Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,740Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.0 L+₹3,140 (3.15%)Rejected-Finance CB 4190 SREE CHITHRA NAGAR PANGODE THIRUMALA P O THIRUVANANTHAPURAM 695 006 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695006 | L2 | Rejected-Finance L2 |
Tender Value
₹1.0 L
EMD Value
₹2,600
Closing Date
10 Feb 2025, 5:00 pmClosed
Assistant Executive Engineer
Office of the Assistant Executive Engineer, Engineering Unit, Subdivision1, Kariavattom Campus .
item rate
2025_KU_730090_1
AEE I/DB1/ (e-GP)/31/2024-2025
Open Tender
Electrical Works
Item Rate
15 days
Palayam
Please refer Tender documents.
6 documents required · 6 mandatory
₹525
₹2,600
27 Feb 2025
25 Jan 2025
13 Feb 2025
25 Jan 2025
10 Feb 2025
25 Jan 2025
25 Jan 2025 - 10 Feb 2025
Amount
AIR CONDITIONING
od216398/2024_2025 : 1.0 -Ton 5-star split type inverter AC unit LATEST BEE 5 STAR<br>Supply, installation, testing and commissioning the following capacity of wall mounting, high energy efficient, single phase, inverter type, split air conditioner unit (IDU) having 5-star rating as per BEE 1.0 Ton (1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) Rated cooling capacity (in Watts) as per IS:1391 (Part 2) - 1750W ≤ 3500W, fitted with hermetically sealed rotary compressor (ODU) suitable for eco-friendly and energy efficient refrigerants R-32A / R-410A, conforming to IS: 1391 Part-2 1992 (with latest amendments except power consumption norms) suitable for operation on 230 V, 50 Hz AC supply and capable of performing functions such as cooling, dehumidifying, air circulating, filtering etc and having features of long distance piping flexibility, wide angle air flow, IDU noise level < 43 dB (A) and ODU noise level < 56 dB (A) as required. The condensing and evaporating coils should be made of copper tubes (100% copper) and a standard length of upto 3 metres of soft drawn bright annealed copper refrigerant pipes of suitable sizes should be supplied along with the AC unit for the function of suction and discharge and the copper pipes should be properly insulated with 10 mm thick closed cell Class O elastomeric nitrile rubberised foam sleeve insulation. A standard length of upto 3 metres of suitable size ISI marked flexible copper control cable for electrically connecting IDU and ODU of AC unit and microprocessor based wireless remote controller with required number of suitable batteries should also be supplied along with the AC unit as required. There should be 3 numbers of comprehensive free service for the AC unit (IDU & ODU) for one year, applicable from the date of commissioning. One year replacement warranty should be provided for the entire AC unit along with two years exclusive warranty for PCB , and ten years exclusive warranty for the compressor. ( AC Make- Panasonic, Voltas, Carrier, Mitsubishi, Blue Star or Daikin)
od216399/2024_2025 : Supply and Installation of powder coated/stove enamelled metallic mount for wall mounting of out door unit of air conditioner with required number of anchor bolts, vibration isolators and non slip foundation bolts of suitable size of ODU
od216400/2024_2025 : Supply, installation, testing and commissioning of wall mounting type 4 kVA<br>voltage stabilizer with input voltage range of 170 V - 270 V and having features of<br>high power efficiency, intelligent time delay system, Low & High voltage cut-off<br>protection, built-in thermal overload protection, LED indications etc suitable for<br>single phase 1-Ton / 1.5-Ton air conditioner unit with three years warranty and<br>three months replacement guarantee. (Make: V-Guard/ Philips/ Voltas/ Crompton Greaves/Godrej/ Microtek)
od216401/2024_2025 : Supply and installation Soft drawn bright annealed copper pipes of 0.8mm thickness(suction and discharge) covered with sleeve type insulation of OEM approved make insulation of minimum 10 mm thick completely wrapped with monsoon tape shall be fixed on walls with Aluminium straps with necessary brazing, pressure testing suitable for 1.0TR machines
1.17.13 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
90.10.3.23 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 16A 3 pin plug top
R.Radhakrishnan Nair (BID ID -2100006)
Bidder Name
R.Radhakrishnan Nair
ASOK ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1164227.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .