DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
M&R to EI in Various Types Of Residential Quarter at Sector-26 to 30, Gandhinagar (As Per Requirement For 1 Year)
296926
01/07 OF 2026/2027
Open
Electrical
Gandhinagar
7 documents required · 7 mandatory
₹900
DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
₹8,500
15 Apr 2026
15 Apr 2026
15 Apr 2026
28 Apr 2026
15 Apr 2026
Name of Work M&R to EI in Various Types Of Residential Quarter at Sector-26 to 30, Gandhinagar (As Per
Requirement For 1 Year)
Fund Head : 2216 Housing M&R SR
Sr. No. Item No. Particulars. Qty. Rate Amount
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Name Of Work :- M&R to EI in Various Types Of Residential Quarter at Sector-26 to 30, Gandhinagar (As Per
Requirement For 1 Year)
Item Estimated Rate in Rs.
Item Description Unit Amount in Rs.
No. Quantity in Figure In Word
Replacing old and u/s by Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected Rupees Four
on PVC / Metallic/Wooden box, single mounting base Hundred Forty
frame covered with textured/metallic/white front plate Nine And Paise
modules erected on / in wall / ceiling as per pipe erected, Forty Five Only
with necessary Lamp holder/ceiling rose / H.D.Connector
as directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete Cat.
III (As Per Requirement)
Replacing old and u/s by Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected
on PVC / Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected,
2 15 pts 224.73 Four And Paise pt
with necessary Lamp holder/ceiling rose / H.D.Connector
NOTE:-2 For point wiring in bathroom and W/C and
washbasin area in residential quarters reduce overall rate
by 50% of point wiring for light. (a) with medium class
Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete Cat. III (As Per Requirement)
Replacing old and u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and
accessories with earth continuity of following type erected
3 30 pts on PVC / Metallic/Wooden box, single mounting base 638.32 pt
Eight And Paise
frame covered with textured/metallic/white front plate
Thirty Two Only
modules erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete Cat. III (As Per
Replacing old and u/s by Point wiring for on board Looped
Plug with 6A Modular type switch & 5 pin socket erected Rupees Two
on PVC / Metallic/Wooden box, single mounting base Hundred Fifty
4 20 pts frame covered with textured / metallic/white front plate 257.55 Seven And pt
modules erected on / in wall / ceiling with following type Paise Fifty Five
accessories Cat. III (As Per Requirement) Only
Replacing old and u/s by Point wiring for Two Way
Controlled Light Point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires erected in
below type of pipe with 6A Modular type switches and
following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame
5 15 pts 567.62 Seven And pt
covered with textured / metallic/white front plate modules
Paise Sixty Two
erected on / in wall / ceiling as per pipe erected. with
necessary batten/angle holder or ceiling rose or
H.D.Connector as directed. (a) with medium class Rigid
PVC pipe and accessories erected flushed on wall/ceiling
complete Cat.III (As Per Requirement)
Replacing old and u/s by Providing following type of
Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation
directed by Engineer In charge.
(1)One No. SP 6 Amp. Cat.III (As Per Requirement)
90 nos 151.50 Each
(2) One No 5 pin plug Cat.III (As Per Requirement) Rupees One
40 nos 151.50 Each
(5) Electronic hum Free steps EME Fan regulator Cat.III Rupees Three
(As Per Requirement) Hundred Ninety
50 nos 398.95 Each
Eight And Paise
Ninety Five Only
(7) Blank Plate Single Cat.III (As Per Requirement) Rupees Twenty
20 nos 25.25 Each
(9) 16 Amp. SP one way switch Cat.III (As Per Rupees One
Requirement) Hundred Eighty
25 nos 180.79 And Paise Each
(10) 6/16Amp. Universal socket Cat.III (As Per Rupees One
Requirement) Hundred Ninety
25 nos 199.98 Nine And Paise Each
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed
(a)20 mm (As Per Requirement) Rupees Twenty
200 mtrs 24.24 mtr
(b)25 mm (As Per Requirement) Rupees Thirty
Three And Paise
75 mtrs 33.33 mtr
Providing & erecting PVC Corrugated Flexible Conduit
8 with required nos. of coupling, PVC bushes, Check-nuts
etc. complete of following sizes.
(1) 20 mm (As Per Requirement) Rupees
25 mtrs 17.17 mtr
Paise Seventeen
Replacing old and u/s by Providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
9 to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
(E) in existing pipe (a) 2 wire 1.5 sq. mm (As Per Rupees Forty Six
200 mtrs Requirement) 46.46 And Paise Forty mtr
(E) in existing pipe (b) 2 wire 2.5 sq. Mm (As Per Rupees Sixty
150 mtrs Requirement) 62.62 Two And Paise mtr
Replacing old and u/s by providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size
(E) in existing pipe (a) 2 wire 4 sq. Mm (As Per Rupees Eighty
120 mtrs Requirement) 86.86 Six And Paise mtr
Eighty Six Only
(E) in existing pipe (b) 2 wire 6 sq. Mm (As Per
50 mtrs 121.20 mtr
(E) in existing pipe (i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm ) (As Per Requirement)
20 mtrs 398.95 mtr
Eight And Paise
Ninety Five Only
Supplying and erecting Flexible PVC insulated multi strand
multi core 1.1 kv grade ISI marked copper wires of Rupees Forty Six
11 100 mtrs following size to be erected as directed. 46.46 And Paise Forty mtr
(e) 1.50 Sq.mm 3 core round PVC sheathed (As Per Six Only
(h) 2.50 Sq.mm 3 core round PVC sheathed (As Per
200 mtrs 77.77 mtr
Replacing old and u/s by providing and erecting Mains
with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
(e) One wire 6.00 sq. Mm (As Per Requirement) Rupees Fifty Six
75 mtrs 56.56 And Paise Fifty mtr
(f) One wire 10.00 sq. Mm (As Per Requirement)
100 mtrs 91.91 One And Paise mtr
Ninety One Only
Providing & Erecting 3mm thick Polycarbonate (PC) Rupees Three
13 1000 sq.inch sheet with grooving as directed (As Per Requirement) 3.03 And Paise Three sq.inch
Replacing old and u/s by providing and erecting
Decorative call bell Ting-tong box type 250 volts complete
14 10 nos erected (As Per Requirement) 71.71 Each
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more
than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Tube Light with integral driver Rupees Three
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet Hundred
200 nos Cat-lll (As Per Requirement) 373.70 Seventy Three Each
Supplying and erecting led lamps with following wattage
capacity of 220 to 240 voltage, minimum 15000 burning
hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp
16 75 nos 188.87 Eight And Paise Each
(A) LED Lamps integral type, with PC diffuser suitable
LAMP holder (iii) 10 to 15 watts cat-III (As Per
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
17 15 nos Luminaire efficacy> 85 lumens/watt , 589.84 Each
LED driver efficiency > 85 %
Eighty Four Only
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Square/
Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV Cat-lll (As Per Requirement)
Replacing old and u/s by Supplying and erecting LED
street light / Flood light fittings with High power White
LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or Rupees Four
embossed 160 to 270 V,Power Factor more than 0.95, Thousand Nine
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio Hundred Ninety
18 25 nos 4,997.48 Each
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver Seven And
efficiency > 85 %.( fittings required LM-79 & LM-80 Paise Forty Eight
certificates)(NOTE: Below description have shown ranges Only
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
shown.) (A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply with
over-voltage protection.(ii) above 48 to 60 Watts Cat-lll
(As Per Requirement)
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Rupees Five
Factor more than 0.95, THD < 10 %, CCT 3000 K to Thousand Five
19 6 nos 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 5,599.44 Hundred Ninety Each
lumens/watt . LED driver efficiency > 85 %.( fittings Nine And Paise
required LM-79 & LM-80 certificates)(NOTE: Below Forty Four Only
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (B) Flood
Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage
protection. (ii) above 48 to 60 Watts Cat-lll (As Per
Replacing old and u/s by providing and erecting Miniature
circuit breaker single pole 6A to 25A suitable to operate Rupees One
on 240 V A.C. system and having breaking capacity 10 Hundred Twelve
20 30 nos 112.11 Each
KA to be erected in existing box. confirming to IS And Paise
8828/1996 with ISI Mark Cat.III (As Per Eleven Only
Replacing old and u/s by Providing & erecting 240 V MCB
double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity
(B) 40 Amp. Cat.III (As Per Requirement) Rupees Three
20 nos 330.27 And Paise Each
Replacing old and u/s by Providing & erecting 415 V MCB
Four Pole for Motor & Inductive Load (C Curve) having
22 3 Nos 10KA breaking capacity & confirms to IS :8828 in existing 737.30 Each
box having following capacity (c)63 Amp. Cat.III
Paise Thirty Only
(As Per Requirement)
Replacing old and u/s by Providing and Erecting Plastic Rupees One
enclosure fitted with DIN rail suitable for incorporating Hundred Eight
23 3 nos 108.07 Each
Three /Four nos. MCB (As Per Requirement) And Paise
Replacing old and u/s by Providing and Erecting Sheets
steel powder coated enclosure suitable for incorporating
One/Two nos. MCB. (As Per Requirement)
24 20 nos 176.75 Seventy Six And Each
Replacing old and u/s by Providing and erecting Sheet
Steel powder coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral link, earth bar
25 and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(A) single phase incoming and horizontal single phase Rupees One
outgoing Thousand One
2 nos (b) sheet steel double door (IP-43) 1,152.41 Hundred Fifty Each
(iii)8 way (As Per Requirement) Two And Paise
(A) single phase incoming and horizontal single phase Rupees One
outgoing Thousand Four
(b) sheet steel double door (IP-43) Hundred Ninety
4 nos 1,492.78 Each
(iv)12 way (As Per Requirement) Two And Paise
(B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI) (b) sheet steel
double door (i)4 way (As Per Requirement)
1 nos 2,339.16 Hundred Thirty Each
Replacing old and u/s by providing and erecting Approved
make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity Rupees Two
of 10 KA and suitable for operation on single phase 240 Thousand Two
26 25 nos V,50Hz. having characteristic of quick action & tripping 2,235.13 Hundred Thirty Each
with all advance feature & do not incorporate any Five And Paise
electronic component. for following Max. rating erected as Thirteen Only
directed (ii) 40Amps. DP Cat. III (As Per Requirement)
Providing and erecting HOT deep Galvanised iron strip
wire 8 to 16 SWG. (As Per Requirement)
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation
duly stamped and signed by agency and officer Incharge
has to ensure the value of earthing resistane mentioned in
4,591.46 Hundred Ninety Each
test Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up
to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg. (As Per
Replacing old and u/s by Providing and erecting Approved
make Ceiling fan with double ball bearing ISI mark with
condenser A.C. 23OV.50 c/s.1200 mm. sweep complete,
29 25 nos 1,596.81 Hundred Ninety Each
canopy erected on existing hook or clamp with earthing.
[Make shall be approved by Engineer in charge] (As Per
Eighty One Only
Replacing Old & u/s by new Providing 2.5mm.thick
Rupees Eighteen
laminated acrylic sheet to cover the fan hook or Fan box.
30 25 nos 18.18 And Paise Each
(As Per Requirement)
Replacing old and u/s by Supplying & erecting approved
make low noise decorative exhaust fan having square
frame ABS body with inbuilt lowers & square
31 2 nos 1,703.87 Hundred Three Each
frame.200mm with 1350RPM Cat.II (As Per Requirement)
And Paise Eighty
Replacing old and u/s by Providing & erecting open well
type horizontal mono block pump set with stainless steel Rupees Nine
body having following specification Thousand Six
(C) 1 H.P. single phase open well motor pump set Hundred
32 2 nos 9,613.18 Each
suitable for 185 LPM discharge @ 25 mtr. head, suitable Thirteen And
for 32 mm dia. Delivery pipe with control panel. Paise Eighteen
Cat. II (As Per Requirement) Only
Supplying & erecting approved make Automatic liquid
level controller 6A. with sensor testing as per instruction of
Engineer in charge on site complete with wiring
33 2 nos 2,355.32 Hundred Fifty Each
connection with existing wires , with copper conductor
from pump to upper and lower tank. (As Per
Thirty Two Only
Replacing old and u/s by Providing and erecting ISI
marked PVC insulated PVC Sheathed Flat flexible
34 50 mtrs Submersible copper cable approved make of following 104.03 mtr
And Paise Three
(B) 3 Core x 2.5 Sq. mm. (As Per Requirement)
Replacing old and u/s by Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured cable Aluminium
conductor for 1.1 KV. to be laid on wall with necessary
35 50 mtrs 92.92 Two And Paise mtr
clamps or in existing trench / pipe of following size of
Ninety Two Only
(B) 2 core 6 Sq. mm (As Per Requirement)
Replacing old and u/s by Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Rupees One
Aluminium conductor for 1.1 KV. to be laid on wall with Hundred Forty
36 80 mtrs 140.39 mtr
necessary clamps or in existing trench / pipe of following And Paise Thirty
size of cables Nine Only
(C) 4 core 10 Sq. mm (As Per Requirement)
Making trench in soft soil of suitable width of 90 cm deep
for laying cable or locating the fault all over the run and
37 50 mtrs 55.55 Five And Paise mtr
back filling the same and making the surface as normal
Fifty Five Only
ground. (As Per Requirement)
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
38 15 mtrs making up to following size of holes at both ends 492.88 mtr
complete. (A) Up to 100 mm bore dia (As Per
Eighty Eight Only
Supplying & erecting approved make SMC press
moulded composite FRP. loop-in, loop-out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged doors Rupees Eight
as per requirement having locking arrangements with Hundred Ninety
39 30 nos 898.90 Each
mounting clamp with nuts, bolts & washers suitable for Eight And Paise
erection on pole with cable clamps& earth bolt of following Ninety Only
size of box. (A) 300mm x 200mm x 100mm [deep] (As
Per Requirement)
Supplying and erecting B class galvanised iron pipe
mm outside dia 45 cm long duly welded on 20 cm x 20 cm Rupees Three
x 3 mm thick M.S. base plate, erected on wall or corner for Hundred Forty
40 5 nos 343.40 Each
mounting street light luminaire with necessary hardware Three And Paise
materials duly painted. (As Per Requirement) Forty Only
Replacing Old u/s by new Supplying & erecting approved
make Digital time switch having lithium cell 6 years
operative and operate battery backup 1 channel day clock
with 14 memory programme, suitable to operate on 240V
+ 5%, 16A with, floating contacts Minimum switching
41 3 nos setup time 1 minimum & LCD display. Also comprised 3,168.37 Each
Eight And Paise
permanent ON/OFF switching. Programming switches &
housed in fire proof thermoplastic enclosure & transparent
cover erected as required with necessary connection
erected as directed. (As Per Requirement)
Replacing Old u/s by new Supplying & erecting power
contactor ,AC3 duty for time switch complete erected as
per direction Cat III
42 3 nos 2,782.55 Hundred Eighty Each
(D) 4 pole 440V 40 Amp. (As Per Requirement)
Fifty Five Only
Replacing Old u/s by new Providing and erecting
Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 25 KA. at 415 V,having
normal current rating up to 25 A to 100A. with Fixed
43 2 nos thermal & magnetic release suitable to work on A.C. 6,173.12 Each
supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
(As Per Requirement)
Replacing Old u/s by new Providing and erecting
Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415 V. having
normal current rating 125A. with Fixed thermal &
44 2 nos magnetic release suitable to work on A.C.supply 50 c/s. 8,055.76 Each
with all internal connections, spreader tinned copper &
Seventy Six Only
complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III (As Per
Replacing Old u/s by new Providing and erecting
Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. and above at 415 Rupees Twenty
V . having normal current rating 250A. with variable Thousand Nine
45 2 nos thermal & magnetic release suitable to work on A.C.supply 20,946.39 Hundred Forty Each
50 c/s. with all internal connections, spreader tinned Six And Paise
copper & complete erected in existing 16 G.M.S. housing. Thirty Nine Only
ICS=100% of ICU only Cat III (As Per
Providing and erecting Approved make Earth fault Relay
suitable to mount with inter connection suitable to
following size of moulded case circuit breaker having CT
46 2 ratio & MCCB rating as following along with shunt trip 4,687.41 Each
220V AC. with all internal connections & complete erected
Paise Forty One
in existing M.S.housing.. (1) 15 A -100 A , CT Ratio
1/100 (As Per Requirement)
(2) 125 A -200 A , CT Ratio 1/200 (As Per Requirement)
4 4,983.34 Hundred Eighty Each
Three And Paise
Thirty Four Only
(3) 250 A -400 A , CT Ratio 1/400 (As Per Requirement) Rupees Five
2 5,415.62 Hundred Fifteen Each
And Paise Sixty
RUPEES IN WORDS
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Put to Tender Rs. 846,738.05 Put to Tender Rs.
Deduct ______ % below_______________
(Please strike out whichever is not applicable)
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and other
factors pertaining to the work before submitting this tender.
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree to execute
the same accordingly.
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work shall be
rejected outright unless it is authenticated by the office opening the tender at the time of opening of tender.
5 Dismentaling the existing material taken by contractor as mention rates.
Signature of Deputy executive Engineer
C.P Electrical R & B Sub Dn
Less for the D.M
M&R to EI in Various Types Of Residential Quarter at Sector-26 to 30, Gandhinagar (As Per Requirement
Sr.no Item Qty. Per DM rate Total
1 Cost Of Old & u/s Light Pts. 50 Pts. 14.96
2 Cost Of Old & u/s Half Pts. 15 Pts. 7.48
3 Cost Of Old & u/s Fan Pts. 15 Pts. 22.44
4 Cost Of Old & u/s Looped Plug 20 Pts. 8.76
5 Cost Of Old & u/s Two way Pts. 15 Pts. 19.16
6 Cost Of Old & u/s 6A Switch 40 Nos. 5.60
7 Cost Of Old & u/s 6A Plug 20 Nos. 5.60
8 Cost Of Old & u/s Regulator 20 Nos. 15.40
9 Cost Of Old & u/s Blank Plate 20 Nos. 1.00
10 Cost Of Old & u/s 16A Switch 15 Nos. 6.76
11 Cost Of Old & u/s 16A Plug 15 Nos. 7.52
12 Cost Of Old & u/s 1.5 Mains 80 Mtr. 3.78
13 Cost Of Old & u/s 2.5 Mains 80 Mtr. 5.22
14 Cost Of Old & u/s 4 Mains 50 Mtr. 7.20
15 Cost Of Old & u/s 6 Mains 20 Mtr. 10.26
16 Cost Of Old & u/s 4x10 Mains 20 Mtr. 34.65
17 Cost Of Old & u/s 6.00 Sq.mm Wire 25 Mtr. 4.77
18 Cost Of Old & u/s 10.00 Sq.mm Wire 30 Mtr. 7.92
19 Cost Of Old & u/s Ting Tong Bell 10 Nos. 2.60
20 Cost Of Old & u/s T-5 Tube light 100 Nos. 18.00
21 Cost Of Old & u/s Downlight 10 Nos. 22.00
22 Cost Of Old & u/s St. Light Fitting 5 Nos. 191.12
23 Cost Of Old & u/s MCB SP 30 Nos. 4.90
24 Cost Of Old & u/s 40A DP MCB 20 Nos. 18.50
25 Cost Of Old & u/s 63A FP MCB 3 Nos. 35.20
26 Cost Of Old & u/s four nos. Enclosures 3 Nos. 4.70
27 Cost Of Old & u/s Enclosure DP 20 Nos. 9.50
28 Cost Of Old & u/s 8 way DB Single phase 2 Nos. 64.00
29 Cost Of Old & u/s 12 way DB Single phase 2 Nos. 70.60
30 Cost Of Old & u/s 8 way DB Three phase 1 Nos. 193.25
31 Cost Of Old & u/s 40A DP ELCB 12 Nos. 128.00
32 Cost Of Old & u/s Ceiling fan 10 Nos. 237.60
33 Cost Of Old & u/s Ex. Fan 2 Nos. 173.70
34 Cost Of Old & u/s 1 HP Motor Pumpset 1 Nos. 943.65
35 Cost Of Old & u/s 3x2.5 sq.mm Flat Cable 20 Mtr. 10.44
36 Cost Of Old & u/s 2x6 sq.mm Al. Cable 20 Mtr. 5.98
37 Cost Of Old & u/s 4x10 sq.mm Al. Cable 30 Mtr. 8.13
38 Cost Of Old & u/s Timer 1 Nos. 146.00
39 Cost Of Old & u/s Contactor 1 Nos. 128.80
40 Cost Of Old & u/s 25 to 100A MCCB 2 Nos. 299.20
41 Cost Of Old & u/s 125A MCCB 2 Nos. 392.40
42 Cost Of Old & u/s 250A MCCB 2 Nos. 1030.55
Sr.no Item Qty. Per DM rate Total
Dy.Executive Engineer Exe.Engineer
Sign of Contractor Cap.Proj. Elect.sub.Div-21 C.P.Electrical Division
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
Notice No. 1 of 2026-27 online.pdf
PQ.pdf
SCHEDULE A B AND DM.pdf
STANDARD BIDDING DOCUMENT.pdf
Download all tender documents and submit your bid