Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.4 LAccepted-AOC VILL NEPALPARA P O P S SERFANGURI DIST KOKRAJHAR BTC ASSAM | SERFANGURI | KOKRAJHAR | ASSAM | L1 | Accepted-AOC L1 | |
| 2 | L2₹80.7 L+₹30,265.71 (0.38%)Rejected-AOC S O SHRI MANIK CH NARZARY VILL GHOSHKATA P O BANARGAON P S DOTMA DIST KOKRAJHAR BTC ASSAM | DOTMA | KOKRAJHAR | ASSAM | L2 | Rejected-AOC L2 | |
| 3 | L3₹80.7 L+₹36,630.25 (0.46%)Rejected-AOC VILL BORO GENDRABIL P O DIST KOKRAJHAR BTR ASSAM | KOKRAJHAR | ASSAM | L3 | Rejected-AOC L3 |
Tender Value
₹80.4 L
EMD Value
₹1.6 L
Closing Date
12 Feb 2024, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sri Padmananda Choudhury
O/O Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajha.
Construction of RCC Box Cell Bridge No. 1by1 size 4by4, 4 cell and Bridge No. 1by2 Size 3by3, 2 cell on Buri River and Mwjlai Beel at Surjyakhata to Gwthwibari village road under BTR for the year 2023-24. TN No.64_07
2024_BTC_35588_1
27/KOJ/NIT/Pt-II/2023-24/66
Open Tender
Civil Works – Roads
Item Rate
365 days
Kokrajhar
Refer to Tender Documents
4 documents required · 4 mandatory
₹2,000
₹1.6 L
Yes
6 Mar 2024
20 Jan 2024
13 Feb 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
20 Jan 2024 - 12 Feb 2024
Amount
16.70 Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m with jungle wood post 20cm to 25cm dia 5nos. In each cows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm. or more below ground level including providing 20cm to 25cm center to center and placed over 20 cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mmx100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210cm apart and white washed including all necessaryt nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department.
16.79 Labour for dismantling all members of the timber bridge (excluding piles) with necessary scaffolding, jati bamboos jumper ropes etc, complete and stacking them at suitable places as directed (all members will be under custody of the contractor till taken over by the department)
3.4 Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private land.
10.2A(IV) Providing and fixing of retro-reflectorized coutionary, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 (IV) 80 cm x 60 cm rectangutar
16.28 RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including cantering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and -as directed. (a) 30cm dia RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
RCC BOX CUL. (SIZE: 2 Cell x 3.00M x 3.00M) 11.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Marshy soil
11.2 Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel I. P.C.C grade M 10 (i) Nominal mix 1:3:6
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel IV. R.C.C grade M 20
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel III. P.C.C grade M 20 (i) Nominal mix 1:2:4
12.5 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 B. With Natural Gravel IV. R.C.C. grade M 25 (i) For height up to 5m
11.7 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATN/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202.
12.7 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar SAI/BISCON/ THERMAX or equivalent)) in substructure complete as per drawings and technical Clauses 1002, 1005, 1010 & 1202.
12.9 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clause 614, 709, 1204.3 7
12.10 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 A. Granular material
13.1 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification Clauses 800, 1205.4 and 1205.5 B. With Natural Gravel II. R.C.C M 25 (a) Height up to 5m
13.3 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar. (Other ISI approved TMT reinforcement bar (SAI/ BISCON/ THERMAX or equivalent) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
13.5 Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 B. With Natural Gravel
13.6 Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
14.9 Providing and laying curtain Walls complete as per drawing and technical specification Clause 1304 III. Cement concrete grade M10
13.10 Drainage Spouts complete as per drawing and Technical specification.
Flexible Apron : Construction of flexible apron m thick comprising of loose stone boulders weighing not less than 25 kg beyond curtain wall.
(SIZE: 4 Cell x 4.00M x 4.00M) 11.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Marshy soil
11.2 Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel I. P.C.C grade M 10 (i) Nominal mix 1:3:6
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel IV. R.C.C grade M 20
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural gravel III. P.C.C grade M 20 (i) Nominal mix 1:2:4
12.5 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 B. With Natural Gravel IV. R.C.C. grade M 25 (i) For height up to 5m
11.7 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATN/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202.
12.7 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar SAI/BISCON/ THERMAX or equivalent)) in substructure complete as per drawings and technical Clauses 1002, 1005, 1010 & 1202.
12.9 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clause 614, 709, 1204.3 7
12.10 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 A. Granular material
13.1 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification Clauses 800, 1205.4 and 1205.5 B. With Natural Gravel II. R.C.C M 25 (a) Height up to 5m
13.3 Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar. (Other ISI approved TMT reinforcement bar (SAI/ BISCON/ THERMAX or equivalent) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
13.5 Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 B. With Natural Gravel
13.6 Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
14.9 Providing and laying curtain Walls complete as per drawing and technical specification Clause 1304 III. Cement concrete grade M10
13.10 Drainage Spouts complete as per drawing and Technical specification.
Flexible Apron : Construction of flexible apron m thick comprising of loose stone boulders weighing not less than 25 kg beyond curtain wall.
Nabaraj Narzary
DHILAN BASUMATARY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .