Tender Value
₹7.1 L
EMD Value
₹14,260
Closing Date
29 Oct 2024, 2:00 pmClosed
DGM EDCC
Office of the Dy General Manager, Capital Complex Electrical Division, 79 Tilla, Agartala, West Tripura
Extension of HT line to 200KVA Transformer for providing service connection to Assistant Director, SIB, MHA, Govt. of India under CPWD at Salbagan under ESD Durjoynagar
2024_POWER_54045_1
DGM/EDCC/2024-25/9 Dated.11/09/2024
Open Tender
Electrical Works
Works
60 days
Salbagan, Durjoynagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹944
₹14,260
6 Mar 2025
22 Oct 2024
29 Oct 2024
22 Oct 2024
29 Oct 2024
24 Oct 2024
22 Oct 2024 - 23 Oct 2024
Amount
(ERECTION)
Erection of 9 mtr length of Steel Tubular Pole at any kind of soil upto a depth of 1/6 th of pole height, i/c excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of Stay set complete direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm thimble turn buckle, 7/3.15 mm dia G.I. stranded stay wire and train insulator etc. with supply of (TSECL Supply)
Laying and stringing of 1KM(Single Conductor) ACSR (6/1/2.59) mm dia WEASEL i/c hoisting & binding etc complete as required.
Erection of 2.8 mtr long 75X40X40X6mm MS Channel Bracket
Erection of MS Channel Cross arm 0.3 to 1.2 mtr long 75X40X40X6mm
Erection of 1 to 2.5 mtr long 65X65X6mm MS Angle
Erection of 2.8 mtr long 65X65X6mm MS angle Bracket
Erection of 11 KV 3 ph GOS Complete Set (i/c the cost of back clamp, nuts & bolts etc.) with all necessary Connection.
Erection of 11 KV DOF 3 ph including all necessary connection complete as per technical specification.
Erection of 11 KV pin insulator with G.I. pin (TSECL Supply)
Erection of 11KV Sngle Disc insulator set along with necessary fittings.
Erection, testing and commissioning of 11 KV, 630 Amp continuous current 350MVA rupturing capacity indoor Vaccum Circuit breaker (feeder incoming panel) complete with control and relay panel simplex type with 3 phase panel top mounted PT ratio 11000/110 volt, electrical closing mechanism & internal wiring, 2 over current & with internal wiring, 2 overcurrent & 1 earth fault combined relay, auxiliary relay, 3 ammeter, 1 voltmeter, CT operated static KWH meter, including panel bus CT with 100- 50/1 A with integral earthing facility & "internal arc tested". (Outgoing) Specification should be Confirming the following 1. TMV should be L&T make (ER-300P). 2. C.T. operated Static KW meter shold be included. 3. Master Triping relay should be Alstom Make VAJH-13. 4. Analog meter and TVM CT Ratio should be 200-100/1 Amp. 5. MCCB in Axu.DC supply circuit.
(SUPPLY of the following)
Cable( XLPE 11KV) 3CX70sqmm
11KV cable kit for XLPE 3-core 70sqmm Indoor/Outdoor type.
Stay Clamp
Bkt. Clamp
M.S. Nuts & Bolts (As.)
HDPE pipe 110mm outer dia of 6mtr length.
Design Engineering, Supply of of 11 KV, 630 Amp continuous current 350MVA rupturing capacity indoor Vaccum Circuit breaker (feeder incoming panel) complete with control and relay panel simplex type with 3 phase panel top mounted PT ratio 11000/110 volt, electrical closing mechanism & internal wiring, 2 over current & with internal wiring, 2 overcurrent & 1 earth fault combined relay, auxiliary relay, 3 ammeter, 1 voltmeter, CT operated static KWH meter, including panel bus CT with 100- 50/1 A with integral earthing facility & "internal arc tested". (Outgoing) Specification should be Confirming the following 1. TMV should be L&T make (ER-300P). 2. C.T. operated Static KW meter shold be included. 3. Master Triping relay should be Alstom Make VAJH-13. 4. Analog meter and TVM CT Ratio should be 200-100/1 Amp. 5. MCCB in Axu.DC supply circuit.
(Civil Works)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 11 KV grade of all size in the GI Pipe/HDPE for riser including tieup of pipe with pole by the help MS flat clamp(excluding cost of clamp and Nut & bolts) as required
Laying of 11 KV 3 core ,70 sqmm XLPE UG Cable in the ground i/c excavation,sand cushioning,protective covering and refilling the trench etc as reqd.Trench size:Width:350mm,Height:1200mm/sand cushioning:Height:250mm,Width:350mm/Protection:Double layer brick.
Coiling of excess single/3 core/3 1/2 core up to 400 sqmm HV/MV, XLPE insulated,armoured power cable direct in to earth including excavation of earth upto a 1500 mm (size pit should be 2250mmx2250mm or as per site requirement including 1st class brick protection of two layer flat brick soiling,300mm.Fine sand (local query) for cushioning/bed and refilling and ramming the excavation soil as per direction of Engineer in Charge.
Grouting of 3Nos.Steel tubular poles of ratio 1:2:4 ( 1 cement : 2 river sand : 4 Jhama brick aggregate of 20mm nominal size) inchluding supply of cement sand and brick aggregate complete with excavation, refilling of earch, ramming alongwith centering & shuttering as reqd. @ 0.273 Cum per pole. ( 0.273 x 5= 1.365)
(CARRYING OF THE FOLLOWINGS)
Carriage of Line materials such as cable, ACSR, G.I. Wire Cross-Arm, Stay Set, insulator etc. By Mechanical Transport from A.D. Nagar Store Sub-Division to Sub-Division office, Sub-Division office to work site.
Carriage of G.O.S,D.O.F,LA,etc by Mechanical Transpot from from A.D. Nagar Store Sub-Division to Durjoynagar Sub-Division office & Sub-Division office to work site.
Carriage of 9mtr. Long Steel Tubular Pole from Store to work site.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .