| Sl No | Description | Qty | Unit | JAI RAM SHARMA L2 | MANOJ KUMAR L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in foundations, trenches etc., in earth work, lift upto 1.50 mts. Stacking the excavated soil not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cms. Layers, when required into plinths sides of foundation etc., consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as directed within all leads & lifts as per entire satisfaction of Engineer in charge. | 12.9 | Cum. | 210 ₹2,709 | 200 ₹2,580 Lowest |
| 2.00 | Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per the direction of Engineer-in-Charge. | 3.45 | Cum. | 2,450 ₹8,452.5 Lowest | 3,050 ₹10,522.5 |
| 3.00 | Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including raking out joints in cement mortar 1 : 6 ( 1 cement : 6 sand) within all leads and lifts as per the direction of Engineer -in- Charge. | 7.16 | Cum. | 5,740 ₹41,098.4 | 4,000 ₹28,640 Lowest |
| 4.00 | Brick work using common burnt clay building bricks of approved quality in super structure in cement mortar 1: 6 (1 cement : 6 sand) above plinth level up to floor two level (2nd class bricks) within all leads and lifts as per the direction of Engineer-in -Charge. | 9.72 | Cum. | 6,240 ₹60,652.8 | 6,000 ₹58,320 Lowest |
| 5.00 | Providing wood work in frames of doors, windows, clerestory, windows and other frames wrought, framed and fixed in position 2nd. Class deodar wood within all leads and lifts as per the direction of Engineer-in -Charge. | 0.15 | Cum. | 82,000 ₹12,054 Lowest | 85,000 ₹12,495 |
| 6.00 | Providing and fixing paneled and glazed or paneled and glazed shutters for doors, windows and clerestory windows including bright finished / black enamelled iron butt hinges with necessary screws in 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. | 4.24 | Sqm. | 3,200 ₹13,568 Lowest | 3,600 ₹15,264 |
| 7.00 | Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for doors windows and clerestory windows including bright finished black enamelled iron hinges with necessary screws 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. | 4.24 | Sqm. | 2,800 ₹11,872 | 2,500 ₹10,600 Lowest |
| 8.00Providing form work with steel plates 3.15 millimetre thick welding with angle iron in frame 30x30x5 milimetre, so as to give fair finish including centering, shuttering strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 metres and removal of the same for in-situ-reinforced concrete and plain concrete work in:- | |||||
| 8.01 | Foundations,footings,bases of columns etc. and mass concrete within all leads and lifts as per the direction of Engineer-in- Charge. | 2.39 | Sqm. | 190 ₹454.1 Lowest | 250 ₹597.5 |
| 8.02 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc. up to 200 milimetres in thickness within all leads and lifts as per the direction of Engineer -in- Charge. | 21.89 | Sqm. | 275 ₹6,019.75 Lowest | 350 ₹7,661.5 |
Tender Value
₹2.8 L
EMD Value
₹5,515
Closing Date
20 Jun 2026, 11:00 amClosed
Er.Anand Blouria
Jal Shakti Division Nurpur
C/O Pump House at LIS Thora Bhaloon)
2026_HPIPH_136435_1
EENPREA_1-1045-65 dated 11-06-2026
Open Tender
Civil Works
Item Rate
90 days
Jassur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹5,515
16 Jul 2026
12 Jun 2026
20 Jun 2026
12 Jun 2026
20 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in foundations, trenches etc., in earth work, lift upto 1.50 mts. Stacking the excavated soil not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cms. Layers, when required into plinths sides of foundation etc., consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as directed within all leads & lifts as per entire satisfaction of Engineer in charge. | 12.9 | Cum. | - | - |
| 2 | Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand: 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per the direction of Engineer-in-Charge. | 3.45 | Cum. | - | - |
| 3 | Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including raking out joints in cement mortar 1 : 6 ( 1 cement : 6 sand) within all leads and lifts as per the direction of Engineer -in- Charge. | 7.16 | Cum. | - | - |
| 4 | Brick work using common burnt clay building bricks of approved quality in super structure in cement mortar 1: 6 (1 cement : 6 sand) above plinth level up to floor two level (2nd class bricks) within all leads and lifts as per the direction of Engineer-in -Charge. | 9.72 | Cum. | - | - |
| 5Providing wood work in frames of doors, windows, clerestory, windows and other frames wrought, framed and fixed in position 2nd. Class deodar wood within all leads and lifts as per the direction of Engineer-in -Charge. | |||||
| 6 | Providing and fixing paneled and glazed or paneled and glazed shutters for doors, windows and clerestory windows including bright finished / black enamelled iron butt hinges with necessary screws in 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. | 4.24 | Sqm. | - | - |
| 7 | Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for doors windows and clerestory windows including bright finished black enamelled iron hinges with necessary screws 2nd. class deodar wood 40mm thick within all leads and lifts as per the direction of Engineer-in -Charge. | 4.24 | Sqm. | - | - |
| 8Providing form work with steel plates 3.15 millimetre thick welding with angle iron in frame 30x30x5 milimetre, so as to give fair finish including centering, shuttering strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 metres and removal of the same for in-situ-reinforced concrete and plain concrete work in:- | |||||
| 8.01 | Foundations,footings,bases of columns etc. and mass concrete within all leads and lifts as per the direction of Engineer-in- Charge. | 2.39 | Sqm. | - | - |
| 8.02 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc. up to 200 milimetres in thickness within all leads and lifts as per the direction of Engineer -in- Charge. | 21.89 | Sqm. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
form06.pdf
Tender Documents • 0.61 MB
termsandconditions.pdf
Tender Documents • 0.19 MB
BOQ_201939.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .