Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-Finance 40 BERIYAN AKAB MAHAL SARAY MAHAL SARAY RAMPUR RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | L1 | Accepted-Finance L1 | |
| 2 | L2₹61.0 L+₹2.2 L (3.66%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹61.0 L
EMD Value
₹61,000
Closing Date
18 Jun 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC RAMPUR
office of the SE EDC RAMPUR
10/2024-25/EDCR Replacement of Jarjer/Damaged wire,Pole,GI wire and other System improvement works under Business Plan 2024-25, EDD-Bilaspur, Rampur
2024_PVVNL_923626_2
10/2024-25 (EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
office of the SE EDC RAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC RAMPUR
₹61,000
10 Jul 2024
11 Jun 2024
18 Jun 2024
11 Jun 2024
18 Jun 2024
11 Jun 2024
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
Jointing Kit (indoor) 3*185sqmm
Jointing Kit (outdoor) 3*185 sqmm
Jointing Kit (indoor) 3*300 sqmm
Jointing Kit (outdoor) 3*300 sqmm
Channel
GI Wire 10 Swg
11 KV X-Arm MS Angle 65x65x6 MM
33 KV X-Arm
PCC Pole 9 Mtr Long
PCC Pole 8.5 Mtr Long
XLPE Cable 3*120 Sqmm
XLPE Cable 3*185 Sqmm
11 KV 3*300 Sqmm XLPE Cable
ACSR Rabbit Conductor
Stay set Complete
Earthing Complete
Polymeric 33 KV Pin Insulator with Pin
Polymeric 33 KV Disc Insulator with fitting
Polymeric 11 KV Pin Insulator with Pin
Polymeric 11 KV Disc Insulator with fitting
old and Damaged STP Pole (kg)(Recived Back Site to Store)
Damaged Relay Set (Recived Back Site to Store)
XLPE Cable (Kg)(Recived Back Site to Store)
AI Scrap (in KG)(Recived Back Site to Store)
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
9 Mtr long PCC Pole
8.5 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
9 Mtr long PCC Pole
8.5 Mtr long PCC Pole
Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs.
fixing of 33 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 33 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Rabbit Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling of Damaged STP Pole as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling of Damaged Relay set as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling of Damaged and used XLPE Cable as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling of Damaged and used wire and other material as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 kvXLPE cable 3*120 sq mm with the help of jointing kit as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 kvXLPE cable 3*185 sq mm with the help of jointing kit as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 kvXLPE cable 3*300 sq mm with the help of jointing kit as per RESPO Norms and as per direction of Supervising Engineer.
Providing and fixing 11 KV VCB Relay per RESPO Norms and as per direction of Supervising Engineer
laying and drilling of under ground cable as per direction of Supervising Engineer
Providing and laying and fixing singhle core wire 2.5 mm Dif color (mtr) per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing earth strip 50 mm per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing pipe earthing with cooper wire RESPO Norms and as per direction of Supervising Engineer
Providing and fixingF-Bracket with nut bolt per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing I Hook per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Stone Pad per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Holding Clamp with Nut Bolts for X-Arm RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Clamp with Nut Bolts RESPO Norms and as per direction of Supervising Engineer
M/S MEGHA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .