Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹27.0 L+₹9,757 (0.36%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹27.3 L+₹39,643.50 (1.47%)Rejected-AOC A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹27.5 L+₹59,513 (2.21%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹27.9 L+₹1.0 L (3.80%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹93,200
Closing Date
10 Oct 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIR TO REWIRING TO BLDG NOS P 76 A AND B P 78 TO P 84 P 149 P 151 TO P 153 AND P 157 06 AT MIL STN GANDHINAGAR
2024_MES_675585_1
GE(A)/GNR/TOKEN/69 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹93,200
Yes
2 Jan 2025
20 Sept 2024
17 Oct 2024
20 Sept 2024
10 Oct 2024
4 Oct 2024
20 Sept 2024 - 2 Oct 2024
Amount
Taking down carefully u/s copper /aluminium point wiring (light, fan ,socket or power point ) complete,after removing wall panelling without any damage, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody after rewiring refixing of wall panelling. and making good disribution surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-charge.
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawn in PVC conduit concealed wiring and including medium grade PVC conduit 25mm in sise, fire resistant, ISI Marked including with its fitting asd fixtures such as tees, bends, elbows, junction boxes, etc. including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire including pressed steel sunken concealed terminal boxes with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan/exhaust point controlled by one switch
(b) One light point controlled by two way switch
(c) One multi purpose socket 5 Amps on the same board.
(d) One multi purpose socket 5 Amps in Independent board.
M&L for wiring with and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including medium grade, rigid non metallic, PVC concealed conduit of 25mm bore and including cutting chases for conduits and sunken for boxes, to making good disturbed surface including chases for pvc casing caping /conduit as pre site requirement its accessories & including with multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, green colour, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating with provision of sunken concealed terminal boxes complete all as specified and directed.
M&L for poing wiring with and including multistranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 25mm in size, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for AC/Geyser point on independent board complete all as specified and directed.
S&F in replacement lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F in replacement, switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F in replacement, socket outlet multipurpose, 3 pin, 5 &15 Amps flush type complete all as specified and directed.
S&F in replacement, socket outlet 2 in1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F in reolacement, switch piano flush button single pole, one way 15 Amps complete all as specified and directed.
S&F in repair switch piano, flush button single pole, two way 5 Amps complete all as specified and directed.
S&F, in repair, MCCB, 3 Pole, 16 KA, 63 Amps, 415 Volts complete all as specified and directed.
S&F, in repair, sheet metal enclosures, single pole & neutral with a two pin & earth plug and socket complete with one single pole, MCB of 20 Amps, 10 KA, 240 volts complete all as specified and directed.
Supply & fix ceiling rose, PVC/ polycarbonate,isolated body three terminals, complete all as specified and as directed.
Taking down existing ceiling fan and keeping in safe custody and re-installation the same after completion of work complete all as specified and directed.
S&F, in repair, decorative wall mounting light, brushed nickel finished with acrylic diffuser suitable for 9 watt LED lamp B22 base toughned glass with secondary optics including taking out old unsv fitting of any type complete all as specified and directed.
Supply & Fix in repair LED type street light fittings, IP-66, 35W, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics including taking out old unsv fitting of any type complete all as specified and directed.
S&F, in repair, LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC Surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed.
M & L in replacement sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC conduit ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
M & L in replacement sub-main wiring with 2 single core 6 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC Concealed conduit ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 6.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
M&L for Sub main wiring complete with 4 single core, 6 sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS copper multi stranded conductor drawn in and including PVC conduit not less than 25mm size including drawing 2 run of PVC insulated, unsheathed, 100 Volts grade, FRLS, copper conductor multi stranded, 6 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note : (i). 4 runs of main conductor and one run of earth conductor and one run of PVC conduit shall be measured as one length.
M&L for Sub main wiring complete with 4 single core, 6 sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS copper multi stranded conductor drawn in and including PVC conduit not less than 25mm size including drawing 2 run of PVC insulated, unsheathed, 100 Volts grade, FRLS, copper conductor multi stranded, 6 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note : (i). 4 runs of main conductor and one run of earth conductor and one run of PVC conduit shall be measured as one length.
S&F, in repair, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F, in repair, Distribution Board SPN 4 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S&F, in repair, of Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S&F, in repair, Distribution Board SPN 12 way, 240 volts, 200 A factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S&F, in repair, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix LED light fitting 1 x 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
S&F Distribution Board Power Line, VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 3 pole MCCB 63 Amps rating, 16KA breaking capacity for incoming supply and provision of MCBs 6 to 32 A for out going supply complete all as specified and directed.
Taking down carefully tube light fitting and refixing after proper cleaning and making good disturbed surfaces of walls etc. complete all as specified and directed.
S&F, in repair, 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
S&F, in repair, 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.
Cutting chases, pinning in, making good to facings where required of brick/stone wall and painting in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
M/L for Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified or directed and testing
S&F, in repair, for ceiling fan regulators, electronic step type, AC, 230 Volts complete all as specified and directed.
S&F, junction boxes dia of 25mm (1 to 4 way) with cover plates and accessories complete all as specified and directed.
ARTI CONSTRUCTION (BID ID -3135362)
JYOT ENTERPRIES (BID ID -3135735)
Electricals India (BID ID -3135163)
ALBA AC AND REF SERVICES (BID ID -3128017)
MAA PUNAGRI ENTERPRISE (BID ID -3131839)
TORQUE ELECTRICAL (BID ID -3130358)
shivalay corporation (BID ID -3135007)
TRIMURTHI ENTERPRISES (BID ID -3135020)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .