CWE (AF) BAREILLY
HQ Commander Works Engineers AF Military Engineer Services Bareilly 243002
REPAIR/MAINT OF TRANSFORMERS, HT PANEL/GOD/VCB AND HT CABLE AT LKT AND ADM SITE UNDER AGE (I) AF BHOWALI
2024_MES_656942_1
81438/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHOWALI
AS PER NIT
9 documents required · 9 mandatory
₹500
AGE(I) AF BHOWALIl
₹25,400
2 Sept 2024
31 May 2024
29 Jun 2024
31 May 2024
26 Jun 2024
14 Jun 2024
1 Jun 2024 - 13 Jun 2024
Amount
Servicing of HT panel , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components after drawout of VCB trolly and testing for smooth operation manual/ remote after caliberation of relay trough OEM of VCB/Test wing of UPPCL and resetting & generation of testing report by the primary injection set for 11 KV VCB for OC/EF, parameter of relay setting for healthy system, complete all as specified and directed. (Note: Worn out minor parts shall be deemed to included in quoted rate. Major parts shall be measured and paid separately)
Supply only Spring Charging Motor of VCB 110 -230 Volt AC supply for the opening and closing of contacts complete all as required and directed at site complete all as per sample. .
Supply only Indicating lamp LED
Supply only Space heater 100 watt 230 Volt AC supply with thermostat
Supply only Digital multifunction meter 96x96 mm Range 0-300/A Model type 3 phase 4W EN 8400class 1.0, aux supply 110Volt with RS 485 port
Supply only Digital Voltmeter (0 to 12 KV size 96x96 mm class 0.5 , PTR 11000/rt3/110/rt3
Detection of pin point fault in HT cable 11 KV (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed. (Notes-(i) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (ii) Earth work will be measured seperatly. (iii) Cost of transpotation in unit rate is deemed to be included.
Handling, transportation of transformers of any make, type with capacity 200 KVA of any make, model & type including hoisting, taking down from pole (pole mounted) or plinth mounted by any means mechanically pulley/mechanical crane, transportation to workshop for repair/maint. Reinstallation of Transformer in position pole mounted/plinth mounted including disconnecting and connecting all cable, earth lead, clamps and channels etc as per site requirement all as directed. (Note : If any damage to transformer/OH line/cables occur during handling, transportation or during hoisting/lifting, the same will be rectified by the contractor without any extra cost to the department)
M&L for changing of Old / Burnt Copper coil by new EC grade copper coils with complete including insulation material of transformer all as Specified & directed.
Striping out of Insulation of HV/LV windings and reinsulation of Coil with insulating material of transformer for any type and capacity of transformers complete all as specified and directed.
Labour only for opening of top cover and allied parts of transformer of cap up to 200 KVA lifting of Core for repair, preheating charges for copper coils, assembly of core coil assy including assembly of copper coils, tapping connections, insulation on Tap leads with insulation paper, star connection by new EC grade copper on HV & LV side ., Baking charges for transformer job for each proper IR value in vacuum Chamber (Auto Clave), refitting of HV / LV bushing and transformer accessories with top cover, M&L for painting of transformer tank having hot oil resistant paint inside all as specified & directed.
M&L transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: Oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Dyhydration/filteration of transformer oil at site by means of centrifuging machine in order to improove dielectric strength of oil as per IS-355, break down voltage should not be less than 50 KV complete all as specified & directed.
Supply and fix LV porcelain bushing of transformer 1.1 KV/250 Amps with metal parts brass as per IS 3347 part-III and 4 Nos hexagonal nuts, complete all as specified and directed.
Supply and fix LV porcelain bushing of transformer 1.1 KV/400 Amps with metal parts brass as per IS 3347 part-III and 4 Nos hexagonal nuts, complete all as specified and directed.
Supply and fix HV porcelain bushing of transformer 12KV /250 Amp with metal parts brass as per IS 3347 Part-III and IS 2009, complete all as specified and directed.
M&L for hammer tone spray painting of transformer 11 KV/433 volts, Indoor/Outdoor type transformer 63 KVA to 125 KVA capacity, including cleaning, scraping of exposed surfaces with shade as approved including writing MES number and machine number with black paint, letters 15mm wide and 50mm height complete all as specified and directed.
M&L for hammer tone spray painting of transformer 11 KV/433 volts, Indoor/Outdoor type transformer 125 KVA to 250 KVA capacity, including cleaning, scraping of exposed surfaces with shade as approved including writing MES number and machine number with black paint, letters 15mm wide and 50mm height complete all as specified and directed.
Supply and Replacement of silica gel breather assembly for capacity 63 KVA to 250 KVA capacity transformer, complete all as specified & directed.
Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded , galvanised steel strip or wire armoured,electric power cables( heavy duty ) with aluminium conductor of size 95 sqmm, 3 core, 11000 volts grade, laid in trenches/poles/walls all as specified and as directed.
M&L cable jointing kit for 11 KV (E) grade cable for indoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
M&L cable jointing kit for 11 KV (E) grade cable for outdoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
M&L cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
Material and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 20x3mm size (upto 7.5 metre from ground electrode) by means of copper/brass bolts, nuts, check nuts and washers, connected to earth test terminal block and testing on completion with and including 40mm bore light grade GI protection pipe for strip upto plinth protection, PCC pit in mix 1:3:6 type C1, with RCC 1:2:4 type B-1, 40 mm thick cover, reinforced with 6 mm dia MS bars spacing @ 100mm C/C both ways with lifting hook made out of 10 mm dia round bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as shown in electrical plate No.3 of MES Schedule Part-I (2009) and directed.
Cleaning of area of 11 KV main receiving station and removing the green grass patches /bushes/small plants/herbs from the area with suitable T&P and covering the area with & including supply of pebbles and dressing after sparying the complete area with suitable herbicide to stop the growth of weeds and grass as directed by Engr-in-charge. ( Note: (a) Complete Job will be done only after taking proper shut down of 11 KV HT Line. Shut Down will provided by the Dept. with Liasion of SED (b) Cleaning of area will be done once in a three months.
Supply and fixing dial type temperature gauge 110mm dia temperature range 0-100 degree C in repair all as directed by Engr-in-Charge.
Supply and fixing lightning arrestor of 11 KV metal oxide (Gap less type) heavy duty, self supporting station class having nominal discharge current 65 KA (peak), class II , insualation level 28/75KV suitable for 11 KV supply including necessary connections with complete all as specified and directed. Make : Raychem RPG , Oblum ,CG
Taking out unserviceable/faulty cable of any size/type for repair/replacement from pole/wall/cable duct/underground trench etc for reuse or depositing to MES store yard complete all as specified and as directed. (Note:-Excavation and earth work shall be measured and paid separately)
Supply, laying, jointing and testing XLPE insulated, screened, armoured electric cables with aluminium conductor of size 50 sqmm 3.5 core, 1100 volts grade, laid in trenches/poles/walls all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated, screened, armoured electric cables with aluminium conductor of size 35 sqmm 3.5 core, 1100 volts grade, laid in trenches/poles/walls all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated, screened, armoured electric cables with aluminium conductor of size 35 sqmm 4 core, 1100 volts grade, laid in trenches/poles/walls all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated, screened, armoured electric cables with aluminium conductor of size 25 sqmm 4 core, 1100 volts grade, laid in trenches/poles/walls all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of pole or cable trenches etc and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
Removing excavated materials exc. 250M but not exc. 500M and depositing where directed all as specified and directed by the Engineer-in-Charge.
Material and labour for laying of sub class ‘B’ bricks, common burnt clay building bricks,designation 75 complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand all as specified and as directed by the Engineer-in-Charge. (Note- Punned thickness 18 cm will be measured & paid)
Material and labour for galvanized iron tubing 80 mm bore (light grade) with all fittings for protection of cables, laid in trenches / fixed to wall or pole complete including providing fixing clamps, bolts and nuts of suitable size all as specified & directed.
Material and labour for galvanized iron tubing 50 mm bore (light grade) with all fittings for protection of cables, laid in trenches / fixed to wall or pole complete including providing fixing clamps, bolts and nuts of suitable size all as specified & directed.
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 12 insulators of rating upto 200 Amps all as specified & directed.
VINYAK TRADERS
AJA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .