| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC | L1 | Accepted-AOC since accepted as L1 | |
| 2 | L2₹2.3 L+₹5,184.30 (2.34%)Rejected-Finance | L2 | Rejected-Finance Rejected since L2 | |
| 3 | L3₹2.3 L+₹11,486.30 (5.19%)Rejected-Finance | L3 | Rejected-Finance Rejected since L3 |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
1 Jan 2024, 6:55 pmClosed
SO(EnM)
GM UNIT KUJU
Electrical rewiring/repairing and illumination of 02 nos of checkpost and old pit office of Karma Project under Kuju Area.
2023_CCL_296754_1
GM (K)/EnM/eTender/23-24/147
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹3,000
1 Feb 2024
21 Dec 2023
2 Jan 2024
21 Dec 2023
1 Jan 2024
21 Dec 2023
21 Dec 2023 - 27 Dec 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.GROUP A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.GROUP B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 63A TPN
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 6 sq. mm
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Supply & fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding moduar plate etc. as required a) 5/6 Amp switch
Supply & fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding moduar plate etc. as required b) pin 5/6 amp socket outlet
Supply & fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding moduar plate etc. as required c) 15/16 Amp switch
Supply & fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding moduar plate etc. as required d) 6 pin 15/16 amp socket outlet
Providing & fixing of 18 Watt LED tubelight
Total impact of GST for the purpose of CTC
M/S KRISHNA SINGH
SEEMA CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .