Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹7.5 L Quoted ₹7.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹8.8 L+₹1.1 L (14.8%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.8 L+₹1.1 L (14.8%) | L2 | Rejected-Finance NOT A LOWEST BIDDER |
| 3 | L3₹9.0 L+₹1.3 L (17.6%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹9.0 L+₹1.3 L (17.6%) | L3 | Rejected-Finance NOT A LOWEST BIDDER |
| 4 | L4₹9.7 L+₹2.0 L (26.5%)Rejected-Finance | ₹9.7 L+₹2.0 L (26.5%) | L4 | Rejected-Finance NOT A LOWEST BIDDER |
| 5 | L5₹11.7 L+₹4.1 L (53.8%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | ₹11.7 L+₹4.1 L (53.8%) | L5 | Rejected-Finance NOT A LOWEST BIDDER |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
6 Feb 2024, 6:00 pmClosed
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
REPAIR MAINT OF UNSERVICEABLE INTERNAL WIRING LIGHT FITTINGS INCL OTHER E M ALLIED WORKS AGAINST PGME OF JOSHIMATH AULI MANA UNDER GE 871 EWS
2024_MES_636479_1
8789/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath Auli Mana
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹24,000
Yes
2 Apr 2024
9 Jan 2024
13 Feb 2024
9 Jan 2024
6 Feb 2024
23 Jan 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking into credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed
M&L for point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
M&L for point wiring in PVC conduit all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 6 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4.0 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed.
M&L socket out let 5 pin 5/6 Amps all as specified and directed.
S&Fsocket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F bell push, flush type 5 Amps white or ivory, all as specified and directed.
S&F calll bell Ding Dong 230V, AC, single phase all as specified and directed.
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230 volts, indoor recess mounting including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Taking down and refixing of LED tube light fitting bright 18 Watt slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
M&L in replacement earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed.
Supply and fix in replacement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed.
All as per item No 27 hereinbefore but MCB DP 63 amps.
All as per item No 27 hereinbefore but MCB TPN 63 amps.
All as per item No 27 hereinbefore but MCB TPN 100 amps.
Supply & fix in replacement of on load change over switch 4 pole, 100 Amps suitable for 3 phase, 415 Volts in sheet metal enclosures complete all as specified & directed.
Supply & fix in replacement of on load change over switch 4 pole, 63 Amps suitable for 3 phase, 415 volts in sheet metal enclosures complete all as specified & directed.
Supply & fix in replacement of on load change over switch 2 pole, 32 Amps suitable for single phase , 230 volts in sheet metal enclosures fixed on wall complete all as specified & directed.
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed. Note :- Defective parts like inner tank, heating element, gyser assembly, auto thermal cut, rubber gasket, bottom plate, indication lamp etc shall be measured and paid separately
S&F in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed set of 02 Nos with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F in replacement of PVC flexible pipes 15 mm dia (heavy duty) both end socketed with washer 600 mm long set of 02 Nos for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
S&F in replacement of inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made SS duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made SS duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made SS duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made SS duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made SS duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of indication lamp (Green/Red) as per required at site all as specified & directed.
S&F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
S&F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F in replacement of bottom plate as per existing size (ISI Marked) all as specified and directed
S&F in replacement of Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F in replacement of Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately
S&F in replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed Make : SKF/TATA/Universal/polar
S&F in replacement of condenser capacity 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
S&F in replacement of blade suitable for exhaust fan 300 mm, size as that of existing defective one all as specified and directed. (ISI Marked)
S&F in replacement of blade suitable for exhaust fan 450 mm, size as that of existing defective one all as specified and directed. (ISI Marked)
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x4sqmm PVC insulated multistrand copper conductor FRLS with 01x4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:- Two runs of 4sqmm conductors and one run of 4 sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x6 sqmm PVC insulated multistrand copper conductor FRLS as earth continuity wire all as specified and directed. Note:- Two runs of 6 sqmm conductors and one run of 6sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC conduit of required size 2 x 4 sqmm PVC insulated multistrand copper conductor FRLS with 01x4 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Note:-Two runs of 4sqmm conductors and one run of 4 sqmm conductor with conduit will be measured as one length.
Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor solid conductor ,served with inner sheathing of PVC tape and overall PVC tape and overall PVC Sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , 10 sqmm , twin core cable flat or circular complete all as specified and directed.
Taking down and dismantling of refrigerator/deep freezer of capacity 160-320 litres of capacity after disconnecting of electric connection for servicing, overhauling washing Cleaning with new gasket of door, unserviceable tray change with new tray as per site refrigerator and and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts all as specified and directed. Note:- Defective parts like capacitor, compressor, condensing coil, fan motor, blower motor, fan blade and gas charging will be measured and paid separately under relevant item of schedule.
Supply and fix in replacement of compressor suitable for 160-320 litres capacity refrigerator. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Supply and fix in replacement of capacitor (starting/running) suitable for 160-320 litres capacity refrigerator (ISI Marked) all as specified and directed. Make : Voltas/Zeco/Blue Star
Supply and fix in replacement of condensing coil assembly suitable for 160-320 litres capacity refrigerator all as specified and directed. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
M&L GAS charging (R-24/134A) suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply and fix in replacement of PVC/Iron fan blade suitable for 160-320 litres capacity of refrigerator. (ISI Marked) all as specified and directed.
Supply and fix in replacement of fan motor/ blower motor suitable for 160-320 litres capacity of refrigerator all as specified and directed. Make : BLUE STAR/ WHIRPOOL/ VOLTAS/ SAMSUNG
Supply and fix in replacement of LED slim square/circular panel light fitting for surface ceiling light, 10 watt, colour white/warm white and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaries suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaries with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S & F in replacement of SSC 15 Amp including PVC gang box fixing screw ISI marked. Make : Anchor/Legrand/HPL/Cona.
S&F in replacement of SSC 5 Amp including PVC gang box and fixing screw ISI marked. Make : Anchor/Legrand/HPL/Cona.
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed. Make : Havells/Polycab/Finolex.
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed.
Supply and fix PVC insulated multistrand copper conductor 2.5 sqmm wire ,3 Core all as specified and directed.
Supply and fix in replacement LED light fitting 10 watt, slim design, 230volts, indoor recess mounting down lighter circular type with reflector and detachable ballast tray, with lamp holder, connector block all as specified and directed.
Supply and fix in replacement LED light fitting four feet 1x18 watt, slim design, 230volts, indoor recess mounting with reflector and connector block and all as specified and directed.
Supply and fixing in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
Supply and fixing in replacement switch piano flush type 15/16 Amps single pole one way all as specified & directed.
Supply and fixing in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
Supply and fixing in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
Supply and fixing in replacement call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
Supply and fixing in replacement plug top 15 Amp white or ivory, ISI marked all as specified and directed.
Supply and fix in replacement 5 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed.
Supply and fix in replacement 7 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed.
Supply and fix in replacement 9 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed.
Supply and fix in replacement PVC conduit 20 mm dia suitable for 230/240V AC supply all as specified and as directed.
Bedi Refrigeration Works
JAGAT POWER ELCTRICAL
Amit Engineering
AUTOMATION AND SWITCHGEAR PANELS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .