Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical responsive |
| 2 | Accepted-Technical | Accepted-Technical responsive |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
10 Mar 2026, 4:00 pmClosed
Superintending Engineer(civil)
new power house jodhpur
Roof treatment work and tin shed at NPH premises, Jodhpur discom, Jodhpur
2026_JdVVN_537616_4
NIT 25/2025-26
Open Tender
Civil Works
Percentage
150 days
Jodhpur
Tender Fee, Processing Fee, EMD, Registration copy, GST, IT, PF registration
2 documents required · 2 mandatory
₹1,180
MD RISL
₹32,000
Yes
6 Apr 2026
26 Feb 2026
12 Mar 2026
26 Feb 2026
10 Mar 2026
26 Feb 2026
Dismantling tile work in floors and roofs laid in cement mortor including stacking of serviceable material and disposal of unserviceable material within 50 meter lead :For thickness of tiles 10 mm to 25 mm.(B-159/14.23.1)
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead(B-162/14.55)
Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).(B-55/3.2.4)
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.(B-98/9.3.1)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m2(B-105/10.1.1)
S&F white ashlar stone machine cut Kangura as per approved design 5 cm to 7 cm thick and top portion half round up to 10-12 cm height. Both machine cut finished including excavation of earth work and fixing in cement sand mortar 1:6 as per direction of Engineer incharge complete in all respect size 35 cm wide 5/7 cm thick with all taxes.B-80/6.77
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24)
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Deep groove pointing (B-143/12.31.3)
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25mm thick (B-139/12.3.1)
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 30 mm thick . Commercial Veneer both side (B-93/8.13.2.1)
Providing & applying one coat of UV resistant polymer cement based waterproofing slurry coating of approved make and quality on concrete or plastered surface as per specifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemical with 2 parts of cement and 2 parts of water (covering area 1.86 Sq.M/Kg of chemical) including cost of cement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge.Note: Undulations/cracks found on the surface should be rectified with Cement Motor before application and the same will be paid under relavent item (B-15.30)
Repair to damaged plaster with high performance curing free, quick setting cement mortar & confirming to ASTM C 1600 in ratio of 1:4 with following properties of cement : Compressive strength of 20 MPa within 4 Hours, Curing free, bond strength of 4 MPa within 24 Hours, Non shrink & Non toxic in following steps-i Chopping loose and cracked plaster to required depth, cleaning the exposed surface with wire brush, cleaning of plaster surface with water as necessary and getting dried. ii Plastering the surface with above mentioned high performance cement sand mortar 1:4 upto depth of 25 mm complete with all scaffolding.iii No curing has to be done as the high performance cement used should be curing free. (This item is to be used in only emergency situation after decided by Engineer in charge ) B-17.50
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). B-12.41.1
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (B-146/ 12.46.1)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer.B-144/12.37.1
Old work (one or more coats) including scrapping surface and necessary repairs.Same colour B-144/12.37.2
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) B-12.22.1
Providing and fixing Drapery rod shall be made of 20 gauge cold rolled steel strip, which is electrical resistance welded. The section will be available 25.4 mm diameter the section shall be coated with acid resistance polymer finish shall made from ABS material in nearest matching colour of rod. The ring shall be made from ABS material in nearest matching colour to rod. Brackets made of galvanized steel. b-16.14
Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. B-95/8.26
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). (B-86/ 7.12)
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). (B-86/ 7.13)
P & F WVC wsh basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S. : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall. : Size 510 mm x 440mm (S-221/1.36.2)
P&F looking mirror of PVC frame of appd make ( Atul or eq ) size 500x400 mm (S-241/1.45.1)
Const of CC chamber 125 mm dia on with stainless steel grating ( S-283/ 3.38.4 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)15 mm nominalS-240/2.37.1
(b) 25 mm nominal bore (S-240/2.37.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).15 mm nominal sizeS-2.39.1
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make. Brass 400 grm. 15 mm nominal bore (S-232/2.7.1)
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make.C.P. Brass bib cock,15mm nominal bore. (S-232/2.7.3)
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make. -do- Long body, 15 mm nominal bore weight not less than 690 gm.B628(S-232/2.7.4)
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked).(S-233/2.12.1)
P & F Ball Cock ( IS : 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. 400 gm., 15mm. (S-232/2.11.1)
P & F Full-way Value (IS: 778 Mark) or wheel valve of approved make.Gun - metal 25 mm nominal bore(S-233/2.15.3)
Gun - metal 15 mm nominal bore.(S-233/2.15.1)
P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 ltr. capacity (S-257/2.26.3)
P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make (A)110 mm dia (S-285/3.44.2)
(B) 75 mm dia (S-285/3.44.1)
P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make (S-47/3.46)100 mm dia cowel (S-287/ 3.46.30)
110 mm dia Tee with door ( S-286/3.46.17)ii
110 mm dia bend (S-286/3.46.4 ii)
110 mm dia shoe coupler (S-286/3.46.1 ii)
P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor.(S-217/1.3)
P&F water closet seat covers with brass hinges complete Solid PVC [ISI marked] grade-1 white for EWC (S-232/1.7.1)
P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS 7231(S-219/1.20.2)
P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (233/2.14.9)
P & F 15 mm. Dia Connection Pipe of approved quality/make: PVC pipe with C.P. Brass nuts upto length. 450 mm. (S-233/2.13.3)
P&F Jet spray for water closet with C.P. copper tube flange of approved make(S-226/1.59)
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSRshort point (upt 3 mtr.)E1.1.1
(B) Medium point (Upto 6.0 Mtr.)E1.1.2
(C) Long point (Upto to 10.0 Mtr.)E1.1.3
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR2x2.5 sq.mm +1X1.5 sq mm (E4.1.7
(B) 2x4.0 sq. mm+1x2.5 sq. mm (E4.1.14)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. On Board(E1.3.1)
Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR(E7.36)
Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Minimum lumen output 4200 lm (E-17.4.1.3)
Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing E- 17.2.2
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.Single pole 6 A to 32 A rating E6.1.1.2
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Four Pole Isolator 40A rating.E 6.2.3.1
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR E- 1.4.2
Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 250 MM sweep (E 15.5.3)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.60 MB
tinshednph.pdf
Tender Documents • 0.78 MB
BOQ_966305.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .