| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹1.5 L (4.39%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹36.3 L+₹1.8 L (5.30%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹38.3 L+₹3.9 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹45.0 L+₹10.6 L (30.7%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Nov 2020, 6:00 pmClosed
GE I DM
Naval Dockyard Visakhapatnam 530014
REPLACEMENT OF DEFECTIVE SPARES OF 11 KV VCBs, PANELS, BUS BAR ETC CALIBRATION OF RELAYS AND OTHER ALLIED WORKS AT MAIN RECEIVING SUB STATION AND NEAR BY SUB STATIONS INCLUDING OTHER MISC WORKS AT ND V
2020_MES_388181_1
SSGE/8334/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhpatnam
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I DM
₹98,000
Yes
4 May 2021
20 Oct 2020
23 Nov 2020
20 Oct 2020
17 Nov 2020
3 Nov 2020
Amount
M&L for maintenance of 11KV CT chamber by disconneting all 3 phase cable connections, extended busbars and from VCB Bus and taking out from panel mounted position, testing for proper functioning, body leakage, checking & cleaning / decarbonising of all contact points of CT, epoxy body and Busbars, complete CT chamber using hot blower and CTC solution, applying backtol (Red) solution to the CT body and refixing the same CT to original position, re-connection of all existing cables, extended busbars, testing complete all as specified and directed. Note:- CT required new shall be measured as supply only.
Maintenance, servicing, cleaning of Busbur chamber of each VCB including connecting busbar from CT to Busbar, spout, support insulator, opening of covers, using CTC and clean cloth and hot air blower/vaccum cleaner, checking for any loose contact, tightening of all nuts & bolts, refixing all covers, replacement of defective bus spout complete all as specified and directed Note :- Bus spout required new shall be measured as supply only.
M&L for setting of 3 phase over current + earth fault numerical relays by primary injection of current to CTs with suitable equipment for over current & earth fault with high set and low set including checking of all other parameters of relays for proper tripping order after disconection of incoming or out going HT XLPE cable connection from VCB CTs and reconnection of cable ends at existing terminals after completion of relay setting complete all as specified and directed. (Note: (a) Relay setting shall be made considering corresponding values of upstream and down stream VCB relays and recorded maximum demand of VCB. Any further adjustment of values as many times require shall be carried out within the quoted rate. (b) Recovery shall be made double the quoted rate if VCB fails to trip in indicated fault and if group tripping recorded)
Supply only Resin Cast CT dual core, CT racio- 100/50/5A-5A For 800A to 2500A Schneider make 11 KV VCB. Make-Kappa/Esun/Pragati
Supply only Resin Cast CT dual core, CT racio- 800-400/5A-5A For 800A to 2500A Schneider make 11 KV VCB. Make-Kappa/Esun/Pragati
Supply only Resin Cast CT dual core, CT racio- 600/300/5A-5A For 800A to 2500A Schneider make 11 KV VCB. Make-Kappa/Esun/Pragati
M&L for rectification of fault of control circuit of 11 KV VCB by checking, repair of close / trip / spring charging circuit replacement of defective wiring with FRLSH multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed
M&L for maintenence/servicing of PT unit 11Kv / 110V by disconneting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of busbar connections, resin cast PTs using hot blower, CTC solution, applying backtol (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Maintenance, servicing, cleaning of vacuum circuit breaker unit of 11 KV VCB panel of capacity 400 Amps to 2500 Amps, taking out from panel, cleaning of all parts with CTC and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, complete all as specified and directed. (Note: Replacement of defective parts of the VCB shall be measured and paid separately)
M&L for rectification of fault of DC 110V circuit of 11 KV VCB by checking, repair from battery charger to VCB and and internal distribution to other components / system and replacement of defective wiring with FRLSH multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete LED indicator all as specified and directed
Supply and fix including dismantling taking out unserviceable Dashpot Assembly for 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MHU39S3828900FN
M&L for rectification of fault of electrical circuit of 11 KV VCB by checking, repair from CT/PT and programming of multifunctional meters and replacement of defective wiring with FRLSH multistranded PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed
Supply and fixing Schneider Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 to Schneider make 11KV VCB including necessary connection testing complete including dismantling taking down unserviceable one complete all as specified and directed.
Supply and fixing Schneider High speed trip relay, type-VAJH, 110V to Schneider make 11KV VCB including necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and directed.
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and directed. Make- Schneider, Part No- ECO39SN134900FN
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one all as specified and directed. Make- Schneider, Part No- ECO39SN134100FN
Supply and fix incl dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 2500 Amps all as specified and directed. Make-Schneider only. Part No-VSLVG4002-01
Supply and fix including dismantling taking out unserviceable Breaker Nylon Wheel, For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MVIA00054-01
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MVIJOO157-02
Material & Labour for dismantling taking out burnt spring charging Universal motor with gear box 220V AC from 800A to 2500A Schneider make 11 KV VCB, transportation to civil workshop, rewinding complete motor with required size of super enamelled copper wire, heating, vernishing and transportation back to site, refixing to original position in VCB, connections, testing complete all as specified and directed..
Supply and fix including dismantling taking out unserviceable Release Lever (Nylon ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only , Part No- MVIJ00010-01
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIJ000980-1
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- ERC-A-A00DC-001
Supply and fix space heater, 230V, 100 watt inside cable chamber including necessary connection, testing complete all as specified and directed. Make- Schneider, Part No-EHT-A-AA 000-001
Supply and fix including dismantling taking out unserviceable thermostat for space heater For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- ETH-E-B000-001
Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- EHF-A-EV 000-001
Supply and fix including dismantling taking out unserviceable Control Circuit HRC Fuse : 2 A , 4 A , 6 A , 1 0A complete all as specified and directed. Make- L&T, Type-HG, size-F1 Cat No- ST-30725 to ST-30728
Supply and fix including dismantling taking out unserviceable bakelite HRC Fuse holder : 2 A , 4 A , 6 A ,1 0A complete all as specified and directed. Make- L&T, Type-HD 20H , Fuse type-F1 Cat No- ST-30772
Supply and fix including dismantling taking out unserviceable Service /Test Position Limit Switch 1NO+1NC For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- ESW-B-AAA00-001
S&F multifunctional meter with LED disply, accuracy class-1, e-nevigator, including dismantling taking down unserviceable one and connection, programming, testing complete all as specified and directed. Make- Elmeasure, Model- EN-8400
Supply and fix including dismantling taking out unserviceable Isolating Contact For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIK00190-01
Supply and fix including dismantling taking out unserviceable Isolating Contact For 2000A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIK00190-02
Supply and fix single (Red-Blue) phase busbar spout suitable for 800 Amps to 1250 Amps VCB make Schneider only Model No MEP-39-32185 complete all as specified and directed.
Supply and fix single (Y) phase busbar suitable spout for 800 Amps to 1250 Amps VCB make Schneider only Model No MEP-39-32186 complete all as specified and directed.
Supply and fix single (Red-Blue) phase busbar spout suitable for 1600 Amps to 2000 Amps VCB make Schneider only Model No MEP-39-A0051301 complete all as specified and directed
Supply and fix single (Y) phase busbar spout suitable for 1600 Amps to 2000 Amps VCB make Schneider only Model No MEP-39-A0051401 complete all as specified and directed.
Supply and fix Dirve Beam suitable for 11 KV VCB 800 to 2000 Amps make Schneider only Model No MSM3950118600FN complete all as specified and directed.
Supply and fix Epoxy Body suitable for 11 KV VCB up to 1250 Amps make Schneider only Model No MEP3953022000FN-22 complete all as specified and directed.
Supply and fix Dive Rod assembly with contact block VG2 suitablke for 11 KV VCB up to 1250 Amps make Schneider only Model No SPR395ASS0014FN complete all as specified and directed.
Supply and fix Dive Rod assembly with contact block VG4 suitablke for 11 KV VCB up to 1250 Amps make Schneider only Model No SPR395ASS0011FN complete all as specified and directed.
Supply and fix CT Spout suitable for VCB 800 to 2500 Amps 25 Ka chamber insulating bus support epoxy insulator of dia 95mm and 125mm length complete all as specified and directed
aswitha engineering works
koneru enterprises
SUPREET CONSTRUCTIONS
SRIESWARI ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .