Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-Finance | L1 | Accepted-Finance L1 bidder | |
| 2 | L2₹44.7 L+₹2.3 L (5.36%)Rejected-Finance REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.8 L+₹4.4 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹47.7 L+₹5.3 L (12.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹53.4 L+₹11.0 L (26.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
12 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Provn of visitor lounge with attached toilet and kitchen at 17 FBSU under GE AF Trivandrum
2024_MES_657878_1
CWE(AF)/TVM/82513 E8 Visitor lounge at 17 FBSU Trivandrum
Open Tender
Construction Works
Lump-sum
180 days
Trivandrum
Class D category a(i)
5 documents required · 5 mandatory
₹500
GE AF Trivandrum
₹87,000
Yes
1 Oct 2024
5 Jun 2024
15 Jul 2024
5 Jun 2024
12 Jul 2024
28 Jun 2024
5 Jun 2024 - 12 Jun 2024
Amount
Sch 'A' Part- I - BUILDING/ STRUCTURES (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
M&L forDesign and onstruction of RCC framed Single storey building including foundation to permanent specification with ACC block masonry,Anti-termite treatment,RCC roof slab with PU based water proofing treatment,UPVC doors, window,ventilators, vitrified tiles flooring, finishing complete all as specified complete all as specified and shown on drawings. Note : - (i)The contractor should design the super structure and foundation according to the soil report and structural drawings of the same shall be submitted after vetted from Govt engineering college / NIT along with design calculation sheet. (ii) The visitors lounge shall be desinged and built according to the architechtural drawings along with schedule of finishes. (iv) Detailed yard stick along all connected documents shall be submitted before execution of the work for approval of accepting officer. Quoted rates are deemed to be included for all these provisions (v) For pricing of deviation if any during currency of contract, the percentage applicable over SSR rate 2020 is fixed as 15 % for building portion only.
GENERAL SUMMARY (Note : Schedule 'A' Part II to IX are prepriced by MES under Ser No. 2 to 8.Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only)
Total of Schedule ‘A’ Part II “INTERNAL ELECTRIFICATION ”
Total of Schedule ‘A’ Part III “FALSE CEILING ”
Total of Schedule ‘A’ Part IV “PATH/ HARD STANDING”
Total of Schedule ‘A’ Part V “SEWAGE DISPOSAL”
Total of Schedule ‘A’ Part VI “ LIGHTENING PROTECTION”
Total of Schedule ‘A’ Part VII “ COOLING APPLIANCES”
Total of Schedule ‘A’ Part VIII “ AIR CONDITIONING”
Total of Schedule ‘A’ Part IX “INTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part X “EXTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part XI “EXTERNAL ELECTRIC SUPPLY”
Sch 'A' Part- XII - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep BEE star rated suitable for wall mounting complete all as speicified and directed.
Supply and fixing LED luminaire 300 mm x 300 mm, 24 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as speicified and directed.
Supply and fix LED Bollard light of 8/10 watt IP65 with pressure die cast powder coated housing with diffuser on PCC foundation of size 30cmx30cmx50cm with GI/stainless steel nut bolt complete all as speicified and directed. Note : " Cost of excavation and earthwork for PCC foundation deemed to be included in the quoted rates"
Supply and fix LED Flood light 150 W IP 65 with necessary fixing accessories complete all as speicified and directed.
Supply and lay UPVC Pipe of outside diameter 32mm dia class 5,10 Kgf/cm2 , ISI marked complete with all fittings all as specified and directed.
M&L for cutting the existing PVC/UPVC/ASTM pipe line in position and inserting UPVC Tee of size 63x63x32 mm and one number union of 32 mm dia for making branch connection all as specified and directed.
Construction of valve chamber of size 600mmx600mmx750mm internal size including necessary earth work,excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 4mm thick on 40x40x6mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as specified and as shown on drawings.
Supply installation testing and commissioning of booster pump single phase 0.50 HP, voltage 160-240V, speed 2780RPM, discharge 70-15LPM, pressure tank capacity 24Ltr including inlet and outlet connections PCC foundation all as specified and directed.
S & F single phase, wall mounting type, naturally air cooled indoor type voltage stabilizer of capacity 1.0 KVA for automatic operation; designed for input variation between 130 to 290 Volts and output voltage stabilized to 210 V to 230 V range with over voltage/ under voltage cut off time delay switch complete all as specified and directed.
Supply and fix refrigerator, electric driven, single Phase 230 volts, 50 HZ AC, smart inverter double door, frost free, anti-bacteria filters etc of capacity 310/322 Ltrs , BEE 3/4/5 Star rated complete all as specified and directed
Supply & Fix modular socket 16A with plug top, MCB SP 25 Amps with modular metal flush box and white cover plate with frame all as specified and directed.
S & F single phase, wall mounting type, naturally air cooled indoor type voltage stabilizer of capacity 5.0 KVA for automatic operation; designed for input variation between 170 to 270 Volts and output voltage stabilized to 200 V to 220 V range with over voltage/ under voltage cut off time delay switch complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron wire of 4 sqmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earting test point all as specified or indicated complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funned with wire mesh 15mm bore GI pipe (light grade) forprotection of earth lead conductor all as directed and testing on completion.
M&L for Earthing complete by using GI earth plate electrode 60cm × 60cm × 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using GI earth wire of size 4mm dia sizeby means of bolts, nuts, check nuts and washers etc made of galvanised iron and protected by galvanised iron light grade pipe 15 mm dia bore & 20mm dia galvanised medium grade for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I .
M&L for Earthing complete by using copper earth plate electrode 60cm × 60cm × 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using copper earth strip of size 20mmx3mm by means of bolts, nuts, check nuts and washers etc made of brass/statinless steel and protected by galvanised iron light grade pipe of 40 mm bore & 20mm dia galvanised medium grade for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I .
DEFT GROUP ELECTROMECHANICAL
ARCHITRAVE CONSTRUCTIONS
Archana Transport
Dhanyaconstructions
G ANILKUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .