Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.9 LAdmitted-Finance A 8 MOHAN COOPERATIVE INDUSTRIAL ESTATE MATHURA ROAD NEW DELHI 110044 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110044 | ₹61.9 L | L1 | Admitted-Finance |
| 2 | L2₹73.6 LAdmitted-Finance | ₹73.6 L | L2 | Admitted-Finance |
| 3 | L3₹82.4 LAdmitted-Finance | ₹82.4 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AIMIL LIMITED L1 | Indian Technologies L3 | manish scientific instruments company L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and Installation of RAINFALL SIMULATOR | 1 | nos | 52,44,900 ₹61.9 L | 69,84,000 ₹82.4 L | 62,36,000 ₹73.6 L |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
27 Feb 2026, 5:00 pmClosed
Dr.K.Muthukkumaran
Dr.K.Muthukkumaran, Professor, DEPARTMENT OF CIVIL ENGINEERING
Supply and installation of RAINFALL SIMULATOR
2026_NITT_897353_1
1720/2025/NITT
Open Tender
Miscellaneous Goods
84 days
NIT
Please refer Tender documents.
18 documents required · 18 mandatory
₹0
₹1.2 L
Yes
13 Mar 2026
6 Feb 2026
2 Mar 2026
6 Feb 2026
27 Feb 2026
6 Feb 2026
Supply and Installation of RAINFALL SIMULATOR
Please Enable Macros to View BoQ information
Description
Bidder's Name
Bidder's Address
Bidder's Email ID
Bidder's GSTIN
Bidder's PAN
If the Bidder is Exempting EMD then provide following details
NSIC/MSME Government RegistrationNumber
NSIC/MSME Certificate Validity
Bidder's Reference Number and Date
Description
Name of the Equipment / Good:
SPECIFICATIONS:
Installation Required
Warranty (in months)
AMC Required
Delivery Period (Weeks)
Shipment Terms
Payment Term
Performance Security
Bid/Quote validity
Technical Specifications
Name of the Equipment / Goods
Make: Model:
A Self-contained facility for the study of flow through permeable media.
Tank Specifications
Length : 2m(Approx)
Width : 1m(Approx)
Height: 0.5m(Approx)
Flow meter range : 0.4 – 4.4 litres/min
Runoff collector : 17 x 0.5 L Compartments
Overall Dimensions
Length : 2.80m(Minimum)
Width : 1.25m(Minimum)
Height : 1.8m(Minimum)
Electrical supply : 220V – 240V / 1ph/50Hz
1m³ washed, well-graded gravel, range 2.0-5.0mm
Polythene sheet for impermeable catchment
Four plastic containers for reservoir storage
Permeable pipe for tile drain
Operating & Maintenance Manual
Experiment Capabilities
▪ Storm hydrographs from single or multiple storms
▪ Storm hydrograph from a previously saturated catchment
▪ Storm runoff from an impermeable catchment
▪ Effect of a moving storm on flood hydrograph
▪ Effect of reservoir storage on flood hydrograph
▪ Effect of land drains on flood hydrograph
Accessories
True Density Measurement Apparatus(Gas Pycnometer) for soil
Cell Volume : 10 cm3
Temperature : 4 °C to 60°C with a stability of ±0.025°C
Volume accuracy : 0.02%
Volume repeatability : 0.01%
The system shall provide stable, controlled Temperature with a stability of ±0.025°C or better.
The system shall store past measurement results on internal memory without dependence on an external PC or drive. Available storage capacity shall support the storage of more than 1000 measurement results to prevent the loss of prior work.
Network communications via both Ethernet and WiFi must be incorporated
The system shall support active communication between other similar instruments that are connected to one another. Communication includes sharing of results and methods.
The system shall support remote data access, status monitoring, and control from workstations located without consideration of physical distance.
Sample pressurization shall be available in both sample-to-reference-chamber, or reference-to-sample-chamber directions.
The instrument shall display measurement results in a graphical format: a plot of density or volume as a function of measurement cycle.
The system shall include a lid that attached to the instrument body with a hinged arm.
The system shall employ real gas equation of state calculations to determine volume from absolute pressure and temperature measurements.
Advanced Dew Point Meter to measure climate parameters
Should be able to measure and record the following parameters,
• Relative humidity with a range of 0 to 100%RH
• Air temperature with a range of -20 to +80°C
• Surface temperature with a range of 20 to +80°C
• Dewpoint temperature
• TΔ (the difference between surface temperature and dewpoint)
• Dry Bulb temperature
• Wet Bulb temperature
• External temperature correction (K-type)
• Specific humidity
Should be supplied with data management software
Should be Water-resistant and dustproof with fully sealed sensors - rating equivalent to IP66
The instrument should be operated by either batter or via USB cable
Advanced Geotechnical Data Logger with PC & Printer
Analog input : Isolated programmable, 48 single-ended, 32 differentials, 16 (3-wire/ 4-wire)
Analog sensors : Voltage, Current , Thermocouples, RTD’s, Thermistors, Monolithic Temp. Sensors, Strain Gauges, Bridge Sensors
Effective resolution : 18-bit
Analog output : Isolated programmable 16-bit DAC, 0-10 V or 0-20 mA
Operating temperature : -40…+70°C
Storage : 128 MB
Internet protocol : HTTP, FTP, SMTP
Internal battery : 6 V @ 4 Ah
Coil resistance : 50...200 Ω
Stimulation : Single pulse pack (36 V @ 200 us)
Suitable PC & Printer to be supplied
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_943220.xls
BOQ • 0.33 MB
tender.pdf
Tender Documents • 1.56 MB
tech.xls
Additional Documents • 0.07 MB
Download all tender documents and submit your bid