AGE I RnD Haldwani
AGE I RnD Haldwani PO Arjunpur UK 263139
REPAIR AND MAINT OF INTERNAL ELECTRIC SUPPLY, REWIRING/REPAIR AND SERVICING OF CEILING FAN, GEYSER, DESERT COOLER, WATER COOLER, ACS AND ATTENDING DAY TO DAY COMPLAINTS INCL STREET / GARDEN LIGHT AND MISC E/M WORKS AT DIBER HALDWANI
2022_MES_548423_1
AGE I RnD / HLD /16 OF 2022-2023
Open Tender
Civil Works
Item Rate
334 days
DIBER HALDWANI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RnD Haldwani
₹12,000
Yes
21 Nov 2022
29 Aug 2022
26 Sept 2022
29 Aug 2022
24 Sept 2022
12 Sept 2022
29 Aug 2022 - 16 Sept 2022
Amount
Disconnecting, dismantling and taking out the existing unserviceable items of any description, any make and in any position and refixing new items shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’,Item 1, disconnecting, dismantling/testing charge is deemed to be included under the unit rate quoted by the contractor for this item complete all as specified and directed.
S&F switch piano, flush type, single pole one way 5 amps complete all as specified and as directed
S&F socket out let 2 in 1, 3 pin 5A, flush type complete all as specified
S&F switch piano, flush type, single pole one way 15 amps complete all as specified and as directed
S&F socket out let 2 in 1, 5 pin 5A and 15 Amp , flush type complete all as specified
S&F ceiling rose 3 phaser VC/polycarbonate, isolated body complete all as specified
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fitting isolated body complete all as specified
S&F Ceiling Fan Regulator dimmer type( small normal) deluxe 240V 50 Hz step type.
S&F Ceiling Fan Regulator dimmer type( modular type) deluxe 240V 50 Hz step type.
S&F Capacitor for ceiling fan 2.5 MFD copper wired Make:- L&T/Havells/CG/Anchor/
S&F Top plug 3 pinl 6 Amp Make:- L&T/Havells/CG/Anchor/
S&F Top plug 3 pinl 16 Amp Make:- L&T/Havells/CG/Anchor/
S&F Modular switch 1 way 6 Amp 1 Module complete all as specified and directed. Make:- L&T/SSK/Havells/CG/Anchor.
S&F modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed Make:- L&T/SSK/Havells/CG/Anchor.
S&F Modular Socket 1 way 16 Amp 1 Module complete all as specified and directed. Make:- L&T/SSK/Havells/CG/Anchor.
S&F Modular switch 1 way 16 Amp 1 Module complete all as specified and directed. Make:- L&T/SSK/Havells/CG/Anchor.
S&F Modular cover/combined plate 1module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular cover/combined plate 2module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 3module Make:- L&T/SSK/Havells/CG/Cona.
S&F Modular combined plate 4module Make:- L&T/SSK/Havells/CG/Cona.
S&F Switch Socket combined 2 in 1, 5 pin 16 Amp Universal.Make:- L&T/SSK/Havells/CG/Cona.
S&F Flash metal GI box 1/2module Make:- L&Tequivalent
S&F Metal plug Top 32 Amp 3 pin Make:- L&T and equivalent.
S&F Metal plog socket 32 Amp 3 pin Make:- L&T and equivalent .
S&F MCB single pole, 6 to 32 Amps (`C’ series ) having current rating 10 KA complete all as specified and directed.Make : L&Tand equivalent
S&F ditto as items No 1.24 but MCB single pole, 40 Amps
S&F ditto as items No 1.24 but MCB double pole, 6 to 32 Amps
S&F ditto as items No 1.24 MCB double pole 40 Amps
S&F ditto as items No 1.24 MCB double pole 63 Amps
S&F ditto as items No 1.24 but MCB triple pole 40 Amps to 60 Amp
S&F in replacement Copper conductor 1.5 sqmm 3 core Make:- L&T/Havells/Plaza/Anchor
S&F replacement Copper conductor 2.5 sqmm 3 core rounded Make:- L&T/Havells/Plaza/Anchor
S&F replacement Copper conductor .75 sq mmFlexible twin twisted Make:- L&T/Havells/Plaza/Anchor
S&F replacement LED adore 9 watt 3 star lamp Crompton/Havells/C&S/Philips
S&F replacement LED adore 10 watt 3 star lamp Crompton/Havells/C&S/Philips
S&F in replacement inverter LED batten with square profile and polycarbonate channel, lithium ion battery with charging time 8-10 hrs and back up upto 4 hrs.Model- (PRIDE PLUS INVERTER BATTEN. CatPart No-LHEXACP7FN1W010) 10 watt led 6500 K.complete all as directed by Engr-in-Charge.
Taking down old unserviceable tube light fitting of any make or size and supply and fixing 20 watt 4 ft surface mounted decorative E-LITE LED PRIDE PLUS NEO NXT ultra slim Led batten of make Havells.20 W LED 6500 K. Cat Part NO- LHEXAQP7PN1WO20 Havell.
S&F in replacement of LED Surface mounted 1x4 Flat Panel with ceilling light LCTLRN-40-SPAN including taking down old unserviceable of any type and make. Make- Crompton Greaves Cat Part No- LCTLRN-40-SPAN all as specified and as directed at site.
S&F in replacement of 12 watt round surface mounted decorative LED of any make or size and fixing TRIM COSOMO ROUND Zero bezel LeD panels with inbuilt driver in PC body. Premium aesthetics with wider light coverage.Make- Havells. Cat Part No- 12 W LeD 6500 KLHEBABP7IZ1W012 all as specified and as directed at site.
Taking down carefully copper/Aluminium point wiring of any type for light,Fan,Socket or power point complete including fittings and fixures such as switches, ceiling rose, pendents, regulators, sockets, light fittings etc. Removing materials to store to keep in safe custody or taking credit (credit for above item should be made as per conditions separately) and making good disturbed surface of wall, floor etc.
M&L Point wiring with multistranded copper conductor PVC Insulated and unsheathed cable in PVC concealed conduit with 1.5 SQMM FRLS cable with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected to common earth with terminal boxes for Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box, for one light/Fan/Exhaust Fan point complete and making good the existing disturbed surface.
Ditto all as per item ser No 7 but 3 pin socket outlet 5 Amp socket point on indipendent board.
Ditto all as per item ser No 7 but 5 Amp socket point on same board.
Ditto - All as per item Srl No 7 above but one bell point controlied by by one bell switch
Ditto - All as per item Srl No 7 above but one light point controlied by by two way switch
M&L Point wiring with multistranded copper conductor PVC Insulated and unsheathed cable in PVC casing caping with 1.5 SQMM FRLS cable with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Moduler/Normal fittings including acessories as metal flush box, for one light/Fan/Exhaust Fan point complete and making good the existing disturbed surface.
Ditto as per item ser No 12 but 5 Amp socket point on indipendent board.
Ditto as per item ser No 12 but 5 Amp socket point on same board.
M&L for Power point wiring of any length as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 2.5 sqmm including earth wire of size 1.5 Sqmm in and including PVC casing caping including MS box suitable of modular fittings ,inner and outer modular top sheet top cover, for one 3/5 pin socket outlet 15 Amps independent all as specified .
Supply and fixing in replacement sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 8way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint all as specified and as directed by the Engr-in-charge.
Supply and fixing in replacement sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 6 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint all as specified and as directed by the Engr-in-charge.
Taking down of submain wiring of any Size and accessories all as directed.
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded 1100V grade heavy duty 2x10 Sqmm (2X10 sq mm +1 X 6 sq mm)complete drawn through existing casing capping or conceale conduite along with 1x6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable for continuous earth wire and duly connected to common earth dolly all as specified and directed (The specified runs of two 10 sqmm and one 6 sq mm run of cable of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length).
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded 1100V grade heavy duty 2 x 4 Sqmm (2 x 4+1 x 2.5 sq mm) complete drawn in existing PVC casing caping on surface/ceiling along with 1 x 2.5 Sqmm PVC insulated unsheathed copper conductor multi stranded cable for continuous earth wire and duly connected to common earth dolly all as specified and directed (The specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length).
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded 1100V grade heavy duty 2x6 Sqmm complete drawn in new PVC casing caping on surface/ceiling along with 1x4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable for continuous earth wire and duly connected to common earth dolly all as specified and directed (The specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length).
M&L for fixing only Casing capping 25 mm in repair where required at site. The casing capping will be measured in RM.
M&L for fixing only Casing capping 32 mm in repair where required at site. The casing capping will be measured in RM.
Disconnecting, dismantling and taking out existing-functional Air conditioner window type of any description, any make and in any position, 1.5/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, and refixing in existing position complete all as specified and directed at site.
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed. NOTE :- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply & fixing ” under appropriate item of Sch ‘A’. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item .
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for Split A/C complete all as specified and directed. Make –carrier
Disconnecting and taking out defective / nonfunctional air filter and Supply & fixing Air filter nylon type suitable for window A/C complete all as specified and directed. Make –carrier
Disconnecting and taking out defective / nonfunctional outdoor fan motor and Supply & fixing fan motor suitable for Split A/C complete all as specified and directed. Make –carrier
Disconnecting and taking out defective / nonfunctional fan motor and Supply & fixing fan motor suitable for window A/C complete all as specified and directed. Make –carrier /voltas
Disconnecting and taking out existing defective / unserviceable remote control assembly with PCB of any description and in any position of any type of split AC & Supplying & fixing new remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG )
Disconnecting and taking out defective / nonfunctional capacitor 60 MFD/4.0 MFDand Supply & fixing capacitor suitable for Split A/C/window A/C complete all as specified and directed.
Disconnecting and taking out defective / nonfunctional relay contactor and Supply & fixing relay contactor suitable for Split A/C complete all as specified and directed.
Taking out defective sealed unit compressor of window type AC of capacity 2 TR of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed.
All as per item No.33 here in above but compressor of 1.5 TR capacity split AC of any make complete all as specified and directed.Note:- Refrigerant Gas required for charging of compressor shall be measured separately under respective item of this Schedule.
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed.
Supply & fix of drain pipe for window/split A/C standard size of 3 meter complete all as specified and directed. Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 25.00 here in above.
Disconnecting, dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts three phase 10 KVA cap. of any make by checking, tightening of electrical connection, replacement of carbon bush/diode/triode/transformer, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. NOTE :-The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’
Circuit plate
Relay
volt meter
Servicing of desert cooler of different size and capacity including cleaning ,greasing, painting of whole body inner and outer ( inner body should be painted by red oxide paint , the joints and corner should be filled by black bituminius paint, the outer body should be painted by sky blue paint,) The minor parts such as nut bolts and washer is deemed in the quated rate and should be tightned and fastned properly.
Taking out & removing old burnt-out windings of Desert cooler fan motor of any description and servicing/rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site and re- assembling the complete, connecting and testing on full load to the entire satisfaction of Engineer-in-charge.
Supply only the following new parts suitable for desert cooler of any capacity. Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 38 here in above.
Supply only new wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply only submersible pump for Desert cooler 230 volts, 45 watt, 1400 RPM, with ball bearings complete all as specified and directed (Make : Crompton / AUE / Khaitan/ Bajaj )
Disconnecting and taking down the existing Geyser of any capacity (25 / 50 Ltrs) and in any position from the existing location and Dismantling the Geyser,Servicing/ cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately
Supply only the following new parts suitable for geyser of capacity 25 /50 ltrs of 2 Kw &1.5 Kw. Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 41 here in above.
Supply only ‘U’ assembly SS of 25 Ltr cap any description and in any position from Geyser and supply and fixing new ‘U” assembly to match with the existing system complete all as specified and directed. Make – Recold / Bajaj,/ Daspass
Supply only Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
Supply only Geyser thermostate of size /shape as per suitable for 25 ltrs cap heavy duty copper material used 230 Volts AC supply. complete all as specified and directed
Supply only Geyser thermostate of size /shape as per suitable for 50 ltr cap heavy duty copper material used 230 Volts AC supply. complete all as specified and directed
Supply only geyser heating element of 2 Kw cap heavy duty copper material used and round cup and triangle cup shape with rubber washer .complete all as specified and directed
Supply only geyser heating element of 1.5 Kw cap heavy duty copper material used and round cup and triangle cup shape with rubber washer .complete all as specified and directed
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations/Tech buildings) for repairs / servicing / overhauling / painting / numbering etc, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction complete all as specified and directed. Note : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.(ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) as apv. by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200/1400 mm sweep
Rewinding of motor of exhaust fans of 250 mm sweep.
Rewinding of motor of exhaust fans of 300 mm sweep.
Rewinding of motor of exhaust fans of 450 mm sweep.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & air circulating fans etc. of any description, any sweep Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No.43 here in above.
Supply only ball bearing No 6200 (Make SKF/NRB/NBC)
Suppl only ball bearing No 6201 (Make SKF/NRB/NBC)
Supply only gun metal bushes of any description and size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape/size.
Note :-(i) The entire work will run for 11 months as indicated in the tender documents. Completion before time shall not be entertained by the accepting officer. Site for the entire work shall be given to the Contractor in piecemeal manner and as per user requirement. The Contractor or his rep will report to the Engineer-in –Charge/JE Concerned on day to day basis to received the urgent nature of works and execute the same day to day basis. Non attending/reporting/execution of such nature of works in piecemeal manner a penalty of Rs. 200 per day shall be levied to the contractor. The rates quoted by the Contractor shall be included in the respective item of BOQ. No extra payment shall be admissible to the contractor on this account. (ii) Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract”.
M/S BHATT ENTERPRISES
AJA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .