| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 CrAccepted-AOC | ₹24.6 Cr Quoted ₹24.7 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹24.9 CrRejected-Finance | ₹24.9 Cr | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹27.2 CrRejected-Finance 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹27.2 Cr | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹29.8 CrRejected-Finance | ₹29.8 Cr | L4 | Rejected-Finance Being other than lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not having requisite work experience and turnover |
Tender Value
₹20 Cr
EMD Value
₹13.3 L
Closing Date
19 Feb 2022, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243 001 Tel 05812426819
PROVISION OF OTM FOR AN INF BN AT GHINGHARIKHAL RANIKHET
2021_MES_467032_3
CEBZ / PGH / T-05 OF 2021-22
Open Tender
Civil Works
760 days
RANIKHET
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE RANIKHET
₹13.3 L
Yes
24 Feb 2023
17 Jan 2022
21 Feb 2022
17 Jan 2022
19 Feb 2022
1 Feb 2022
18 Jan 2022 - 25 Jan 2022
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Schedule 'A' Part-I )
Total amount of SCHEDULE 'A' PART-II A (INTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-II A)
SCHEDULE 'A' PART-II B (INTERNAL WATER SUPPLY)
S & F for Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified. Make:- Jaquar /Cera /Parryware
S & F for brass chromium plated, Angle valve, fancy type, 15 mm dia complete all as specified and directed. Make:- Jaquar /Cera /Parryware
S & F for brass chromium plated shower rose with 150mm long CP shower arm 125 mm size revolving type suitable for 15 mm bore pipes having maximum flow rate of water 6 / LPM @ 45 PSI or 3.1 bar pressure complete all as specified and directed. Make:- Jaquar / Cera / Parryware
S & F for brass chromium plated shower rose with 150mm long CP shower arm 125 mm size revolving type suitable for 15 mm bore pipes complete all as specified and directed. Make:- Jaquar / Cera / Parryware
S & F Bib tab, cast copper alloy, Fancy type, chromium plated with cruth or butterfly handle screw down ,screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket having maximum flow rate of water 6 / LPM @ 45 PSI or 3.1 bar pressure complete all as specified and directed. Make:- Jaquar /Cera / Parryware
S & F Bib tab, cast copper alloy, Fancy type, chromium plated with cruth or butterfly handle screw down ,screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make:- Jaquar /Cera / Parryware
S & F for 15mm bore pillar tap, cast copper alloy, with capstain head, chromium plated,screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, fancy type, screwed for iron pipe having maximum flow rate of water 6 / LPM @ 45 PSI or 3.1 bar pressure complete all as specified and directed. Make:- Jaquar /Cera /Parryware
S & F for 15mm bore pillar tap, cast copper alloy, with capstain head, chromium plated,screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, fancy type, screwed for iron pipe complete all as specified and directed. Make:- Jaquar /Cera /Parryware
S & F Vitreous Chinaware wash down water closet pan (pedestal pattern) white, premium quality with soft closing seat & cover including fixing bolts jointing to flushing cistern and flush pipe anti syphonage pipe etc complete all as specified and directed.
S & F Vitreous Chinaware wash down water closet pan (pedestal pattern) white, premium quality with soft closing seat & cover including fixing bolts jointing to flushing cistern and flush pipe anti syphonage pipe etc having maximum flow rate of water 4 litre per flush @ 45 PSI or 3.1 bar pressure complete all as specified and directed.
S & F 10 litres PVC valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket having maximum flow rate of water 4 litre / flush @ 45 PSI or 3.1 bar pressure complete all as specified and directed.
S & F 10 litres PVC valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket complete all as specified and directed.
S & F vitreous china urinal full stall white having maximum flow rate of water 1.5 litre / flush @ 45 PSI or 3.1 bar pressure complete including providing and fixing plugs and bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws and union, flush pipe, complete including PVC waste pipe all as specified and directed.
S & F vitreous china urinal full stall white complete including providing and fixing plugs and bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws and union, flush pipe, complete including PVC waste pipe all as specified and directed.
Total amount of SCHEDULE 'A' PART-III-A (INTERNAL ELECTRIFICATION) (For details see Schedule 'A' Part-III-A)
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes with earth dolly duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent.
Material and labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes( with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- Note: Switch and socket to be measured and paid for separately.
(a) One light point controlled by one 5/6 amps one way switch
(b) One exhaust fan point controlled by one 5/6 amps one way switch
(c) One Socket outlet, 3/5 pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
(d) One light point controlled by one 5/6 amps two way switch
NOTE FOR ITEM NO. 16.00 TO 20.00 : - Switch, Socket outlet etc. shall be measured and paid separately.
Supply and fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16 Amp, 240 Volts complete all as specified and directed.
Supply and fixing LED 4ft 36 watt with built-inoccupancy sensor surface and wall/surface mounted LED batten with including tube , CRCA housing and polycorbonate diffuser & integrated driver with IEC61000-3-2 ed.3.2 ,2009 for Harmonics,IEC61347-2-13,2006 in Conjuction with IEC51347-1 ed.2.0 ,2007 for electrical safety, with lamp etc. complete with all light accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed & complying with following specifications. System wattage ≤36W, System lumen output ≥ 4000, System efficacy lumen/watt ≥120, Ingress protection - IP20, surge protection minimun 4KV, THD < 10%, CRI>80, CCT= 6500K, Power factor>0.95, Color consistency SDCM< 5, Operating voltage range=140-270V, Electrical insulation should be class 1 & driver should be class B serviceability, PIR sensor should be able to dim light 30-50% in case of no movement, Make:Philips cat part BN308C LED40S-6500 L120 PIR WH/Havells Cat part:LHEDAAP7NW1W036/Trilux Cat Part :(TRL-X F OTA 4000 -857 ET Sens)
Supply and fixing LED indoor surface downlighter fitting 12/15W, Round , Luminaire should have polycarbonate cover with diffused optics complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed. System wattage ≤15W, System lumen output ≥ 1200, System efficacy lumen/watt ≥100, Ingress protection - IP20, THD < 10%, CRI>80, CCT= 5700-6500K, Power factor>0.90, Operating voltage range=140-270V. Make:Philips cat part SM250C LED12S-6500 PSU WH/Havells Cat part:INTEGRANEOSURFACEDLS15WLED840S/Wipro Cat Part :LD06-171-XXX-57-HEWSM)
Supply and fixing LED Porch light fitting 1x7/10 W, Round/Square surface mounted LED flat panel, PDC aluminium housing and PMMA diffuser including lamp complete with all accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed. System wattage ≤10W, System lumen output ≥ 750, System efficacy lumen/watt ≥110, Ingress protection - IP20, THD < 10%, CRI>80, CCT= 5700-6500K, Power factor>0.90, Operating voltage range=140-270V, Make:Philips cat part SM250C LED7S-6500 PSU WH/Havells Cat part:INTEGRANEOSURFACEDLS10WLED840S/Wipro Cat Part :LD06-151-XXX-57-HEWSM)
Supply and fixing blanking plate complete all as specified and directed.
Supply, fixing, connecting and testing building Security light fitting LED 45/50W with pressure die cast aluminium housing, heat resistant toughned glass, IP 66 protection and impact resistance of IK07 with 04KV Built-in Surge Protection Device, better optics for uniform distribution complete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed. System wattage ≤50W, System lumen output ≥ 750, System efficacy lumen/watt ≥115, THD < 10%, CRI>70, CCT= 5700-6500 K, Power factor>0.90, Operating voltage range=120-270V, Make:Philips cat part -BRP056LED59CW SLF PSU S1/Havells Cat part:ENDURAPEARLNEOSL48WLED757PASYTOPC/Wipro Cat part;LR02-501-XXX-57-G1
Material and labour for fabrication & fixing of building security light fitting with GI pipe 'light' grade wall mounting bracket of size 40 mm dia. and 1.50 mtr long fixed to wall with suitable size of nuts, bolts and GI clamps of size 50 x 5 mm as required compleie all as specccified and directed.
Supply, fixing , connecting and testing exhaust fan complete without regulator 230 volts single phase 300 mm sweep not more than 50W, air delivery not less than 1000 CMH, metallic body energy saving fan including louvers, shutters, brackets etc. complete accessories including providing / cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall and connecting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed.
Supply, fixing , connecting and testing exhaust fan complete without regulator 230 volts single phase 450 mm sweep, not more than 130W, air delivery not less than 4000 CMH, metallic body energy saving fan including louvers, shutters, brackets etc. complete accessories including providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall and connecting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed.
Material and labour for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of nominal cross section area as under and drawing into and including PVC non metallic rigid conduit, accessories,of medium grade not less than 25mm dia ,including PVC insulated stranded copper conductor nominal cross section area as under of continuous earth wire complete all as specified. Note: Two runs of current carring conductor cableand one runs of earth conductor cable with PVC conduit mesured as one unit. Note :- PVC Conduit shall be measured and paid seperately under Sch 'A' Part III A.
Two runs of 2.5Sq mm as current carrying conductor and one run of 2.5 Sq mm as earth conductor
Two runs of 4 Sq mm as current carrying conductor and one run of 4.0 Sq mm as earth conductor
Two runs of 6 Sq mm as current carrying conductor and one run of 6.0 Sq mm as earth conductor
Two runs of 10 Sq mm as current carrying conductor and one run of 10.0 Sq mm as earth conductor
Two runs of 16 Sq mm as current carrying conductor and one run of 16.0 Sq mm as earth conductor
Supply and fixing vertical loadline type TPN DB 4 way, as per IS-8623, IP 43 protection, universal mounting with suitable capacity copper busbar with neutral busbar, earth bar and cable ties for cable management, top and bottom removeable gland plate suitable for mounting MCCB TPN 100/125 Amp as incomer and MCB TP/TPN 63 Amp outgoing cables with copper lugs complete with crimping tool complete all as specified and directed.
Material and labour for distribution board double door, for mounting MCBs isolator, ELCBs etc factory made, confirming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be single door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 42 protection class for the followings: (Make: Havells/Legrand/Crompton)
DB SPN 2 Way (without busbar single door) Note:- This item includes 4 Nos quantity for Sch 'A' Part IX "Rain Water Harvesting and Pumping Set".
DB SPN 4 Way
DB SPN 6 Way
DB SPN 8 Way
Supply and fixed MCB SPN 10 KA rating confirming to IS complete all as specified for following ratings.
MCB SPN , 240 volt, 10 Amp
MCB SPN , 240 volt, 32 Amp
MCB SPN , 240 volt, 40 Amp
MCB SPN 240 volt, 63 Amp
Supply and fixed MCB TPN, complete all as specified for MCB FP, 415 Volt, 63Amp, 10KA complete all as speciifed and directed.
Supplied and fixed MCB, 240 Volt single pole, breaking capacity 10KA with complete all as specified for following ratings.
Supplied and fixed MCCB, 4 pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Note: The unit rate includes for protection pipe and GI earth wire 4.00mm dia from top of earth plate up to 7.5 meter above ground level.
Supply and fixed PVC heavy duty cable trancking of size 50 x 50 mm suitable for carring telephone wire / cable TV wire / or any other communication wire / cables complete all as specified and directed.
Supply and fixing modular mounting metal flush box 8 module ISI marked complete all as specified and directed
Supply and fixing LED 4ft 17 watt with built-inoccupancy sensor surface and wall/surface mounted LED batten with including tube , CRCA housing and polycorbonate diffuser & integrated driver with IEC61000-3-2 ed.3.2 ,2009 for Harmonics,IEC61347-2-13,2006 in Conjuction with IEC51347-1 ed.2.0 ,2007 for electrical safety, with lamp etc. complete with all light accessories in and including connecting up with twin core twisted flexible copper conductor cable with suitable size copper wire complete all as specified and directed & complying with following specifications. - (i) System wattage ≤17W (ii) System lumen output ≥ 2000 (iii) System efficacy lumen/watt ≥120 (iv) Ingress protection - IP20 (v) surge protection minimun 4KV (vi) THD < 10% (vii) CRI>80 (viii) CCT= 6500K (ix) Power factor>0.95 (x) Color consistency SDCM< 5 (xi) Operating voltage range=140-270V (xii) Electrical insulation should be class 1 & driver should be class B serviceability (xiii) PIR sensor should be able to dim light 30-50% in case of no movement Make: Philips cat part BN308C LED20S-6500 L120 PIR WH or equivalent in Havells/Wipro/Trilux
Supply and fix of Surface/Recess mounted PIR sensor with advanced passive infrared technology for occupancy detection having 6 mtr detection range at installation height of 2.6 to 3.20 mtr with adjustable delay timing of 1-90 min with 10A allowed load with IP20 protection complete all as specified an directed. Make:Wipro Cat Part :GLPS01S010A or equivalent in Havells/Philips/Trilux
Total amount of SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK) (For details see Schedule 'A' Part-IV in PDF folder)
Total amount of SCHEDULE 'A' PART-V A ( ROAD, PATH AND HARDSTANDING) (For details see Schedule 'A' Part- V A in PDF folder)
SCHEDULE 'A' PART-V B (ROAD PATH AND HARDSTANDING)
M & L for Road Marking Strips, Lines, Dashes, Arrows, Letters etc [Reflective Type] of colour White or Golden Yellow on roads, pavements and the like, with Hot Thermo Plast material by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe heater, driven by skilled operator on road surface including cleaning the road surface of all dirt, scales, oil grease and foreign materials etc complete all as specified and as directed.
M & L for 150mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone agg)as in road path hard standing etc laid in panels with and including necessay formwork as required and finishing the surfaces of concrete, pavement rough by brooming complete all as specified and directed.
M & L for continuous old size brick edging with length equal to the depth of the brick, laid dry on edge vertically of whole fly ash bricks including all necessary earth work, removal of old damaged brick edging complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8 Type D-2 using 40 mm graded broken brick aggregate received from demolition and dismantling from site complete all as specified and directed.
S & F 60 mm thick PCC M-35 machine pressed concrete inerlocking paver block containing 10% construction and demolition waste of any shape and size with grey cement and no pigment confirmng to IS 15658-2006 complete all as specified and directed.
Supply & Fixing cat eye solar reflective of metal body alloy of size 100 mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and including MS stud of suitable size as per manufacturers instructions complete all as specified and directed.
Manufacturing, supplying and fixing retroreflective Mandatory / Regulatory sign boards of 900mm dia with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc as per IRC ; 67 : 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of MS angle iron of size 25 x 25 x 3 mm along with theft resistant measures, mounted and fixed with 2 Nos MS angles of size 35 x 35 x 5mm to a vertical post made up to MS Tee section ISMT 50 x 50 x 6mm welded with base plate of size 100 x 100 x 5mm at the bottom end and including making holes in pipes, angles, flats,providing and fixing MS message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours) backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc complete as per drawing, specification and direction of Engineer-in-charge.
M & L for bituminous premixed carpet 40 mm consolidated thickness with 0.54 Cum of suitable aggregate of grading as specified mixed with 29.20 kg of binder VG -30 added with 6 % plastic waste content by weight of bitumen using dry process as per IRC : SP : 98-2003 laid & rolled with 8 to 10 ton power roller & compacted to required camber and gradient complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VI A (RETAINING WALL) (For details see Schedule 'A' Part-VI A in PDF folder)
SCHEDULE 'A' PART-VI B (RETAINING WALL)
S & F PVC (SWR) pipes 110 mm bore as in weep holes complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VII (AREA DRAINAGE) (For details see Schedule 'A' Part-VII in PDF folder)
Total amount of SCHEDULE 'A' PART-VIII A (SEWAGE DISPOSAL) (For details see Schedule 'A' Part-VIII A in PDF folder)
SCHEDULE 'A' PART-VIII B (SEWAGE DISPOSAL)
M & L for Construction of septic tank 25 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2 in foundation, brick work in CM 1:4, RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
M & L for Construction of septic tank 100 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2 in foundation, brick work in CM 1:4, RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
M & L for Construction of septic tank 150 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2 in foundation, brick work in CM 1:4, RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
Total amount of SCHEDULE 'A' PART-IX A (RAIN WATER HARVESTING AND PUMPING SET) (For details see Schedule 'A' Part-IX A in PDF folder)
SCHEDULE 'A' PART-IX B (RAIN WATER HARVESTING AND PUMPING SET)
BLANK
BLANK
BLANK
Supply, install, testing and commissioning of Monoblock pump-motor 2 HP, Single phase ,220 V ,50 Hz ,2850 RPM ,not less than 30 Mtr head suction dia 65 mm ,disharge dia 50 mm including nut ,bolt wasaher etc all fixing accessories complete all as specified and directed.
Supply and fixing single phase motor spark (9-14A) ,220 Volt DOL starter suitable for 2 H.P centrifugal pump complete all as specified and directed.
Supply and laying GI tubing medium grade of size 65mm bore including all fitting complete all as specified and directed.
Supplying laying and fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area 10 sqmm x 2 core complete all as specified and directed.
Supply and fixed MCB SPN 10 KA rating confirming to IS complete all as specified for ratings MCB SPN , 240 volt, 20 Amp complete all as specified and directed.
M & L for framed bracket of angles cut to shape for making stand cut to shape drilled and counter sunk for screw including bending and welding angles as necessary (angle size 75x75x6mm / 65x65x6mm reveting confirming to FE 410 -W (Gde-250) Quality-B complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-X A (REED BED) (For details see Schedule 'A' Part-X A in PDF folder)
SCHEDULE 'A' PART-X B (REED BED)
M & L for loose filling with sandy loam soil complete all as specified and directed. (Note Quantity 90 Cum pertains to Schedule 'A' Part IX - RAIN WATER HARVESTING AND PUMPING SET )
Total amount of SCHEDULE 'A' PART-XI A (DRIP IRRIGATION ) (For details see Schedule 'A' Part-XI A in PDF folder)
SCHEDULE 'A' PART-XI B (DRIP IRRIGATION)
S & F 8 mm Unplasticised PVC perforated pipes of pressure rating 10 kgf / cm2 laid in trenches complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XII A (VERMI COMPOSITS AND GARBAGE BINS) (For details see Schedule 'A' Part-XII A in PDF folder)
SCHEDULE 'A' PART-XII B (VERMI COMPOSITS AND GARBAGE BINS)
S & F for Stainless Steel outdoor type 3-IN-1 bin with following stickers on the surface (a) Biodegradable waste (Green Colour), (b) Recycled Waste (Blue Colour), (c) Land Fill Waste (Red colour), with stand made with 304 grade steel, and with best in class mirror polished shining pipes and sheet metal. Side rectangular pipes size 25mm x 50 mm, Dustbin size 14" x 24" and 60 Ltr Capacity, Branding board size 37" x 8". Also provided with anty- stray animal spillage lock system and rain shed complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XIII (TREE GUARD) (For details see Schedule 'A' Part-XIII in PDF folder)
Total amount of SCHEDULE 'A' PART-XIV A (SOLAR WATER HEATER) (For details see Schedule 'A' Part-XIV A in PDF folder)
SCHEDULE 'A' PART-XIV B (SOLAR WATER HEATER)
Supply, install, testing and commissioning of Solar water heating system with (Flat Plate Collector) based on direct transferring of heat type BEE 5 Star rating for cold region of 1000 litre capacity, including stainless steel hot water insulated tank and stand for hot water tank & solar water heating system with electrical heating back up of 2x3 KW complete all as specified and directed.
Supply, install, testing and commissioning of Solar water heating system with (Flat Plate Collector) based on direct transferring of heat type BEE 5 Star rating for cold region of 500 litre capacity, including stainless steel hot water insulated tank and stand for hot water tank & solar water heating system with electrical heating back up of 3 KW complete all as specified and directed.
Supply, install, testing and commissioning of Solar water heating system with (Flat Plate Collector) based on direct transferring of heat type BEE 5 Star rating for cold region of 200 litre capacity, including stainless steel hot water insulated tank and stand for hot water tank & solar water heating system with electrical heating back up of 2 KW complete all as specified and directed.
Supply, install, testing and commissioning of Solar water heating system with (Flat Plate Collector) based on direct transferring of heat type BEE 5 Star rating for cold region of 100 litre capacity, including stainless steel hot water insulated tank and stand for hot water tank & solar water heating system with electrical heating back up of 2 KW complete all as specified and directed.
M & L for framed bracket of angles cut to shape for making stand & ladder cut to shape drilled and counter sunk for screw including bending and welding angles as necessary (angle size 75x75x6mm / 35 x 35 x 6 mm reveting confirming to FE 410 -W (Gde-250) Quality-B complete all as specified and directed.
SCHEDULE 'A' PART-XV (SOLAR POWER PLANT)
Supply, installing, testing and commissioning of grid connected Solar PV plant of 12.5 KW AC side with 15 KWp DC side capacity including ballasted type module mounting structure, solar grade DC copper cable upto inverter, array junction boxes, MC connectors, AC combination boxes, AC distribution board , junction / combiner boxes (including the module junction box, string junction box and main junction box equipped with appropriate functioning safety including fuses,SPD , grounding etc.) pump/motor with necessary piping system, valves, foundation/staging work, as conditions for Solar Panel comprising of following sub components/sub systems and installation accessories complete including having following features complete all as specified and as directed in the tender document. Note- BOQ Items from 109 to 195 shall be considered as one item of Solar PV plant and cost of these items are deemed to be included in this BOQ item No 109.
Solar PV Module Solar modules not less than 335 watts each as per detail technical specification mention in tender document. Modules should have efficiency of not less than 16% and the fill factor should be above 75% with cell and module both manufactured in INDIA. Make : Waaree / Vikram/Jackson/Emvee/Adani Solar/ Tata Power Solars Ltd/ Neosol/ Satvik Green / Rhaine Solar Voltage at Pmax - 37.25 V minimum for 72 Cells Current at Pmax - minimum 8.86A for 72 cells Open circuit voltage - 45.94 V minimum for 72 Cells Short cicuit current - minimum 9.41 Amps Maximum system voltage (Volts) - 1000 V DC Type of solar PV cell - Multi crystalline sillicon Suitability - For grid connected system Module output - MC electronics plug (Male and female) Certification - The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type, approved as per IEC61215/BIS14286
In addition, the modules must conform to IEC 61730 Part 1(A1+A2+A11)-requirements for construction & Part 2(+A1)-requirements for testing, for safety qualification
The modules must conform to IEC 61701 , IEC 62716 ,62804 PID resistant
Latest STC report should be provided from any MNRE authorized test lab , report should not be 3 months old from the date of tender
Application Class - A
Safety Class - A
Fire rating Class - C
All above electrical parameter measured - Standard test condition of irradiance of 1000 W/m², AM 1.5 and cell temperature of 25° C
Supply and installation of modules and installation is to be done as per the design and SLD submitted by contractor and approved by GE.
Solar module shall be inspected and tested in factory before despatch to the execution site.
Material Warranty:(i) The contractor should warrant the Solar Module(s) to be free from the defects and / or failures specified below for a period not less than 10 (ten) years from the date of completion of work. He will obtain similar warranty from the original manufacturer and will submit the same to the GE (MES) Ranikhet. However contractor will be responsible for the enforcement of warranty which shall include (a) Defects and / or failures due to manufacturing (b) Defects and / or failures due to quality of materials (c) Non conformity to specifications due to faulty manufacturing and / or inspection processes.
Module Mounting Structure
Design, Supply, Fixing, support structure MS Hot dipped galvanised minimum 85 microns thickness including PCC foundation for civil works (excavation in any type of soil / rock cutting grouting PCC 1:3:6 type C2 etc and fixing the mounting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 180 Km / Hour. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from solar PV panels Anti theft Nut Bolts supporting structures including module mounting structure shall have to be adequately protected fromatmosphere and weather prevailing in the area.
The minimum clearance of the structure from ground level should be 800mm or highest flood level mark recorded at the site and complete all as specified and directed.
IS 2061-1992 and galvanised as per IS-4759
The structure should be capable of withstanding a wind load of 180 km/hr after installation.
The material shall be corrosive resistant and electrically compatible with material used in module frame.
All fasteners shall be of stainless steel of Grade SS 316. The Module Mounting Structure to be of Manual Seasonal tilt of 0 degree to 40 degree to provide maximum generation.
The array structure shall be grounded properly using maintenance free earthing kit
All fasteners are to be used of SS304.
The mounting structures of solar PV modules, electrical works and overall workmanship of the grid solar power plant up to inverter must be warranted for a period minimum 05 (Five) years as detailed in Particular Specifications. If all the items fails to conform to this warranty, the contractor/ manufacturer will repair or replace the items at their own expenses.
Power Conditioning Unit (Inverters)
Supply and Installation and comissioning of Solar Grid Connected inverter of capacity 5 KW, 3 phase, 440 Volt, AC operated, 50 Hz, outoor type with following features complete all as specified and directed. Make : Delta/ABB/SMA/Polycab/Huawei/Solis/ Sungrow
The Power Grid should have the following salient features:-
The PCU / inverters should be tested from the MNRE approved test centres / NABL / BIS / IEC accredited testing-calibration laboratories.
The charge controller (if any) / MPPT units environmental testing should qualify IEC 60068-2 (1, 2, 14, 30) / Equivalent BIS standard. The junction boxes / enclosures should be IP 65 (for out door) / IP 54 (indoor) and as per IEC 529 specifications.
Built-in meter and data logger to monitor plant performance through external computer shall be provided.
The power conditioning units / inverters should comply with applicable IEC / equivalent BIS standard for efficiency measurements and environmental tests as per standard codes IEC 61683 / IS 61683 and IEC 60068-2 (1,2,14,30) / Equivalent BIS Standard
Economical requirements:-
(i) Maximum efficiency >98%.
(ii) Opti trace MPP tracking for best MPP tracking efficiency.
(iii) Active temperature management with Opti cool.
(iv) Bluetooth communication.
Simple requirements:-
(i) Three Phase Grid feed-in.
(ii) Cable connection without tools.
(iii) DC plug-in system.
05 KW INVERTER (3 No.):-
(1) Input (DC)
(i) Maximum input DC power - 10 KWp
(ii) Maximum Input voltage - 1100V
(iii) Operating voltage range - 200 V - 1000 V
(v) Max. input current - 34.3 A / 17/3 A
(vi) Connection type -6 Pairs MC4
(vii)Start up Voltage - 180 Volts
(2) Output (AC)
(i) Max. Output power - 5 KW
(ii) Nominal power -5 kW
(iii) Nominal output Current - 7.9 A
(iv) Nominal output Voltage - 400V
(v) Operating voltage range - ± 20%
(vi) Power factor (Adjustable) - 0.8 ind - 0.8 Cap
(vii) Output frequency- 50 HZ ± 5 HZ
(viii) Harmonic distortion, current < 3 %
(vi) Connection type -8 Pairs MC4
(vii)Start up Voltage - 180 Volts
(3) Environmental limits
(i) Degree of protection - IP65
(ii) Operating temperature - -20⁰ C to +50⁰ C
(iii) Maximum altitudue (above sea level) - < 4000m
(iv) User interface and communications- LCD Display
(v) Communication Port: RS 485
(vi) DC switch - DC relays
(4) Protection & Monitoring:-
(i) Ground fault monitoring
(ii) Anti islanding
(iii) Grid monitoring
(iv) DC reverse polarity
(v) AC and DC short circuit and over current
(vi) Over current/ over voltage and over temperature
SOLAR DC CABLES
Supply laying and testing Solar DC copper cables multi stranded conductor, XLPE or XLPO insulted, IR/UV protected conforming to TUV 2 PfG 1169/08.2007 as per the technical specification of size not less than 4 sqmm and maximum voltage drop shall be limited to 2%. The solar cable shall be laid for interconnecttion of PV modules, PV modules to DC DB and DC DB to inverter. Make : Polycab/ KEI/ Apar Cables/ Seichem/ Leoni Cables
Shall meet IEC 60227/IS 694, IEC60502/IS 1554 standard Temp range: -10 degree C to +80 degree C Voltage rating 660/1000V
Solar cable shall be as per specification TUV 2 PfG 1169/08.2007
Cable installation shall be as per IS 1255
All cables and conduit pipes shall be clamped to the rooftop, walls and ceilings with thermoplastic clamps at intervals not exceeding 50 cm. The DC cable size shall be minimum of 4.0 Sqmm copper,Solar cable shall be aesthetically tied to Module Mounting Stucture using UV resistant cable ties suitable for out door application.
DC DISTRIBUTION BOARD
Supply and installation of DCDBs for 5 KWp plant (03 Nos ) as per the specification and directed.
The DC distribution box shall be of the thermos-Plastic with UL 94 for fire safety and SS fasteners IP65 DIN-rail maintaining type .
DC surge protection devise (SPD), class 2 as per IEC 60364-5-53
The fuses IEC/ equivalent BIS standard should comply with applicable IEC/ equivalent BIS standard for general safety requirements for connectors, switches, circuit breakers, low-voltage switch gear as per standard codes IS/IEC 60947 (Part 1, 2 & 3), EN 50521 .
Number of DC SPD with specification : 1000 VDC , Up :1.9kv , Imax :40 KA , Ucpv : 585 V DC , Iscpv : 2000 A in DCDB should be EQUIVALENT TO No. of MPPTs in Inverter, number of I/P and O/P in DCDB should be equal to number of string inputs in the inverter
Each string should have DC fuse with specification , I - 15 Amp , 1000 Vdc with DC fuse Holder as per specification 1000 vdc , 30 a ,100ka SCCR as per IEC 60269-2-1,60947-3 , IP 20 on its positive side
DCDB with 2 IN 2 OUT - 3 Nos.
Supply and installation and testing of ACDBs for 15 KW roof top solar power plant including following components: Note :- Cost of BOQ Item from 196 to 203 shall be deemed to be included in this BOQ item No 196.
(i) AC circuit breaker, 4-pole AC surge protection device (SPD), class2 as per IEC 60364-5-53 ,AC SPD with specification for 3 phase and 1 neutral ,Uc :335V Ac , Up : 1.5 KV , In : 20 KA , Imax : 40 KA
(ii) Each ACDB should be having MFM with Accuracy class 0.5 , panel meter compatible with RS 485 communication compatible with remote monitoring system .
(iii) The panel shall be duly wired with suitable size of 1.1kV, PVC insulated cable and terminals shall be brought out for cable connections. 10% spare terminals subjected to minimum one of each rating shall be provided on each distribution switchgear.
(iv) 240 V, 15 A, 3 pin industrial socket-outlet with ON/OFF switch shall be provided in each panel
(v) Should comply with applicable IEC / equivalent BIS Standard for general safety requirements for connectors, switches, circuit breakers, low voltage switch gear as per standard codes.
Standard codes IS / IEC 60947 (Part 1, 2 & 3), EN 50521, IEC 61439-1 IEC 61439-2
Supply and installation and testing of ACDB 3 IN with 1 Out with SPD, MFM , Indicators, Circuit Breaker ,15 Amp socket ,IP65 ( suitable for 5 KW AC output) - 03 Nos MCB 4 Pole 32 Amp, 415 V, Breaking capacity -10 kAw- 01 No. complete all as specified and directed.
Supply and Installation of Remote Monitoring System GSM with Invertor suitable to have below mention sensor integration and all as specified in PS:- (a) 1 Pyronometers with 15 ft cable and prewired connectors - 1 Nos (b) Surface Mounted thermistor to measure solar panel Temperature - 01 No
Supply, laying and testing XLPE insulated, PVC sheathed single or multi-core flexible copper conductor cable of size 4 core 6 sqmm (Inverter to ACDB for 05 KW inverter) with UV-stabilized outer sheath , 650/100 volts conforming to IS 7098 part - 1/1988. Notes : (i) All cable/wires are to be routed in a GI cable tray and suitably tagged and marked with proper manner by good quality ferrule or by other means so that the cable can be easily identified. Solar cables shall be aesthetically tied to Module Mounting Structure using UV resistant cable-ties suitable for outdoor application. (ii) The total voltage drops on the cable segments from the solar grid inverter to the building distribution board shall not exceed 3.0%
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 core 3.5 sq. mm (from 1.5 KW ACDB to LT panel) fixing with suitable clamps on floors/ walls/ roof top all as specified and directed.
Supply and Installation of CPVC pipe as per IS 15778 ,ASTM D1784 , ASTM D2846 specification and standards with water outlet at every 5 meter of Solar module cleaning system , CPVC pipe with 30 mm dia water piping laid through out the solar module array installation with 30 mm outlet fitted with long handle ball valve, one UNION at every 20 running meter to be fitted for easy service and installation complete all as specified and directed. Note : Cleaning of solar panels is required twice a week.
Supply, Installation and Fixing ABC STORED PRESSURE TYPE FIRE EXTINGUISHERS each of capacity 4 kg as per IS 15683 , Range of jet 4 mtrs maximum period for which jet maintended 16 sec , working pressure -15 kgf/cm² , hydro pressure - 35 kgf/cm² , Bursting pressure -55 kgf/cm² , Fire Rating - 2A,34B , full weight - 6.75 kg complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XVI A (EXTERNAL WATER SUPPLY) (For details see Schedule 'A' Part-XVI A in PDF folder)
SCHEDULE 'A' PART-XVI B (EXTERNAL WATER SUPPLY)
M & L for connecting and testing of CI air release valve 100 mm size, ISI marked flanged type with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed
M & L for construction of brick masonary valve pit of size 900 x 900 x 900 mm (internal dimensions) with brick work of fly ash old size bricks built in cement morter 1:4 and 10mm thick rendering on internal and exposed external surface and including 40x40x6mm mild steel angle frame 3.15mm thick mild steel sheet cover in two Nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and all as directed.
M & L for Cutting existing steel tubing of size 100 mm for alternation or addition (each cut measured) complete all as specified and directed.
Supplying, testing and commencing of sluice valve 80 mm dia of cast iron body flanged and drilled as per ISI 14846 (ISI Marked) specifications class PN-1.6 with stainless nuts,bolts, washers & fibre / rubber gasket steel spindle complete all as specified and directed.
Supply, installing, commissioning of smart water meter of suitable for pipe size 50 mm diameter with GSM based SCADA system alongwith following specification (i) LED display 4 digit indication for flow rate and 8 digit indicator for Totaliser. (ii) Ingress protection IP-65 Response time 5 seconds (iii) Communication Port 485 MODBUS RTU/GPRS Flang /End connection Std.DIN/ A NSI /B S/SMS/T RI-clam P Material Pipe- SS 316 (non- Magnetic ) End connections/ Flanges : Carbon Steel /SS Epoxy painted. Power Supply 110/240 AC +- 15%, 15Hz Power consumption 20 VA, Cable gland entry , 105 inch NPT(F) Max load resistance 1000 ohms Flow velocity 0.3 to 10 M/s Make:- Flowrio HSN Code 9028 or equivalent in Peltek India / Unnati
Supply, installing, commissioning of smart water meter of suitable for pipe size 25 mm diameterwith GSM based SCADA system alongwith following specification (i) LED display 4 digit indication for flow rate and 8 digit indicator for Totaliser. (ii) Ingress protection IP-65 Response time 5 seconds (iii) Communication Port 485 MODBUS RTU/GPRS Flang /End connection Std.DIN/ A NSI /B S/SMS/T RI-clam P Material Pipe- SS 316 (non- Magnetic ) End connections/ Flanges : Carbon Steel /SS Epoxy painted. Power Supply 110/240 AC +- 15%, 15Hz Power consumption 20 VA, Cable gland entry , 105 inch NPT(F) Max load resistance 1000 ohms Flow velocity 0.3 to 10 M/s Make:- Flowrio HSN Code 9028 or equivalent in Peltek India / Unnati
Supply, installing, commissioning of smart water meter of suitable for pipe size 200 mm diameterwith GSM based SCADA system alongwith following specification (i) LED display 4 digit indication for flow rate and 8 digit indicator for Totaliser. (ii) Ingress protection IP-65 Response time 5 seconds (iii) Communication Port 485 MODBUS RTU/GPRS Flang /End connection Std.DIN/ A NSI /B S/SMS/ T RI-clam P Material Pipe- SS 316 (non- Magnetic ) End connections/ Flanges : Carbon Steel /SS Epoxy painted. Power Supply 110/240 AC +- 15%, 15Hz Power consumption 20 VA, Cable gland entry , 105 inch NPT(F) Max load resistance 1000 ohms Flow velocity 0.3 to 10 M/s Make:- Flowrio HSN Code 9028 or equivalent in Peltek India / Unnati Note:- These meters are to be used for measurement of rain water harvesting.
Total amount of SCHEDULE 'A' PART-XVII A (EXTERNAL ELECTRIC SUPPLY) (For details see Schedule 'A' Part-XVII A in PDF folder)
SCHEDULE 'A' PART-XVII B (EXTERNAL ELECTRIC SUPPLY)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
95 sq mm 3½ core
25 sq mm 4 core
16 sq mm 2 core
10 sq mm 4 core
10 sq mm 2 core
6 sq mm 2 core
Supply, laying, jointing and testing HT XLPE cable of cross sectional area 95 Sqmm 3 Core 11000 V screened, PVC E Grade insulated bedded galvanised steel (heavy duty) strip or wire armoured with aluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-I) 1977 and part-II of 1985 laid in pipes / ducts / trenches under floor and roads or fixed to wall etc complete all as specified and directed.
Supply and lay burnt fly ash bricks old size laid dry in trenches across the cable protection complete all as specified and directed.
M & L for stringing, stretching and strengthening of overhead conductor (ACSR) on LT steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire of size ACSR conductors of size 3 of 6/1x2.59 (weasel), 1 of 6/1 x 2.11 mm (Squirrel) complete all as specified and directed.
S & F HT disc type porcelain vitreous white, brown, or green insulator of size 145 mm high and 255 mm dia ball and socket type for two in series assembly with tension clamp for conductor for working pressure 11000 volts complete all as specified and directed.
S & F HT Cable / route indicator cast iron of suitable size along with HT cable trench including planting in ground with PCC complete all as specified and directed.
M & L Steel tubular swaged pole complete with 300mm x 300mm & 6mm thick mild steel base plate continuously welded to pole finial taper plug , bolts nuts & screws as specified type 410 SP 31 (09 mtr long ) including factory painted with two coats of black bituminons paint internally throught out and externaly on embedded portion and applying two coat of Aluminium paint over a coat of red oxide primer on remaining exposed surface after erection in position, complete all as specified and directed by Engineer-in-Charge. Note : Excavation and earth work and foundation concrete shall be measured and paid separately.
M & L for Steel tubular swaged pole complete with 300mmx300mm & 6mm thick mild steel base plate continuously welded to pole finial taper plug , bolts nuts & screws as specified type 410 SP-22 (8.5 meter long) including factory painted with two coats of black bituminons paint internally throught out and externaly on embedded portion and applying two coat of Aluminium paint over a coat of red oxide primer on remaining exposed surface after erection in position, complete all as specified and directed by Engineer-in-Charge. Note : Excavation and earth work and foundation concrete shall be measured and paid separately.
Supply and fixing LED Security light 36 Watt luminaire fitting (IP 66 powder coated pressure die cast aluminium High power LED Street light with heat resistant toughened glasswith lens with electronic driver) Fitting will be fitted with GI pipe light grade Bracket 1.2 mtr long 40 mm dia fixed wall with suitable size MS clamp of size 50x6mm including nut, bolts and washers and making connection with using 2.5 sqmm PVC insulated Multistranded copper conductor two single core cable complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 4 Pole MCCB 160Amp, 50 Hz, 415 V with rupturing capacity 25 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model complete all as specified and directed
Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 300x200x100 mm complete all as specified and directed by Engineer-in-Charge. Make sintex / hensel/ Universal
Design ,Supply installation, testing and commissioning of Outdoor type Feeder Piller Box (CPRI approved ), totally enclosed fabricabted out of 50 x 50 x 6 mm angle iron and 3.15 mm thick CRCA sheet with hinged door, dust & vermin proof of size not less than 1.5 x 1.0 x 0.6 mm with 3 phase 4 wire copper bus bar 200 amps for phases and half for netural rating with the following accessories :- (a) Incoming MCCB 4 pole 160 amp 415 volts grade rupturing capcity (25 KA)- 01 Nos (b) Outgoing MCCB 3 pole 100 amp 415 volts grade repturing capcity (25 KA) - 02 Nos (c) Out going MCB SPN 10 amps, 240 volts grade with capacity 10 KA - 01 Nos (d) Digital ammeter 3.5 digit with 3 Nos CTs of ratio 200/5 amps - 01 Nos (e) Digital voltmeter 31/2 digit - 01 Nos (f) Indicator lamps RYB (Set of 3) - 01 Set (g) Timer Switch MaxiRex 4QTB (daily with IP 53 box)
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to GI earth strip 32 X 6 mm dia by means of nuts, bolts, check nuts & washers GI earth strip in case in and including 40 mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr including earth work/excavation in hard/dense soil, common salt, charcoal etc., PCC 1:2:4 type B-1 as in earth pit. RCC pit cover cover 50mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia mild steel round bars @ 150 mm c/c both ways with 10mm dia MS bar for lifting handle including 20mm dia GI pipe medium grade 1.5 long as watering pipe, GI sheet 0.63 mm thick funnel, wire mesh etc complete all as specified and shown in electric plate No 3 of SSR Part-I 2009 on page No 497 including testing on completion etc complete all as specified and directed. Note: - On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed Note: - On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
M & L for street light bracket of size 40 mm dia medium grade GI pipe of 0.9 Mtr length with 2 Nos clamps and nuts with bolts complete all as specified and directed.
M & L for MS cross arms, bracing, striffeners, support clamps and back plate fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size or as indicated or directed including two coats of enamel paint over a coat of red primer complete all as specified and directed.
S & F stay assembly comprising GI stay bow 400 x 14 mm, GI sheet stay rod 1800 mm long x 16mm dia with nut-bolts washers, GI steel plate 230 x 230 x 6 mm, two nos thimble loop insulator of size 65 x 90 mm clearance of hole 16mm stay wire of GI stay strand of size 7 x 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earthwork in hard dense soil PCC 1:3:6 type C-2 block complete all as specified and directed.
Supply, installation, testing & commissioning of 1 Phase 2 wire , Smart Energy Meter, IS : 16444 Part 1 & class 0.5 as per IS 16444: 2015 Part 2. marked in Meter Board/Floor Panels Making good the distributed wiring .Meter cosidered for the following details (i) Meter rating in single phase 5-30 , operated variants. (ii) LCD type display with backlit. (iii) Separate LED for relay status (iv) Internal latching relays for demand & Load control. (v) Ideal for remote Data Monitoring & Control, AMI/ Smart grid. (vi) Suitable for net Metering. (vii) Two way communication between meters & server for cellular communicatiion and DCU & server for LPRF communication. (viii)Time of day feature to monitor energy consumed in various time of day for efficient load management. (ix)Tamper event detection, recording and reporting. (x) Power event alarm such as Power Outage , Low & High voltage. Over the air configuration of Programming parameters like TOD , Billing date & time , integration period configuration etc as per IS 15959 Make- HPL cat part No SPSM01 or equivalent in Genus power infra or Schneider Electric.
Supply, installation, testing & commissioning of 3 Phase 4 wire , Smart Energy Meter, IS : 16444 Part 1 & class 0.5 as per IS 16444: 2015 Part 2. marked in Meter Board/Floor Panels Making good the distributed wiring .Meter cosidered for the following details (i) Meter rating in Three phase 20-100 A, operated variants. (ii) LCD type display with backlit. (iii) Separate LED for relay status (iv) Internal latching relays for demand & Load control. (v) Ideal for remote Data Monitoring & Control, AMI/ Smart grid. (vi) Suitable for net Metering. (vii) Two way communication between meters & server for cellular communicatiion and DCU & server for LPRF communication. (viii)Time of day feature to monitor energy consumed in various time of day for efficient load management. (ix)Tamper event detection, recording and reporting. (x) Power event alarm such as Power Outage , Low & High voltage. Over the air configuration of Programming parameters like TOD , Billing date & time , integration period configuration etc as per IS 15959 Make- HPL cat part No PPSM01 or equivalent in Genus power infra or Schneider Electric.
Total amount of SCHEDULE 'A' PART-XVIII A (DEMOLITION / DISMANTLING) (For details see Schedule 'A' Part-XVIII A in PDF folder)
SCHEDULE 'A' PART-XVIII B (DEMOLITION / DISMANTLING)
Dismantling of Old U/s DB's including MCB's any make and capacity complete all as specified and directed.
Dismantling of Old U/s Tube light fittings any type, make and capacity complete all as specified and directed.
Dismantling of existing service cable/UGcable, of size 6 sqmm 2 core to 16 sqmm 2 core complete all as specified and directed.
Dismantling of existing GI pipe 80 mm size any type complete kept aside complete all as specified and directed.
Dismantling of existing GI pipe 100 mm size any type complete kept aside complete all as specified and directed.
Dismantling of existing GI pipe 150 mm size any type complete kept aside complete all as specified and directed.
Dismantling existing stay assembly, including necessary excavation & Earthwork, demolition of concrete etc. and removing the old unserviceable rubbish etc outside complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 8,19,823.30 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Sood Enterprises
BHARATSHAH CONSTRUCTION CO
PK Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid