 mtrs. Lift: 13 mts. Bay length: 15 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 5ton capacity crane as per above BOQ EOT 1.19)
Supply of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 1.19)
Supply of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 9 mts. ± 0.5 mtrs. Lift: 6 mts. Bay length: 12 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 5ton capacity crane as per above BOQ EOT 1.22)
Supply of material for Gantry Rails section 50Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 1.22)
Supply of Flameproof 3Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 8 mts. ± 0.5 mtrs. Lift: 6 mts. Bay length: 10 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 3ton capacity crane as per above BOQ EOT 1.25)
Supply of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 3 ton capacity crane as per above BOQ EOT 1.25)
Supply of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 6 mts. ± 0.5 mtrs. Lift: 5 mts. Bay length: 6 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 3ton capacity crane as per above BOQ EOT 1.28)
Supply of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 3 ton capacity crane as per above BOQ EOT 1.28)
Part-II: - ERECTION, TESTING AND COMMISSIONING
Erection, testing and commissioning of EOT cranes and others mentioned in item S.No.EOT-1.1 to EOT-1.30 of Part-I as per the relevant IS standards and as mentioned in the technical specifications.
Erection, testing and commissioning of Flameproof 30Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 7C &7D Span: 13 mts. ± 0.5 mtrs. Lift: 12 mts. Bay length: 16 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 30ton capacity crane as per above BOQ EOT 2.1)
Erection testing and commissioning of material for Gantry Rails section 52 Kg of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 2.1)
Erection testing and commissioning of Flameproof 10Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 7C &7D (Raw material storage ) Span: 12 mts. ± 0.5 mtrs. Lift: 17 mts. Bay length: 17.5 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 10ton capacity crane as per above BOQ EOT 2.4)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 10 ton capacity crane as per above BOQ EOT 2.4)
Erection testing and commissioning of Flameproof 20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 13D Span: 12 mts. ± 0.5 mtrs. Lift: 10 mts. Bay length: 45 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 2.7)
Erection testing and commissioning of material for Gantry Rails section 60 Lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 2.7)
Erection testing and commissioning of Flameproof 120/20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 20 mts. ± 0.5 mtrs. Lift: 32 mts. Bay length: 44 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 120/20ton capacity crane as per above BOQ EOT 2.10)
Erection testing and commissioning of material for Gantry Rails section CR 100 Rail of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 120/20 ton capacity crane as per above BOQ EOT 2.10)
Erection testing and commissioning of Flameproof 20Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 10 mts. ± 0.5 mtrs. Lift: 10 mts. Bay length: 20 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 2.13)
Erection testing and commissioning of material for Gantry Rails section 60 Lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 2.13)
Erection testing and commissioning of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 10B Span: 15 mts. ± 0.5 mtrs. Lift: 8 mts. Bay length: 15 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 20ton capacity crane as per above BOQ EOT 2.16)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 20 ton capacity crane as per above BOQ EOT 2.16)
Erection testing and commissioning of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 12 mts. ± 0.5 mtrs. Lift: 13 mts. Bay length: 15 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 5ton capacity crane as per above BOQ EOT 2.19)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 2.19)
Erection testing and commissioning of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 9 mts. ± 0.5 mtrs. Lift: 6 mts. Bay length: 12 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 5ton capacity crane as per above BOQ EOT 2.22)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 5 ton capacity crane as per above BOQ EOT 2.22)
Erection testing and commissioning of Flameproof 3Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 8 mts. ± 0.5 mtrs. Lift: 6 mts. Bay length: 10 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 3ton capacity crane as per above BOQ EOT 1.25)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 3 ton capacity crane as per above BOQ EOT 2.25)
Erection testing and commissioning of Flameproof 5Ton capacity Double Girder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Building No.: 3C Span: 6 mts. ± 0.5 mtrs. Lift: 5 mts. Bay length: 6 mts.
Crane operating speeds
Main speed Micro speed
Main hoist : 2.5m/min 0.25m/min
Cross travel : 10m/min 1.0m/min
Long travel : 15m/min 1.5m/min
Micro speed for all motions : 10% of main speed through VVVF drives.
Provision of inching is to be incorporated in the drives.
Erection testing and commissioning of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc complete as per site condition (For 3ton capacity crane as per above BOQ EOT 2.28)
Erection testing and commissioning of material for Gantry Rails section 50 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition (For 3 ton capacity crane as per above BOQ EOT 2.28)
SUBHEAD-XXIII : WATER COOLERS
Supply and fixing of 40 (cooling)/ 80 (storage) ltrs water cooler with water purifier (RO system) and voltage stabilizer etc. complete.
SUB HEAD - XXIV : RAIL WAY TRACK& BRIDGE
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of Soil
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock.
Hard rock (blasting prohibited)
Hard rock (with blasting )
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden of steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50m and lift upto 1.5 m in all kinds of soils
Carriage of earth by Mechanical transport for additional distance for above Embanking Item
(a) From 50 M to 1 KM
(b) From 1 KM to 2 KM
Credit for Hard rock Obtained from above
Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M7.5 grade with minimum cement content of 200 kg /Cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level : Concrete of M25 grade with minimum cement content of 330 kg/cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Plinth and above all levels.
Thermo-Mechanically Treated bars of grade Fe-550D or more.
Centring and shuttering including strutting, propping, etc. and removal of form for the following items of RCC work at all depths and heights complete as per drawings, specifications and as per direction of Engineer-in-charge.
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Including Abudment walls, Wing Walls Toe Walls etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
6mm cement plaster of mix for celling: (a) 1:3 (1 cement : 3 fine sand)
White washing with Cement/Lime to give an even shade (Ceiling & Shaft Area) New work (three or more coats)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Supplying, Laying & Fixing in Position of R260 Grade Track Rail of 60Kg/m (Class 1) in Straight & Curviliner Pattern as per Drawing including anchor bolts and Fixtures Complete as per Directions Of Engineer -In Charge.
SUB HEAD - XXI : ROADS & DRAINS
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
All kinds of Soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
Ordinary rock
Hard rock (blasting prohibited)
Credit for Hard rock Obtained from above
Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M7.5 grade with minimum cement content of 200 kg /Cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Plinth and above all levels.
Thermo-Mechanically Treated bars of grade Fe-550D or more.
Centring and shuttering including strutting, propping, etc. and removal of form for the following items of RCC work at all depths and heights complete as per drawings, specifications and as per direction of Engineer-in-charge.
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality: L D- 2.5 Rectangular shape 600x600 mm internal dimensions - (Ground Floor Trench & Sump Cover)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (External wall & Parapet wall smooth finished)
Providing and laying at or near ground level factory made kerb stoneof M-25 grade cement concrete in position to the required line, leveland curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness ofjoints except at sharp curve shall not to more than 5mm), includingmaking drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge).
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 25 mm compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom On W.B.M / W.M.M. @ 0.75kg/sqm
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) ; specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden of steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50m and lift upto 1.5 m in all kinds of soils
Carriage of earth by Mechanical transport for additional distance for above Embanking Item
(a) From 50 M to 1 KM
(b) From 1 KM to 2 KM
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
SUB HEAD - XXVI INTERNAL AND EXTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
20 mm nominal dia. Pipes
25 mm nominal dia. Pipes
32 mm nominal dia. Pipes
40 mm nominal dia. Pipes
50 mm nominal dia. Pipes
65 mm nominal dia. Pipes
80 mm nominal dia. Pipes
Providing and fixing CPVC BALL VALVE of approved quality (screwed end) : Make Supreme
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
40 mm dia.
50 mm dia.
65 mm dia.
80 mm dia.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS : 5312 complete with rubber gasket, GI bolts, washers, etc. as required.
25 mm dia.
32mm dia.
65 mm dia.
80 mm dia.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 455x610 mm and 45 cm deep for single pipe line, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
All types of soil 300 mm dia
Rocky strata including Boulders 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge.
Supply,Fixing &comossioning of 0.5HP Monoblock pump with 25meters of head. & complete finished item of work per direction of Engineer- in-charge.
SUBHEAD-XXVII : EXTERNAL ELECTRICS
11 KV HT SWITCHGEAR INDOOR
Supply,Installation,Testing and commissioning of the following indoor floor mounted 11 kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steel to be operated on 11KV,Three phase,50HZ A.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCB shall be horizontal draw out single break as per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor
11 KV- H.T SWITCH GEAR PANEL - INDOOR
11 KV VCB panel with one no of 1250 A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings.
11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breaker as Incomer.
CONSTRUCTION - The Switch Gear Panel shall be compartmentalised Designed with cubicles fabricated out of High Quality Sheet Steel . The panels shall be designed having the Following Segregations separately.
a) Busbar compartment
b) Cable and CT compartment
c)) Instrument and Relay Compartment
The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals.
The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement.
SAFETY FEATURES:
a) Mechanical Interlock
b) Door interlock in service position.
INCOMING VCB PANEL
CURRENT TRANSFORMER: (3 No’s) Cast Resin
Ratio 200-100 - 5/5 A , Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection.
METERING: ( 1set)
POTENTIAL TRANSFORMER : (3 No’s) Cast Resin
Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays.
OUTGOING VCB PANEL
The following shall be provided for each Outgoing feeder
CURRENT TRANSFORMER: (3 No’s) Cast Resin
Ratio 75 /5 A , Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection.
METERING: ( 1set)
Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading.
INDICATION LAMPS:
1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lamps for RYB. - (1 set)
CONTROL SWITCHES/PUSH BUTTON
Bus Bar with 1250 Amps Copper - (1 set)
COMMON FOR SWITCHGEAR:
Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCB's for AC/DC Control - (1 set)
MS sheet enclosure suitable for Indoor installation with outgoing cable entry. - (1 set)
Relays Incomer ; Undervoltage relay ,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator
Relays Outgoing Feeder; Numeric IDMT relay ,TCH and Master trip relay, Auxiliary Relays for Transformer Feeder and also with 12 window annunciator
Power Pack - 1 No with necessary Interconnections.
11 KV- H.T SWITCH GEAR PANEL - INDOOR
11 KV VCB panel with one no of 800 A vcb -Indoor as Incomer and 2 Nos 800A VCB as out goings.
11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 800 A Vaccum Circuir breaker as Incomer.
CONSTRUCTION - The Switch Gear Panel shall be compartmentalised Designed with cubicles fabricated out of High Quality Sheet Steel . The panels shall be designed having the Following Segregations separately.
a) Busbar compartment
b) Cable and CT compartment
c)) Instrument and Relay Compartment
The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals.
The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement.
SAFETY FEATURES:
a) Mechanical Interlock
b) Door interlock in service position.
INCOMING VCB PANEL
CURRENT TRANSFORMER: (3 No’s) Cast Resin
Ratio 100-50 - 5/5 A , Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection.
METERING: ( 1set)
POTENTIAL TRANSFORMER : (3 No’s) Cast Resin
Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays.
OUTGOING VCB PANEL
The following shall be provided for each Outgoing feeder
CURRENT TRANSFORMER: (3 No’s) Cast Resin
Ratio 75 /5 A , Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection.
METERING: ( 1set)
Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading.
INDICATION LAMPS:
1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lamps for RYB. - (1 set)
CONTROL SWITCHES/PUSH BUTTON
Bus Bar with 800 Amps Copper - (1 set)
COMMON FOR SWITCHGEAR:
Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCB's for AC/DC Control - (1 set)
MS sheet enclosure suitable for Indoor installation with outgoing cable entry. - (1 set)
Relays Incomer ; Undervoltage relays , Numeric IDMT relay ,TCH and Master trip relay,Auxiliary relays and also with 12 window annunciator
Relays Outgoing Feeders ; Numeric IDMT relay ,TCH and Master trip relay ,Auxiliary Relays and also with 12 window annunciator
Power Pack - 1 No with necessary Interconnections.
Supply and commissioning of 11 KV earthed HT cable of size 3 c x 300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098 - Part 2 - 1983
Supply and commissioning of 11 KV earthed HT cable of size 3 c x 185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098 - Part 2 - 1983
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required.
Above 120 sq. mm and upto 400 sq. mm
Supply, Installation, Testing and commissioning of 11 KV earthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit).
Supply, Installation, Testing and commissioning of 11 KV earthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit).
Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm Earthed XLPE insulated armoured alluminium conductor cable.
Supply, Installation, Testing and commissioning of 1000 KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 OUTDOOR ONAN Transformer with on load tap changer, RTCC panel, AVR and HT Side marshalling box for termination of 11 kv grade , 3 c x 185 sqmm XLPE insulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacity as per IS 1180 ( Level 2 ) with radiators etc
LT SANDWICH TYPE BUS DUCT
Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, 65kA ,Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoor Application IP -65 ( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2.
M.V.PANELS
Supply, Installation, testing and commissioning of 3 phase and neutral 415V 4wire free standing floor mounted MV panel made out of 14 SWG MS sheet and painting with epoxy powder coating the panel shall consist of suitable rating TPN aluminium busbar supported with DMC/SMC barriers and color coded with heat shinkable sleeves the metering shall be provided the pane shall have short circuit withstanding capacity of minimum 36KA and consist of switch gear as mentioned below the panel shall be got fabricated from manufactured with CPRI test certificate only The size of all panel mounting meters shall be 96mm*96mm The panels shall be mounted on 75mm U channels including supply and fixing the same Every MCCB shall be provided with with ON/OFF/TRIP,indicating lamps of LED type. The panel is to be installed in indoor.
MAIN MVPANEL - 1 - Indoor
Incomer 1 : 1 Nos of 1600 A, 4P. EDO ACB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 9 Nos.
RYB indicating lamps - 3 sets
1600/5A, CL-1, 15VA CT's with resin cast- 3 nos.
A Single CT with ratio of 1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers )
Outgoing
800A, 3P, 50KA, EDO ACB - = 6 Nos
630A, 3P, 50KA, EDO ACB - = 6 Nos
400A, 3P, 50KA, MCCB - = 2 Nos
250A, 3P, 35KA, MCCB, - = 2 Nos
200A, 3P, 35KA, MCCB, - = 5 Nos
160A, 3P, 25KA, MCCB, - = 4 Nos
63A, 3P, 16KA, MCCB, - = 6 Nos
Surge Protection Device - 1 No
63 A, 3P, 16KA, MCCB, - = 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required 24 hors clock settings.
Bus Bars : 1600A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
APFC PANEL INDOOR TTA PANEL - 300KVAR
Supply,Installation,Testing and Commissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control.
INCOMER
630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit
2A, control fuse - 3 Nos.
RYB indicating lamps - 1 set
630/5A, CL-1, 15VA CT's with resin cast- 3 nos.
Outgoing
125 A, 3P, SDF , - 2No
63 A, 3P, SDF , - 8 No
Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars
Metering Instruments ; Multi Function Meter in the Incomer and SDF on , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps
Earth Bus; To be provided at the bottom of the Panel of copper
The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation.
BUILDING PANEL - 7C & 7D - Indoor
Incomer 1 Nos of 800 A, 4P. EDO ACB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
2A, control MCB - 9 Nos.
RYB indicating lamps - 3 sets
800/5A, CL-1, 15VA CT's with resin cast- 3 nos.
Outgoing
800A, 3P, 50KA, EDO ACB - = 1 Nos
630A, 3P, 50KA, EDO ACB - = 4 Nos
250A, 3P, 35KA, MCCB, - = 1Nos
200A, 3P, 35KA, MCCB, - = 5 Nos
160A, 3P, 25KA, MCCB, - = 2 Nos
63A, 3P, 16KA, MCCB, - = 12 Nos
Surge Protection Device - 1 No
Bus Bars : 800A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - 13D - Indoor
Incomer 1 :1 Nos of 250 A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
160A, 3P, 25KA, MCCB, - = 4 Nos
63A, 3P, 16KA, MCCB, - = 10 Nos
Surge Protection Device - 1 No
Bus Bars : 250A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - 10B - Indoor
Incomer 1: 1 Nos of 800 A, 4P. EDO ACB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
630A, 3P, 50KA, EDO ACB - = 1 Nos
400A, 3P, 50KA, MCCB - = 1Nos
250A, 3P, 35KA, MCCB, - = 2 Nos
200A, 3P, 35KA, MCCB, - = 1 Nos
160A, 3P, 25KA, MCCB, - = 1 Nos
63A, 3P, 16KA, MCCB, - = 10 Nos
Surge Protection Device - 1 No
Bus Bars : 800A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - 3C - Indoor
Incomer 1: 1 Nos of 400 A, 4P.MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
160A, 3P, 25KA, MCCB, - = 3 Nos
63A, 3P, 16KA, MCCB, - = 15 Nos
Surge Protection Device - 1 No
Bus Bars : 400A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - 20D - Indoor
Incomer 1 3 Nos of 400 A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
250A, 3P, 35KA, MCCB, - = 2 Nos
200A, 3P, 35KA, MCCB, - = 1 Nos
160A, 3P, 25KA, MCCB, - = 1 Nos
63A, 3P, 16KA, MCCB, - = 8 Nos
Surge Protection Device - 1 No
Bus Bars : 400A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - CDC - Indoor
Incomer 1 : Nos of 400 A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
250A, 3P, 35KA, MCCB, - = 2 Nos
200A, 3P, 35KA, MCCB, - = 1 Nos
160A, 3P, 25KA, MCCB, - = 4 Nos
63A, 3P, 16KA, MCCB, - = 10 Nos
Surge Protection Device - 1 No
Bus Bars : 400A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - CCR - Indoor
Incomer 1 3 Nos of 630 A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
630A, 3P, 50KA, EDO ACB - = 1 Nos
250A, 3P, 35KA, MCCB, - = 3 Nos
200A, 3P, 35KA, MCCB, - = 2 Nos
160A, 3P, 25KA, MCCB, - = 2 Nos
63A, 3P, 16KA, MCCB, - = 8 Nos
Surge Protection Device - 1 No
Bus Bars : 630A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
BUILDING PANEL - 2D- Indoor
Incomer 1 : 1Nos of 250 A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
250A, 3P, 35KA, MCCB, - = 2 Nos
200A, 3P, 35KA, MCCB, - = 5 Nos
160A, 3P, 25KA, MCCB, - = 4 Nos
63A, 3P, 16KA, MCCB, - = 6Nos
Surge Protection Device - 1 No
Bus Bars : 250A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
OUTDOOR FEEDER PILAR PANEL
Incomer 1 : 250 Nos of A, 4P. MCCB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS.
Outgoing
160A, 3P, 25KA, MCCB, - = 4 Nos
125A, 3P, 25KA, MCCB, - = 2 Nos
63A, 3P, 16KA, MCCB, - = 6 Nos
Surge Protection Device - 1 No
63 A, 3P, 16KA, MCCB, - = 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required 24 hors clock settings.
Bus Bars : 250A, 3Ph, 4 wire TPN , 50Hz, aluminium bus bars
Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps.
Earth Bus; To be provided at the bottom of the Panel of Gi Strip
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc., with Charcoal/ Coke and Salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including excavation in all types of soil.
Supply and fixing of following earth strips/ conductors. The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel).
50 x 5 MM G.I. Flat
25 x 3 MM GI Flat
50 x 6 MM Copper Flat
6SWG G.I.Wire
Cable Trays
Supply and fixing of following size GI Perforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers.
600mm wide
300mm wide
SAFETY ITEMS
Supply, Installation, Testing and commissioning of the Follwing Safety items as per standrads and specification.
Fire Extinguishers - 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn
Rubber Mats 11 KV , 2 Mtr x 1 Mtr
Rubber Mats 415 V , 2 Mtr x 1 Mtr
Shock treatment Chart with frame and glass
First Aid Box
Sand Bucket with stand with 3 Nos of buckets and also with canaopy.
415 V Danger Boards
11 kv Danger Boards
Single Line Diagram with frame and glass.
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II.
3.5C X 400 Sq.mm
3.5C X 300 Sq.mm
3.5C X 240 Sq.mm
3.5C X 185 Sq.mm
3.5C X 150 Sq.mm
3.5C X 70 Sq.mm
3.5C X 25 Sq.mm
4C X 16 Sq.mm
Copper armoured control cables
i) 4C X 2.5 Sq.mm
ii) 7C X 2.5 Sq.mm
iii) 19C X 2.5 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Providing Indoor ordinary end terminations for the foollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire.
3.5C X 400 Sq.mm
3.5C X 300 Sq.mm
3.5C X 240 Sq.mm
3.5C X 185 Sq.mm
3.5C X 150 Sq.mm
3.5C X 70 Sq.mm
3.5C X 25 Sq.mm
4C X 16 Sq.mm
End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs.
i) 4C X 2.5 Sq.mm
ii) 7C X 2.5 Sq.mm
iii) 19C X 2.5 Sq.mm
SUB HEAD XXVIII :- SEWAGE DISPOSAL
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
450 mm dia. RCC Pipe
600 mm dia. RCC Pipe
900 mm dia. RCC Pipe
1200 mm dia. RCC Pipe
Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design :
100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 455x610 mm and 45 cm deep for single pipe line, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming to IS : 4885.
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With Sewer bricks conforming IS : 4885.
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885.
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With Sewer bricks conforming IS : 4885.
Supply ,Fixing & Commissioning of brown modular septic tank having the capacity of 9500 liters & complete at all levels and heights for the finished item of work and as directed by Engineer-in-Incharge. Make Supremeor equvalent
Supply ,Fixing & Commissioning of brown modular septic tank having the capacity of 5500 liters & complete at all levels and heights for the finished item of work and as directed by Engineer-in-Incharge. Make Supreme or its equivalnet.
Supply, fixing, testing and commissioning of NU-Drain UPVC Pipes soil and waste pipes jointed with rubber ring with good quality lubricant for shafts and for External drainage lines with slovent cement. As per IS - 15328-2003 for pipes.This pipes are very easy to join using slip on techinces with welded or individual couplers provided with pipes. inclusive of all necessary specials like bends, tees, offsets, junctions etc., laid under ground with suitable clamps and specials curing etc., complete.(SN :4 & 8 Pipes).For external sewage.
a)110mm Dia
b) 160mm Dia
SUBHEAD-XXIX : AREA LIGHTING
Supply and erection of steel stepped and swaged tubular poles of 9 mtr long (410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Long for incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable.
The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.)
Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4 PCC Pedestal etc complete. The pole shall be with Junction box consisting of MCB. The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed with weather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixture including supply of driver and fixing clamps etc complete.
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II.
4Core 10sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
Upto 35 Sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 Sqmm
Providing End terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductor cable with compression type steel gland, alluminum lugs using crimping tool, Insulation tape, Identification tags etc.,complete
4Core 10 sq.mm
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (8 + 12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete.
Single Pole
Supply and Commissioning of the following type Fluorescent/ Compact fluorescent light fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall be supplied with lamps. The Catalogue Numbers refers to Philips Make.
40 W Bulk Head Light Fixture Outdoor
(Philips Cat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes))
150W LED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete
SUBHEAD-XXX : VERTICAL INNER FACE TRAVERSE
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of Soil
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock.
Hard rock (blasting prohibited)
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Supplying and filling of earth obtained within MoD land by mechanical transport including lead and lift and filling in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden on steel rammers, rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads.
Credit for Hard rock Obtained from above
Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M7.5 grade with minimum cement content of 200 kg /Cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level : Concrete of M25 grade with minimum cement content of 330 kg/cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Plinth and above all levels.
Thermo-Mechanically Treated bars of grade Fe-550D or more.
Centring and shuttering including strutting, propping, etc. and removal of form for the following items of RCC work at all depths and heights complete as per drawings, specifications and as per direction of Engineer-in-charge.
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing
6mm cement plaster of mix for celling: (a) 1:3 (1 cement : 3 fine sand)
White washing with Cement/Lime to give an even shade (Ceiling & Shaft Area) New work (three or more coats)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
SUB HEAD - XXXI : CHAIN LINK FENCING
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of Soil
Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level :
Concrete of M7.5 grade with minimum cement content of 200 kg /Cum
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing
Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
SUBHEAD-XXXII : INSTRUMENTATION CABLE ROUTING
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing & Laying and Fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75cm deep) and re-filling etc., as required
150mm dia
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc., with Charcoal/ Coke and Salt as required
SUBHEAD-XXXIII : ARBORICULTURE :
TREE PLANTATION
Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit
(I) AVENUE / FLOWERING TREES / Palms
a) 1mts x 1mts x 1mts (L X W x D )
b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts
c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5'-6' height, with a clear minimum height of 4'-5' from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical
i) Phonix Palm
ii) Red Palm
iii) Golden Palm
iv) Fox Tail Palm
v) Areca Palm
d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately
LAWN PLANTATION
a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed).
b) Now rough dressing of trenched ground including breaking clods & flooding with water.
c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts.
d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical.
e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds
i) With Bermunda grass (15cm x 15cm apart)
ii) Carpet of grass turfing
iii) Supply & turfing of artificial lawn
iv) After ward maintenance of lawn area, green & weed free for 03month with standard specification after completation date of contract
SHRUB PLANTATION (SOLO)
Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit
i) Pit size 0.60mts x 0.60mts (Dia x Depth)
ii) Pit size 0.45 dia x 0.60mts Depth
b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately.
c) Afterward 01 year maintenance as per standard specification
SHRUBBERY PLANTATION - (SHRUBS IN GROUPS)
Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure
a) L X W X 0.60 mts depth
b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation
c) Termite treatment - Thimet 10G granules @100 gms / Sqmts
d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance
e) Afterward 01 year maintenance as per standard specification
HEDGE PLANTATION
a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation.
b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows
i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation)
ii) Density - @07 Nos plants / running meters (staggered condition)
c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately
d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification
GROUND COVER
Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal
b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well.
c) Regular maintenance afterward for 01 year as per standard specification
FLOWER BED PREPARATION
Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts
a) SEASONAL FLOWERING BED SIZE FORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired
b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year)
i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter
c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately
MOUND
Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure
BRICK EDGING
Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts
Brick Paving : Supply and Paving of wire cut bricks on sand bed
Terracotta Pot : Terracotta Pots of height 4' & width 1m made with 8mm rod chicken mesh with cement mortar complete
PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete
Supply & erection of 2 Hp pump with all accessories including panelboard etc
Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable
GOOD EARTH / AGRICULTURE SOIL
a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earth to be paid separately, after reduction of 20% of stacked volume of good earth
b) Cattle manure : Supply of cattle manure
Please Enable Macros to View BoQ information
eProcurement System Government of India Created By: Ravula Mahender Created Date/Time: 21-Nov-2025 03:38 PM Tender Title: Provision of Civil Works AND Allied Services for Certain Technical Buildings Phase I at SFC Jagdalpur Tender ID: 2025_DRDO_881248_1
Tender Enquiry No. : CCE(R&D)S/ENQ/CIV/JAG/SFC/22/2025-2026 DATED 13 OCT 2025
Mosh Varaya Infrastructure Limited (GSTN-22AACCC5192J1ZQ) BID ID -3311435
SHRI GURMUKHDAS CONTRACTORS PVT. LTD. (GSTN-08AAHCS4756R1ZF) BID ID -3311557
M/s SLC PROJECTS Pvt Ltd (GSTN-37AAJCS8616C1Z8) BID ID -3312148
CMK Projects Private Limited (GSTN-33AAGCC2202B2ZM) BID ID -3312177
Inderjit Mehta Constructions Private Limited (GSTN-07AAACI3235L1ZM) BID ID -3312350
Vishal Infrastructure Ltd (GSTN-29AABCM3918R1ZT) BID ID -3312872
QUICK BUILDERS (GSTN-27AAAFQ0227F1ZP) BID ID -3313381
RMS CONSTRUCTION PVT. LTD. (GSTN-07AACCR6967N1ZM) BID ID -3313520
NSC Projects Pvt. Ltd. (GSTN-07AADCN4958N1ZU) BID ID -3316557
Varindera Constructions Limited (GSTN-07AABCV3315P4Z0) BID ID -3317163
RMS CONSTRUCTION PVT. LTD. (BID ID -3313520)
NSC Projects Pvt. Ltd. (BID ID -3316557)
SHRI GURMUKHDAS CONTRACTORS PVT. LTD. (BID ID -3311557)
QUICK BUILDERS (BID ID -3313381)
M/s SLC PROJECTS Pvt Ltd (BID ID -3312148)
Vishal Infrastructure Ltd (BID ID -3312872)
CMK Projects Private Limited (BID ID -3312177)
Varindera Constructions Limited (BID ID -3317163)
Inderjit Mehta Constructions Private Limited (BID ID -3312350)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.68 MB
Tendernotice_2.pdf
PDF • 0.77 MB
Tendernotice_3.pdf
PDF • 0.26 MB
Tendernotice_4.pdf
PDF • 0.71 MB
Tendernotice_5.pdf
PDF • 0.06 MB
BOQ_926254.xls
BOQ • 1.19 MB
D1.rar
Additional Documents • 4.89 MB
D3.rar
Additional Documents • 1.01 MB
D2.rar
Additional Documents • 5.51 MB
siteplan.pdf
Additional Documents • 24.24 MB
JLOI.PDF
aoc-document • 0.05 MB
boqcomparativechart.xlsx
comparative-boq • 0.01 MB
Download all tender documents and submit your bid