Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.5 L+₹39,502.50 (0.94%)Rejected-Finance BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹44.1 L+₹2.1 L (4.92%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹46.5 L+₹4.4 L (10.4%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L4 | Rejected-Finance Other than Lowest Tenderer | |
| 5 | L5₹46.7 L+₹4.6 L (10.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
13 Mar 2024, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS TO BLDG NO T-162 (BRISTOW HOUSE) AT INS DRONACHARYA UNDER GE FORT KOCHI
2024_MES_639645_1
8992/E8/GE_FORT_KOCHI
Open Tender
Civil Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹97,000
Yes
12 Sept 2024
5 Feb 2024
20 Mar 2024
5 Feb 2024
13 Mar 2024
28 Feb 2024
Amount
Dismantling of Single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed
Dismantling framed work timber scantlings 40 sq. cm and over in section, in any position and in any direction complete all as specified and as directed
Dismantling framed work timber scantlings like fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position and in any direction complete all as specified and as directed
Dismantling of battens for tiles, shingles etc, of any size including tilting fillets of space execeeding 15 cm complete all as specified and as directed
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed
Dismantling of plain or corrugated steel any gauge, thickness, including Nainital or similar pattern roof covering, all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Taking down chowkhats or frame with shuters (without taking shutter from frame) exc 1.5 sqm and n. exc 4.0 sqm and removing from site all as specified.
Taking down chowkhats or frames not exc 1.5 sqm with shutter(without taking of shutter from the frames) including hold fasts and PCC block, all as specified.
Taking down shutter of any description, shutters of any description n exc 1sq. m each and removing from site all as specified.
Taking down shutter of any description, exceeding. 1 Sqm and not exceeding 2 sqm each and removing from site all as specified.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises all as specified
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified.
M&L for clean sawn 2nd class hard wood battens at 25 cm cm centre to centre cross sectional area exceeding 15 and not exceeding 25 sqcm, all as specified
Fixing olny clean sawn 2nd class hard wood battens at 25 cm cm centre to centre cross sectional area ecxeeing 15 and not exceeding 25 sqcm. The servicebale battens obtained from item No 4 shall be re used all as specified
M&L roof tiles, Mangalore pattern, interlocking at side joints, laid dry at any position and in any direction all as specified
Fixing olny roof tiles, Mangalore pattern, interlocking at side joints, laid dry at any position and in any direction. The serviceable mangalore tiles obtained from item No 1 shall be re used
M&L ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6
S&F second class hard wood Wrought sawn timber framed and fixed scantlings as in wooden truss, purlins wall rafter and similar work etc complete all as specified and as direcected
Fixing only second class hard wood Wrought sawn timber framed and fixed scantlings as in wooden truss, purlins wall rafter and similar work etc complete all as specified and as direcected. Serviceable Scantlings obtained from item No 2 shall be reused
S&F pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per profile and shade as approved by GE. all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per profile and shade approved by GE all as specified.
M&L 2nd class hard wood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed all as specified.
M&L False ceiling with 12mm thick 1.20m x 1.80m Gypsum board false ceiling sheets fixed with machine screws on and including GI channel 22 gauge thick grid work, main joists placed at 1.20m centre to centre, cross joists placed at 450mm centre to centre, hanging with 22 gauge GI strip suspenders from roof, ‘J’ hooks bolts and nuts etc and treating the Gypsum board sheets with thin layer of POP with Gypsum anhydrous binder including POP cornices of any design and pattern and prepare the surface till smooth surface is achieved and applying two coats of plastic emulsion paint of any pattern and design over a coat of texture primer on ceiling sheets all complete as required as per manufacturer’s instructions and as directed by the Engr-in-Charge. Notes : 1. The pattern and design shall be as directed by the Engr-in-Charge during the execution of work. 2. The exposed surface of the false ceiling shall be joint less, even and smooth to receive two coats of oil bound distemper 3. The Gypsum board Sheets shall be fixed with suitable screws below the grid and shall not be placed over the grid.
S&F rolled mild steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections confirming to Fe-410W (Gde-250 quality-B) including distance pieces, cleats etc.all as specified.
S&F plain plates square cut or notched (ordinary and counter suk) forming holes, without any attachment.all as specified.
S & F mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 15 cm and n exc 30 cm,all as specified.
S & F mild steel 25x3mm MS Flat for holdfast, cleat etc. for door frame etc. conforming to Fe-410-0 or Fe-310,all as specified.
M & L PCC 1:3:6 type C1 (using 20 mm graded agg.) as in hold fast block incl. necessary form work complete all as specified and directed.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified.
M & L two coat of synthetic enamel paint over a coat of red oxide on steel surface including preparation of steel surface width or girth exc 10cm all as specified and directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
M & L for pre-cast cement concrte block masonry with solid blocks Type C1 1:3:6 ( 20 mm gradd aggregate), exc.10 cm in width and setting in CM 1:6 , all as specified.
M&L rendering cement plaster15mm thick in cement mortar (1:6) & finishing the surface even & smooth without using extra cement complete all as specified & directed.
M&L rendering cement plaster15 mm thick on fair face of brick work or concrete surface finished even smooth with out using extra cement .in CM (1:4) ,all as specified.
S&F 35 mm thick II class HW Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered orrounded. fitted with cut and mitred beads for securing glass, etc.; as per section 8.24 (a) sizes of me-mbers of shutters as specified .
S&F for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed including takig down old un servicable one.
S&F 100 mm size Mild steel butt hinges medium weight, fixed to chowkhat all as specified and as directed by Engineer-In-Charge.
S & F 100 mm long aluminium anodised barrel tower bolt all as specified and as directed by Engineer-In-Charge.
S&F 250 mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified.
S&F 300 mm, size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified.
M&L Preparation of new wooden surface of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over pink prime including preparation of new wooden surface all as directed and as specified all as specified.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises all as specified
Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) all as specified.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection, paving including finishing the surface even and fair complete, all as specified.
M&L for dark shade vitrified ceramic tiles 8-10 mm thick polished area of each tiles not exc 0.36 sqm of any shade and any pattern (Pattern consists combination of two or more tiles ) as in floor etc jointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 15mm thick screed bed in CM 1:6 and pointed in colored cement to match coloured tiles..(The Colour,shall and pattern shall be approved by the GE during execution work). (No extra cost shall be allowed for removing and re-fixing and necessary cutting of door etc if any required during execution of work, all as specified.
-Ditto-all as per item No 47 above but in vertical surfaces like skiting / dado etc all as specified and directed ..(The Colour,shade and pattern shall be approved by the GE during execution work). (No extra cost sahll be allowed for removing and re-fixing and necessary cutting of door etc if any required during execution of work.
M & L for preparation of new plastered/concrete surfaces of walls, providing one or more coats of Birla white wall care putty to achieve smooth surfaces and applying two coats of distemper oil emulsion of approved shade/tint over a coat of compatiable priming paint complete all as specified.
M & L for applying two coats of exterior grade emulsion weather coat over a coat of primer including preparation of newly plastered surfaces complete all as specified and as directed.
M&L preparation of existing treatment of old surface including brooming down , scrapping down smoke soot,mould, moss and efforescent salts and trading oil and grease spouts and cleaning with water on wall applying one coats of acrylic emulsion (exterior weather coat) paint of any tint as approved complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing the surfaces of batten of Tiles or slate battens, any size and spacing, prepared and treated all over (measured overall on one side only, spaces not deducted) with and trated with creosote complete all as specififed and as directed
M&L glazed and skeleton 30mm thick Window shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specififed
S&F plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted all as specififed
M&L for French polishing on surface of any description width or girth including cleaning and preparing the surface with a coat of wood filler on new work and two or more coats till the desired finish is obtained ,all as specified.
M&L for french polishing on old surface of any description width or girth including cleaning and preparing the surface with a coat of wood filler on new work and two or more coats till the desired finish is obtained, all as specified.
Hacking out old broken glass in alunimium/ wooden /steel windows and doors of any description (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, all as specified.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each all as specified.
M & L preparation of old distempered and painted surfaces including washing, rubbing down and stopping by brooming down ,scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of distemper oil emulsion on wall surfaces all as specified.
M&L preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote, all as specified.
M&L for preparation of new o old Mangolore pattern roof tile surfaces by washing, rubbing, brooming down or steel wire brushing or scraping down smoke soot, moulds, mass and efflorescent salts and applying one coat of exterior emulsion weather proof antifungal Terracota paint on MP tile roof surfaces including necessary scaffolding and saftety measures complete all as specified and as directed.
M&L for carrying out ATT treatment along the surface of external wall below concrete of masonry work by using chemical emulsion @ 2.25 ltrs per liner meter incl drilling and plugging holes etc complete all as specified and as directed
M&L for carrying out ATT treatment at points of surface contact of wood or wood based material by using chemical emulsion in oil of kerosone based solution @ 0.5 ltrs per liner meter incl drilling 6mm di holes at a downgrad angle of 45 degree at 150 mm centre to centre and sealing the same all as specified and as directed
Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc all as specified
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with same make of modals switch /Sockets with earth duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting wall/PCC, chasses and making good disturbed surface to match with existing finish with plaster complete for One light point controlled by one, one way switch 5 Amps all as specified and directed
-Ditto- all as per item No 67 for one fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
-Ditto- all as per item No 67 for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
-Ditto- all as per item No 67 for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
-Ditto- all as per item No 67 for One bell point controlled by one, bell switch 5 Amps
-Ditto- all as per item No 67 for here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
-Ditto- all as per item No 67 here in before but using 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket point including 4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point)
M & L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia of medium grade complete with ISI marked and including all PVC conduit accessories fixed on wall or roof and making good to the disturbed surfaces complete one fan/light point controlled by one 6 amps switchesall as specified and directed
-Ditto- all as per item No 74 one 3 pin socket outlet, 05 Amps, independent with cable 1.5 5q mm size. Note for Item No 67 to 75 : The quoted trates are inclusive of metal box ,modular switch ,framed and cover plates etc.
S&F Modular switch 06 Amp, one module single pole, one way, 230 Volt complete all as specified & directed.
S&F Modular switch 16 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F Modular bell push flush, 06 Amp, Volt complete all as specified & directed
S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S&F Modular socket outlet 2/3 pin pin, 06 Amp flush type, 230 volt, complete all as specified and directed
S&F modular socket outlet multi purpose 2/3 pin 06 Amp and 16 Amp flush type, 230 volt, complete all as specified & directed.
S&F ding dong bell, AC, 230 volts, single pole complete all as specified & directed
S & F Modular fan regulator step type AC, 120W two module complete all as specified & directed
Disconnection of electrical wire from ceiling rose and taking down ceiling Fan of any type/size,make moreover dismantling the ceiling Fan for removing of old lubricating substatance from bearing/bush & applying fresh lubrication using grease to avoid noise free smooth functioning, including rewinding , replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird ceiling fan to the entire satisfication of engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as specified
Supply and fix in renewal of surface mounted LED tube light fitting four feet long, 22 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as directed.
M & L for sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc with one run of 10 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note : 5 runs of 10 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
M & L for sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one runs of PVC insulated with 4 qmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- 5 runs of 4 sqmm cable, one runs of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 6 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way Vertical type with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 40 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F in repair of MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete all as specified & directed.
S & F for metal clad box suitable for 240 volt 50 Hz AC supply three pin with MCB SP 20 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S & F two pin telephone socket modular type including modular plate and necessary cable connection all as specified.
S & F in repair of exhaust Ventilation fan of 300 mm sweep made of PVC body complete with louver and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to ventilation fan for connection and making good disturbed existing surface including taking down old exhaust fan and deposited to MES Store complete all as per direction of Engr-In -Charge .
S & F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified.
S & F round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
S & F lamp holder, PVC / Poly carbonate type,with cord grip cap suitable for pendent/batten/angle fittings complete all as specified.
S & F in renewal of surface mounted LED 10/9 watts 2 feets LED light fittings, with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in soft/loose soil / floor and making good the disturbed surfaces all as directed and specified
Returning and filling of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm .
Removing excavated soil to a distance not exceeding 50 meter , not exceeding 1.5 meter above the starting point and depositing where directed.
M&L riddle Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
Supply and fixing / laying GI tubing 80mm dia light grade as cable protection in road cuttingetc all as specified and directed by Engr incharge.
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts , grade with stranded aluminium conductor,of size 50 sq. mm 3.5 core complete all as specified and directed by Engr-In-Charge.
M&L in repair of Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
S&F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 kA and Electric connection complete all as specified
S & F in repair of Heritage post top lantern LED IP 65 Rated 230V 20 watts warm white incl all necessary accessories for fixing to pole all as specified and directed.Make: Crompton cat part No. LPTH-20-CDL or its equivalent in Appx 'C'
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core all as specified
Supply laying and testing cable Weather proof flat three core copper cable of size 1.5 Sq.mm including Taking down complete all as specified
Supply and fixing thermoplastic cable junction box IP 66 of size (130x180x77mm) halogen free and weather proof for out door installation( with metric knockouts for cable entry ) Make : HENSEL Cat Part No KF1010B or eqv make in Havells/L&T including taking down old PVC junction boxes complete all as specified and directed.
Taking out UNSV UG cables of any sizes from trenches/walls complete all as specified
S & F in repair of post top lantern LED IP 65 Rated 230V 15 watts warm white incl all necessary accessories for fixing to pole all as specified and directed.Make :-Havells Cat part No CORALMINIPT15WLED757PSYMTOPC or its equivalent in Appx 'C'
K R JOSEPH AND SONS
PRAMOD D
Anaswara Constructions
SOORYA ASSOCIATES
WELTRONENGINEERINGSERVICES
THOMSONS CONSTRUCTIONS
KENZ CONSTRUCTIONS
M/s.Rejoy Constructions
SHAIJAL T M
Yesgee Projects Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .