Tender Value
₹14.2 L
EMD Value
₹28,340
Closing Date
2 Aug 2023, 2:00 pmClosed
EXECUTIVE ENGINEER, ED-RAJOURI, JPDCL
Office of Executive Engineer, JPDCL, Electric Division, Rajouri
SITC ON TURNKEY BASIS FOR W NO. 2, W NO. 6 THANDA PANI AND STRINGING OF LT CONDUCTOR IN THNADAPANI
2023_PDD_221278_1
EDR/32 of 2023-24 Dated 12.07.2023
Open Tender
Electrical Works
Turn-key
60 days
SUNDERBANI
AS PER SECTION-III OF SBD
5 documents required · 5 mandatory
₹1,000
EXECUTIVE ENGINEER, ED-RAJOURI, JPDCL
₹28,340
14 Aug 2023
13 Jul 2023
4 Aug 2023
13 Jul 2023
2 Aug 2023
21 Jul 2023
Amount
QUOTED TOTAL OF RESPECTIVE BOQ TO BE ENTERED
SCHEDULE-A (BOQ2)
SCHEDULE-B (BOQ3)
SCHEDULE-C (BOQ4)
Description of Work / Item(s)
Amount
11 kV HT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 9 mtrs long (410-SP33)
30 mm2 ACSR wsl Conductor
Galvanisied Channel V cross-arm with Top brackets and Clamps
Galvanisied Channel cross-arm/ Angle/ Flat including clamps and braces.
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete.
Galvansied Nuts and Bolts of sorts
11/0.44 kV S/Stn Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
63 KVA Transformer Level II , 11/0.433KV,3-Phase Distribution Transformer with Bimetallic Terminal Connectors ,Aluminium Wound and with LV Cable Box having detachable Aluminium Gland plate.
LT Distribution box for 63 KVA with MCCB for incomer and SFU's for outgoing Circuits.
S.T Pole 9 mtrs long (410-SP33)
Surge Arrester Station Type 9KV, 10 kA (Polymer Type)
11 KV Horn Gap Set, 3 Phase, 200 Amp
11 KV GO, AB Switch 3-Phase ,3-pole, 200 Amp, Vertical Type
Channel/Flate/Angle in shape of fabricated X-arms, Top bracket, Angle braces, clamps etc.
GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete.
PVC insulated stranded conductor FRLS type 1.1kv Grade Cable 185 mm sq with Thimbles
Wedge Connectors
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
Nuts and Bolts of sorts
Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. (Specification as per cost data)
LT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 8 mtrs long (410-SP15)
30 mm2 ACSR wsl Conductor
Shakle Insulator (16KN)
Mukky Clamps
Nuts and Bolts of sorts
Description of Work / Item(s)
Amount
11 kV HT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 9 mtrs long (410-SP33)
30 mm2 ACSR wsl Conductor
Galvanisied Channel V cross-arm with Top brackets and Clamps
Galvanisied Channel cross-arm/ Angle/ Flat including clamps and braces.
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
Galvansied Nuts and Bolts of sorts
11/0.44 kV S/Stn Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
63 KVA Transformer Level II , 11/0.433KV,3-Phase Distribution Transformer with Bimetallic Terminal Connectors ,Aluminium Wound and with LV Cable Box having detachable Aluminium Gland plate.
LT Distribution box for 63 KVA with MCCB for incomer and SFU's for outgoing Circuits.
S.T Pole 9 mtrs long (410-SP33)
Surge Arrester Station Type 9KV, 10 kA (Polymer Type)
11 KV Horn Gap Set, 3 Phase, 200 Amp
11 KV GO, AB Switch 3-Phase ,3-pole, 200 Amp, Vertical Type
Channel/Flate/Angle in shape of fabricated X-arms, Top bracket, Angle braces, clamps etc.
GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete.
PVC insulated stranded conductor FRLS type 1.1kv Grade Cable 185 mm sq with Thimbles
Wedge Connectors
11 kv Pin insulators with pins (10KN)
11 kv Disc insulators with fittings (45 KN)
Nuts and Bolts of sorts
Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. (Specification as per cost data)
LT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
S.T Pole 8 mtrs long (410-SP15)
30 mm2 ACSR wsl Conductor
Shakle Insulator (16KN)
Mukky Clamps
Nuts and Bolts of sorts
Description of Work / Item(s)
Amount
LT Line Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and then complete Erection, Testing and Commissioning as per REC/PDD Standard of
30 mm2 ACSR Wsl Conductor
Shakle Insulator (16KN)
Mukky Clamps
Nuts and Bolts of sorts
TESLA ENGINEERING WORKS
Fazal Hussain
TESLA ENGINEERING WORKS
Fazal Hussain
TESLA ENGINEERING WORKS
Fazal Hussain
Fazal Hussain
M/S SWASTIK ENGINEERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .