Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance | L1 | Accepted-Finance Eligible | |
| 2 | L2₹2.8 L+₹44,200 (18.6%)Rejected-Finance R O RAMSHILLA P O AKHARA BAZAR DISTT KULLU | SHIMLA | HIMACHAL PRADESH | 172001 | L2 | Rejected-Finance In Eligible | |
| 3 | L3₹2.9 L+₹51,000 (21.4%)Rejected-Finance | L3 | Rejected-Finance In Eligible |
| Sl No | Description | Qty | Unit | DINA NATH L1 | Amit sood contractor L3 | RITESH KAISTHA L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantaling of existing MSERW pipe of following diameter confirming to ISO: 3183:2007 of following steel grade L-290 and stacking properally at site of work comlete all in respect and to the entire satisfaction of Engineer in charge with in all leads and lifts. 200 mm dia steel pipe ISO 3183:2007 L-290 6.40 mm thick. completewithin all leads and lifts and entire satisfaction of Engineer in charge. | 340 | Rmt | 200 ₹68,000 Lowest | 250 ₹85,000 | 240 ₹81,600 |
| 2.00 | Relaying, jointing (by way of circumferntial butt welding joints by electric arc welding ) and testing of Mild Steel Electric Resistance Weld tubes ( MSERW) of following diameter confirming to ISO:3183 ( latest with up to date ammendments) having minimum wall thickness as per IS code with bevelled/ plain ends in a random lengtth of 4 to 7 meters , including manufacturing reducers/ tapers, all short pices bends etc and class of pipes specified below, provided and jointe as per site requirement made from parent tubes. including lowering and laying in excavated trenches to ensure required level including flushing , cleaning and hydraulic testing complete in all respect to the satisfaction of engineer in charge . the fabricated bends shall have three or four cuts having its radius not less then five times the dia of pipe . the damaged portion of the pipes and specials made from the parant tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bitumenous paint over a primming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
MSERW 200 mm dia X-70 wall thickness 7.00 mm | 340 | Rmt | 500 ₹1,70,000 Lowest | 600 ₹2,04,000 | 590 ₹2,00,600 |
Tender Value
₹1.8 L
EMD Value
₹3,600
Closing Date
2 Oct 2025, 5:30 pmClosed
Executive Engineer
jal shakti division kullu
SH Dismantling and relaying of rising main MSERW pipe 200 mm dia X.70 wall thickness 7.00 mm at various RDs SDF.2025.380
2025_HPIPH_116115_1
5936-86 SDF.2025.380
Open Tender
Civil Works
Item Rate
14 days
Phatti Peej
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer
₹3,600
9 Dec 2025
27 Sept 2025
3 Oct 2025
27 Sept 2025
2 Oct 2025
27 Sept 2025
Amount
Dismantaling of existing MSERW pipe of following diameter confirming to ISO: 3183:2007 of following steel grade L-290 and stacking properally at site of work comlete all in respect and to the entire satisfaction of Engineer in charge with in all leads and lifts. 200 mm dia steel pipe ISO 3183:2007 L-290 6.40 mm thick. completewithin all leads and lifts and entire satisfaction of Engineer in charge.
Relaying, jointing (by way of circumferntial butt welding joints by electric arc welding ) and testing of Mild Steel Electric Resistance Weld tubes ( MSERW) of following diameter confirming to ISO:3183 ( latest with up to date ammendments) having minimum wall thickness as per IS code with bevelled/ plain ends in a random lengtth of 4 to 7 meters , including manufacturing reducers/ tapers, all short pices bends etc and class of pipes specified below, provided and jointe as per site requirement made from parent tubes. including lowering and laying in excavated trenches to ensure required level including flushing , cleaning and hydraulic testing complete in all respect to the satisfaction of engineer in charge . the fabricated bends shall have three or four cuts having its radius not less then five times the dia of pipe . the damaged portion of the pipes and specials made from the parant tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bitumenous paint over a primming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). MSERW 200 mm dia X-70 wall thickness 7.00 mm
RITESH KAISTHA (BID ID -564779)
Amit sood contractor (BID ID -564760)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .