Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC 466 TAGORE STREET COLLEGE ROAD BARNALA 148101 PUNJAB | BARNALA | BARNALA | PUNJAB | 148101 | ₹24.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹25.7 LRejected-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹25.7 L | L2 | Rejected-AOC Other Than Lowest Bidder |
| 3 | L3₹26.3 LRejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹26.3 L | L3 | Rejected-AOC Other Than Lowest Bidder |
| 4 | L4₹27.5 LRejected-AOC H NO 33 VPO KHERI SALABAT PUR DISTT RUPNAGAR PUNJAB 140111 | RUPNAGAR | RUPNAGAR | PUNJAB | 140111 | ₹27.5 L | L4 | Rejected-AOC Other Than Lowest Bidder |
| Sl No | Description | Qty | Unit | Jai Maa Electrical Works L2 | GS Engineers L3 | LA ENTERPRISES L4 | OM HARI HAR ENGINEERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including ,fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed. | 680 | PER POINT | 2 ₹1,360 | 30 ₹20,400 | 5 ₹3,400 | 1 ₹680 |
| 2.00 | Taking down existing unserviceable MCB DB/TPN along with MCBs complete by disconnecting all as directed. | 48 | EACH | 5 ₹240 | 50 ₹2,400 | 10 ₹480 | 1 ₹48 |
| 3.00 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit etc. removing materials deposited in store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified. Note :-- Rates for cutting/chases in walls and making good disturbed area deemed to be included in the quoted rate | 1,210 | RM | 3 ₹3,630 | 30 ₹36,300 | 4 ₹4,840 | 1 ₹1,210 |
| 4.00 | Taking down old unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed. | 953 | EACH | 5 ₹4,765 | 30 ₹28,590 | 4 ₹3,812 | 1 ₹953 |
| 5.00 | Receiving complaints Daily basis from JE incharge/site incharge lodged by the user/occupants of Internal electric/summer appliance, street light / concern external electric supply nature, rectification of the fault as per the detailed by JE incharge/ AGE E/M to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of Engineer -in- Charge.
Note : (i) Any copmplaint which is left out/unattendent 1-2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason. (ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA (such as bracket,clamp,nut bolt,Lugs,thimbles,cable clamp ,welding work with connecting acessories etc)
(ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A' and supply issue resolve such as cable loose/disconect connection, No supply issue, short circuit, any other supply issues complain resolve cost shall be deemed including this rate.
(iii) Contractor shall provide the all type of T&P,vehicle, ledder and saftey items such as electric proof shooes and hand gloves, body harnese to electrician for attending & rectification the internal / external electric complaints.
(iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. The rate of such items included in this items.
(v) Any unattended complaints not done in specified time limit. The contractor shall penalty Rs. 500/- on each complaints per day. | 450 | EACH | 200 ₹90,000 | 200 ₹90,000 | 60 ₹27,000 | 100 ₹45,000 |
| 6.00 | M&L for Point wiring for One light point controlled by one way 5 Amps switch/one fan point controlled by one switch & fan regulator with 1.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS dolly concealed conduit in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc. complete all as directed by Enginer-in-charge.
NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items.
(ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates. | 140 | PER POINT | 500 ₹70,000 | 500 ₹70,000 | 360 ₹50,400 | 300 ₹42,000 |
| 7.00 | All as per item No. 06 above but for one 3 pin 5 amp socket on same board all as directed. | 40 | PER POINT | 350 ₹14,000 | 500 ₹20,000 | 40 ₹1,600 | 100 ₹4,000 |
| 8.00 | All as per item No. 06 above but for One 3 pin socket outlet 5 Amps on independent board | 40 | PER POINT | 500 ₹20,000 | 700 ₹28,000 | 360 ₹14,400 | 200 ₹8,000 |
| 9.00 | All as per item No. 06 above but for One bell point controlled by one way bell push switches. | 10 | PER POINT | 500 ₹5,000 | 500 ₹5,000 | 360 ₹3,600 | 200 ₹2,000 |
| 10.00 | All as per item No. 06 above but for One light point controlled by two way 5 Amps switches | 10 | PER POINT | 500 ₹5,000 | 500 ₹5,000 | 390 ₹3,900 | 200 ₹2,000 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
9 Oct 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH, N Area, Pin-160003
REPAIR/MAINTENANCE TO INTERNAL WIRING (CONCEALD) FITTING AND FIXTURES INCL REPAIR /MAINTENANCE OF CEILING FANS ,WALL MOUNTING FANS, GEYSERS, REFRIGERATORS AND ACs AT PCDA OFFICE COMPLEX SECTOR-9A, DAD COLONY SECTOR 35B AND 39B UNDER GE CHANDIGARH.
2025_MES_730671_1
GE/CHD/T-59/2025-26
Open Tender
Electrical and Maintenance Works
270 days
CHANDIGARH
Class D category b(i) for contractor enlisted in MES
8 documents required · 8 mandatory
₹500
GE CHANDIGARH
₹84,000
Yes
30 Dec 2025
12 Sept 2025
11 Oct 2025
12 Sept 2025
9 Oct 2025
27 Sept 2025
13 Sept 2025 - 18 Sept 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including ,fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed.
Taking down existing unserviceable MCB DB/TPN along with MCBs complete by disconnecting all as directed.
Taking down old unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed.
Receiving complaints Daily basis from JE incharge/site incharge lodged by the user/occupants of Internal electric/summer appliance, street light / concern external electric supply nature, rectification of the fault as per the detailed by JE incharge/ AGE E/M to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of Engineer -in- Charge. Note : (i) Any copmplaint which is left out/unattendent 1-2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason. (ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA (such as bracket,clamp,nut bolt,Lugs,thimbles,cable clamp ,welding work with connecting acessories etc) (ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A' and supply issue resolve such as cable loose/disconect connection, No supply issue, short circuit, any other supply issues complain resolve cost shall be deemed including this rate. (iii) Contractor shall provide the all type of T&P,vehicle, ledder and saftey items such as electric proof shooes and hand gloves, body harnese to electrician for attending & rectification the internal / external electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. The rate of such items included in this items. (v) Any unattended complaints not done in specified time limit. The contractor shall penalty Rs. 500/- on each complaints per day.
All as per item No. 06 above but for one 3 pin 5 amp socket on same board all as directed.
All as per item No. 06 above but for One 3 pin socket outlet 5 Amps on independent board
All as per item No. 06 above but for One bell point controlled by one way bell push switches.
All as per item No. 06 above but for One light point controlled by two way 5 Amps switches
All as per item No. 11 above but for one 3 pin 5 amp socket on same board all as directed.
All as per item No. 11 above but for One 3 pin socket outlet 5 Amps on independent board
All as per item No. 11 above but for One bell point controlled by one way bell push switches.
All as per item No. 11 above but for One light point controlled by two way 5 Amps switches
M & L in repair for point wiring for One light/Fan point controlled by one switch with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC casing and capping (ISI Marked) (Approx size 20/25/40mm width) along with all fitting/ fixtures as Tee, Bend, Elbow, socket, Saddles etc.fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wall for mounting the switches , socket outlets , fan regulators etc all as specified and directed.
All as per item no 16 above but One socket 3 pin outlet 5 amp on independent board.
All as per item no 16 above but One 3 pin socket outlet 5 amp on the same board board with other switches.
All as per item no 16 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item no 16 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
All as per above item no 21 but copper conductor 4 Sqmm (nominal area).
Supply for in repair of 2 way Switch modular type single pole one module, 6 Amps complete all as specified and directed.
Supply for in repair Switch modular type single pole one module, 6 Amps complete all as specified and directed.
Supply for in repair of Switch modular type single pole one module, 15/16 Amps complete all as specified and directed.
Supply for in repair of Socket outlet mdoular type, multipurpose, 2/3 pin, single pole two module, 6 Amps complete all as specified and directed.
Supply for in repair of Socket outlet mdoular type, multipurpose, 2/3 pin, single pole two module, 6/16 Amps complete all as specified and directed.
Supply for in repair of Modular bell push single pole one module, 6 Amps complete all as specified and directed.
Supply for in repair of Modular blank plate one module complete all as specified and directed.
Supply for in repair of Modular fan step regulator 120 watts for 48"/56" sweep ceiling fan 2 module complete all as specified and directed.
Supply for in repair of Ceiling rose 3 pin, 230 volts PVC polycarbonate insulated body complete all as specified and directed.
Supply for in repair of Bell ding dong AC 230 volts PVC polycarbonate insulated body complete all as specified and directed.
Supply for in repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply for 4 module (gang box) plastic surface box with plate complete all as specified and directed. .
Supply for 6 module (gang box) plastic surface box with plate complete all as specified and directed.
Supply for 8 module (gang box) plastic surface box with plate complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 1 module complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 2 module complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 3 module complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 4-5 module complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 6 module complete all as specified and directed.
Supply for Modular metal flush terminal boxes with cover plate and frame suitable for 8 module complete all as specified and directed.
S&F in repairs switch piano flush type single pole one way 5 amp complete all as specified and directed.
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified and directed.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type complete all as specified and directed.
S&F in repairs switch socket combination 2 in 1, 5 amp flush type complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type complete all as specified and directed.
S&F in repairs switch bell push, flush type 5 Amp complete all as specified and directed.
S&F in repairs bell, Multi music type AC, 230 Volts single pole complete all as specified and directed.
S&F in repairs fan regulator electronic step type complete all as specified and directed.
Disconnection and removing the u/s LED lamp and S&F invertor LED lamp 15 watts complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED lights fitting 1x 36W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&Fof LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair/replacement of street light bracket made out of 40/32mm dia, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30X6mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed.
S&F in repair of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
All as per above item no. 57 but LED street light fitting 70 Watt 230 V AC .
S&F in repair/replacement of Higher wattage 100W flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection complete all as specified and directed.
All as per above item no. 59 but Higher wattage 150W flood light .
S&F in repair/replacement of Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 22 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size as per site required compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size as per site required compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of UP and DOWN LED light 15 Watt IP- 66 LED complete all as specified and directed.
S&F in repair/replacement of Decorative Globe LED Post Top (25W) LED warm white made in dia cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of Globe LED Post Top (25W) LED wall light in spherical hape polycarbonate diffuser IP 65 protection compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of Ceiling mounted Slim design LED recessed Square Downlight 2x2 LED,36 watt, luminaire to enhance the delight of occupants with comfortable experience through soft illumination compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of surface mounting 2x2 LED,36 watt, luminaire to enhance the delight of occupants with comfortable experience through soft illumination compelte all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of surface mounting 1x4 LED luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination. White powder coated CRCA housing, seamless front frame with flat white high transmission acrylic cover complete all as specified and directed.
S&F in repair/replacement of flexiable pipe for camoflage or sequre of loose wiring with verious size as directed by Engg - in Charge
S&F in repair/replacement of saddle for sequiring of all sizes cables with nut bolts and connected acessories complete all as specified and as directed by Engr-in -charge. Note : Saddle size as per site cable requirment provide by contractor.
S&F VerticleTriple pole and neutral (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB, TPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge.
S&F MCB DB SPN 2 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB SPN 6 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&FMCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F in repair/replacement of MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repair/replacement of MCB SP 5 to 32 ,single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
S&F in repair/replacement of MCB 415V 10KA 'C' Curve TPN 16 To 32 AMP , complete all as specified and directed.
S&F in repair/replacement of MCB 415V 10KA 'C' Curve TPN 40 To 100 AMP , complete all as specified and directed.
S&F in repair/replacement of MCCB 4 pole 63 Amps 16 KA 415 V , complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
All as per above item no. 83 but MCCB 4 pole 100 Amps 16 KA 415 V (Icu = 100% Ics)
All as per above item no. 83 but MCCB 4 pole 125 Amps 16 KA 415 V (Icu = 100% Ics)
S&F in repair/replacement of MCCB 4 pole 160 Amps 25 kA 415 V (Icu = 100% Ics) , with adjustable thermal and adjustable magnetic release, complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
All as per above item no. 86 but 4 pole 200 Amps 36 kA 415 V (Icu = 100% Ics)
All as per above item no. 86 but 4 pole 250 Amps 36 kA 415 V (Icu = 100% Ics)
All as per above item no. 86 but 4 pole 350 Amps 36 kA 415 V (Icu = 100% Ics)
S&F in repair/replacement of S&F Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Material and labour for repair of LT Panel/MCCB DB/MCB DB/Bus Bar Chamber making electric connections incl wiring by Conductor multistranded PVC insulated welding of doors , fixing hinges, Thimble Refixing of MCCBs and brazing etc incl complet all as specified and diercted by Engineer-in-Charge.Note:Rusted/Broken/Loses all types Door for Panel/DB/Busbur are provided cost shall be deemed including this rate.
Sub main wiring in replacement (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable 2.5 sqmm two runs of main cable) alongwith one run of single core 2.5 sqmm FRLS PVC insulated flexible stranded copper Conductor 1.1 KV grade of earth for earthing drawn in suitable PVC conduit/ concealed conduits/casing caping as per site required including Cutting chases in existing wall for laying of PVC conduits including making good disturbed surfaces with painting of wall matching with exisiting colour after concealing the conduit in wall with size 2 run of 2.5 Sqmm cable + 1 run of 2.5 Sqmm all as specified. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length
All as per above item no. 92 but 2 run of 4 Sqmm cable + 1 run of 4 Sqmm
All as per above item no. 92 but 2 run of 6 Sqmm cable + 1 run of 6 Sqmm
All as per above item no. 92 but 2 run of 10 Sqmm cable + 1 run of 10 Sqmm
All as per above item no. 92 but 4 run of 6 Sqmm cable + 1 run of 6 Sqmm
All as per above item no. 92 but 4 run of 10 Sqmm cable + 1 run of 10 Sqmm
S&F PVC insulated and FR PVC Round Sheathed 2core 1.5sqmm, Copper Conductor(flexible) industrial cable, 1100 Volt, conforming to IS 694 for sub main wiring drawing through PVC casing and capping/ saddling by saddle/under PVC condute complete all as specified and directed by Engineer-in-Charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 6 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular.saddling by saddle/under PVC condute complete all as specified and directed by Engineer-in-Charge.
All as per Item No 99 here in above but of aluminium conductor 2 core 4 sqmm.
M&L Making of square / circular hole in the stone masonry/Brick/wooden/alluminium wall or window suitable for fixing exhaust fan of 150/250/320 mm sweep.including M.S Frame work of suiable size with nut,bolts etc and sealing the sides of exhaust fan complete all as directed.
S&F exhaust fan of size 300 mm sweep metal body 900RPM with metallic louvers, working on single phase 230V AC Supply complete with nut and bolts complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note : The unit rate includes for protecton pipe 15mm and GI earth strip/steel earth wire 4mm from top of earth plate upto 7.50 metre above ground level.
Taking down ceiling fans of 1200 to 1400mm sweep and make after disconnecting from ceiling rose, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp,rubeer reels with nut, bolt split pin, and shaft, sleeves, rewinding, testing, rehanging and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for separately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain the signatures of user after satisfactory complition of work
Taking down exhaust fans of any sweep and make after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain thre signatures of user after satisfactory complition of work
Taking down Wall mounted/Pedestal fans of Sweep 300 to 450mm, 230 volts of any make & size after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain the signatures of user after satisfactory complition of work
M&L replacement of unserviceable capacitor 2.5/3.15 mfd provided with new capacitor oil type 2.5/3.15 mfd suitable for 440 volt AC Complete all as specified and as directed by Engineer-in-charge.
All as item No 107 here in above but of Capacity 4/4.5 MFD, AC 440 volts.
M&L rewinding to ceiling fan motor of 1200 to 1400mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves & paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block complete all as specified and as directed by Engineer-in-charge. Note :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account
All as item No 109 here in above but for Exhaust fan 225 to 300mm sweep.
All as item No 109 here in above but for Exhaust fan 350 t0 450mm sweep.
All as item No 109 here in above but for Pedestal / Wall mounted fan upto 450mm sweep.
Supply only Ball bearing suitable for celing fans of any sweep.
Supply only gun metal bush suitable for celing fans of any sweep.
Supply only Mild steel shaft suitable for celing fans of any sweep.
Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting
Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
M&L for replacement of unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of unserviceable fan blades (set of three blades) suitable for 1200/1400/1500mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm/1500mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint of existing colour with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.
M&L lathe work for taking out bush from the lower body part of ceiling/Exhaust fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft complete all as specified and as directed by Engineer-in-charge. Note : - Supply only Bearing shall be measured and paid separately under respective item of this Schedule.
Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 127 here-in-before but 50 litre capacity.
S&F replacement of unserviceable Stain less steel inner tank of 25 litre capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 129 here-in-before but 50 ltr capacity.
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
All as per above item No 131 here-in-before but 1500 watt.
Replacement of unserviceable Safety valve
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union
Replacement of unserviceable Gun metal non return valve ,15 mm bore
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends for hot water fixed to GI Pipe complete and all as specified.
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends for cold water fixed to GI Pipe complete and all as specified.
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre.
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.
Replacement of 3-Pin plug top, 16 Amp, 230volt AC
Replacement of Rubber 'O' ring /gasket for 25 ltrs
Material & labour for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
Material & labour for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for Geysers of any capacity complete all as specified and as directed by Engineer-in-Charge .
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
S&F for sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 25Amp 240 Volt including MCB SP,20Amp as in repair complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
Taking down to 15mm bore steel tubing and connection including cleaning for re-fixing or remove from site complete all as directed by Engineer-in-Charge.
S & F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
(WATER COOLER) Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Make : SRI-RAM/ TAKAM SHAH/ KIRLOSKER .
All as per above item No 153 hereinbefore but water cooler of capacity 40/80 litres. Note for item No 153 & 154: (i) Contractor shall produce original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.
All as per above item No 155 here-in-before but water cooler of capacity 40/80 litres
Supply and fixing internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge
All as per above item No 158 hereinbefore but water cooler of capacity 40/80 liter
Supply and fixing in repair of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 160 here-in-before but water cooler of capacity 40/80 litre
Supply and fixing in repair of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 162 hereinbefore but water cooler of capacity 40/80 liter
Replacement to unserviceable Condenser unit with new condenser unit of existing make and model suitable for water cooler of capacity 150/180 liters, complate all as specified and as directed.
All as per above item No 164 here in before but water cooler of capacity 40/80Liters.
Supply and fixing in repair 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler complete all as specified and as directed by Engineer-in-Charge.
Cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 167 here-in-before but water cooler of capacity 40/80 liter
Supply and fixing in repair of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
(REFRIGERATORS) Disconnecting & opening refrigerator of capacity 180/210/320 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :SRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .
Recharging of gas R-10/12/134A in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
Replacement of freezer door plastic with tension spring as per existing model suitable 160/210 litre cap.
Replacement of Door liner ( Plastic ) for upto 310 liter capacity
Replacement of Door magnetic gaskest for upto 310 litre cap.
Replacement of Relay box type for any cap.
S&F replacement of unserviceable over load protector with new over load protector suitable for refrigerator 165 to 310 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
(SPLIT TYPE AND WINDOW TYPE AIR CONDITIONER) Disconnection and removing the unserviceable Split AC Outdoor & Indoor Unit/ window type of Capacity 1.5 to 4 Ton capacity from the existing position carefully for finding of the defects and to replace the unserviceable spare parts such as Compressor, Condensor fan mtor, condensor coil, suction & discharge valves, mother plates including carry out leak detection test, Gas charging, servicing such as cleaning and removing the dust particles accumulated in the unit and filters carefully and washing the cooling unit and Indoor unit with water and refixing the same in its original position complete including connecting up of the Copper Tubes and cable connections, testing and commissioning complete all as specified and as directed by Engineer in charge. (i) Cost of spares such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates, leak detection test, Gas charging shall be measured and paid separately under the respective Schedule. (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing ACs.
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 1.5 Ton Single Phase for Split Type ACs complete all as specified and directed by Engineer in charge. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier
Supply only indoor sealed Compressor Unit of Capacity 1.5 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 2 Ton Single Phase for Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier
Supply only indoor sealed Compressor Unit of Capacity 2.0 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier
Supply only sealed Compressor Unit of Capacity 4 Ton Single Phase for Standing Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star/Tikam Shah/Carrier
Supply only Condensor Fan Motor 230 Volt suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Fan Motor 230 Volt suitable for 2 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG:/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for window type AC of 1.5 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for window type AC of 2.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for Standing Split type AC of 4.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for Split type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for window type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for Standing Split type AC of 4 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit made out of Copper tubing suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 2 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit made out of Copper tubing suitable for 4 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only PCB/ Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2/4 Ton Indoor Unit of Split Type Air Conditioning complete all as directed.
Replacement of broken Fan Blade from the Outdoor units of Split AC Unit 1.5 / 2 /4 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit.
Replacement of running/starting capacitors from the Outdoor units of Split Type AC Unit 1.5/2/4 Ton Capacity and S&F new Capacitors of capacity 36/46/50 MFD, 230 Volts, ISI Marked.
Replacement of Display Unit for indicating Temperature, Temperature Sensor for 1.5/2/4 Ton Split AC Unit complete all as directed. Make :- LG/Hitachi/Voltas
Supply and Charge Refrigerant (R-22)/410a/407C Suitable for existing 1.5 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Supply and Charge Refrigerant (R-22)/410a suitable for existing 2 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Supply and Charge Refrigerant (R-22)/410a suitable for existing 4 Ton Capacity Standing Split type air conditioning unit complete all as directed.
Replacement of Standard Flexible PVC Drain Pipe of dia 25mm for capacity 1.5 ton, 2.0 ton & 4 Ton capacity complete all as directed.
Disconnection and removing the old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer in charge.
All as per Item No 204 here in above but size 1/4" dia
Supply and fix Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply and fix Suction Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply and fix Suction Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed.
Supply and fix Discharge Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply and fix Discharge Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply and fix Discharge Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed.
Disconnection and Removing the defective / damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled by 01 No 15/16 Amp Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity compelte all as specified and directed by Engineer-in-Charge.
Disconnection and Removing the Cable connections and Copper Pipe alongwith all connected items carefully from the existing indoor and out door units and Pumpdown the refriegerant from Outdoor Unit of tonnage 1.5/2/4 Ton including stabilizer from the existing positions and shifting the AC unit at new place and refixing the outdoor and indoor units with necessary copper tubing including topping up of gas and connecting stabilzer etc for its proper functioning complete all as directed.
Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- 1 The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit. 2 The cost of refrigerant will be measured and paid separately under rhe respective Schedule A Item.
Disconnection and removing the unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multistranded Copper Cable 3 Core 4 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials compelte all as specified and directed by Engineer-in-Charge.
All as per item No 215 here in above but with 2x6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.
Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 1,33,667.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
Jai Maa Electrical Works (BID ID -3440797)
GS Engineers (BID ID -3440877)
LA ENTERPRISES (BID ID -3440860)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid