| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.7 L+₹68,450 (8.49%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹9.2 L+₹1.2 L (14.5%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹9.5 L+₹1.4 L (17.6%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹9.7 L+₹1.7 L (20.8%)Rejected-Finance 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | SONI ENTERPRISES L5 | M/S BHATT ENTERPRISES L4 | om enterprises L1 | RAMSONS DEVELOPERS L2 | JAGAT POWER ELCTRICAL L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all ss specified and directed. | 5 | Each job | 500 ₹2,500 | 320 ₹1,600 | 350 ₹1,750 | 4,100 ₹20,500 | 100 ₹500 Lowest |
| 2.00S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- (Note :-Make of MCCB/MCB : Schneider/L&T/ABB) | ||||||||
| 2.01 | (a) MCCB 4 Pole 63 amps rating, 16 KA breaking capacity, 415 Volt | 1 | Each | 4,500 ₹4,500 | 4,500 ₹4,500 | 3,700 ₹3,700 | 4,500 ₹4,500 | 2,500 ₹2,500 Lowest |
| 2.02 | (b) MCCB 4pole 100 amps rating, 16 KA breaking capacity with spreader at bothe side | 1 | Each | 7,000 ₹7,000 | 5,600 ₹5,600 | 3,800 ₹3,800 | 6,500 ₹6,500 | 2,500 ₹2,500 Lowest |
| 2.03 | (c) MCCB 4 pole150/160 amps rating, 36 KA breaking capacity with spreader at bothe side | 1 | Each | 9,000 ₹9,000 | 8,700 ₹8,700 | 9,000 ₹9,000 | 7,500 ₹7,500 Lowest | 8,000 ₹8,000 |
| 2.04 | (d) MCCB 4 pole 200 amps rating, 36 KA breaking capacity with spreader at bothe side | 1 | Each | 14,500 ₹14,500 | 12,500 ₹12,500 | 1,150 ₹1,150 Lowest | 8,500 ₹8,500 | 9,000 ₹9,000 |
| 2.05 | (e) MCCB 4 pole 250 amps rating, 36 KA breaking capacity with spreader at both side . | 1 | Each | 18,500 ₹18,500 | 13,250 ₹13,250 | 12,000 ₹12,000 | 10,500 ₹10,500 | 10,000 ₹10,000 Lowest |
| 2.06 | (f) MCCB 4 pole 400 amps rating, 36 KA breaking capacity with spreader at bothe side | 1 | Each | 23,200 ₹23,200 | 16,590 ₹16,590 | 13,000 ₹13,000 | 15,550 ₹15,550 | 12,000 ₹12,000 Lowest |
| 2.07 | (g) Volt meter (0 to 500 volts) anolog type with selector switch for three phase . | 1 | Each set | 900 ₹900 | 1,300 ₹1,300 | 450 ₹450 | 3,500 ₹3,500 | 100 ₹100 Lowest |
| 2.08 | (h) Amp meter (0 to 500 amps) anolog type, witch selector switch for three phase measurement . | 1 | Each set | 900 ₹900 | 1,299 ₹1,299 | 460 ₹460 | 3,500 ₹3,500 | 100 ₹100 Lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
15 Jul 2025, 6:00 pmClosed
AGE Indep AF Bhowali
AGE Indep AF Bhowali PO Bhowali UK 263132
REPAIR/MAINT OF SERVO STABLIZER, LT PANEL,MCCBs, LT CABLE FOR MES COMPLEX AND ADM SITE AF STATION BHOWALI.
2025_MES_715326_1
8012/E8
Open Tender
Civil Works
Item Rate
180 days
AF Stn Bhowali
As per NIT
8 documents required · 8 mandatory
₹500
AGE Indep AF Bhowali
₹19,800
Yes
19 Sept 2025
18 Jun 2025
17 Jul 2025
18 Jun 2025
15 Jul 2025
3 Jul 2025
18 Jun 2025 - 8 Jul 2025
Amount
Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all ss specified and directed.
S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- (Note :-Make of MCCB/MCB : Schneider/L&T/ABB)
(a) MCCB 4 Pole 63 amps rating, 16 KA breaking capacity, 415 Volt
(b) MCCB 4pole 100 amps rating, 16 KA breaking capacity with spreader at bothe side
(c) MCCB 4 pole150/160 amps rating, 36 KA breaking capacity with spreader at bothe side
(d) MCCB 4 pole 200 amps rating, 36 KA breaking capacity with spreader at bothe side
(e) MCCB 4 pole 250 amps rating, 36 KA breaking capacity with spreader at both side .
(f) MCCB 4 pole 400 amps rating, 36 KA breaking capacity with spreader at bothe side
(j) CTs of existing ratio and capacity fixed in LT panels and connect with ammeter .
(k) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
(l) MCB TPN 63 amps, 'C' series, 415 volt
M&L for boring under road horizontely of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed.
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately)
(a) 240 Sqmm 3.5 core
(b) 16 Sqmm 4 core
(c) 70 Sqmm 3.5 core
Excavation in trenches in hard/dense soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat.
M&L(in replacement) for laying of GI Pipe medium grade of 50 mm bore dia in trenches /under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and as directed by Engineer-in-Charge
Servicing/overhauling of servo voltage stablizers of ranging from 30 KVA to 150 KVA capacity , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components after drawout of coil if required and Testing for smooth operation after caliberation of relay trough OEM of servo/ and resetting the system & setting for healthy system, complete all as specified and directed by Engr-in-Charge. Note: Worn out parts shall be deemed to be included in quoted rate and Major parts shall be measured and paid separately are as under:
Supply only spare parts for servo stablizers of any make (30 - 150 KVA) all as specified :-
Digital control card of servo as per existing make.
R C network of servo complete all as required and directed at site complete all as per sample.
Servo motor complete all as required and directed at site complete all as per sample.
Micro switches complete all as required and directed at site complete all as per sample.
Voltage regulating coil complete all as required and directed at site complete all as per sample.
M&L Servo stablizer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Supply and fixing of 30HP Soft Starter with Wall Mounting Panel consist of following items as under : 1. MCB 4P 100 A -01 2. Soft starter, Altistart 480, 45 A, 208 to 690V AC, control supply 110 to 230V AC -01, 3.Contactor 65 A 4. Push Button and Indicator 5. MS Powder Coated Complete wired up Starter Panel Approx HWD 600*600*300 - 01
Supply and fixing in replacement of sheet metal encloser of 100 Amps capacity
Supply and fixing in replacement of sheet metal encloser of 63 Amps capacity
Material and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 20x3mm size (upto 7.5 metre from ground electrode) by means of copper/brass bolts, nuts, check nuts and washers all as shown in electrical plate No.3 of MES Schedule Part-I, connected to earth test terminal block and testing on completion with and including 40mm bore light grade GI protection pipe for strip upto plingth protection, PCC pit in mix 1:3:6 type C1, with RCC 1:2:4 type B-1, 40 mm thick cover, reinforced with 6 mm dia MS bars 3Nos. both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as specified and directed at site
RAMSONS DEVELOPERS (BID ID -3351742)
JAGAT POWER ELCTRICAL (BID ID -3359485)
M/S BHATT ENTERPRISES (BID ID -3359449)
SONI ENTERPRISES (BID ID -3351148)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .