Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, DHPD, Daporijo.
Office of Executive Engineer, DHPD, Daporijo.
Supplying, providing, laying, fitting and welding of Hydro-Mechanical equipments complete on item rate tender for C/o Bidak MHS (2 x 50 kW) at Redding Camp in Upper Subansiri District of Arunachal Pradesh.
2023_HPDAP_1271_1
NIT No. DD/HPD/W-21/2023-24/06, Dtd. 01/05/2023
Open Tender
Civil Works – Others
Item Rate
60 days
Redding Camp
Please Refer NIT for Details.
4 documents required · 4 mandatory
₹1,500
Executive Engineer, DHPD, Daporijo.
₹1.2 L
Yes
Office of Executive Engineer, DHPD, Daporijo.
29 May 2023
22 May 2023
29 May 2023
22 May 2023
27 May 2023
22 May 2023
22 May 2023 - 22 May 2023
22 May 2023
Amount
HYDRO-MECHANICAL EQUIPMENTS
(Trash Rack for Intake Weir): Fabrication & Supply of Trash Rack of Size 15 m X 1.25 m (fixed type) at Intake Weir conforming to IS 2062:2006, Grade-E250 and as per approved drawing. It includes Welding & fabrication of Steel work (Steel flat of 50 mm X 12 mm with clear spacing of 25 mm in steel angle frame of 50 mm X 50 mm X 6 mm) in single section including fabrication and supplying. Two coat of Zinc rich primer applied and two coat of Coal Tar Epoxy applied over primer.
(Sluice Gate for Intake Chamber): Providing & fixing MS gate with MS channel (65 x 65 mm) frame and shutter with 12 mm thick MS plate fixed & fitting with MS angle (50 x 50 x 6 mm) i/c 32 mm dia. spindle, wheeled handle etc. of size 1.2 m x 0.8 m i/c cutting welding and hoisting etc. complete at site as per approved drawing and applying two coat of Zinc rich primer and two coat of Coal Tar Epoxy applied over primer.
(Flush Pipe for Intake Chamber): Providing & fixing of MS flush pipe (ERW) of 300 mm dia., 6 mm thick & 7 m length conforming to IS:3589.
(Sluice Valve for flushing pipe of Intake Chamber, Desilting Tank & Forebay Tank): (Sluice Valve for flushing pipe of Intake Chamber, Desilting Tank & Forebay Tank): Providing & fixing of Heavy Duty CI (IS 210 FG-200) Sluice Valve of 300 mm dia. as per IS:14856 PD:2000, Thickness 6 mm, Non-Rising Type SS-410 Spindle & Gunmetal Working Parts, Handwheel Operated, Flanged ends drilled to IS 1538 with Matching M.S. Companion (2 nos.) Flanges, Bolt, Nut & Rubber Gasket. Test Pressure: Body-18kg/cm2 Seat-12kg/cm2
(Flush Pipe for Desilting Tank): Providing & fixing of MS flush pipe (ERW) of 300 mm dia., 6 mm thick & 15 m length conforming to IS:3589.
(Forebay Tank Hand Railing): Providing M.S Pipe Hand Rail - 32 mm dia. around Forebay Tank with necessary painting and finishing etc complete.
(Trash Rack for Forebay Tank): Providing & fixing of Trash Rack Size 3.31 m X 1.80 m (fixed type) for bell mouth at Forebay Tank conforming to IS 2062:2006, Grade-E250 and as per approved drawing. It includes Welding & fabrication of Steel work (steel flat of 30 mm X 10 mm) in single section including cutting, hoisting, fixing in position and applying two coat of Zinc rich primer and two coat of Coal Tar Epoxy applied over primer.
(Flush Pipe for Forebay Tank): Providing & fixing of MS flush pipe (ERW) of 300 mm dia., 6 mm thick & 15 m length conforming to IS:3589.
(Penstock Pipe): Manufacturing, supplying and laying of Spirally welded main penstock pipe of 445 mm inner dia., 8 mm thick measuring 260.00 m length plus branch penstock pipe of 343 mm inner dia., 8 mm thick measuring 18.00 m length conforming to IS:11625-(1986) (Reaffirmed 2001): Criteria for Hydraulic Design of Penstocks.
(Penstock Pipe Welding): Fabrication, cutting, joining and e-welding of penstock pipes and flushing pipes by electric plant complete.
(Sluice Valve for Main Penstock Pipe): Manufacturing, supplying & fitting of Heavy Duty CI (IS 210 FG-200) Sluice Valve of 445 mm dia. (ID) as per IS:14856 PD:2000, Thickness 8 mm, Non-Rising Type SS-410 Spindle & Gunmetal Working Parts, Handwheel Operated, Flanged ends drilled to IS 1538 with Matching M.S. Companion (2 nos.) Flanges, Bolt, Nut & Rubber Gasket. Test Pressure: Body-18kg/cm2 Seat-12kg/cm2
(Sluice Valve for Branch Penstock Pipe): Manufacturing, supplying & fitting of Heavy Duty CI (IS 210 FG-200) Sluice Valve of 343 mm dia. (ID) as per IS:14856 PD:2000, Thickness 8 mm, Non-Rising Type SS-410 Spindle & Gunmetal Working Parts, Handwheel Operated, Flanged ends drilled to IS 1538 with Matching M.S. Companion (2 nos.) Flanges, Bolt, Nut & Rubber Gasket. Test Pressure: Body-18kg/cm2 Seat-12kg/cm2
(Expansion Joint for Penstock Pipe): Providing and Fixing Heavy Duty C.I. (IS 210 FG-200) Expansion Joint (445 mm OD) Flanged ends drilled to IS 1538 with Matching M.S. Companion Flanges (2 nos.) Rubber Gasket, Bolt & Nut.
(Air Vent): Providing and fixing of MS Air Vent pipe 50 mm dia. & 6m length.
(Bell Mouth for Penstock Pipe): Manufacturing, supplying & fitting of CI Bell Mouth of 609 mm X 445 mm dia (ID) as per IS:1538 Table-20 duly machined and drilled. Pressure load as per IS 2906 & IS 780 with flange at end for penstock pipe connection.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .