Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹48.0 L+₹4.2 L (9.47%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected for F bid opening. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Dec 2023, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
PROVN OF TILING IN LIEU OF PCC FLOORS IN ALL SMQS OF DOMESTIC AREA AT AF STATION DWARKA, WATER PUMP AT SARMAT RANGE AND CERTAIN WORK SERVICES AT SMC AND SWIMMING POOL AT AF STATION JAMNAGAR UNDER GE (AF) JAMNAGAR NO.2
2023_MES_628234_1
8476/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹90,000
Yes
16 Jan 2024
14 Nov 2023
13 Dec 2023
14 Nov 2023
12 Dec 2023
28 Nov 2023
Amount
Demolition of brick work / stone work / PCC block masonry built in cement mortar complete all as specified and directed.
M & L for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:4 type C1 (1:3:6) 20mm graded aggreagate, complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finish the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in two layers 10mm thick in CM 1:6 and 5mm thick in CM 1:4 on stone / PCC block masonry wall surface, including mixing liquid water proofing compound in second layer only as per manufacturers instructions, finished the surface even & smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid separately
Supply only Liquid water proofing compound complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting (putty) complete all as specified and directed.
M&L for two coats of Cement Base Paint over a coat of alkali resistant primer on newly plastered surfaces of walls including preperation of new surfaces complete all as specified and directed.
M & L for preparation of old distempered / decorated surfaces of walls incl brooming down, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion complete all as specified and directed.
M & L for preparation of old distempered / decorated surfaces of ceilings incl brooming down, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion complete all as specified and directed.
M & L for preparation of old distempered / decorated surfaces of walls incl brooming down, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of distemper oil emulsion complete all as specified and directed.
M&L for complete removal of existing treatement, applying two coat of distemper oil emulsion over and including 3 mm thick wall care putty on wall complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and providing two coat of cement base paint complete all as specified and directed.
Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) and removing the same to a distance of 1.5 km including loading and dumping / levelling at the destination complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in floor/ hard standing etc finishing the surface even and smooth without using extra cement and spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth potection including finished the surface even and smooth without using of extra complete all as specified and directed.
Dismantling of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debris to outside MOD land complete all as specified and directed.
M & L for 25 mm thick cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in levelling course complete all as specified and directed.
M&L for non - skid joint free coloured ceramic tiles (1st quality) not less than 7 to 8 mm thick of size exc 0.06 sqm but n exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for non - skid joint free coloured Ceramic tiles (1st quality) not less than 7 to 8 mm thick tiles of size exc 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for non - skid joint free coloured Ceramic tiles (1st quality) not less than 7 to 8 mm thick tiles of size exc 0.18 sqm but n exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 450x300x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat of mortar in CM 1:4 for laying wall tiles finishes complete all as specified and directed.
Dismantling of kota stone slabs and granite tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc complete all as specified and directed.
M&L for Granite work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and directed.
M & L granite (of any type) work 18 to 20mm (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for machine cut & machine polished kota stone slab 18 to 20 mm thick as in kitchen platform, treads of steps laid over and including 15 mm thick screed bed in CM 1:6, jointed with grey cement slurry mixed with colour pigment to match the shade of the slab, rubbing and polishing complete all as specified and directed.
M&L for 18-20mm thick machine cut kota stone slab in riser of steps, skirting,dado and pillar laid over cement mortar in 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for rounding to edges of Granite / Kota stone slabs edge, such as in steps cooking platform, and other similar situation.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) exc 1.5 Sqm and n. exc 4.0 sqm area of each complete all as specified and directed.
S & F in repairs 20 mm dia Curtain rails, mild steel, chromium plated with fixing brackets / concealed brackets & holders, stops, rollers etc. decorative type fitting complete all as specified and directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debris to a distance exc 1.5 Km but n. exc 2 Km. complete all as specified and directed.
S&F in repairs Door closer hydraulically regulated, designation No.2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or rivetted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work quality of steel conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws, complete all as specified and directed.
S & F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
Grinding, polishing and rounding off edges of glassexc 4mm thick but n exc 8mm thick and circular cutting on glass of any type complete all as specified and directed.
M & L for 12 mm prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified and directed.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall be of size 101.60 x 44.75 x 2.4 mm (Section No 14021) (b) Vertical Members of shutter Section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370).
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) three track window (two shutters glazed) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in Member for wire gauge Section shall be 18.00 x 25.00 x 1.35 (Section No 20791). position, concelled type lock for all two shutter, PVC roller etc all as specified below, including taking down old window complete all as specified and directed. (a) Frame (top & side) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 (Section No 20738) (d) Shutter Interlock Section shall be of size 18.00 x 40.00 x 1.45 (Section No 20737) (e) Bottom Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 (Section No 20736) Note:- Section No given above are of make Jidal, Contractor may use similar section of other make mention in Appx B.
Demolition of cement concrete of any description and in position not otherwise specifically provided for and removing the debris/rubbish outside of MOD land complete all as specified and directed.
M&L for light shade colour vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item No.45 but in skirting & dado over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with neat cement slurry, laid over and including 15 mm thick cement screed bed in CM 1:6 complete all as specified and directed.
Excavating in trenches in soft/loose soil n.exc 1.5m wide and n.exc 1.5m in depth for foundation, laying pipes, cables etc n.exc 10Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M & L for Pre-cast cement concrete block masonry type C1 1:3:6 (using 20mm graded stone aggreagate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate ) as in coping, benching and like including weathering, slightly round or chamfered angles and throating as directed and including necessary use and waste of formwork complete all as specified and directed.
M &L Providing precast cement, but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces type B1 1:2:4 (using 20 mm graded stone aggregate) set in cement mortar 1:4 complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on brick or stone walls to be finished even and smooth (without using extra lime or cement) complete all as specified and directed .
S & F steel work in tubular trusses including special shaped washer etc.using ERW or induction butt welded tubes conforming to I.S.1161:1998 grade St.-240 complete all as specified and directed.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel or iron surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for 100 mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches/pole foundation and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning 18cm before and 5 cm after laying of under ground electric cable, including punning down of sand in layer complete all as specified and directed. Note: For measurement purpose punned thickness of sand only will be considered.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
M & L for concealed point wiring with PVC insulated and unsheathed multistranded Fire retardant low smoke (FRLS) copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawn through heavy duty rigid non metalic PVC conduit not less 20mm dia including all accessories like bend, tees, junction boxes etc with all accessories suitable for modular type fitment including making arrangement for fixing of modular flush boxes of suitable size complete along with copper earth wire PVC insulated & unsheated multitranded (FRLS) copper conductor cable of size 1.5sqmm as continuous earth wire connected to common earth and earth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing / colour washing to match with the existing surface complete all as specified and directed.
(a) One Light point /Fan point controlled by one switch
(b) One 3 pin socket outlet 5Amps on the same board with other switches
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board
M & L for concealed Point wiring with PVC insulated and unsheathed multistranded Fire retardant low smoke (FRLS) copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawn through heavy duty rigid non metalic PVC conduit not less 20mm dia including all accessories like bend, tees, junction boxes etc with all accessories suitable for modular type fitment including making arrangement for fixing of modular flush boxes of suitable size complete along with copper earth wire PVC insulated & unsheated multitranded (FRLS) copper conductor cable of size 2.5sqmm as continuous earth wire connected to common earth and earth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
All as per item No 66 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continuous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M&L for ceiling rose, 2 to 3 terminal PVC / polycarbonate, isolated body type suitable for AC 230volts complete all as specified and directed.
M & L for module cover plate with frame as per site requirement for following module
(a) 1 module
(b) 2 module
(c) 3 module
(d) 4 module
(e) 6 module
(f) 8 module
M & L for Modular metal Flush box as per site requirement.
(a) 1/2 module
(b) 3 module
(c) 4 module
(d) 6/8 module
M & L for modular switch 1 way 6 Amp 1 module, complete all as specified and directed.
M & L for Modular Socket 6A 2/3 Pin universal 2 module, complete all as specified and directed.
M & L for Modular Switch 1 way 16/20 Amp 1 module, complete all as specified and directed.
M &L for Modular Socket 16A / 6A 2/3 Pin combined 2 module, complete all as specified and directed.
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, complete all as specified and directed.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed.
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed.
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management,reversible door for for IP 43, single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed.
M&L for MCB single pole & neutral 240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed.
M&L for MCB single pole, 5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
Supply & fix Air Circulator wall fans heavy duty 230 volts single phase oscillating 450 mm, 1400 RPM sweep suitable for wall mounting including taking down old unsv, all as per site requirement complete all as specified and directed.
Supply and fix horizontal submersible pump electric driven 415V, 3 phases suitable open well type supply and install complete of 3 HP inclusive inlet outlet dia 65 x 50 mm at AF station Sarmat Range complete all as specified and directed.
DWARKADHISH ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .