Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.8 LAccepted-AOC | ₹10.8 L | 1 | Accepted-AOC lowest bidder |
| 2 | 2₹11.0 L+₹16,058 (1.49%)Rejected-Finance | ₹11.0 L+₹16,058 (1.49%) | 2 | Rejected-Finance rates on higher side |
| 3 | 3₹11.5 L+₹66,633 (6.17%)Rejected-Finance | ₹11.5 L+₹66,633 (6.17%) | 3 | Rejected-Finance rates on higher side |
| 4 | 4₹11.5 L+₹70,385 (6.52%)Rejected-Finance | ₹11.5 L+₹70,385 (6.52%) | 4 | Rejected-Finance rates on higher side |
| 5 | 5₹11.9 L+₹1.1 L (10.2%)Rejected-Finance | ₹11.9 L+₹1.1 L (10.2%) | 5 | Rejected-Finance rates on higher side |
Tender Value
₹12.9 L
EMD Value
₹25,701
Closing Date
14 Feb 2023, 10:20 amClosed
DFO Nachan
DFO Nachan at Gohar Tehsil Chachiot District Mandi HP
Fgd Hut at Kelodhar
2023_FD_67648_1
8119A
Open Tender
Civil Works - Buildings
Item Wise
150 days
Kelodhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Payable To DFO Nachan
₹25,701
Yes
27 Feb 2023
28 Jan 2023
14 Feb 2023
28 Jan 2023
14 Feb 2023
28 Jan 2023
28 Jan 2023 - 28 Jan 2023
Amount
Site Development-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kind of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level.1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggrigate 25 mm nominal size) up to plinth level with:-Cement mortar 1:6 (1 cement : 6 coarse sand).
Dry stone masonry (uncoursed/brought to course) with hard stone of approved quality in foundation and plinth, breast walls, retaining walls, parapet walls and abutment of culverts etc. i/c dressing of stones.
Main Building Portion-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level.1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggrigate 25 mm nominal size) up to plinth level with:-Cement mortar 1:6 (1 cement : 6 coarse sand).
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and superstructure.Mild steel and medium tensile steel bars.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level. 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):-With modular bricks.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener be paid for seperately).Sall wood.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets. Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets TCT Sheet complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheets. Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. Ridge plain (500-600mm)
Providing and fixing M.S. BP sheet 1.66mm to 2mm thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-Charge (Base members of steel work shall be measured & paid separately)
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperately).6 mm thick cement fiber board as per IS: 14862.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 mtr. And lift upto 1.50 mtr.
Dry stone pitching 15 cm thick including supply of of stones and preparing surface complete.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and acess platform.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and superstructure.Mild steel and medium tensile steel bars.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level.1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying ceramic floor tiles of size in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with300 mm.
Providing and laying 1st quality cramic glazed tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of tiles 500x500 mm.
15 mm cement plaster on the rough side of single or half brick wall of mix :In cement Mortar 1:6.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all comlete.Fixed to openings/ wooden frames with rawal plugs srews etc.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in charge.(Butt hinges and necessary screws shall be paid seperately).Second class teak wood, 35 mm thick shutters.
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary srews. Second class teak wood.
Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia ( heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. 300x16mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour orshade, with necessary srews etc. complete. 200x10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws;-Single rubber stopper.
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:125x63x4 mm. 125x63x4 mm.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :-New work (two or more coats) over and including water thinnable priming coat with cement primer.
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (Hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Septic Tank-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level.-1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):-With modular bricks.
15 mm cement plaster on the rough side of single or half brick wall of mix:-In cement mortar 1:4.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.-40 mm thick with 20 mm nominal size stone agg.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and acess platform.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and superstructure.Mild steel and medium tensile steel bars.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level.-1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
GHAN SHYAM
KASHMIR SINGH RANA
KAUL SINGH
DIMPLE KUMAR
DIWAN SINGH
OMI CHAND
NAGESHWAR SINGH
ROOP LAL
RAJNISH VERMA CONTRACTOR
Harish Kumar
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .