AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR /REPLACEMENT OF INTERNAL ELECTRIC WIRING FITTING, FIXTURE AND GEYSER TO MD ACCN AT DGRE RDC MANALI
2022_MES_543164_2
AGE(I)/MNL-39/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
DGRE MANALI
As per NIT and Tender Documents
5 documents required · 5 mandatory
₹300
AGE I R AND D MANALI
₹9,920
Yes
7 Jan 2023
4 Oct 2022
24 Oct 2022
4 Oct 2022
22 Oct 2022
10 Oct 2022
Amount
Taking down copper /aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conitions separately) and making good distrubed surfaces of walls, floors etc complete all as per specified and as directed by Engineer-in-Charge.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface complete all as per specified and as directed by Engineer-in-Charge. MAKE OF CABLE - Standard /PLAZA /HAVELLS & MAKE OF PVC CASING /CAPING-PRICISION/PRESSFIT /MODI. Note:- Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch complete all as per specified and as directed by Engineer-in-Charge.
(b) One ceiling /exhaust fan point controlled by one switch and regulator complete all as per specified and as directed by Engineer-in-Charge.
(c) One 3 pin 5 amp socket out point on the same board with other switches complete all as per specified and as directed by Engineer-in-Charge.
(d) One3 pin 5 amps socket out let point on independent board complete all as per specified and as directed by Engineer-in-Charge.
All as per Srl item No. 2.00 above but for one socket outlet 15 amp on independent board with 2.5 Sqmm cable and 1.5 Sqmm earth wire.
S&F switch piano flush type single pole one way 5 amps complete all as per specified and as directed by Engineer-in-Charge.
S&F modular switch 2 way 6A, 1 module complete all as per specified and as directed by Engineer-in-Charge.
S&F Socket out let 2 in one, 5/3 pin 5Amp complete all as per specified and as directed by Engineer-in-Charge.
S&F switch socket combination 5 Amps 5 pin flush type complete all as per specified and as directed by Engineer-in-Charge.
S&F switch socket Independent 5 Amps 5 pin flush type complete all as per specified and as directed by Engineer-in-Charge.
S&F switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal complete all as per specified and as directed by Engineer-in-Charge.
S&F Switch socket Independent 5 in 1, 5 pin 5/15 Amps flush type universal complete all as per specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite 65x50 mm three terminal complete all as per specified and as directed by Engineer-in-Charge.
S&F lamp holder, PVC /Polycarbonate type insulated body with back plate for angle holder suitable for fixing of LED Bulbs of any wattage 230 Volts complete all as per specified and as directed by Engineer-in-Charge. Notes for Item ser No. 03 to 09 Make: Anchor/Havells
M&L for modular (Gang Box) switch socket outlet 3 pin 5 amp' flush type complete all as per specified and as directed by Engineer-in-Charge.
M&L for modular (Gang Box) switch socket outlet 3 pin, 15 amp, flush type complete all as per specified and as directed by Engineer-in-Charge.
S&F LED bulb /lamp of 7/9 Watts Cool Daylight complete all as per specified and as directed by Engineer-in-Charge. Make: Havells Cat No: LHLDEUHEML8R009
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as per specified and as directed by Engineer-in-Charge. MAKE: HAVELLS as per cat No LHEXBLP7UN1W018
S&F 22 Watt E-Lite LED gREEN Decorative ultra slim round profile LED lighting fiting/ fixture with co extruded polycarbonate body, environmental friendly, energy efficient complete all as per specified and as directed by Engineer-in-Charge. Make Havells other then Eqvt Bajaj CG
S&F of tube light of 36 Watt T8 Maxoline FTL 6000K cap base G5 complete all as per specified and as directed by Engineer-in-Charge. Make: Havells other then Eqvt Bajaj CG
S&F of tube light of 28 Watt T5 FTL 6500K complete all as per specified and as directed by Engineer-in-Charge. Make: Havells other then Eqvt Bajaj CG
S&F in replacement copper ballast /choke of 36/40W for FTL fittings complete all as per specified and as directed by Engineer-in-Charge. Make: Crompton cat No SFBN4340 or equivalent of Havells/Bajaj
S&F in replacement of starter 18/20/36/40W for FTL fittings complete all as per specified and as directed by Engineer-in-Charge. Make: Crompton Cat No FSU or equivalent of Havells/Bajaj
S&F in replacement of slim /sleek electronic ballast suitable for 1x36 watt FTL 240 volt 50Hz complete all as per specified and as directed by Engineer-in-Charge. Make: Philips/Havells
Taking down old and UNSV DBs SPN/TPN complete with MCB TPN/SPN/SP complete all as per specified and as directed by Engineer-in-Charge.
S&F in Fixing MCB DB 8 Way Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces complete all as per specified and as directed by Engineer-in-Charge. Make : Havells/lEGRAND/SSK
All as per Srl item No. 24.00 above but 12 Way. Make: Havells/lEGRAND/SSK
All as per Srl item No. 24.00 above but 16 Way. Make: Havells/lEGRAND/SSK
S&F MCB, DP 415 Volts, 40-63 Amps complete all as per specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Philips
S&F MCB SPN, 240 Volts, 32-40 Amps complete all as per specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Philips
S&F MCB, TPN, 415 Volts, 63 Amps complete all as per specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Philips
S&F MCB singal pole 240 Volts, 6 to 32 Amps complete all as per specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Philips
S&F in replacment of copper wire PVC insulated and unsheathed FR/FRLS flexible of size 1.5 Sqmm single core complete of appropriate length complete all as per specified and as directed by Engineer-in-Charge. Make: Havells Basicd Code: WHFFDN…A11X5
All as per Srl item No. 31.00 above but 2.5 Sqmm. Make: Havells Basicd Code: WHFFDN…A12X5/Polycab or equivalent.
Standard engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .