Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹6.9 L+₹68,053 (10.9%)Rejected-Finance VILL PO PIRUMADARA TEH RAMNAGAR DISTT NAINITAL UK | RAMNAGAR | NAINITAL | UTTARAKHAND | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹7.6 L+₹1.4 L (22.3%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹7.7 L+₹1.5 L (24.0%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L4 | Rejected-Finance 4TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR MAINTANANCE OF SUMMER APPLIANCES REFRIGERATERS AND AC AT RTS AND DEPOT HEMPUR UNDER GE EAST BAREILLY
2021_MES_429622_1
C/8907
Open Tender
Miscellaneous Works
Item Rate
180 days
HEMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹20,000
Yes
31 Mar 2021
10 Mar 2021
31 Mar 2021
10 Mar 2021
29 Mar 2021
17 Mar 2021
10 Mar 2021 - 15 Mar 2021
60 days
Amount
Taking down ceiling fans of any sweep from ceilings/ wall and refixing the same after repairs/ painting in original position including fixing of nut, bolt & split pin and provision of new twin core twisted PVC insulated multi-stranded flexible copper conductor cable of size 23/0.0076 from ceiling rose to fan complete all as specified and directed. [Note: Repair work/ painting as required shall be measured and paid separately].
All as per item No.1 here in before, but exhaust fans of any sweep
M&L for , cleaning the surfaces of ceiling fans of any sweep thoroughly and applying a spray coat of synthetic enamel paint including writing MES No. on fan complete all as specified and directed. by Engr-in-Charge.
All as per item No.03 here in before, but Exhaust Fans of any sweep
M&L for dismantling the stator & rotor of ceiling fan of any sweep, taking out the burnt copper wire, cleaning the stator & rotor with CTC and rewinding the fan with existing gauge and same no of turn with super enameled copper including varnishing, baking, replacement of sleeves etc. and reassembling the fan and testing, complete all as specified and directed.
All as per item No.5 here in before, but exhaust fans of any sweep
Dismantling the ceiling fan of any sweep, examine complete parts thoroughly, oiling, greasing all parts and complete overhauling of fan including replacement of spares such as bearings, bushes, split pin, nuts, bolt, hooks, screws and re-assembling complete fan and making fully functional complete all as specified and directed. by Engr-in-Charge. [Note: Spares like bearings, bushes, capacitor shall be measured and paid as 'Supply only; and the cost of remaining minor spares shall be deemed to be included in the quoted rate]
All as per item No.7 here in before, but exhaust fans of any sweep complete all as specified and directed.
Supply only metal bush made out of Gun metal/ Brass suitable for ceiling fans/ exhaust fans of any sweep.complete all as specified and directed.
Supply only ball bearings suitable for ceiling fan of any sweepcomplete all as specified and directed.
Supply only ball bearings suitable for exhaust fan of any sweep.complete all as specified and directed.
Supply only capacitor 3.15/2.5 Mfd , 230 Volts, 50Hz. Etc Ucomplete all as specified and directed.
Supply only louver shutter suitable for exhaust fan capacity upto 380 mm sweep etc complete all as specified and directed.
Taking down storage type water heater (geyser) of any type /make up to 50 Ltr capacity after disconnecting electric / water connections and servicing/ replacing worn-out spares including rectification of leakage etc.and necessary T&P and consumables required for welding/ brazing works etc, fixing in original position and reconnecting the electric / water connections and testing complete all as specified and directed. by Engr-in-Charge. Note: Spares will be measured and paid seperately.
Supply only heating element 2000 watts capacity trangle type suitable for 25/35/50 Ltrs. Capacity Geyser all as per exisiting make and specification.
Supply only heating element 2000 watts capacity round type suitable for 25/35/50 Ltrs. Capacity Geyser all as per exisiting make and specification..
Supply only thermostat suitable for 25/50 Ltrs. Capacity Geysers all as per exisiting make and specification.
Supply only Geysers assemely suitable for 25/50 Ltrs. Capacity all as per exisiting make and specification.
Supply and Fix in replacement of flexible "Hot and Cold" connecting pipe 18" long with base adopter for cold water / hot water and connecting up complete for 25/50 Ltrs capacity Geyers, complete all as specified and directed.
Supply and Fix in repairs indication lamp for 25/50 Ltrs capacity Geysers complete all as specified and as directed.
Supply only pressure release valve chromium plated brass suitable for geyser up to 50 Ltr capacity.complete all as specified and directed.
Supply only apparatus plate for 25 Ltrs capacity geyser all as per exisiting make and specification.
Supply only apparatus plate for 35/50 Ltrs capacity geyser all as per exisiting make and specification.
S&F copper flexible wire of 2 x 4 sqmm +1 x 2.5 sqmm multistranded FR PVC insulated for geyser connection complete all as specified and as directed.
Supply only plug top 3 pin 15 amps 230 Volts complete all as specified and directed.
M&L for preparation of old painted surfaces and applying two coats of synthetic enamel paint by using spray gun for electric Geyser of 25/35/50 ltrs capacity complete all as specified and directed.
M&L of services for general maintenance of window/ split type ACs installed in various buildings of RTS & Depot including leak testing etc. by replacing worn-out spares, charging of refrigerant gas etc. including necessary T&P and consumables required for welding/ brazing works etc. complete all as specified and directed. by Engr-in-Charge. [Notes: Spares require replacement, refrigerant gas shall be measured and paid separately as 'Supply only' and the fixing/ charging element is included in the quoted rate]
sealed compressor unit working on 230 Volts AC supply suitable for 1.5 TR split type AC of any make/ model etc complete all as specified and directed..
Supply only sealed compressor unit working on 230 Volts AC supply suitable for 2 TR windowt type AC of any make/ model etc complete all as specified and directed..
Supply only fan motor out door type suitable for 1.5 TR split type AC of any make/ model etc complete all as specified and directed.
Supply only fan motor indoor type suitable for 1.5 TR split type AC of any make/ model etc complete all as specified and directed.
Supply only condenser unit suitable for 1.5 TR split type AC of any make/ model etc complete all as specified and directed..
Supply only Thermostat with knob suitable for 1.5 TR Split/ window type AC.etc complete all as specified and directed.
Supply only starting capacitor of 45/50 mfd capacity for 1.5 TR capacity window/ split type AC. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only front grill assembly suitable for existing model of window AC of any capacity.etc complete all as specified and directed.
M&L of services for general maintenance of refrigerator of capacity upto 310 Ltrs installed in various buildings of RTS & Depot including rectification of leak testing etc. by replacing worn-out spares, charging of refrigerant gas etc. including necessary T&P and consumables required for welding/ brazing works etc. complete all as specified and as directed. [Notes: Spares require replacement, refrigerant gas & Nitrogen gas required for leak testing shall be measured and paid separately as 'Supply only' and the fixing/ charging element is included in the quoted rate]
Supply only compressor suitable for refrigerator of capacity upto 310 ltrs.etc complete all as specified and directed.
Supply only out door type net suitable for existing model of refrigerator of capacity upto 310 Litres etc complete all as specified and directed..
Supply only thermostat suitable for refrigerator of any capacity and makes complete all as specified.
Supply only relay box type suitable for refrigerator of any size and make capacity upto 310 Lts all as specified
Supply only overload protector for any make of refrigerator of capacity upto 310 ltrs of make Sriram/Kirloskar etc complete all as specified and directed.
M&L for servicing to water cooler of any capacity after disconnecting ther water cooler from electric and water supply, clearning the condenser unit with liquid solution, clearning the condenser coil, greasing the fan motor checking /repairing the electric wiring thoroughly, cleaning of water storage tank, replacement of push cook washer, apply one coat of synthetic enameled paint in base ment area housing compressor and condenser and fan motor all as directed by Engr-in-Charge including writing sm no dated of servicing and CA no in 30mm size letters with black paint complete all as directed
Supply only compressor suitable for water cooler of capacity upto 60/120 Litres complete all as specified and directed.
Supply only 15mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball. (Minimum weight 142gms) etccomplete all as specified and directed.
Supply only 15mm dia PVC flexible pipe 600mm long complete for water cooler of any capacity. [Make: Prayag/ Water Tec]
Supply only condenssor suitable for water cooler of any capacity/ make.
M&L of services for general maintenance of deep freezer of capacity 300 Ltrs installed in various buildings of RTS & Depot including rectification of leak testing etc. by replacing worn-out spares including rewinding of any parts, charging of refrigerant gas etc. including necessary T&P and consumables required for welding/ brazing works etc. complete all as specified and as directed. [Notes: Spares require replacement, refrigerant gas & Nitrogen gas required for leak testing shall be measured and paid separately as 'Supply only' and the fixing/ charging element is included in the quoted rate]
Supply only fan motor for deep freezer unit of any capacity.complete all as specified and directed.
Supply only compressor unit of deep freezer of capacity 300 Ltrs including charging of gas.complete all as specified and directed.
M&L of services for general maintenance of desert cooler of any size, installed in various buildings of RTS & Depot including rectification of leak testing etc. by replacing worn-out spares including rewinding of any parts, etc. including necessary T&P and consumables required for welding/ brazing works etc. complete all as specified and as directed.
Supply only fan motor 230 volts 50 Hz, three speed including fan blade suitable for desert cooler of any size
Supply only wood, wood pads suitable for existing size complete all as specified
Supply only water lifting pump with motor 230 volts, 50 Hz suitable for desert cooler of any size.complete all as specified and directed. .
Supply & charging of refrigerant gas R-134 for refrigerator/ water cooler of any capacity complete all as directed
S&F MCB DB SPN 4 way 240V with 200 amps rated bus bar double door all as specified and directed
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 20 to 40 Amps , 240 volts in proper position all as specified and as directed .
Supply & fixing MCB Single Pole (SP) of capacity 6 to 32 amps , 240 volts in proper position all as specified and as directed by the Engineer-in-Charge.
Supply only sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts all as specified. [Make:
Supply only ceiling fan Down Rods of the existing dia/ size of 0.5 mtr length of GI pipe medium grade 15 mm along with new fixing clamps powder coated semi threaded Bolts and nuts with washers and safety pins, vibration damper bush complete all as speciifed and directed,
S & F Sub main wiring with PVC insulated cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor ( for ups )on and incl rigid PVC conduit concealed in wall / roof/ceiling (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 6.0 sq mm for earth continuity all as directed.
S & F Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor on ( for ac and water coolers) and incl rigid PVC conduit concealed in wall / roof/ceiling (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuity all as directed. Note : 2 length single core PVC insulated multistraded copper conductor (FRLS) cable conduit and one length of earth cable shall be measured and paid for one length
Material and labour for earthing complete with copper earth plate electrode 60 x 60 cm and 3.15 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below ground level connected to copper earth strip 20 x 3 mm size by means of nuts, bolts, check nuts and washers of copper/brass all as shown in electrical plate No 5 connected to earthing test point all as specified and directed and 20 mm GI pipe medium grade with funnel for watering and 40 mm GI medium grade pipe 7.5 mtr for copper strip protection from earth pit to test point & PCC for pit with white wash including CI pit cover 30 x 30 cm by taking down old unserviceable earthing. Note Rate quoted includes the cost of Excavation and earth work along with PCC pit, CI cover, copper plate, GI protection pipe, Funnel, Main earth lead/strip upto 7.5 mtr
M&L for earth continuity of copper earth strip of size 20x3mm laid in trenches/ fixed to walls with saddles and fixing screws etc. from earth pit to test point all as specified and directed .
M&L for ,Earthing complete with galvanised steel earth plate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point, 20 mm bore medium grade GI watering pipe, 15mm bore light grade GI protection pipe, earth work, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test on completion all as specified and as directed. Note :- (a) Earth strip / Earth lead beyond 7.5m shall be measured and paid separately. (b) Cost of 15mm and 20mm bore GI pipe is deemed to be included in quoted rates. GENERAL NOTE :- Tenderer may note that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract
M/s Naresh Kalia
raman enterprises
M/S BHATT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .