Ex Engineer ED-Ganderbal
Office of the Ex Engineer ED-Ganderbal
Installation of dedicated essential feeder along with Creation of Electric Substation for WSS Regional Parihaspora.
2024_PDD_253838_1
EDG/V/041 OF 2024-25
Open Tender
Electrical Works
Lump-sum
25 days
GANDERBAL
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
Yes
Ex Engineer ED-Ganderbal
₹1.8 L
Yes
21 Oct 2024
22 Jul 2024
13 Aug 2024
22 Jul 2024
12 Aug 2024
22 Jul 2024
22 Jul 2024 - 23 Jul 2024
Supply, Installation, Testing and Commissioning of 630 KVA 11/0.433KV, 3-phase Distribution transformers with Bimetallic Terminal Connectors Energy level-2 Copper Wound and with LV Cable Box having detachableAluminium Gland Plate
Supply, Installation, Testing and Commissioning of 400 KVA 11/0.433KV, 3-phase Distribution transformers with Bimetallic Terminal Connectors Energy level-2 Copper Wound and with LV Cable Box having detachableAluminium Gland Plate
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 33]
Providing & fixing of 3 No. Earthing of substation --Excavation of earth pit of dia 650mm & depth 3000mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and fixing of GI Channel cross-arm (100 x 50x6mm) / 75x40x40 x6mm including back clamps of 50X8 mm for fixing Cross arm and pole top bracket (including Transfortmer Pad/GI Channel Bedding) .
Supply, Installation, Testing and Commissioning of 400 MM Sq (3-CKT) for 630 KVA Single Phase cable 1.1KV Grade, XLPE insulated Strandard Conductor
Supply, Installation, Testing and Commissioning of 300 MM Sq (3-CKT) for 400 KVA Single Phase cable 1.1KV Grade, XLPE insulated Strandard Conductor
Supply, Installation, Testing and Commissioning of GI Pipe of 150mm Dia 2 Mtr long for Pole Butts
Supply, Installation, Testing and Commissioning of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
Supply, Installation, Testing and Commissioning of 11 kV, G.O AB Switch , 3-phase, 200A
Supply, Installation, Testing and Commissioning of 11 kV Horn, Gap Fuse 3-phase 100A
Supply, Installation, Testing and Commissioning of LT Fuse Set
Providing & fixing of LT Distribution Box for 630 kVA DTR with 1000 Amp MCCB 3P 36 kA for incomer & 250 Amp MCCB 3P 25 kA 2 No.s and 200 Amp MCCB 3P 25 kA 3No.s for Outgoing Circuits
Providing & fixing of LT Distribution Box for 400 kVA DTR with 630 AMP MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 4 No.s for Outgoing Circuits
Supply, Installation, Testing and Commissioning of Prodigy Meter for Energy Metering
Supply, Installation, Testing and Commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, Installation, Testing and Commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing and painting of 9 Mtr ST poles with two coats of red oxide and two coats of aluminium paint
Providing and laying of Cement Bottoming in 1:2:4 mix 0.5cum per pole for 9mtr Poles
Providing & fixing of Anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
Providing & fixing of GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection
Supply, Installation, Testing and Commissioning of Baby Insulator with strip Rings
Supply, Installation, Testing and Commissioning of Galvanized Nuts and Bolts of sizes.
Providing & fixing of GI barbed wire for Anti Climbing Device
Providing & fixing of Wedge Connectors/ PG Clamps
Supply, Installation, Testing and Commissioning of Sundry items like Aluminum Lugs, Jumpers , Binding tape
Providing & fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No..), anchor plate (200x 200 x 6 mm), nut-bolts, 2 No. turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension Points as per REC Strandard
Providing & fixing of Danger Plates with Clam ps with Writing in English and Regional Language
Supply, Installation, Testing and Commissioning of 70 mm Sq AB (HT Cable (3x70+1x95 mm Sq)XPLE) 11KV 3 Core + Earth
Supply, Installation, Testing and Commissioning of Suspension Clamps/ Eye Hooks
Supply, Installation, Testing and Commissioning of Heat Shrinkable Outddor Cable Kit
Supply, Installation, Testing and Commissioning of Mid Spain Straight through jointing Kit for 11KV ABC
Marib Constructions
M/S WATT ELECTRICAL CONTRACTS
Blue sky power developers pvt. ltd
HARMUKH INFRASTRUCTURE PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .