Loading…
Loading…
Tender ID
Tender Value
₹2.1 Cr
EMD Value
₹2.1 L
Closing Date
16 Mar 2026, 5:00 pmClosed
Assistant Manager, North Zone
CONSTRUCTION Of SKATING RINK & BOX - CRICKET AT NARODA-2 T.P.S NO-40,F.P NO-35
282558
Notice No. 18, Tender No-135
Open
Civil - All
Works
Ahmedabad
4 documents required · 4 mandatory
₹3,600
Municipal Commissioner, Ahmedabad
₹2.1 L
3 Mar 2026
3 Mar 2026
3 Mar 2026
16 Mar 2026
3 Mar 2026
Name of Work: CONSTRUCTION Of SKATING RINK & BOX -CRICKET AT NARODA-2 T.P.S NO-40,F.P NO-35
Volume -II Financial BID
Ahmedabad Municipal Corporation
Rajiv Gnadhi Bhavan
Memco, Ahmedabad-382345
AHMEDABAD MUNICIPAL CORPORATION
MAHANAGAR SEVA SADAN - NORTH ZONE
Name of Work: CONSTRUCTION Of SKATING RINK & BOX -CRICKET AT NARODA-2 T.P.S NO-40,F.P NO-35 Bill of Quantities
SR. TOTAL SOR RATE
ITEM DESCRIPTION UNIT AMOUNT
NO. QTY 2024-25
Excavation for foundation upto 1.5 m
depth including sorting out and stacking
1 of useful materials and disposing off the cmt 1968.00
excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Excavation for foundation for depth from
1.5 mt 3.0 m including sorting out and
2 stacking of useful materials and cmt 273.00
disposing off the excavated stuff upto
Meter lead.(A) Loose or soft soil
Conveyance charges of earth lime,
murrum, building rubbish, manure,
3 garbage, sludge, excavated rock, fly ash, cmt 220.00
aggregate of any kind etc. comp. upto
Extra For Lead Above 5 km &upto 6 km cmt 44.00
Extra For Lead Above 6 km &upto 7 km cmt 44.00
Filling available excavated earth
(excluding rock) in trenches. plinth, sides
of foundations etc. in layers not
exceeding 20 cm. in depth consolidating
each disposited layer by ramming and
Filling in plinth with sand under floors
5 including watering ramming, cmt 228.00
consolidating and dressing complete
Filling in foundation and plinth with
murrum or selected soil in layers of
6 20cm. thickness including watering, cmt 228.00
ramming and consolidating etc.
Carring out plinth treatment to post
construction /existing structure by
spraying chemical solution for termite
control treatment including labour and
material consistment with I.S.I
specification. Using Chlordene and
Chiorpurfiles 20 EC. As Per 6131_paret-II
Consentration Weight one percent is
recommended i.e one litre 20 EC
chemical emulsion with 19 liter give 1%
concrentration inclusive of one litre
chemical emulsion appication at the rate
of 5 Litre chemical /Sqm of sur face is
recommended as per I.S
Providing and laying cement concrete
1:3:6 (1-Cement:3-coarsesand:6-hand
broken stone aggregates 40mm nominal
size)and curing complete excluding cost
of formwork in (A) Foundation and
Providing and laying controlled cement
concrete M.250 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete
work in (A) Foundations, footings, Base
of columns and Mass concrete. FOOTING
Providing and laying controlled cement
concrete M.250 and curing complete
excluding the cost of formwork and
10 reinforcement for reinforced concrete Cum 34.00
work in (A) Foundations, footings, Base
of columns and Mass concrete. BELOW
Providing and laying controlled cement
concrete M.250 and curing complete
excluding the cost of formwork and
11 reinforcement for reinforced concrete Cum 23.00
work in (D) Columns, Pillars posts and
struts, upto floor two level.GROUND
FLOOR ABOW PLINTH COLUMN
Providing and laying controlled cement
concrete M.250 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete
Slabs,landing,shelves,Balconies, Lintels,
Beams, Girders and Cantilever upto floor
two level. plith beam
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete
Slabs,landing,shelves,Balconies Lintels,
Beams, Girders and Cantilever upto floor
two level. GROUND FLOOR
Providing TMT Bar FE 500D
reinforcement for R.C.C. work including
bending, binding and placing in position
complete upto floor two level
Providing formwork of ordinary timber
planking so as to give a rough finish
including centering shuttering strutting
and propping etc. Height of propping and
centering below supporting floor to
ceiling not exceeding 4 M. and removal of
the same for in situ reinforced concrete
and plain concrete work in. (A)
Foundations Footings Bases of Columns
etc. and Mass concrete. FOOTING
Providing formwork of ordinary timber
planking so as to give a rough finish
including centering shuttering strutting
and propping etc. Height of propping and
centering below supporting floor to
ceiling not exceeding 4 M. and removal of
the same for in situ reinforced concrete
and plain concrete work in. (B) Flat
surfaces such as soffits of supspened
floors slabs Landings and the like. (1)
Floors etc. upto 200 mm in thickness.
Providing formwork of ordinary timber
planking so as to give a rough finish
including centering shuttering strutting
and propping etc. height of propping and
centering below supporting floor to
ceiling not exceeding 4 M. and removal of
the same for in situ reinforced concrete
and plain concrete work in. (G) Columns
PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan. COLUMN
Providing formwork of ordinary timber
planking so as to give a rough finish
including centering shuttering strutting
and propping etc. height of propping and
centering below supporting floor to
ceiling not exceeding 4 M. and removal of
18 the same for in situ reinforced concrete Smt 562.00
and plain concrete work in. (H) (2) Sides
and soffits of Beams Beam
Haunchingscanti-levers Girders
Bressumers and Lintels exceeding 1M.in
Depth.PLINTH BEAM & SLAB BEAM &
Brick work using common burnt clay
building bricks having crushing strength
19 not less than 35 kg./Sq.Cm. in foundation Cum 10.00
and plinth in Cement Mortar 1:5. (1-
Cement : 5 -fine sand)(B)Conventional
Brick work using common burnt clay
building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1-
Cement : 5 -fine sand)(B) Conventional
Extra for brick work in superstructure
above plinth level upto floor two level
(B) Conventional : Ground Floor
(i) Half brick masonry in common brunt
clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:4 (1- Cement : 4 -
21 coarse sand ) in foundation and plinth Smt 23.00
(B) Conventional Extra for half brick
masonry in superstructure above plinth
level upto floor two level. (B)
Conventional GROUND FLOOR
Providing 15mm thick cement plaster in
single coat on Rough (Similar)side of
single or half brick walls for interior
22 plastering upto floor two level and Smt 60.00
finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) GROUND
Providing 10mm thick cement plaster in
single coat on brick/concrete walls for
interior plastering upto floor two level
and finished even and smooth in (ii)
23 Cement mortar 1:4 (1- cement :4-sand) Smt 31.00
Extra over items 58 to 71 for plastering
on ceilings and sofits of stairs up to floor
two level instead of plastering on
Providing 20 mm thick double coat mala
cement plaster on interior brick /
concrete work for plastering comprising
of base coat of 12 mm thick cement
plaster in cement mortar (1 Cement :
coarse sand) in rough finishing and 8 mm
thick top coat of cement mortar 1:2 (1
Cement : 2 Coarsesand) finished with
trovel including scaffolding curing etc.
20mm thick sand faced cement plaster
on walls upto height 10 metres above
ground level consisting of 12mm thick
backing coat of C.M. 1:3 (1-cement : 3-
sand) and 8mm thick finishing coat of
C.M. 1:1 (1-cement : 1-sand) etc.
Providing and applying 2mm thick
Texture Plaster Terre Plaette (Specturm
Coral or equivalent) incoprating fine
fillments made of polymer and
aggergating natural stone powder with
26 making grooves on base coat of 20 mm Smt 137.00
thick smooth mala plaster (which paid
seperately) etc. complete.Colour and
shade as approved by Architect/
Engineer in charge for at all floor ,all
Providing cement vata (10cm. x 10 cm.
size) quarter round in cement mortar 1:1
including neat cement finishing, watering
Applying two coats of putty & two coats
of primer of approved brand and
manufacture on new wall surface to give
28 an even shade including thoroughly Smt 91.00
brushing the surface free from mortar
dropping and other foreign matter and
sand papered smooth.
Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture on undecorated wall
29 surface to give an even shade including Smt 91.00
throughly brushing the surface free from
mortar droppings and other foreign
matter and sand papered smooth.
Finishing wall with weather proof
exterior emulsion paint on wall surface
(two coats) to give an required shape
even shade after thoroughly brushing the
surface to remove all dirt, and remains of
loose powdered materials.etc complete
Providing and laying Ceramic tiles 6mm
thick in flooring treads of steps and
landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3- coarse
sand ) finishing with flush pointing in
P & L 24" x 24" vitrified 8 mm thick tile
flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on
existing flooring by adhesive material
including dismentaling of existing
flooring and jointed with color cement
slurry including finised with flush
pointing & cleaning the surface etc.
complete for light shade
P&L 24"x24" vitrified 8mm thick tile
flooring over 20mm (average) base of
cement mortar 1:6 (1cement :6 coarse
sand) on new surface or fixing one
xisting flooring by adhesive material
including dismentaling of existing
flooring and jointed with color cement
slurry including finised with flush
pointing & cleaning the surface
etc.complete for antiskid
Providing and laying white glazed tiles
6mm thick in skrting risers of steps and
34 dedo on 10 mm thick cement plaster Smt 35.00
1:3(1-cement :3-coarse sand)and jointed
with white cement slurry
Providing and laying Granite slab (18
mm thick) one side polished flooring
over 20 mm (average) base of cement
35 mortar 1:6 (1 cement : 6 coarse sand) or Smt 50.00
L.M 1:1.5 laid and jointed with grey
cement slurry including rubbing and
polishing complete.
Providing and laying 18 mm thick
polished granite stone machine cut in
single piece (Max. available) in sill and
jambs of door ,window,ventilation& lift
wall cladding,staircase flooring landing,
risers & treads, skirting laid over 10 mm
thick cement mortar 1 : 3 (1 cement :
coarse sand) and jointed with grey
cement slurry with matching pigment
incl. rubbing and polishing,half rounding
edge and incl. fixing of hilty fastener at
every 1/3 span of sill as required size etc.
complete colour and shed as approved by
architect engineer in charge.
Providing and fixing M.S. grills of
required pattern to wooden frames of
windows etc. with M.S. flats at required
spacings and frame alround, square or
round bars with round headed bolts and
nuts or by screws (A) Plain Grill.
Providing and fixing standared extruded
of alluminium section of size 63mmx
38 with colour anodized alluminium frame Smt 1.00
for ventilation with 5mm thick frosted
glassas details etc complete for
Providing and fixing window having
extruded aluminum Colour Powder
Coated section frame main outer size
Rmt, horizontal two track member size
0.695 Kg/mt, vertical member of size
0.0.659 Kg/mt with sliding shutters of
39 horizontal member size 40mm x 18mm x Smt 4.00
1.29mm @ wt.of 0.456Kg/mt, vertical
member of size 40mm x 18mm x 1.29mm
@ wt.of 0.456Kg/mt with 5 mm thick
transparent bronze colour tinted float
glass with powder coated aluminum
fittings and fixtures and transparent
silicon sealant glass fixing to frame as per
complete for window
Providing and fixing flush door both
sides laminated and I.T.W. beading all
around by using I.T.W. frame 120 m.m. x
80m.m.. shutter 35 mm thick solid core
malemine faced three layered pre
laminated flat pressed wood based
exterior grade bonded BWP/BWR
synthetic resin having stamped IS
grade I type II including three coats of
lacquer polishing to exposed wooden
surfaces and Stainless steel decorative
type designs fixtures / fastening
etc.including I.T.W. triangular batten
patti of size 30m.m.x30m.m.etc. as per
architectural detailed drawing and as
directed by engineer in charge.
Providing and fixing FRP frame size
125x65mm and 35 mm thick FRP shutter
with wood grain raised panneledde sign
finish shutter having extra reinforcement
on sides & edges in Gel coat finish. The
core of the shutter & frame is to be filed
up with injected polyurethene foam done
41 in situa long with embedded wooden Smt 4.00
pieces for stiffening & also taking hinges
&fintures. The whole FRP frame &shutter
is to be water proof weatherproof
,termite proof & resistance to mild
acid/alkali. Rate sare to be inclusive of
S.Shinges with fastener sleeve
&alluminium fixtures & fastenings.
Providing & applying CHEMICAL WATER
PROOFING treatment to the terrace
including Surface cleaning: All surface
shall be thoroughly cleaned with
mechanical means or wire brush to
remove dust dirt & all loose portion from
the surface of terrace & parapet wall.&
wash with water. Surface preparing: All
cracks will be opened in V-shape &
sealed wirh Dr Fixit Crack X Paste & any
patch work will be repaired with
polymer modified mortar, providing and
applying two coat of Dr.Fixitpidifine 2K
on entire inside area of sunk. Two coat of
Dr.fixitpidifine 2K(10 kg Powder + 5 lit
Liquid) shall be applied on ready surface
in vertically & horizontally direction
which is brsh applied waterproofing
coating & provides excellent
impermeable coating & flexible enough
to take care of minor cracks in concrete &
plaster & good adhesion with
cementitious surfaces etc. completed by
Providing and laying broken chine
mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to
be laid over cement mortar 1:3 to plain
or slope and to be tempered to bring
mortar creme out upto surface using
white cement including rounding off
junctions and extending them upto 15 cm
along the wall,clearing with water and
oxalic acid etc. as directed.
Structural steel work ( Confirming to IS
4923-1997) riveted, bolted or welded in
builtup for all type sections, in framed
work, including cutting, hoisting, fixing in
position and applying a priming coat of
approved steel primer all complete as
per the structural designs and directions
of Engineer in charge.
Painting one coats (excluding priming
coat) on previously printed steel and
other metal surface with synthetic
enamel paint, brushing to give an even
shade including cleaning the surface of
all dirt, dust and other foreign matter.
Paver Block Providing and laying shot
blasted Non - interlocking, Paver blocks
of specified thickness, size, grade of
concrete and colour machine made and
blasting by automatic shot blasting
machine and high density of as per
approved sample of approved make for
footpath, parking areas, service
lanes,cross over and other areas as
mentioned in the drawing. Including
providing and laying 50 mm thick
averave bedding layer of coarse sand
below paver block as per required
grading and specification. Laid paver
block shall be mechanically compacted.
46 The work of the paving blocks shall be Smt 385.00
executed in line and level by skilled
mason of flooring work only. Small size
of paver block with same specification
shall be used at residue or at end. It
should be laid in such a way that the no
cutting of the paver block to be
necessary. If cutting of paver block shall
be required , than cut by machine only
and laying to be done by skilled flooring
mason. The finished surface of the paver
block shall have coarse sand Texture
Finish. Pave blocks shall be compacted
and shall be re-laid if necessary. Actual
laid area shall be measured and paid
without any wastage.
Pre cast concrete kerb Providing and
fixing M25 Grade of concrete precast
exposed / Fair finish / texture finish kerb
stones of approved make as per
approved sample of any size and any
type. Kerbs shall be fixed on the
foundation prepared as per approved
design. The rate shall also include for
erecting and fixing the pieces in position
for complete kerb system with
chamfered type of kerbs including
47 necessary accessories of kerb like radius Rmt 550.00
kerbs, angles and quadrant kerbs,
droplet kerbs etc. complete as per
drawing. Kerb shall be fixed as paper
joint without any jointing material.
However cement mortar shall be
provided at the backside of kerb stone
joint. (Sample must be approved) Cost of
excavation, cutting , base , side filling
shall includes as directed engineer -
incharge in above item description as per
BOQ (b) 380 x 600 x 150 mm high
Footpath kerb. As per approved rate
Providing & Laying P21(water reducing
concrete admixture at 100 ml per bag of
cement & recon 3 s fiber at 125 gm per
bag of cement including making C
channel 75 x 75 mm required to maintain
level,slope and thickness of the concrete
road leveling of placed concrete with
surface vibrator and finishing with
power floater & trowel light brooming
the surface & Groove cutting & filling of
expansion joint as directed by Engineer
Providing, laying, spreading and
compacting Wet Mix Macadam (as per
table 400 - 10 and 400 - 11) of well
graded stone aggregate to specification
including premixing the Material with
water at OMC in mechanical mix plant as
per approved design mix, carriage of
mixed material by Tipper to site, laying
49 in uniform layers with motor Cum 790.00 1710.00
grade/Front end Loader/paver finisher,
in sub base/base course on a well
prepared under base and compacting
with vibratory roller to achieve the
desired density including lighting,
guarding, barricating and maintenance of
diversion etc. (MoRTH specification :
Clause 406) by mechanical means
Providing and laying rubble soling, 23 cm
thick, in a compact manner, foudation,
road, footpath etc. using 200 to 230 mm.
cut size stones, covering and levelling the
50 surface with a layer of murrum after Cum 1700.00 1039.37
filling the voids with smaller sized stones
or stone chips, including watering,
ramming well and consolidating each
layer, as directed.
Providing and laying of Hot applied
thermoplastic compound 2.5 mm thick
including reflectorizing glass beads and
250 gms per Sq.m. area thickness of
mm is exclusive of surface applied glass
beads as per IRC-35 2015. The finished
surface to be level/uniform and free from
streaks and holes or chipping of
Thermoplastic if any and including
primer coat for C.C. surface and A.C.C.
surface, in white and/or yellow colour.
51 Rate includes brushing, blooming and Smt 18.00
cleaning and application of paint. Zebra
patta/Bump patta/Lane line/Center
line/Cut patta, Directional Arrow,
Lettering MoRT&H Clauses 803 &Volume
II Part III and IRC 35-2015.Rate shall
include brushing, brooming, painting and
repainting of worn out paint after a
period of 2.5 years.
Note:-As per drawings and design
supplied by architect and instruction
given by authority and E.I.C.
Providing & Fixing the Chikenmesh -
guage(Crimp Jali) of approved size
applying between the RCC and masonry
junction in proper line, level and plumb
with all material, labour, tools, tackles
and equipment. Including providing and
fixing the jali with nails, etc complete as
directed by the site-incharge.
Providing and fixing 1.20 Metre high
fencing with 2.0 Metre long M.S. Angle
posts 40mm x 40 mm x6 mm and oil
painting 3 coats fixed at 2.5 Mt,C/c. with
five Horizontan lines and two diagonals
53 of galvanised steel barbed wire RMT 258.00
weighting 9.38 Kg. per 100 Metre,
strained and fixed to posts with
G.I,staples including fixing the postsin
ground with 0.5 M x 0.5.M x 0.5 M. block
in C.C1:5:10 etc complete.
A polyethylene lawn is a surface made of
synthetic fibers manufactured from
polyethylene (PE) plastic, designed to
look and feel like natural grass. It is a
54 type of artificial turf commonly used in SMT 660.00
residential and commercial landscaping,
sports fields, and recreational areas due
to its durability and low maintenance
Point wiring for Light / Bell with 2-1.5
sq.mm &earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires,
in following type of pipe to be erected
concealed in/ on surface on wall/ceiling
complete with 6A Modular type switch /
bell push & accessories and earth
continuity of following type, erected on
PVC / Metallic box, single mounting base
frame covered with textured/metallic
front plate modules erected on / in wall
/ ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose /
H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
(a) with medium class Rigid PVC pipe
56 and accessories erected flushed on Pt 3 467.25
wall/ceiling complete CAT-III
Point wiring for Modular secondary light
point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi
strand copper wires, in below type of
pipe to be erected complete with earth
continuity and necessary connection
with primary light with accessories
erected on Metal / PVC / wooden box
covered with 3 mm thick
PC(Polycarbonate) / Acrylic sheet for
open / concealed wiring. with necessary
Lamp holder / ceiling rose /
H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete - Note:- Maximum
up to 6 mtrs length, excess will be
considered as Mains for Secondary
(a) with medium class Rigid PVC pipe
58 and accessories erected flushed on Pt 3 137.55
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm
&earthwire of 1.5 sq.mm (Green) both
are of .ISI marked 1.1 KV Grade ZHFR
PVC insulated multistrand copper wires,
in following type of pipe to be erected
concealed in / flushed on wall/ceiling
complete with 6A Modular type switch
and hum free EME four or more step type
electronic fan regulator with separately
mounted and accessories with earth
continuity of following type erected on
PVC / Metallic box, single mounting base
frame covered with textured/metallic
front plate modules erected on / in wall /
ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC
pipe and accessories erected concealed
in wall/ceiling complete
Providing following type of Modular
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
60 metallic/white front plate , modules Ea 50 179
erected with necessary connections as
per site situation directed by Engineer In
charge. (9) 16 Amp. SP one way switch
61 (2) One No 6 pin plug Cat.III Ea 5 150
62 (10) 6/16Amp. Universal socket Cat.III Ea 20 198
Providing & erecting Switch board for
Computer or electric apparatus
consisting of following items in single
board erected on PVC / Metal board
with 3 mm thick PC (Polycarbonate) /
63 Acrylic sheet erected as directed for Ea 2 1122
[B] modular type accessories
1 no. 6A/16A universal plug-switch
combined. CATIII
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
MAINS WIRING AND CONDUIT
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or
ceiling erected with necessary PVC
fittings & Junction boxes fixed with
adhesive solution & Clamps with
following dia of pipes, in approved
manner as directed
Providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in
following type of pipe to be erected
66 concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green
colour for earth continuity of following
(A) With medium class Rigid PVC pipe
and accessories
68 (a) 2 wire 1.5 sq. mm Mtr. 200 62.00
69 (b) 2 wire 2.5 sq. mm Mtr. 200 82.00
FANS & EXHAUST FAN ACCESSORIES
Providing & erecting Approved make
Power Saving 50 Watt Ceiling Fan with
double ball bearing ISI mark with
Condenser 230 volt A.C. 50 Hz 1200 mm
70 sweep complete having 3blades with Ea. 1 1,929.00
aluminium blades with , canopy & 30 cm.
down rod erected with earthing.(Make
shall be approved by Engineer in
Supplying and erecting 19 / 20 mm.
nominal bore Medium Class M.S. Pipe
71 down rod erected duly painted for fan Mtr 1 107.00
complete with necessary 24/ O.20, 3 core
flexible wire with earthing.
Supplying & erecting fan hook box of
mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and
72 pierced through a 16 Gauge M.S. box / Nos 1 107.00
Heavy Duty PVC box complete erected
concealed in Ceiling with necessary
Supplying & erecting approved make low
noise decorative Exhaust fan having size
73 200mm with 1350 RPM with square Nos 2 1,687.00
frame ABS body with inbuilt lowers &
LIGHTING FIXTURES :
Supplying and erecting led lamps with
following wattage capacity of 220 to
voltage, minimum 15000 burning hours
life, 500 V in built-surge
74 protection,Polycarbonate diffuser, EA 5 187.00
mounting suitable for E14 / E27 / B22
lamp holders, pf >= 0.5. (A) LED Lamps
integral type, with PC diffuser suitable
LAMP holder. (iii) 10 to 15 watts. Cat-III
Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be
made of thick sheet Steel conforming to
IS: 513/CRCA/aluminium pressure die
cast powder coated and high U.V. &
corrosion resistance with diffuser
housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description
have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge
may select any wattage capacity between
the ranges shown.). (A) Square/ Circular
shaped Surface/Recessed Mount
Downlight with provision for spring
loaded mounting clips complete.IP20.
(iii) 16-20 watts, Surge-2 KV. Cat-lll
DISTRIBUTION BOXES
Providing and erecting Sheet Steel
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs
should be used of same company of MCB
to be used) suitable for. (A) single phase
incoming and horizontal single phase
outgoing. (iii)Single phase 8 way SS
Providing and erecting Sheet Steel
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486- Ea. 1 2,316.00
1986 without MCB to house appropriate
nos. of MCBs i) Three phase 4 way SS
Double door for horizontal single phase
Providing and erecting Sheet Steel
powder coated MCB distribution board -
flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486- Ea 1 3,836.00
1986 without MCB to house appropriate
nos. of MCBs iv) Three phase 12 way SS
Double door for horizontal single phase
MINIATURE CIRCUIT BREAKER
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996
25 Cat.III Ea. 34 111.00
Providing & erecting 240 V MCB double
pole switch for lighting Load (B Curve)
26 having 10 KA breaking capacity &
confirms to IS : 8828 in existing box
having following capacity
27 (A) 6 to 32 Amp.
28 Cat.III Ea. 1 276.00
Providing & erecting 415V MCB Four
Pole Switch for Lighting Load (B curve)
29 having 10KA breaking capacity &
confirms to IS :8828 in existing box
having following capacity
31 Cat.III Ea. 1 730.00
Approved make ELCBs / RCCBs
conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 6 KA and suitable
for operation on single phase 240 V.
33 having characteristic of quick action & Ea 1 1,950.00
tripping with all advance feature & do
not incorporate any electronic
component. for following Max. rating
erected as directed (i) 25 Amps.DP Cat.
Approved make ELCBs / RCCBs
conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 6 KA and suitable
for operation on single phase 240 V.
34 having characteristic of quick action & Ea 3 2,213.00
tripping with all advance feature & do
not incorporate any electronic
component. for following Max. rating
erected as directed (ii) 40 Amps.DP Cat.
Providing and erecting XLPE(IS:7098)(I)-
88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in
existing trench / pipe of following size of
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm
Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe of
following size of cables
(A) 4 core 16 Sq. mm Mtr. 50 152.00
(B) 4 core 25 Sq. mm Mtr. 50 189.00
Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor
for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe of following size of cables
(C) 4 core 10 Sq. mm Mtr. 600 139.00
Providing and erecting XLPE(IS:7098)(I)-
88 ISI armoured cable multistrand /
Solid Copper conductor for 1.1 KV. to be
laid on wall with necessary clamps or in
existing trench / pipe at road crossing
or floor of following size of cables.
(B) 4 core 4 Sq. mm Mtr. 50 361.00
(C) 4 core 6 Sq. mm Mtr. 50 505.00
Making trench in soft soil of suitable
width of 90 cm deep for laying cable or
39 locating the fault all over the run and Mtr. 400 55.00
back filling the same and making the
surface as normal ground.
Providing & laying approved make
Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS
II )with necessary connecting
accessories of same material at required
depth in existing trench for laying of
cable. below ground / road surface for
enclosing cable
41 (A)50 mm outer dia Mtr. 200 62.00
42 (B)63mm outer dia Mtr. 300 73.00
Providing and, fixing heavy duty flange
type brass cable gland with rubber ring
43 for PVC insulated armoured cable
complete with out going tails, insulating
tape etc for following size of cables.
45 (C) 2 to 4 core 10 Sq. mm Ea. 60 38.00
Providing and, fixing heavy duty flange
type brass double compression type
cable gland with rubber ring for PVC
insulated armoured cable complete with
out going tails, insulating tape etc for
following size of cables.
Solder less crimping type Aluminium lugs
49 conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated
nut bolts in an approved manner.
EXTERNAL STREET LIGHT
Street Light Pole
Supply of approved make GRP / FRP Pole
having following specifications: GRP
Light Pole made by CNC filament winding
machine using thermoset resin
polyester/epoxy resin system) having
minimum 62% glass content. The pole
should be in one piece and tapered round
in shape, having smooth finish and
should be totally free from corrosion as
well as non conductive& shock proof Pole
should be provided with FRP Anchor
Base and it should be heavy duty, or MS
Material duly painted with Epoxy paint.
Pole should be flame retardant as per IS
6746. Resin used shall be UV resistance
and pigmented. A highly weather
resistant polyurethane coating shall be
applied to the pole after applying
suitable primer system that ensures
proper adhesion of the paint. Minimum
coating thickness shall be 80 to
micron. Deflection of the pole shall not
exceed more than 10% of the length of
pole for the given load“? Pole should be
generally made as per the dimensional
data, performance criteria and some
interchangeability features of poles as
standard ANSI C 136.20 latest version or
ASTM D 4923/01 . The size of pole and
type of installation are as below
Supply of approved make FRP Pole
having following specifications: FRP
Light Pole made by CNC filament winding
machine using thermoset resin
polyester/epoxy resin system) having
minimum 62% glass content. The pole
55 should be in one piece and tapered round
in shape, having smooth finish and
should be totally free from corrosion as
well as non conductive& shock proof
Pole should be provided with FRP
Anchor Base and it should be heavy duty,
or MS Material duly painted with Epoxy
Pole should be flame retardant as per IS
6746. Resin used shall be UV resistance
and pigmented. A highly weather
resistant polyurethane coating shall be
applied to the pole after applying
suitable primer system that ensures
proper adhesion of the paint. Minimum
coating thickness shall be 80 to
micron. Deflection of the pole shall not
exceed more than 10% of the length of
56 pole for the given load“ Pole should be
generally made as per the dimensional
data, performance criteria and some
interchangeability features of poles as
per standard ANSI C 136.20 latest
version or ASTM D 4923/01 including
cable termination box with necessary
accessories . The size of pole and type of
installation with foundation as per
manufacturer details and site
requirement are as below .
(1) Suitable for base plate mounting
single arm Bracket.
[H] Overall length of 6 Mtr. Average
Thickness: 7.5mm
Top/ Bottom OD Dia A/F 89mm ± 2mm
approx. approx. Weight of Pole 32 kg
approx. (Without Base) Anchor Base
(Size 300X300 & 18mm Th.)
(2) Suitable for base plate mounting
Double arm Bracket.
[C] Overall length of 6 Mtr. Average
Thickness: 8mm.
Top/ Bottom OD Dia A/F 114/174 mm ±
2mm approx. approx. Weight of Pole
kg approx. (Without Base) Anchor Base
(Size 300X300 & 18mm th.)
Providing 1:2:4 cement concrete
foundation & 70 % PCC from bottom
including excavation for the pole of size
45 x 45 x 100 cm. Deep in below ground
59 level with plinth of 45 cm x 45 cm (or 45 Ea. 30 801.00
cm dia x 45 cm) high upper ground level
with necessary curing and finishing in
approved manner.
( for 4 & 6 mtr pole)
Providing cement concrete.for
foundation or for concrete filling in 1:2:4
60 ratio with 20 to 25 mm stone metal duly Cu.Mtr 10 5,077.00
plastered with necessary curing for pole
muffing or any other purpose.
Providing FRP arm bracket of having
sets of suitable SS304 hardware for fixing
the brackets & spread of 1.2 Mtr(Suitable
for 89 to 114 mm pole top dia)
(A) Single arm bracket Ea 20 2,526.00
(B) Double arm bracket Ea 10 3,895.00
(C) Triple arm bracket Ea 10 5,259.00
Supplying and erecting LED street light /
Flood light fittings with High power
White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free
High pressure die cast aluminum housing
with smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/
lenses, with toughened glass with
company mark/name engraved or
embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K
to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80
certificates)(NOTE: Below description
have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge
may select any wattage capacity between
the ranges shown.). (A) Street Light (IP-
65), Surge protection -4KV integral and
,Light must have 440VAC line supply
with over-voltage protection. (iii) Above
60 to 90 watts cat-III
(B) Flood Light (IP-65), Surge protection
-4KV integral and Light must have
63 440VAC line supply with over voltage Each 21 7,195.00
protection. (iv) above 90 to 120 watts
Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv
grade ISI marked copper wires of
following size to be erected as directed.
(h) 2.50 Sq.mm 3 core round PVC
Supplying & erecting approved make IP
55 grade Company fabricated Timer
Panel of following capacity for switch
On-Off street lights on time scheduling
basis made from 16G CRCA sheet duly
epoxy power painted inside and outside
with hinged doors and locking
arrangement consisting of suitable size of
4 Pole MCB and 4 pole contactor (cat-
III)with analog time switch, auto manual
switch of same make and suitable input
and output Bakelite terminals and with
door earthing approved by Engineer in
Providing and erecting Annealed bare
Copper wire 8 to 16 SWG.
Supplying & erecting in earthpit of
minimum bore dia. 225mm size
approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe
dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm
68 having 200-250 Micron galvanising,
connection terminal dia of 14 mm with
constant ohmic value surrounded by
highly conductive compound with high
charge dissipation suitable for following
type of applications with chamber and
heavy duty cover.(approved make OEM
has to submit test certificate including
value of earth resistane of installation.
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of
[B] For Electrical installation up to 11 KV
located in other than normal soil i.e.
Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of
[C] For Electrical Installation covering
Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant& Sensitive
Computer System(like Automation,
SCADA)i.e. independent Earthing Ea. 2 10,489.00
located in other than normal soil i.e.
Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of
WATER COOLER AND PURIFIER
Providing & erecting water cooler having
storage capacity 150 Ltr. & cooling
capacity 150 Ltr.per hour @ an ambient
temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour,
The water cooler should be comprising of
70 hermetically sealed compressor, fan Ea. 1 55,340.00
motor, condensing unit, water tank
surrounded by evaporating, coil,
thermostats, relay etc.complete with
necessary inlet & outlet connection. The
body of water cooler will be made from
Stainless Steel.
Supplying and erecting water filter cum
purifier with ultra violate technology.
71 (Aquaguard / waterdoc model or Ea. 1 5,371.00
equivalent symphony/ crystal/videocon
TOTAL FOR ELECTRICAL WORKS :
WATER SUPPLY PLUMBING & SANITARY
Providing erecting and fixing double
coated Syntex PVC. (ISI) water tank of
72 required capacity each with all necessary litre 1000.00 3.91
fittings and connection etc. complete on
Providing and fixing wsh down water
closet (European type, W.C. Pan) with
integral P or S trap including jointing the
trap with soil pipe in Cement Mortar 1:1
(1-Cement : 1-fine sand) (Seal and cover
to be measured and paid for
separately)(A) vitreous China Pattern :(i)
in white colour
Providing and fixing 12.5 Litres low level
flushing cistern with a pair, of C.I. or Mild
brackets, complete with fittings such as
lead valve less syphon, 15mm nom.nal
size brass ball valve with polythene float,
C.P brass handle unions and couplings
for connections, with inlet, outlet and
overflow pipes, 40mm dia. porcelain
enamelled flush bend including cutting
holes in walls and making good the same
connecting the flush bend with cistern
and closet (overflow pipe to be measured
and paid for separately)(A) Vitreous
China (I) In white colour
Providing and fixing plastic seat and
cover for wash down water closer with
C.P. brass hinges and rubber buffers. (B)
Black plastic seal and cover.
Providing and fixing washbasin with
single hole for pillar tap with C.I. or M.S.
brackets painted white including sutting
76 holes and making good the same but Each 2.00 1441.64
excluding fittings.(A) Vitreous China:(ii)
Flat Back washbasin 550 mm x v 400mm
size. (i) In white colour.
Providing and fixing C.P. brass waste for
washbasin or sink. (B) 40mm dia.
Providing and fixing M.I. fisher union
for washbasin or sink. (B) 40mm dia.
Providing and fixing 100mm sand cast
79 iron grating for gully, floor or Nahni Each 2.00 36.61
Providing and fixing 600mm x 450mm
bevelled edge mirrror of superior glass
mounted on 6mm thick A.C. sheet or
plywood sheet and fixing to wooden
pluge with C.P. brass screws and
Providing and fixing 600mm x 120mm
glass shelf with C.P. brass bracket and
guard rail complete mixed to wooden
plug with C.P. brass screws.
Providing and fixing toilet paper
holder.(A) C.P. Brass
Providing and fixing screw down bib taps
of following size.(B) Brass chromium
plated screws down Bib Tap. (ii) 20mm
Providing and fixing pillar tap, capstan
head, screw down high pressure with
screws, shanks and back nuts.(ii) 20mm
Providing and fixing chromium plated
brass half trunflush cock of approved
quality including fixing in pipe line etc.
complete.(i) 20mm dia.
Providing and fixing Urinal or approved
quality including conecting the Urinal
86 with waste pipe , tap etc. complete.(A) Each 3.00 1051.66
White earthenware flat back or corner
type size 430mm x 260mm x 350mm.
Providing and fixing Rubber plug for
sink or wash basin.
Providing and fixing chromium plated,
88 bottle trap with necessary couplings of Each 2.00 292.87
approved quality for wash basin.
Providing and fixing ball cock of
89 approved. quality as directed.(A) Copper Each 5.00 187.96
Metal (ii) 50mm dia.
Providing and fixing Angle Cock with
screw, back nuts all necessary fittings etc.
90 Completed Each 3.00 496.00
(Cera-CM108/ Parryware-T9939A1 /
Hindware-F100043)
Providing and fixing 12mm dia. Health
faucet with 8 mm dia of JAQUAR /
HINDWARE/ CERA or approved make
91 selected by Architect with flexible pipe Each 5.00 1256.00
of 1mt. length and holding stands
complete. Model Equivalant to Jaquar-
Providing and fixing concealed center
point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water
of following dia. nominal bore tube
fittings and clamps including making
good the wall, ceiling and floor etc.
complete. [B] 20 mm.
Providing and fixing concealed center
point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water
of following dia. nominal bore tube
fittings and clamps including making
good the wall, ceiling and floor etc.
complete. [D] 32mm.
Providing and fixing concealed center
point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water
of following dia. nominal bore tube
fittings and clamps including making
good the wall, ceiling and floor etc.
complete. [E] 40mm.
Providing and fixing Gun metal check or
95 non-return fullway wheel valve.(C) Each 1.00 346.00
Providing and fixing to wall ceiling and
floor 10.0 Kg. F/Cm2 working pressure
polythene pipes of the following outside
96 Dia. Low densidy, complete with special Rmt 24.00 277.46
falnge compression type fittings, wall
clipsetc. including making good the wall
ceiling and floor.(F) 75mm
Providing and fixing to wall ceiling and
floor 10.0 Kg. F/Cm2 working pressure
poluthene pipes of the following outside
97 Dia. Low densidy, complete with special Rmt 30.00 335.69
falnge compression type fittings, wall
clipsetc. including making good the wall
ceiling and floor.(G)110 mm
DRAINAGE & SEWERAGE ITEM
Constructing Manhole with R.C.C. top
slab in 1:2:4 mix (1-cement :2-coarse
sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6
(1-cement : 3- coarse sand :6-Brick bats
40 + 50mm size) inside plastering 15mm
thick with Cement Mortar 1:3 (1-Cement
: 3-coarse sand) finished with a floating
coat of neat cement and making channels
in cement concrete 1:2:4 mix (1-Cement
:2-Coarse sand :4-stone aggregate 20mm
98 nominal size) finished smooth complete Each 1.00 10933.41
including curing and festing (i) Inside
size 900mm x 1200mm and 1.5M. deep
including C.I. cover with frame size
560mm diameter total weight of cover
and frame to be not less than 128 kgs.
(Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick
msonry using brick having crushing
strength not less than 35Kg. /Sq.cm. in
Cement Mortar 1:5 (1- Cement: 5-Coarse
sand)(1) A type depth 0.90 Metre for
150mm diameter sewer.
FINAL TOTAL OF THIS
Signature of contractor Additional City Engineer (NORTH ZONE)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
MAHANAGAR SEVA SADAN - NORTH ZONE
Name of Work: CONSTRUCTION Of SKATING RINK & BOX -CRICKET AT NARODA-2 T.P.S NO-40,F.P NO-35
FINANCIAL BID ( To Be Submitted Online Only )
Sr. No. Description Amount
1 Amount For Civil+Plumbing+ElectriC Rs.2,12,19,760/90
Total Rs.2,12,19,760/90
I/We am/are willing to carry out work at ______ % above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : RS. Estimated cost put to tender : RS.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Signature of contractor Additional City Engineer (NORTH ZONE )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
05 GENERAL ELECTRICAL-TECHNICAL SPECIFICATION Skating rink&box-cricket.pdf
05 GENERAL PLUMBING TECHNICAL SPECIFICATION Skating rink box cricket.pdf
NOTICE INVITING ONLINE TENDER.pdf
VOL 1 GENERAL CONDITION PART A Skating rink&box-cricket.pdf
VOL 1 TECHNICAL SPECIFICATION PART B Skating rink&box-cricket.pdf
VOL 2 PRICE BID.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .