Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.6 L+₹13,200.15 (1.57%)Rejected-Finance PALAKKAD | KERALA | 678001 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | M C KURIAKOSE L1 | BIJO KURIAKOSE L2 |
|---|---|---|---|---|---|
| 1.00Interlock Tile | |||||
| 1.00 | OD452204/2025-2026:Dismantling and stacking Interlocking concrete block pavements having thickness 80
mm or nearest, reuse concrete block ( unusable)as per drawing &technical specification clause
1504. | 352.5 | sqm | 60 ₹21,150 Lowest | 70 ₹24,675 |
| 1.00 | 11.1.1.1:Excavation for Structures <br> Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. <br> I. Ordinary soil <br> (i) Upto 3 m depth | 8.4 | cum | 940 ₹7,896 Lowest | 950 ₹7,980 |
| 1.00 | 11.4.1.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6 | 2.1 | cum | 9,000 ₹18,900 Lowest | 9,100 ₹19,110 |
| 1.00 | 12.5.3:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204<br> For height upto 5 m <br> III. R.C.C grade M 20 | 11.62 | cum | 10,450 ₹1,21,481.25 Lowest | 10,460 ₹1,21,597.5 |
| 1.00 | 12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 | 0.99 | tonne | 1,00,000 ₹98,800 Lowest | 1,00,000 ₹98,800 Lowest |
| 1.01 | OD451836/2025-2026:Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. | 130.12 | cum | 1,230 ₹1,60,053.75 Lowest | 1,240 ₹1,61,355 |
| 1.01 | 4.1.A.3:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.<br> (iii) For Grading III Material | 35.25 | cum | 3,300 ₹1,16,325 Lowest | 3,350 ₹1,18,087.5 |
| 1.01 | OD452205/2025-2026:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line,
level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse
sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (Old CC paver blocks shall be supplied by the department free of cost.) | 211.5 | sqm | 475 ₹1,00,462.5 Lowest | 500 ₹1,05,750 |
| 1.01 | OD451837/2025-2026:Providing and laying Interlocking concrete block pavements having thickness 80mm over 50mm thick crushed stone chips of 6.7mm size as per drawings and technical specification | 141 | sqm | 1,165 ₹1,64,265 Lowest | 1,170 ₹1,64,970 |
Tender Value
₹8.5 L
EMD Value
₹21,172
Closing Date
5 Mar 2026, 11:00 amClosed
Assistant Engineer
LID and EW Sub Division Pattanakkad
Pattanakkad BP-2025-26-Proj no.181/26-Construction of Kunnel Harijan Colony road in ward 3 of Kuthiyathodu GP
2026_LSGD_840459_1
45/AE/LIDEW/PKD/25-26
Open Tender
Civil Works - Roads
Item Rate
240 days
Pattanakkad
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,870
₹21,172
27 Jun 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Interlock Tile
OD452204/2025-2026:Dismantling and stacking Interlocking concrete block pavements having thickness 80 mm or nearest, reuse concrete block ( unusable)as per drawing &technical specification clause 1504.
11.1.1.1:Excavation for Structures <br> Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. <br> I. Ordinary soil <br> (i) Upto 3 m depth
11.4.1.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br> I. P.C.C grade M 10 <br> (i) Nominal mix 1:3:6
12.5.3:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204<br> For height upto 5 m <br> III. R.C.C grade M 20
12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
OD451836/2025-2026:Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
4.1.A.3:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.<br> (iii) For Grading III Material
OD452205/2025-2026:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (Old CC paver blocks shall be supplied by the department free of cost.)
OD451837/2025-2026:Providing and laying Interlocking concrete block pavements having thickness 80mm over 50mm thick crushed stone chips of 6.7mm size as per drawings and technical specification
75.8.1.1.A:Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
OD451834/2025-2026: Granite for name board of size 75 cm x 60 cm with letters
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1416840.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
kunnel.pdf
Tender Documents • 1.64 MB
NITkunnel.pdf
Other Document • 0.03 MB
BOQ_1416840.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .