Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.2 LAccepted-AOC 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 1 | Accepted-AOC Being Lowest | |
| 2 | 2₹47.7 L+₹22,469.48 (0.47%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | 2 | Rejected-AOC Not L-1 | |
| 3 | 3₹47.9 L+₹41,049.61 (0.87%)Rejected-AOC DOOR NO 50 01 56 9 FLAT NO 9 SURYA TOWERS ASR NAGAR SEETHAMMADHARA NE VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 3 | Rejected-AOC Not L-1 | |
| 4 | 4₹49.1 L+₹1.6 L (3.46%)Rejected-AOC D NO 50 117 17 9 7 ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 4 | Rejected-AOC Not L-1 | |
| 5 | 5₹50.0 L+₹2.5 L (5.31%)Rejected-AOC | 5 | Rejected-AOC Not L-1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Jan 2020, 6:00 pmClosed
Shri Rajesh Kumar IDSE Offg GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF STORE ROOM ADJOINING DSC OFFICE BUILDING NO P 380 AS AND AS AND REPAIRS TO TELEPHONE EXCHANGE BUILDING AS AND AS TO RUDRA GATE BUILDING AND PROVISION OF HARDSTANDING IN GUN GROUND INFRONT OF GUN GROUND REPAIR SHOP AT NAD UNDER AGE BR II
2019_MES_300733_1
8867
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE ND Visakhapatnam
₹98,000
Yes
19 Feb 2020
25 Nov 2019
16 Jan 2020
25 Nov 2019
10 Jan 2020
10 Dec 2019
Amount
Excavation over areas not exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed.
Removing excavated material /soil to a distance ewxc 250m but not exceeding 500m and depositing where directed complete all as specified and directed.
M & L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified and directed.
M & L for PCC 1:3:6, type C-1, using 20mm graded stone aggregate as in cast in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M & L for 100mm thick, PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in road / path / hard standing laid to slope in panels finishing even and smooth without using extra cement complete all as specified and directed.
M & L for Machine pressed precast cement conctete coloured interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade over and including 50mm thick sand complete all as specified and directed.
S & F 18 to 20mm thick Granite (of any type) tiles as in vertical surfaces machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over and including 10mm thick backing coat in CM 1:4 icomplete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description fixed in any position complete all as directed
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of plinth beams and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, columns and similar work for fair finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
M & L for TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT bars 5mm dia and over upto 10mm dia as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia as in stirrups, spacers, binders complete all as specified and as directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in foundations, rafts, footings, plinth beams, basement slabs etc complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
S & F mild steel work as in Bands, straps, hold fasts, stiffners for fencing posts, struts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conorming to Fe 410-W complete all as directed
S & F Mild steel screw bolts (machine made) of 16 to 20mm diameter of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as directed
S & F mild steel work as in wind ties and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for stainless steel letters 20cm height fixed on granite / suitable back ground/wall complete all as directed
M & L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated / 'Z' profile steel sheet of 0.50mm thick, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directetd.
Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as directed.
M & L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as directed.
M & L for 150mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring / hard standing laid to slope in panels finishing even and smooth without using extra cement complete all as specified and directed.
M & L for forming 12mm thick Expansion joints for 150mm thick concrete slab filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as directed by the Engineer-in-charge
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified
M & L for 2nd class hardwood 35mm thick Factory made, plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically presure treated fitted to chowkats complete all as specified and directed.
M & L for 2nd class hard wood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars any numbers for securing glass, etc. complete all as specified.
S & F 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
S & F solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as specified complete all as directed.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as specified and as directed.
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 100mm complete all as specified and directed.
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 75mm complete all as specified and directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 100mm complete all as directed.
S & F aluminium anodised barrel tower bolt of size 150mm long of extruded section complete all as specified
S & F aluminium anodised barrel tower bolt of size 100mm long of extruded section complete all as specified
S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed.
S & F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as directed
M & L for Aluminium powder coated (Thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing complete all as directed.
M & L for Anodised aluminium powder coated (Thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
S & F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F Solar control film 50 micron reflective type sticked to glass panes as per manufacturers instructions complete all as specified and directed.
S & F 18mm thick Block board, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work complete all as directed
M & L for Aluminium powder coated (Thickness of powder coating 50 micron) Deco grills of Model DG-104 (10mm) chequered mesh 75mmx75mm riveted with rivets and fixed with and including suitable aluminium 'U' channel with necessary fixing arrangements including dismantling old grill complete all as directed.
S & F in repairs Aluminium (extruded section) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S & F Aluminium plate type II Gate and shutter, hook & eye 125mm size
Demolition of unreinforced cement concrete in ground floors and pavings not exc 15cm thick complete all as directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection laid to slope in panels including joints filled with mastic filling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Dismantling Structural steel work including doors, gates but excluding framed truss complete all as directed
M & L for Steel rolling shutters 1.25mm thick laths, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete but gear operated type with bevel gear box and crank handle complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying 3mm thick wall care putty for making good undulations to obtain smooth surface and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of painted surfaces and applying one coat of distemper oil emulsion complete all as spcified and directed.
M & L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of painted surfaces and applying one coat of cement base paint complete all as spcified and directed.
M & L for providing and injecting emulsion for post construction anti-termite treatment under existing floors using emulsion CHLOROPHYRIFOS 20 EC at 1% concentration at the rate of one litre per each hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floor complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing roof treatment including concrete sub base, roughening the surfaces including M & L for brushing cleaned roof surfaces with neat cement slurry @3kg/ Sqm and applying 5mm thick cement screed in cement mortar 1:4 mixed with and including water proofing compound @ 2% by weight of cement, applying polymeric water proofing membrane of weight not less than 3 Kg/Sqm including coating the surface with water based bituminous primer @ 0.5 lit / Sqm and hot blown bitumen @ 1.20 Kg/Sqm at the bottom and another coat at top of the membrane and finally finished with one coat of bitumineous aluminium paint at 0.1 Kg/Sqm complete all as specified and directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish of the premises complete all as directed
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
S & F coloured Glazed ceramic tiles of size 300x200x7mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:3 complete all as specified and directed.
S & F Machine cut kota stone slab flooring 20 to 25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
S & F Machine cut kota stone slab 20 to 25mm thick as in vertical surfaces such as skirting laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
Taking down GI tubing 15mm bore with all fittings and fixtures complete all as specified and directed.
Taking down GI tubing 20mm bore with all fittings and fixtures complete all as specified and directed.
Supplying and fixing of 16mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls / ceiling or laying in floors complete all as specified and directed.
Supplying and fixing of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls / ceiling or laying in floors complete all as specified and directed.
S & F in repairs Wash down water closet (Pedestal pattern), Vitreous China white, plastic water closet seat of same colour closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F PVC valveless, syphonic action type, flushing cistern, 10 lit capacity, low level, white, with inlet, ball valve, float and handle including brackets and 32mm bore PVC flush pipe complete all as specified and directed.
S & F in repairs Vitreous china wash basin, white flat back size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling, 32mm dia PVC waste pipe complete all as specified and directed.
S & F PVC connection 15mm size with PTMT nuts of length 450mm complete all as directed.
S & F in repairs Vitreous China urinal, half stall type white, with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. (excluding flushing cistern, flush pipe and waste pipe)
S & F in repairs stainless steel tubular towel rail 20mm dia, D type, 60cm long between facings including brackets complete all as directed.
S & F in repairs 15mm dia Pillar tap, fancy type chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs Grating round 150 mm size PTMT (min weight 100 gms) complete all as directed.
S & F in repairs 15 mm bore fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
S & F in repairs 15mm dia fancy type, CP Stop valve, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F false ceiling grid comprising of powder coated Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with clips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre suitable for and including 12mm thick gypsum board finished with 10mm thick plaster of paris (gypsum anhydrous) ceiling complete all as specified and directed by the Engineer-in-Charge.
Surface dressing not exc 15cm deep and getting out in soft / loose soil
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3.0m in depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to to soffits of uspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 duly mixed with and including water proofing compound @ 2% in second layer, finished even and smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces finished even and smooth with out using extra cement complete all as directed.
M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in DPC including necessary form work complete all as specified and directed.
M & L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at 2.25 litres per linear running metre including drilling and plugging holes with cement mortar (1:2) to match with the existing surface complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick, PCC 1:4:8, type D-2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for 50mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for providing and injecting chemical emulsion for post construction anti-termite treatment at points of contact of wood work by chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at the rate of 0.5 litre per each hole by drilling 6mm dia holes at a downward angle of 45 Degree at 150mm centre to centre complete all as specified and directed by Engineer-in-Charge.
M & L for 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars any numbers for securing glass, etc. complete all as specified.
M & L for mild steel framed work such as grills, gratings, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directetd.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directetd.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of 20mm dia including modular terminal boxes and white cover plate with frame including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan / bell point / 5 Amps controlled by one switch complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 2.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of 20mm dia including modular terminal boxes and white cover plate with frame including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One power point on independent board complete all as specified and directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 2.5 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
S & F MCB DB, TPN, 4 way, double door, 415 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F MCB, TPN, 63 Amps, 10 KA
S & F MCB, SP, 5 to 32 Amps, 240 Volts
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular switch single pole, 1 way, 16 Amps, 1 module
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Highbay / Flood light 9000 Lumens (min) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F new generation Post top energy saving 40W, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape with high power LED as light source with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light 4500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.5m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix loop-in / loop-out box of internal size 250x210x115mm made of FRP (Hot moulded type) with weather proof canopy and locking screws along with 5/6 AMps MCB-01 No, 50 AMps rated 3 pole connector - 01 No, neutral link mounted and DIN rail suitable size for mounting MCB / connector, etc complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as directed by the Engineer-in-Charge.
Cutting the exiusting bituminous carpet road for laying of UG cables / GI pipe and making good the disturbed portion complete all as directed
Supply and laying GI pipe 40mm dia light grade for cable protection complete all as directed
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 6 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc complete all as directed
Taking down carefully existing ceiling fan of any type and sweep from any position and refixing the same in new / old location after necessary cleaning for dust, grease and replacement of defective spares, servicing, overhauling and rewinding complete all as specified and directed by the Engineer-in-Charge.
M & L for Cutting chases in brick wall, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 6.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, 300 W, complete all as specified and directed.
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F MCB DB, Vertical TPN, 8 way, double door, 415 Volts with 200 Amps rated bus bar suitable for incoming 125 Amps with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F MCCB TPN, 125 Amps, 36 KA
S & F Square recessed mounted LED light (2'x2') of 3600 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Taking down tube light fitting 9/18 watts from existing position and refixing the same in original position duly replacing the copper conductor wire of suitable size and length complete all as directed
Taking down existing Security light fittings 25W capacity from existing position and refixing the same in original position duly replacing the copper conductor cable of suitable size and bracket made of 25mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 35 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
S & F Earth continuity conductor or main earthing lead of 20x3mm copper earth strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified.
S & F Aluminium strip 25x3.15mm as roof conductors and down conductors buried in ground / fixed on wall with means of hylam sheet with epoxy based insulator and screws, bolts, nuts and lead washers complete all as specified and directed. (Note: Hylam sheet block shall be provided in two pieces each 10mm thick one fixed to base with brass screws and the other fixed over it]
S & F Earth continuity conductor or main earthing lead of 32x6mm GI strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
S & F Test point terminal block made of gun metal or Phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws and secured to wall complete all as specified and directed.
Supply, install, testing and commissioning of five star rated hi-wall split units indoor/outdoor with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil, EER 3.2 of capacity 1.5 TR including necessary bracket and drain system with 20mm dia PVC pipe upto ground level complete all as specified and directed by the Enginer-in-Charge.
S & F voltage stabiliser for automatic operation, single phase naturally air cooled, copper wounded as per IS 8448-1989 with digital display, wall mounted, indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilsed at 230 Volts with accuracy of + 2.5% and of capacity 5 KVA complete all as spcified and directed.
S & F MCB DB, SPN, 8 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F MCB, SPN, 40 Amps, 240 Volts
S & F Building Security light 2500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.5m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F ceiling fan, Five star rated, single phase, 230Volts of size 1200mm sweep including regulator and provision of twin core flexible copper cable of suitable size from ceiling rose to fan including taking down old fan and depositing to MES store yard complete all as specified and directed by the Engineer-in-Charge.
S & F exhaust fan, AC, single phase, 230Volts of size 380mm sweep with louvers, heavy duty, suitable for 50Hz, free air flow complete including provision of 3 core flexible copper cable of suitable size from ceiling rose to fan including taking down old fan and depositing to MES store yard complete all as specified and directed by the Engineer-in-Charge.
ALLURI CONSTRUCTIONS
SREE VIJAYALAKSHMI ENTERPRISES
ASR CONSTRUCTIONS
SRI THULASI TECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .