| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.3 L+₹3.9 L (16.2%)Rejected-Finance 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹30.5 L+₹6.1 L (25.0%)Rejected-Finance 368 MAHESHPUR OPPOSITE GOVT PRIMARY SCHOOL SECTOR 21 PANCHKULA 134112 HR | PANCHKULA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandigarh
GE Chandigarh N Area Pin-160003
PERIODICAL SERVICES AND CERTAIN MAINT REPAIR TO OFFICE AND MESSES, CE CZ, GE (CTL) AND GE CHD UNDER GE CHANDIGARH
2024_MES_662837_1
GE/CHD-28/2024-25
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class E category a(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹50,000
Yes
30 Oct 2024
29 Jun 2024
5 Sept 2024
29 Jun 2024
3 Sept 2024
13 Jul 2024
29 Jun 2024 - 5 Jul 2024
Amount
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F Tubes 15 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
S&F Tubes 20 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Fixing only tubes, any grade, to walls and ceilings or laying in floors 20 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Fixing only tubes, any grade, to walls and ceilings or laying in floors 15 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs Complete.
Disconnecting existing tanks exc 250 ltr and n exc 500 ltrs in capacity for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc and reconnecting and re-fixing in position complete all as specified and as directed.
Dismantling of PVC (SWR) Pipes of any size and description fixed in wall , jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, MS flat iron screw bolt fixed to wall complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes PVC (SWR) bends any radius complete all as specified and directed
Taking down chowkhats or frames not exc. 1.5 sq. m each( without taking off shutters from the frames) complete all as specified.
Taking down shutter of any description exc 1 sq.m but n exc 2.00 sq.m and refixing in same opening after minor adujusting complete all as specified and directed
Taking down window chowkhats or frames exc 1.5 sq. m but n exc 4 sq. meach any description exc 1.5 sq.m but n exc 4.00 sq.m complete all as specified and directed
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm with single side prelam PVC sheet plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F factorymade Solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face with wood free EPS, supplying & fixing in frame at site as per specification & drawing
S&F for 100mm butt hinges medium weight,cold rolled mild steel all as per specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long all as specified and directed.
S&F 125 mm long extruded section aluminium alloy anodised handles fabricated type all as specified and directed.
Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises for minor repairs to floor in patches all as specified and directed.
M&L for Non skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm laid as in floors/skirting, set and jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with coloured cement to match with surfaces of tiles complete all as specified.
M&L for Non skid Ceramic coloured tiles 8 to 9 mm thick (square/ rectangular) area of each tile exceeding 0.18sqm but not exc 0.36sqm laid as in floors/skirting, set and jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with coloured cement to match with surfaces of tiles complete all as specified.
M & L Glazed ceramic digital coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match . The tiles shall be laid in pattern with two or more colured tile including rendering 10 mm thick on brickwork or concrete surfaces finished even and fair in CM 1:4.combinations all in any pattern and shade/colour as directed by Engr-In-charge.
M&L vitrified Ceramic tiles 600mmx600mmx8 mm to 9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match inlcuding screed bed of 15 mm thick CM 1:6 complete all as specified and directed complete all as specified and in any pattern and shade/colour as complete all as specified directed by Engr-In-charge.
M&L for 16 to 18mm thick green marble machine cut stone slab (table rubbed polished) as in cooking platform , jamb, cill, step & riser setted and jointed with cement slurry and bedded over & including cement sand mortar (1:4), & pointed with white/ coloured cement including cutting ,grinding, rounded and chamfered edges and granite polishing etc complete all as specified and as directed.
M&L for 16 to 18mm thick black granite machine cut stone slab (table rubbed polished) as in cooking platform , jamb, cill, step & riser setted and jointed with cement slurry and bedded over & including cement sand mortar (1:4), & pointed with white/ coloured cement including cutting , rounded and chamfered edges and complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified.
M&L for PCC (1:4:8 ) type D-2 using 20 mm graded crushed stone aggregate as in sub base laid in floor and finishing the top surfaces even and fair complete all as specified.
Supply & fix in repairs vitreous china wash down water closet pan (pedestal pattern) white including plastic water closet sheet cover white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hanging device and including mild steel chromium plated jet fixed to water closet complete all as specified and directed.
M&L for ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed to 20 mm bore fixed in repair complete all as specified and directed.
S&F in repair 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracketsPVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets fixed in repair complete all as specified.
M&L for Vitreous china oval shape wash hand basin white size 560x470mm to be fitted in granite shelf /RCC slab including 32 mm dia CP waste coupling and 60cm waste pipe complete all as specified. Make: Cat part S2030103 of Cera, Parryware, Jaquar
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including fixing bracket waste coupling and waste pipe complete all as specifeid and directed.
S&F 15 mm bore pillar taps fixed in repair cast copper alloy, fancy type with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe including spendel spray flushing pipe ad connection to flushing pipe complete all as specified
S&F for one piece PVC hydraulic plastic water closet seat cover (white coloured) closed pattern with flat bottom, cover and mild steel chromium plated or aluminium hinges device for pedestal pan fixed as in repair complete all as specified and as directed.
S&F single piece WC of size 365x655x765 with flushing cistern and connection pipe, P or S trap (closed pattern incl all necessary accessories like rag bolts, kitt /gel gasket etc, (including flushing cistern, pvc seat cover , jet and flush pipe including P or S trap, complete all as specifed and directed. Make : Jaquar cat part no LYC-WHT-38851S, Cera, Parryware.
S&F PVC (SWR) pipe 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors ,complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends with/without door access any radius, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends with/without door access any radius, complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore, including jointing to waste pipe set in cement concrete type B-1(1:2:4), IN REPAIR, complete all as specified.
Dismantling of cast iron pipe dia 100/75/50mm, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F factory made box type steel windows / ventilators with side hung shutters including hinges, steel handle, steel peg stay and MS tower bolt 150mm long complete with glazing bars , dovetailed or welded cutting holes in brick wall in mud/cement mortar for inserting holdfasts PCC and making good as per Drg No TD-277R sheet 1/4 to 4/4 of HQ CE CZ Chandigarh complete all as specified and directed.
S&F factory made box type steel windows / ventilators with side hung shutters including hinges, steel handle, steel peg stay and MS tower bolt 150mm long complete without glazing bars , dovetailed or welded cutting holes in brick wall in mud/cement mortar for inserting holdfasts PCC and making good as per drawing No TD-276R sheet 1/4 to 4/4 of HQ CE CZ Chandigarh complete all as specified and directed.
S&F steel ventilator (box type ) with top hung shutter including hinges, steel peg tower bolt complete all as specified.
S&F 4mm plain glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as speciifed and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified.
S&F as in repair mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
M&L brickwork with subclass ‘B’ bricks, class Designation 10 straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as specified.
Brick work with sub class 'B' bricks, class Designation 10 straight or curved on plan exc 6m mean radius built in cement mortar 1:6 EXCEPT BRICKS complete all as specified and as directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed.
M&L for rendering 10mm thick cement plaster on brick work or concrete surfaces including roof projections and chajjas of buliding upto 10 mtr height building in cement mortar (1:3) on ceiling finished even and smooth without using extra cement including taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed.
M&L for rendering 15 mm thick cement plaster on brick work or concrete surfaces in cement mortar (1:4) finished fair using water proofing compound all as specified and directed. Note: Water proofing compound will be paid seprately.
M&L for rendering 15 mm thick cement plaster on brick work or concrete surfaces in cement mortar (1:6) finished even and fair including taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed.
M&L two coats of white wash on walls on newly plastered surfaces including prepraration of surfaces complete all as specified.
M&L two coats of cement base paint on walls on newly plastered surfaces including prepartion of surfaces, alkali resistant priming coat complete all as specified and directed.
M&L three coats of white wash on ceiling on newly plastered surfaces including prepraration of surfaces complete all as specified.
M&L for applying of one coat of oil bound distemper (Ist quality) over and including a coat of primer on wall surfaces prepared by wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment applying of two coat of oil bound distemper (Ist quality) over a coat of primer on wall surfaces prepared by wall care putty complete all as specified and as directed.
M&L complete removal of existing treatment of ceiling surface and applying one coat of white wash , complete all as specified.
M&L for applying one coat of white wash on wall surface, including preparation cleaning of surfaces, complete all as specified.
M&L for applying one coat of cement base paint on old wall surfaces including prepration of walls & surface complete all as specified & as directed.
M&L for complete removal of existing treatment and applying two coat of weather coat internal/externel wall surface over a coat of primer of damp shealth including properly filling the cracks with putty complete all as specified.
M&L for prepration of old steel and iron surfaces and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and directed.
M&L for prepration of old wood and wood base surfaces and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and directed.
M&L for two coat of synthetic enamel paint over one coat of red oxide on new steel Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed.
Demolition of cement plaster, loose concrete pointing, old loose foreign particles, old APP, vagetation with roots if any and cleaning the surface with wire brushes for removing caked mud and loose foreign particles etc, sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc complete all as specified & directed.
M&L for rendering 15mm thick in cement plaster (1:4) mixed with liquid water proofing compound as manufactures instruction on brick/ concrete surfaces finished even and fair complete all as specified and directed.
M&L for appliying bitumenous primer @ 0.30 litre per sqm over cleaned and dry roof surface including parapet. (b) M&L for providing and laying 3mm thick APP modified polymer reinforced water proofing membrane with minimum weight of 3.60kg/sqm as specified. The APP membrane shall be laid using torch application with minimum 10cm side overlap and 15cm end overlap. The APP memberane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet complete all as specified and as directed.
M&L for 300mmX300mmX 7 to 8mm thick cool roof/ temp shields tile as in terraces, roofs pavment as in horizontal and slant and stair vertical surface white in colour set and jointed in neet cement slury and pointed in white or colour of tile over and including screed bed or beding layer 15mm cement mortar (1:6) complete all as specified and directed.
M&L for providing cement concrete PCC 1:2:4( Type B-0) using 12.5 mm graded aggregate as in fillets and holdfast complete all as specified and as directedcomplete all as specified and directed.
Demolition of lime concrete of any description and in any thickness, any position not otherwise specifically provided for including chaina mozaic etc. complete all as specified.
Supply only liquid water proofing compound complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specially provided for sunken floor complete all as specified and directed.
M&L RCC for 1:1.5:3 (Nominal mix) using 20 mm graded aggregate in foundations, including rafts, footings, slab for shelf, beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete including formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work including demolition of reinforced concrete of any description and in any position complete all as specfied and directed
M&L for TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified.
Mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
S&F PVC waste pipe 800 mm long suitable for 32 mm dia waste coupling, IN REPAIR, complete all as specified.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, chromium plated fancy type, short body with wall flange screwed down, suitable for 15 mm bore pipe, IN REPAIR complete all as specified.
S&F for stop valves/angle valve, fancy type, chromium plated 15mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified.
Dismantling of walls and ceiling boards/wall paneling or insulation board any thickness, including cover fillets complete all as specified and directed
S&F PVC hallow wall panelling of 5mm thick panels including all necessary screws and frame work etc completed all as specified by Engr-in - Charge.
M&L for providing and fixing Gypsum board panel laminated with texture vinyl coated paper tiles of size 595mmx595mmx10mm thick as in ceiling having snap grid 600mmx600mm including GI wall angle of size 24mmx24mmx0.43mm thick along with perimeter of ceiling, fixed to walls/ partition with the help of nylon sleeves at 450mm centre to centre, suspending intermediate Tee section of size 24mmx38mmx0.35mm thick and cross Tee-section 24mmx25mmx0.3mm thick suspended from soffit of ceiling at up to 900 mm centre to centre or adjustable as required at site.4mmdia GI wire hangers fixed/tightened with ceiling with the help of nylon sleeve/rawl plugs complete all fittings including dismantling of walls and ceiling boards/wall paneling or insulation board any thickness, including cover fillets complete all as specified and directedcomplete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new onescomplete all as specified and directed by Engr-In-Charge.
S&F 5mm thick sheet glass pane tinted type, with 5 micron thick black film ordinary quality and ruber, cleting, silicone,glazing with oil putty etc in each pane complete all as specified and directed.
S&F aluminium powder coated (min thickness of powder coating 50 micron) frame for door , windows, ventilators with one or more rebates including joining cleat/aluminium beading for fixing etc complete all as specified.
S&F aluminium powder coated (min thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section including necessary joining cleats/aluminium beading, glazing clips clips, ruber neoprene packing, handles 2 Nos, tower bolt 2 No in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F aluminium powder coated (min thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars,including (double shutter) glazing bars and without glazing bars aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), tower bolt 2 Nos complete all as specified.
Dismantling plain or corrugated AC sheet or similar pattern roof covering complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or fixed to wall using hold fast including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or fixed to wall using hold fast including dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
S&F Steel tubular section of any size and shape including special shaped washer fixing in any position including cutting, notching, drilling, riveting or welding and connecting with nuts and bolt etc.complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid PVC conduit medium grade ISI marked, conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame , sockets, fan regulator etc for One light/fan point controlled by one way switch complete all as specified. : Note:-1. cable Colour should beas per IS code. 2. Modular switch sockets fan regulators shall be meaured and paid separately udner respective items. 3. Cost of mudular MS box , modular cover plate and frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates.
All as per item No 93 above but one fan point controlled by one switch and one regulator.
All as per item No 93 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 93 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 93 above but one call bell point controlled by one way bell push switch
All as per item No 93 above but one light point controlled by two way switch
M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L for Point wiring complete with 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid PVC conduit medium grade ISI marked, conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall, mild steel Box, 1.6mm thick with 3mm thick plastic laminated sheet as required at site suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way switch complete all as specified. Note : cable Colour should be as per IS code.
All as per item ser No 101 above but point wiring for one fan point
All as per item No 101 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 101 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 101 above but one call bell point controlled by one way bell push switch
All as per item No 101 above but one light point controlled by two way switch
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, bell, regulators sockets etc, and removing from site and making good distribut surfaces of walls, floors etc all as directed.
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
All as per item No 108 here in above but with 2X6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.
All as per Item No 108 here in above but size of 3X2.5 Sqmm.
M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistandard with copper conductor drawn in the existing metal/PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete.
Taking down existing unserviceable sub main wiring 2.5/4/6 Sqmm aluminium cable all as directed.
Supply and fixing switch piano flush type universal single pole one way 5 amps 230 volts.
Supply and Fixing switch socket flush type universal 2 in 1, 3 pin, 5 Amps 230 volts.
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts.
Supply and Fixing switch socket flush type universal 2 in 1, 3/6 pin 15 Amps 230 volts.
Supply and fixing switch piano flush type single pole two way 5 amps 230 volts.
Supply and fixing bell push switch flush type universal single pole 5Amp, 230Volt.
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Supply and Fixing Ding Dong AC 230 volts,single pole.
Supply and Fixing 5/6 Amps bell push one modular switch complete.
Supply & Fixing 5/6 Amps 1 way one modular switch complete.
Supply and Fixing 5/6 Amps three pin socket modular complete.
Supply and Fixing 15/16 Amps one way one modular switch complete.
Supply and Fixing 15/16 Amps three pin socket modular complete.
Supply and Fixing 5 Amps 2 way modular switch complete.
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed.
Disconnection and removing the u/s LED lamp and S&F LED lamp 9 watts complete all as spfd and directed.
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete.
S&F MCB DB, SPN, 2 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
S&F MCB DB, SPN, 8 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
S&F MCB DB, SPN, 12 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge
S&F MCB DB, TPN, 4 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge
S&F MCB DB, TPN, 6 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge
S&F MCB DB, TPN, 8 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge
S&F MCB DB, TPN, 12 way with 200 Amps 240 Volt rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed by Engr - in -Charge
Taking down existing unserviceable MCB DP/TPN along with MCBs complete by disconnecting all as directed.
S&F MCB SP of capacity 6-30 Amps 230 volts 10 KA ISI marked.
All as per Item No 139 here in above but of capacity MCB DP 40 Amps
All as per Item No 139 here in above but of capacity MCB DP 63 Amps
All as per Item No 139 here in above but of capacity MCB SPN 63 Amps
All as per Item No 139 here in above but of capacity MCB TPN 32 Amps
All as per Item No 139 here in above but of capacity MCB TPN 40 Amps
All as per Item No 139 here in above but of capacity MCB TPN 63 Amps
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X18/20 watts LED, 230Volt energy saving recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X18/20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 20W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X9/12 watts LED, 230Volt energy saving,recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X10 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x10W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F surface mounting mirror light luminaire 10 watts LED, 230Volt energy saving accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting from the fall ceiling carefully and S&F LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
S&F decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s light fitting from the Surface mountend carefully and S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s round down light and S&F Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 22 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Disconnection and removing the u/s square downlight and S&F Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Disconnection and removing the u/s Cob light and S&F Cob Eyeball downlight LED recessed Square Downlight with Superior light output and internal driver 12 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
S&F as in repair batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by engineer-in-charge.
M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface Note : MCCB shall be measured and paid separately
Supply and fix in repair MCCB 4 pole 100 Amps 25 KA complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
All as per Item No 160 here in above but of capacity 4 pole 160 amps, 415 Volt 36 KA.
All as per Item No 160 here in above but of capacity MCCB 3 pole, 125 Amp, 415 Volt 36KA.
All as per Item No 160 here in above but of capacity MCCB 3 pole 100 Amp, 415 Volt 25KA.
All as per Item No 160 here in above but of capacity MCCB 3 pole 63 Amp, 415 Volt 25KA.
Disconnection & taking down the unserviceable building light high wattage (30/25 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte all as specified and directed.
Disconnection & taking down the unserviceable GI bracket of size 32 mm dia from the pole / building and M&L for street light bracket made out of 32 mm dia GI tubing light grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x6mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/building complete all as specified and as directed.
M/s Super Trading Corporation (BID ID -3071320)
FIRE ENVO SAFETY ENGINEERS (BID ID -3074405)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .