Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC KOOTHIPARAMBIL HOUSE KOZHAMMUCHI POST VETTUKAD THRISSUR KERALA 680504 | THRISSUR | THRISSUR | KERALA | 680504 | ₹9.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.8 LRejected-AOC | ₹9.8 L | L2 | Rejected-AOC L2 |
| 3 | L3₹11.0 LRejected-AOC CHAKKALAKKAL H KOTTAT P O | ₹11.0 L | L3 | Rejected-AOC L3 |
| 4 | L4₹12.3 LRejected-AOC | ₹12.3 L | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | Tesla Consulting Engineers L1 | PONNU HYLINE L4 | Johnson AV L2 | BIJU JOSE L3 |
|---|---|---|---|---|---|---|---|
| 1.00Electrification | |||||||
| 1.00 | OD124715/2025-2026:Supply, Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystallin silicon solar cells, providing check metering( energy meter) , necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 18%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections, Interconnections, supply and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. (Rate per KWp)( Make TATA solar Power/waaree energiesLtd/Vikram Solar/Havells/Renew sys solar) | 15 | kW | 50,000 ₹7,50,000 | 71,300 ₹10,69,500 | 56,666 ₹8,49,990 | 63,000 ₹9,45,000 |
| 1.00 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 2 | set | 10,000 ₹20,000 | 8,600 ₹17,200 | 8,600 ₹17,200 | 8,000 ₹16,000 |
| 1.00 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | 30 | metre | 200 ₹6,000 | 45 ₹1,350 | 48 ₹1,440 | 47 ₹1,410 |
| 1.00 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 30 | metre | 250 ₹7,500 | 65 ₹1,950 | 66 ₹1,980 | 67 ₹2,010 |
| 1.00 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) | 4 | each | 50 ₹200 | 25 ₹100 | 28 ₹112 | 24 ₹96 |
| 1.01 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) | 6 | each | 50 ₹300 | 30 ₹180 | 29 ₹174 | 26 ₹156 |
| 1.01 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | 20 | metre | 300 ₹6,000 | 350 ₹7,000 | 200 ₹4,000 | 350 ₹7,000 |
| 1.01 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm | 25 | metre | 350 ₹8,750 | 400 ₹10,000 | 275 ₹6,875 | 400 ₹10,000 |
| 1.01 | 90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run | 28 | metre | 700 ₹19,600 | 680 ₹19,040 | 550 ₹15,400 | 630 ₹17,640 |
Tender Value
₹12.7 L
EMD Value
₹31,765
Closing Date
26 Dec 2025, 6:00 pmClosed
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
DEPOSIT-IMPLEMENTATION OF SOLAR POWER PROJECT IN THE COURT COMPLEX IRINJALAKKUDA, Thrissur District.-SOLAR-General Electrical Work-1
2025_PWD_822763_1
ESDT(ET)98/AEE/25-26
Open Tender
Electrical Works
120 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹31,765
21 Mar 2026
19 Dec 2025
29 Dec 2025
19 Dec 2025
26 Dec 2025
19 Dec 2025
Work Name:DEPOSIT-IMPLEMENTATION OF SOLAR POWER PROJECT IN THE COURT COMPLEX IRINJALAKKUDA, Thrissur District.-SOLAR-General Electrical Work-1
ation of electrical/fire and drawing per A3 sheet additional copy E90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp OD124716/2025-2026:Supply & fixing 3 Phase, 4 wire, net metering 110 V (L-L), -/1 A CT or -/5A CT, accuracy class 0.2, TOD meterÄOD124719/2025-2026:Supply and installation of switch gear units with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work using necessary bolts & nuts, making good the damages, color washing etc. including giving necessary connections as required. (excluding cost of HRC fuse links in case of SDF/ SDFCO) ( front handle) 63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN / BS fuse OD124718/2025-2026:Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic Syntex meter box of folowing size suitable for fixing 3 pase KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 650x350x250 (GS-MB 6535)no
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1379017.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Tendernotice_2.pdf
PDF • 0.02 MB
Tendernotice_3.pdf
PDF • 0.15 MB
Tendernotice_4.pdf
PDF • 0.05 MB
Tendernotice_5.pdf
PDF • 0.05 MB
Tendernotice_6.pdf
PDF • 0.27 MB
viewsbd.pdf
Tender Documents • 1.63 MB
viewnit.pdf
Tender Documents • 0.02 MB
BOQ_1379017.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid