| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.3 L+₹2.1 L (6.84%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹34.0 L+₹2.8 L (9.05%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹36.5 L+₹5.3 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected being not enlisted in appropriate category i.e. b (iii) |
Tender Value
₹40.0 L
EMD Value
₹79,920
Closing Date
21 Sept 2023, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
MAINTENANCE AND REPAIR OF 132/11 KV TRANSFORMERS, CONTROL PANELS, CABLES, EARTHINGS AND ALLIED WORKS AT MRS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
2023_MES_615553_1
8867/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM, Visakhapatnam
₹79,920
Yes
27 Dec 2023
24 Aug 2023
28 Sept 2023
24 Aug 2023
21 Sept 2023
7 Sept 2023
Amount
Material and labour for filtration/dehydration transformer oil of transformer voltage grade 132/11 KV, capacity 20/25 & 10/16 MVA outdoor type, floor mounted in situ till achieve dielectric strength minimum 60 KV at 4mm gap all as specified and directed.
M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 132/11 KV grade in main tank and OLTC including necessary dehydration to achieve dielectric strength min 60 KV at 4mm gap complete all as specified and directed. Make – GULF/Castrol/ HP /IOC /Savita /Power.
M&L for chemical analysis test comprising (i) Disolve gas analysis, (ii) Acidity, (iii) water content, (iv) Sludge, (v) Die electric dissipation factor, (vi) Specific registance, (vii) Flush point, (viii) Density (ix) Apearence, (x) Electric strength, (xi) Interfacial Tension of transformer oil of 132/11 KV transformer by taking out at 5.0 ltr container and transporting to govt approved lab at Visakhapatnam or at near by Cities including submission of test report.
Note for item No. 1.00 to 3.00 :- (a) New transformer oil to be bought in company sealed ISI marked container with test certificate and cost of container & transportation & lab test shall be inclusive of the quoted rate (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and required pipe connection from filter machine to transformer shall be made and rate shall be inclusive of quoted rate. (c) Necessary filter/dehydration plant having pressure gauge, hour meter, temperaturature gauge to be brought at site by contractor and to be kept permanently inside ND (V) till completion of work and rate deemed to be included in the quoted rate. In any condition, in-out of the filter machine during the progress of the work will not be allowed. (d) Transformer oil test report before and after dehydration/filtration shall be submitted duly authenticated by authorised person .
M & L for replacement of silica gel grains in the breather assembly of transformer complete all as specified and directed.
M & L for replacement of breather assembly made with polycarbonate base and clear acylic glass of size to accommodate 2.0 kg of silica gel for transformer complete all as specified and directed.
M&L for maintenance of OLTC by draining out transformer oil, dismantling all internal connections, opening top cover, taking out carefully, cleaning all sludge from OLTC chamber, replacement of oil, refixing to original position, testing, commissioning complete all as specified and directed. Note : Transformer oil shall be measured separately
Periodical cleaning of complete transformer outer surface including 132 KV bushings, radiators, marshaling tank with volatile cleaning agent at every alternate 3 month to keep the complete outside surface dry and clean all as specified and directed. (Note : Each job measured in one quarter as one unit.
M&L for servicing of set of auxilary tripping relays and master trip relays by taking out from 132 KV relay control panel, cleaning of fixed and moving contact points and checking for proper functioning of relays all as specified and directed. Make - L&T or equivalent of ABB/Schneider.
Supply and fix 4 pole power contactor AC3 rating 25A, for radiator fans inside control panel box fixed at body of transformer all as specified and directed. Make- L&T, Model MDX 9 or equivelent of ABB/Schneider.
M&L for fixing copper earth strip of size 32mm x 6mm making drilled hole at both ends and fixing to transformer earth point / earth test point incl dismantling taking down old rusted steel earth strip all as specified and directed.
Taking down unserviceable / burnt power capacitor from the structure after disconnecting the strips, nuts, bolts and supply, installation, testing and commissioning new HT capacitors unit with the following specifications : (i) Rated output 222 KVAR (ii) Voltage 6.93 KV (iii) Rated capacity 14.72 MFD (iv) Current 32.03 Amps (v) Tolerance -5% to +10% (vi) Frequency - 50 Hz (vii) Temperature category 50 (viii) Insulation level 28/75 (ix) Type of electricity : PP type of impregnant NPCB
Taking down unserviceable / burnt power capacitor from the structure after disconnecting the strips, nuts, bolts and supply, installation, testing and commissioning new HT capacitor unit with the following specifications : (i) Rated output 363 KVAR (ii) Voltage 6.93 KV (iii) Rated capacity 14.72 MFD (iv) Current : 52 Amps (v) Tolerance -5% to +10% (vi) Frequency - 50 Hz (vii) Temperature category 50 (viii) Insulation level 28/75 (ix) Type of electricity : PP type of impregnant NPCB
Supply and fix harmonically detuning series reactor single phase 15.5 KVA 32 Amps for 600 KVAR 11000 Volts 3 Phase 50 Hz with free mounting on outdoor structure aluminum wound air cooled reactor insulation class `F' temperature 120° detuning lowest harmonic order 5th 20.48 mh/ph 73.20A all as specified and directed Note : (i) The contractor must personally supervise the entire, proceedings of the activity any damage occurred during execution of work, he is solely responsible for payments of damaged. (ii) Scanning of harmons by conducting the reactor effectiveness, test with the testing equipment for 3 phase 11 KV system capacities upto 600 KVAR and submission of necessary test result to Engineer-in-Charge. (iii) The unit rate quoted shall be deemed to be included for total proceedings regarding testing, commissioning, erection.
Supply and fix harmonically detuning series reactor single phase 31 KVA 64 Amps for1200 KVAR, 11000 Volts 3 Phase 50 Hz with free mounting on outdoor structure aluminum wound air cooled reactor insulation class `F' temperature 120° detuning lowest harmonic order 5th 20.48 mh/ph 73.20 A all as specified and directed Note : (i) The contractor must personally supervise the entire, proceedings of the activity any damage occurred during execution of work, he is solely responsible for payments of damaged. (ii) Scanning of harmons by conducting the reactor effectiveness, test with the testing equipment for 3 phase 11 KV system capacities upto 1200 KVAR and submission of necessary test result to Engineer-in-Charge. (iii) The unit rate quoted shall be deemed to be included for total proceedings regarding testing, commissioning, erection including two coats of painting fuse structure.
M&L for painting of old painted steel structure/MS laddder surface of tower lights with one coat of red oxide and two coat of synthetic enamel paint complete all as specified and as directed
Material & labour for cleaning of 132 outdoor kit, removing all dirt and dust accumulated inside fins with suitable cleaning agent cleaning of complete mounting MS structure and painting with one coat of aluminium paint opening and reconnection of all earth terminals after cleaning jointing surfces complete all as specified and as directed.
Supply & fixing 132KV, horizontal double break isolators "GRPS" make, 132 KV, triple pole, 31.5 KA centre post rotating horizontal double break type isolators suitable for upright mounting with manual operated mechanism for main switch and earth switch (i.e. mechanically gang operated) with all accessories required for normal operation of the isolator, but without support insulators, without supporting structure and without terminal connectors with following configuration (copper design) : - a) For 800 Amps with one earth switch. b) Support insulators for the above isolators. One stack consisting of 325 KV having a creepage distance of 4495 mm and cantilever strength of 6 KN as manufactured & tested (31mm/KV) (Per No.). c) Terminal connectors for the above isolators a set of 06 Nos. Rigid type bimetallic terminal connectors suitable for single ASR Zebra conductor.
M&L for cleaning of 11 KV power capacitor bank with reactors and all mounting structures, 11KV cable kits, all supporting 11KV pin insulators, replacement of damaged 11KV pin insulator, opening and reconnection of all GI/AL strips of capacitor terminals after duly cleaning the surfaces, painting to complete mounting structure with one coat of aluminium paint, opening and reconnection of all earth terminals after cleaning jointing surfaces all as specified and directed.
M&L for complete opening of ACSR conductor after opening aluminium pad clamp by removing nuts, bolts from 132KV lightning arrestor decarbonizing all contact surface of ACSR, replacement of unserviceable aluminium PAD clamp suitable for panther ACSR conductor and 132KV Air break switch / Lightning arrestor terminal all as specified and directed
Maintenance, servicing, overhauling of vacuum circuit breaker of 11KV as per checklist which mainly include disassembling various parts (if necessary) to check for healthiness, cleaning, assembling, tightness checks, functional checks, timing checks, HV, CRM and IR etc. tests to be carried out to ensure healthiness of the entire VCB circuit and functioning of power & auxillary circuit and all control devices like spring charge motor, closing coil, tripping coil & its controls to be checked complete all as specified and directed. Note : Replacement of defective parts of VCB shall be measured and paid separately
Maintenance, servicing of numerical relay fitted with 11KV panel as per checklist which mainly include disassembling various parts (if necessary) to check for healthiness, cleaning, tightness checks, functional checks like Primary injection, Secondary injection tests to be carried out to ensure healthiness of entire protection circuit, metering circuit and functioning of all auxillary relays and overall control devices like TRIP/N/CLOSE switch, LOCAL/REMOTE switch & its's controls to be checked complete all as specified and directed. Note : Replacement of defective parts shall be measured and paid separately
Maintenance, servicing of numerical relay fitted on 132KV control relay panel as per checklist which mainly include disassembling various parts (if necessary) to check for healthiness, cleaning, tightness checks, functional & protection checks like Secondary injection test with six channel automatic relay test kit to be carried out to ensure healthiness of entire protection circuit, metering circuit and functional checks of all auxillary relays and overall control devices like TRIP/N/CLOSE switch, LOCAL/REMOTE switch & its's controls to be checked complete all as specified and directed. Note : Replacement of defective parts shall be measured and paid separately.
S&F including dismantling taking out unserviceable Buffer (for opening spring) for 800 to 1600A 11KV VCB complete all as specified and as directed. Make : Schneider only Part No.-MVIJ00098-01
Supply and fix including dismantling taking out unserviceable Buffer (for closing spring ) for 800A to 1600A 11KV VCB complete all as specified and as directed. Make :- Schneider only, Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable single (Read-Blue) phase busbar spout suitable for 800 Amps to 1250 Amps VCB complete all as specified and as directed. Make:- Schneider. Part No- MEP-39-32185
Supply and fix including dismantling taking out unserviceable single (Y) phase busbar spout for 800 Amps to 1250 Amps 11 KV VCB complete all as specified and as directed. Make:- Schneider. Model No. MEP-39-32186
S&F including dismantling taking out unserviceable (Red/Blue) phase bus bar spout suitable for 11KV, 1600 Amps to 2000 Amps VCB complete all as specified and as directed. Make: - Schneider. Model No. MEP-39-A0051301
S&F including dismantling taking out unserviceable (Y) phase bus bar spout suitable for 11KV, 1600 Amps to 2000 Amps VCB complete all as specified and as directed. Make:- Schneider Model No. MEP-39-A0051401.
S&F including dismantling taking out unserviceable (Red/Blue) phase bus bar spout suitable for 11KV, 2500 Amps VCB panel complete all as specified and as directed. Make:- Schneider. Model No. MEP-39-38178
S&F including dismantling taking out unserviceable (Y) phase bus bar spout suitable for 11KV, 2500 Amps VCB panel complete all as specified and as directed. Make:- Schneider. Model No. MEP-39-38179.
S&F including dismantling taking out unserviceable CT Spout (Red-Blue) suitable for VCB 1600 to 2000 Amps complete all as specified and as directed. Make:- Schneider. Model No MEP-39-34008
S&F including dismantling taking out unserviceable CT Spout (Y) suitable for VCB 1600 to 2000 Amps complete all as specified and as directed. Make:- Schneider. Model No MEP-39-34007
S&F including dismantling taking out unserviceable (Red/Blue) phase CT spout suitable for 11KV, 2500 Amps VCB panel complete all as specified and as directed. Make :- Schneider. Model No. MEP-39-38180.
S&F including dismantling taking out unserviceable (Y) phase CT spout suitable for 11KV, 2500 Amps VCB panel complete all as specified and as directed. Make :- Schneider. Model No. MEP-39-38211.
Supply and fix including dismantling taking out unserviceable CT spout suitable for 800 Amps to 1250 Amps VCB complete all as specified and as directed. Make :- Schneider. Part No- MEP-39-32187.
S&F of vacuum interruptur suitable for 11 KV VCB complete all as specified and as directed. Make:- Schneider. Model No. DRCVG2002-01.
All as per item No. 37 above but for Model No. VSLVG3002-01 complete all as specified and directed.
All as per item No. 37 above but for Model No. VSLVG4002-01 complete all as specified and directed.
All as per item No. 37 above but for Model No. DRCVG5002-02 complete all as specified and directed.
S&F closing coil assembly in replacement of 110 V DC suitable for 11KV VCB including necessary connection and testing complete all as specified and directed. Make :- Schneider. Part No. ECO39SN134900FN
S&F in replacement of tripping coil 110V DC suitable for 11KV VCB including necessary connection and testing complete all as specified and directed. Make : Schneider. Part No. ECO39SN134100FN
S&F including dismantling taking out unserviceable breaker wheel - cast iron for 800A to 2500A complete all as specified and directed. Make : Schneider. Part No. MVIA00025-01.
Supply and fix including dismantling taking out unserviceable spring charging universal motor with gear box 220V AC for 800A to 2500A 11 KV VCB complete all as specified and as directed. Make:-Schneider.
Supply and fix including dismantling taking out unserviceable busbar supporting insulator for 800A to 1600A 11 KV VCB complete all as specified and as directed. Make-Schneider Part No. MEP-39-A0147901.
Supply and fix including dismantling taking out unserviceable rectifier unit (monoblock) for spring charging motor for 800A to 1600A 11 KV VCB complete all as specified and as directed. Make:-Schneider. Part No. ERC-A-A00DC-001.
Supply and fix including dismantling taking out unserviceable drive beam suitable for 11 KV VCB 800 to 2500 Amps complete all as specified and as directed. Make:- Schneider. Model No.- MSM3950118600FN
Supply and fix epoxy body suitable for 11 KV VCB up to 2500 Amps complete all as specified and as directed. Make :- Schneider. Model No MEP3953022000FN-22
Supply and fix including dismantling taking out unserviceable Shutter assembly for busbar / circuit spout suitable for 11 KV VCB up to 800A -2500 Amps complete all as specified and as directed. Make:- Schneider. Model No. SPP0009-04.
M&L for THERMOGRAPHIC TESTING of 11kV switch boards with IMAGE INFRARED CAMERA to detect Hot spots, to avoid electrical failures and increase safety for all current-carrying devices. Visual and mechanical inspection to be done when load is applied to the system. Use & follow appropriate caution, safety devices, and personal protective equipment. Provide a report which includes the following, all as specified and directed. 1. Description of equipment tested. 2. Discrepancies if any. (HOT Spots). 3. Identify load conditions at time of inspection. 4. Provide photographs and/or thermo grams.
Supply and applying Si-COAT 570 RTV Silicon High Voltage Insulation Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber (4.5 Kg coating materials per panel) , testing complete all as specified and directed. Make:- CSL Silicones Inc. Canada or equivalent
Supply and applying Si-COAT 570 RTV Silicon High Voltage Insulation Coating solution using an Sprayer to the 11KV Indoor VCB panel Bus bar chamber (4 Kg coating materials per panel) , testing complete all as specified and directed. Make:- CSL Silicones Inc. Canada or equivalent
Note for item Nos. 51.00 & 52.00 :- 1.Surface preparation: All insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating. 2.All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope
M&L for complete checking of trip circuit from transformer marshalling box control panel to relay control panel for ensuring proper functioning of all trippings like buccholz, winding & oil temp, OSR, PRV and OLTC circuit and making necessary repairs (if necessary) of all contacts points, checking of forced air circulation system with rise in oil/winding temp, replacement of necessary relays, contactors complete all as specified and directed.
Supply and fix Schneider Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 to Schneider make 11KV VCB including dismantling taking down unsv one and including testing/checking of all other parameters of relays for proper tripping order all as specified and directed.
Supply and fix Schneider High speed trip relay, type-VAJH, 110V to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one and including testing/checking of all other parameters of relays for proper tripping order all as specified and directed.all as specified and directed.
M&L in replacement of fireball extinguisher with metal stand weight 3 Kg, self activate within 3-5 seconds upon reaching the approximate temperature and extinguish the fire with coverage area of about 140 to 160 Sqft complete all as specified and directed.
M&L for dismantling & taking out exhaust fan 600 mm of any sweep from its mounting position , transportation from building to complaint cell and further transportaion to civil workshop outside ND (V) for re winding of heavy duty 3ph exhaust fan 600 mm sweep after opening complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings / capacitor pad / connector block, connection wire 3 core, assemble of rotor and stator unit with capacitor, connecting wire, capacitor pad, down rod, blades complete all as specified and directed.
Material & labour for preparation of surfaces by scrapping and removing old painted surface with wire brush and applying white wash to wall/coping/Plinth protection area, Earth pits of MRS bldg/GIS bldg complete at alternate 60 days all as specified and directed by Engr-in-Charge.
M&L for servicing of exhaust fan heavy duty 450 mm sweep in situ after dismanting taking down from its mounting position on wall at height 3 mtr to 9 mtr from floor, complete cleaning of fan, greasing/oiling of bearing and bushings, replacement of unsv capacitor, damaged bearings, connection wires, tightening of nuts, bolts, washers, Checking for serviceability of all mounting brackets, foundation bolts and refixing to original position with required new rubber bushings / mounting bolts complete all as specified and directed.
M&L for applying Si-COAT 570RTV silicon high voltage insulation coating solution using by special sprayer to the 132KV all insulators for protecting high voltage Arc and discharge including testing complete all as specified and directed. Make : CSL Silicones Inc. Canada or equivalent
UV POWER TECH
M/S CHANDRA ENGINEERS AND CONTRACTORS
Jessica Engineering Works
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .