Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹69.3 L+₹2.7 L (4.03%)Admitted-Finance B4 60 1 NEW SANTOSHPUR THANDER PARA STATION ROAD 24 PARGANAS SOUTH PIN 700142 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 700142 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KAY BEE ASSOCIATES L1 | DGR CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3 core complete all as specified and as directed. | 20 | Rm | 1,800 ₹36,000 Lowest | 2,000 ₹40,000 |
| 2.00 | Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 120 Sqmm 3 core complete all as specified and as directed. | 250 | Rm | 2,970 ₹7,42,500 Lowest | 3,050 ₹7,62,500 |
| 3.00 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as spcified and as directed. | 2 | Each | 13,000 ₹26,000 | 3,500 ₹7,000 Lowest |
| 4.00 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as spcified and as directed. | 2 | Each | 16,500 ₹33,000 Lowest | 18,000 ₹36,000 |
| 5.00 | S& F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 sqmm complete all as specified and directed. | 2 | Each | 5,800 ₹11,600 Lowest | 6,200 ₹12,400 |
| 6.00 | S& F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed. | 3 | Each | 6,300 ₹18,900 Lowest | 6,500 ₹19,500 |
| 7.00 | M&L for finding out the fault to under ground HT cable by cable fault locator machine or manually excavation and rectify the fault and laying the cable as before in the trenches all as required and directed by Engr-in-Charge.
Note: Material i.e Jointing kit will be paid seperatly and all labour/fixing charges/rectification is included in the rate. | 2 | Each Job | 9,000 ₹18,000 Lowest | 9,500 ₹19,000 |
| 8.00 | M&L for finding out the fault to under ground LT cable by cable fault locator machine or manually excavation and rectify the fault and laying the cable as before in the trenches all as required and directed by Engr-in-Charge.
Note: Material i.e Jointing kit will be paid seperatly and all labour/fixing charges/rectification is incl in the rate. | 2 | Each Job | 4,000 ₹8,000 Lowest | 4,200 ₹8,400 |
| 9.00 | Maintenance of Ring main unit of any make, 11.0 KV Grade, 630 Amps by licensed electrician including the following:-
(a) Switiching off RMU and conforming that supply to incomming end is properly disconnecte.
(b) Opening covers of the RMU and visual checking of epoxy housing and all parts for rust and wear.
(c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.
(d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.
(e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.
(f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately).
(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections.
Note : 1. After servicing of RMU, Health check up reports will be submitted. | 1 | Each Job | 19,000 ₹19,000 Lowest | 20,510 ₹20,510 |
| 10.00 | Maintenance of Vaccum circuit Breaker of any make, 11.0 KV Grade, 200 to 630 Amps by licensed electrician including the following:-
(a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte.
(b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear.
(c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.
(d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.
(e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.
(f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately).
(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections.
Note : 1. After servicing of VCB, Health check up reports will be submitted. | 6 | Each Job | 12,000 ₹72,000 Lowest | 14,000 ₹84,000 |
Tender Value
₹42.6 L
EMD Value
₹85,200
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (I) (CG N) KOLKATA
GE (I) (CG N) KOLKATA 700023
MAINTENANCE AND REPAIRS TO EXTERNAL ELECTRIC SUPPLY SYSTEM DG SET EXTERNAL WATER SUPPLY SYSTEM FIRE FIGHTING SYSTEM FIRE ALARM SYSTEM SWIMMING POOL INCL CERTAIN MISC WORKS AT HALDIA UNDER GE (I) (CG N) KOLKATA
2026_MES_762634_1
8701/06/2026-2027/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Haldia
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) (CG N)
₹85,200
Yes
4 Jun 2026
28 Apr 2026
20 May 2026
28 Apr 2026
19 May 2026
13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3 core complete all as specified and as directed. | 20 | Rm | - | - |
| 2 | Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 120 Sqmm 3 core complete all as specified and as directed. | 250 | Rm | - | - |
| 3 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as spcified and as directed. | 2 | Each | - | - |
| 4 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as spcified and as directed. | 2 | Each | - | - |
| 5 | S& F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 sqmm complete all as specified and directed. | 2 | Each | - | - |
| 6 | S& F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed. | 3 | Each | - | - |
| 7 | M&L for finding out the fault to under ground HT cable by cable fault locator machine or manually excavation and rectify the fault and laying the cable as before in the trenches all as required and directed by Engr-in-Charge.
Note: Material i.e Jointing kit will be paid seperatly and all labour/fixing charges/rectification is included in the rate. | 2 | Each Job | - | - |
| 8 | M&L for finding out the fault to under ground LT cable by cable fault locator machine or manually excavation and rectify the fault and laying the cable as before in the trenches all as required and directed by Engr-in-Charge.
Note: Material i.e Jointing kit will be paid seperatly and all labour/fixing charges/rectification is incl in the rate. | 2 | Each Job | - | - |
| 9 | Maintenance of Ring main unit of any make, 11.0 KV Grade, 630 Amps by licensed electrician including the following:-
(a) Switiching off RMU and conforming that supply to incomming end is properly disconnecte.
(b) Opening covers of the RMU and visual checking of epoxy housing and all parts for rust and wear.
(c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.
(d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.
(e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.
(f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately).
(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections.
Note : 1. After servicing of RMU, Health check up reports will be submitted. | 1 | Each Job | - | - |
| 10 | Maintenance of Vaccum circuit Breaker of any make, 11.0 KV Grade, 200 to 630 Amps by licensed electrician including the following:-
(a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte.
(b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear.
(c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.
(d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.
(e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.
(f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately).
(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections.
Note : 1. After servicing of VCB, Health check up reports will be submitted. | 6 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
tender.pdf
Tender Documents • 0.87 MB
BOQ_854268.xls
BOQ • 8.47 MB
amendsch.pdf
PDF • 0.41 MB
amendate.pdf
PDF • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .