AMC of HT substation equipments like VCB, transformer etc
2024_CSIR_217294_2
ESD/2/42/2024
Open Tender
Electrical Works
Works
365 days
IIP mohkampur Dehradun
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Director IIP
₹7,500
5 May 2025
27 Jan 2025
11 Feb 2025
27 Jan 2025
10 Feb 2025
27 Jan 2025
27 Jan 2025 - 9 Feb 2025
Amount
Schedule maintence serivice and overhauling
Routine AMC visit of 33 KV 20A/100A VCB (vaccum circuit unit) (1 main incomer 100A and 2 outgoing 20A) draw out the breaker unit inspection, overhauling, observation, testing, carbon cleaning by CRC, CTC etc then insultation painting, megger testing minimum 5000V and above as required checking the fault and removing, checking the CT (current transformer) , PT (potential transformer) termianl and Ameter and Voltmeter including of all type consumables
Calibration of HT control proctection relay unit (1 set = 3 unit) which comprise of IDMT relay (inverse definite minimum time) transformer differential relay with help of current injection unit kit and other necessary accossories like current coil, calibaration unit etc. checking and calibration of ameper, voltmeter, power factor meter, KWH meter. Checking inspection of the CT (current transformer) , PT (potential transformer) and termianals etc as required.
ATTENDING EMERGENCY BREAK DOWN OF POWER EQUIPMENT
Attend the emergency complaints visit of 2 X 1000 KVA, 33 KV/ 0.415KV transformer input and output terminal box inspection, observation, testing, insulation painting, carbon cleaning by SRC, CTC then megger testing minimum 5000V and above. Testing the Buchholz relay functioning, LT 3 phase 4 wire bus trunking, conseverter tank, silica gel breather change including of all type consumables.
Attending complaints within the 24 hour under the AMC visit IIP 33 KV substation/ power house and solve the issue regarding 33 KV 20A/100A VCB (vaccum circuit unit) draw out the breaker unit inspection, observation, overhauling, testing, insulation painting, megger testing minimum 5000V and above as required checking the fault and removing, checking the CT (current transformer) , PT (potential transformer) terminal, Ameter and Voltmeter and run the system including the all type of consumables.
Attend the emergency complait of HT control panel relay unit system which has various type protection relay i.e. IDMT (inverse definite minimum time), transformer differential relay which is the part of VCB breaker unit inspection, overhauling, observation, testing, insulation painting, all type consumables, megger testing minimum 5000V and above as required checking the fault and removing, checking the CT (current transformer) , PT (potential transformer) termianl and Ameter and Voltmeter and calibrate the same and run the system.
breakedown visit for 500 KVA 33/0.415KV CSS (make ABB) (compact substation) checking, testing, faulting finding and fault removing of VCB, transformer and power factor controller panel which are in combined unit all to be done by only authorizied service engineer.
Supply and making end termination for 33 KV aluminium cable outdoor type 120 sqmm three phase three wire system heat shrinke HT end termination kit (make Raychem, 3M)
De-hydration/ filtration of the oil of 2 X 01 MVA , transformer by using dehydration machine and BDV value must be achived as per norms.
Attending emergency complaint and servicing of L & T make ACB breaker 1600A 4 pole EDO / MDO and make the system operational with all major overhauling done by authorized service engineer of L & T only etc as required.
Supplying and fixing push bottom cum LED indicator 22.5mm dia with NO+NC block assembly with complete wiring etc as required.
Supplying and fixing type 1+2 AC surge protection device three phase (TP-N) 50KA Imax with remote signaling
Supplying and fixing 24 v Dc indicators (R,Y,B amber and green) 22.5mm dia in exiting 33KV vcb control system etc as required.
Supplying and fixing 220v ac LED indicators 22.5mm dia suitable for LT panel etc as required.
Supplying and fixing of 1200W single phase space heater U finned type suitable for 33KV VCB indoor control and protection panel etc as required.
R.V. ELECTRICAL ENTERPRISES PVT. LTD. (BID ID -816514)
Liv Technology (BID ID -816086)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .