Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | Admitted-Finance |
Tender Value
₹98.8 L
EMD Value
₹2.0 L
Closing Date
4 Jan 2024, 12:00 pmClosed
SO1 (Wks)
HQ 25 Sect AR Jorhat (Assam)
Special repair of COB/OCB, LT Pannel, LT, HT Line, Street light, servicing of transformer and repair/servicing of gen sets at AR Bn Charduar of 12 Assam Rifles (Now 23 Assam Rifles)
2023_ARMHA_784286_1
25 Sect/7900/Engr/Spl R/2023/24
Open Tender
Civil Works
Works
23AR Charduar(Assam)
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
DIGAR
₹2.0 L
27 Jan 2024
7 Dec 2023
5 Jan 2024
7 Dec 2023
4 Jan 2024
7 Dec 2023
7 Dec 2023 - 4 Jan 2024
Schedule A Part-I Dismantling of over head lines compromising of copper/aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (AS PER GROUND REQUIREMENTS) @ 0,214kg/mtr
Dismantling of over head lines compromising of copper/aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (AS PER GROUND REQUIREMENTS) @ 0,214kg/mtr
Dismantling of over head lines compromising of copper/aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (AS PER GROUND REQUIREMENTS) @ 0,214kg/mtr
Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc. as required. AS PER GROUND REQUIREMENTS
Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc. as required. AS PER GROUND REQUIREMENTS
Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc. as required.AS PER GROUND REQUIREMENTS
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia x 1.8 meters long stay rod, anchor plate of size 45 cm x 45 cm X 7.5 mm thick, thimble, size clamps, turn buckle (20 mm X 600 mm), 7/4.00 mm dia G.I. Stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded ctone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Set 3,297.00
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/cross arm for single 11 KV over headline conductor complete with 50 mm x 6 mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. Pin, nuts washers eetc as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm). G.I. Bolts, nuts and washers, coach screws etc. As required.
Erection f ACSR coonductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. As required.
Erection of G.I. Wire No 8 SWG including binding etc. As required.
Erection of stay set complete (galvanised) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. As required.
Earthing with G.I. Earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. With charcoal/ coke and salt as required. Every fourth pole for security light.
Providing and fixing M.V danger notive plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing 16/0.20 mm (0.50 sq mm) twin flat flexible, FR PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/wall, or side of the table/door etc. As required.
Supply of steel tubular poles complete with welded base plates size of 30 x 30 cm final tapper pole laps (410 SPT 31-9 Mtr. Long)
Supply L.T.O Lines on existing poles with ACSR conductor of 7/3.35 mm for three phase line street light respectively.
Providing L.T.O.H. Lines on existing poles with ACSR conductor of 7/3.35 mm for three phase line street light respectively
Providing and installation of street light fitting 70 watt LED type complete with all as specified and instructed Ingineer-in-Charge.
M & L for painting of 9 Mtr LT steel tubular poles by two coat of aluminium paint over one coat of primer.
Supply and fixing 63 amps switch with panel board of MS sheet with stand complete with fuse etc. As required.
Providing of 8 SWG GI wire on existing pole with ACSR conductor etc. Complete.
Supplying and fixing 50 mm dia GI pipe x 3.00 mtr length light grade along the pole for protection of underground cable as required.
supply and Fixing of KW energy meter single phase 230 V house service type minimum rating up to 25 amps
Supply and erecting Iron work of various sections for panel board (feeder pillar frames)
Providing Cement concrete foundatin for Feeder pillar in 1:2:4 with required size adn length of foundation with bolts and nuts
Supply, Erection, testing PVC armoured cable laid in provided trench/pipe as per specification (LOCAL DISTRIBUTION AS PER GROUND REQUIREMENTS) 3-1/2 core 500 sq mm aluminium conductor
Supply, Erection, testing PVC armoured cable laid in provided trench/pipe as per specification (LOCAL DISTRIBUTION AS PER GROUND REQUIREMENTS) 3 1/2 CORE 95 sq mm aluminium conductors
Supply, Erection, testing PVC armoured cable laid in provided trench/pipe as per specification (LOCAL DISTRIBUTION AS PER GROUND REQUIREMENTS) 3 1/2 CORE 70 sq mm aluminium conductors
Supply, Erection, testing PVC armoured cable laid in provided trench/pipe as per specification (LOCAL DISTRIBUTION AS PER GROUND REQUIREMENTS) 3 1/2 CORE 50 sq mm aluminium conductors
Supplying, making cable end termination with brass compression glands for the following cable of 1.1 KV grade etc, complete as required. 3-1/2 core 185 sq mm aluminium conductor
Supplying, making cable end termination with brass compression glands for the following cable of 1.1 KV grade etc, complete as required. 3-1/2 core 95 sq mm aluminium conductor
Supplying, making cable end termination with brass compression glands for the following cable of 1.1 KV grade etc, complete as required. 3-1/2 core 70 sq mm aluminium conductor
Supplying, making cable end termination with brass compression glands for the following cable of 1.1 KV grade etc, complete as required. 3-1/2 core 50 sq mm aluminium conductor
Providing and fixing cable route marker as per specification
making the trench in Murom as per IS for laying LT cable of 25 sq mm and covered with Half round hume pipe, as per specification
Laying RCC Hume pipe with collar depth upto 90 cm for enclosing cable & necessary back filing to make the surface as it was
Providing and fixing LT line separator as per specification and directed by Engineer-in-Charge
Schedule of Credit Old U/S Al conductors etc.
Old U/S Al conductors etc.
Old U/S Al cables etc.
M/S PURBANCHAL BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .